Design of a specialized computer for on-line monitoring of cardiac stroke volume

The design of a specialized analog computer for on-line determination of cardiac stroke volume by means of a modified version of the pressure pulse contour method is presented. The design consists of an analog circuit for computation and a timing circuit for detecting necessary events on the pressure waveform. Readouts of arterial pressures, systolic duration, heart rate, percent change in stroke volume, and percent change in cardiac output are provided for monitoring cardiac patients. Laboratory results showed that computational accuracy was within 3 percent, while animal experiments verified the operational capability of the computer. Patient safety considerations are also discussed.

Webb, J. A., Jr.↗

On-line mass spectrometric monitoring of the polymerization of a phenolic-resin-based material

Polymerization of phenolic-resin-based materials requires elevated temperatures. The low thermal conductivity of these materials has led to the use of dielectric heating techniques in lieu of standard convection oven heating to obtain a satisfactory cure. The curing rate and therefore the quality of the cured material depends on the heating rate and maximum temperature attained, parameters which are extremely difficult to measure in dielectric heating units. The dielectric curing of these materials was monitored by using a mass spectrometer to measure the partial pressure of phenol in the gas evolved during polymerization. The resulting plots of phenol partial pressure as a function of time have a characteristic shape, and these may be used to indicate the attainment of complete curing. The validity of the mass spectrometric technique was confirmed by chemical analysis of the polymerized samples.

Aikens, D. A.↗

Design and fabrication of prototype system for early warning of impending bearing failure

A test program was conducted with the objective of developing a method and equipment for on-line monitoring of installed ball bearings to detect deterioration or impending failure of the bearings. The program was directed at the spin-axis bearings of a control moment gyro. The bearings were tested at speeds of 6000 and 8000 rpm, thrust loads from 50 to 1000 pounds, with a wide range of lubrication conditions, with and without a simulated fatigue spall implanted in the inner race ball track. It was concluded that a bearing monitor system based on detection and analysis of modulations of a fault indicating bearing resonance frequency can provide a low threshold of sensitivity.

Meacher, J.↗

Additional studies for the spectrophotometric measurement of iodine in water

Previous work in iodine spectroscopy is briefly reviewed. Continued studies of the direct spectrophotometric determination of aqueous iodine complexed with potassium iodide show that free iodine is optimally determined at the isosbestic point for these solutions. The effects on iodine determinations of turbidity and chemical substances (in trace amounts) is discussed and illustrated. At the levels tested, iodine measurements are not significantly altered by such substances. A preliminary design for an on-line, automated iodine monitor with eventual capability of operating also as a controller was analyzed and developed in detail with respect single beam colorimeter operating at two wavelengths (using a rotating filter wheel). A flow-through sample cell allows the instrument to operate continuously, except for momentary stop flow when measurements are made. The timed automatic cycling of the system may be interrupted whenever desired, for manual operation. An analog output signal permits controlling an iodine generator.

Source record↗

Study to design and develop remote manipulator system

Modeling of human performance in remote manipulation tasks is reported by automated procedures using computers to analyze and count motions during a manipulation task. Performance is monitored by an on-line computer capable of measuring the joint angles of both master and slave and in some cases the trajectory and velocity of the hand itself. In this way the operator's strategies with different transmission delays, displays, tasks, and manipulators can be analyzed in detail for comparison. Some progress is described in obtaining a set of standard tasks and difficulty measures for evaluating manipulator performance.

Hill, J. W.↗

A computer-controlled scintiscanning system and associated computer graphic techniques for study of regional distribution of blood flow.

Two methods whereby a digital computer may be used to regulate a scintiscanning process are discussed from the viewpoint of computer input-output software. The computer's function, in this case, is to govern the data acquisition and storage, and to display the results to the investigator in a meaningful manner, both during and subsequent to the scanning process. Several methods (such as three-dimensional maps, contour plots, and wall-reflection maps) have been developed by means of which the computer can graphically display the data on-line, for real-time monitoring purposes, during the scanning procedure and subsequently for detailed analysis of the data obtained. A computer-governed method for converting scintiscan data recorded over the dorsal or ventral surfaces of the thorax into fractions of pulmonary blood flow traversing the right and left lungs is presented.

Coulam, C. M.↗

Study to design and develop remote manipulator system

Human performance measurement techniques for remote manipulation tasks and remote sensing techniques for manipulators are described for common manipulation tasks, performance is monitored by means of an on-line computer capable of measuring the joint angles of both master and slave arms as a function of time. The computer programs allow measurements of the operator's strategy and physical quantities such as task time and power consumed. The results are printed out after a test run to compare different experimental conditions. For tracking tasks, we describe a method of displaying errors in three dimensions and measuring the end-effector position in three dimensions.

Hill, J. W.↗

Development of a digital control system for a spacecraft propulsion test facility

A digital computer control and abort system which is used at NASA-Lewis research center is described. The system was designed to control test operations such as rocket engine testing, structure testing, and wind tunnel tests. Because of the nature of spacecraft system testing, particularly rocket engine testing, the unique features of the system are, control function updating at a 20 millisecond rate, continuous abort monitoring and a software system designed for short duration tests rather than continuous on-line control. To accomplish these system requirements, special hardware was designed. The presentation includes a description of the computer system and special interface hardware as well as a general description of the software used.

Smalley, R. R.↗

Development of a digital control system for a spacecraft propulsion test facility.

A digital computer control and abort system which is used at NASA-Lewis Research Center's Plum Brook Test Facilities is described. The system was designed by NASA personnel to control test operations such as rocket engine testing, structure testing, and wind tunnel tests. Because of the nature of spacecraft system testing, particularly rocket engine testing, the unique features of the system are, control function updating at a 20 millisecond rate, continuous abort monitoring and a software system designed for short duration tests rather than continuous on-line control. To accomplish these system requirements, special hardware was designed. The presentation will include a description of the computer system including special interface hardware as well as a general description of the software used.

Smalley, R. R.↗

Development of a digital control system for a spacecraft propulsion test facility.

Description of a digital computer control and abort system designed by NASA personnel to control test operations such as rocket engine testing, structure testing, and wind tunnel tests. Because of the nature of spacecraft system testing, particularly rocket engine testing, the unique features of the system are, control function updating at a 20 millisecond rate, continuous abort monitoring, and a software system designed for short duration tests rather than continuous on-line control. The presentation includes a description of the computer system and special interface hardware as well as a general description of the software used.

Smalley, R. R.↗

Research program for experiment M133

The development of the automatic data-acquisition and sleep-analysis system is reported. The purpose was consultation and evaluation in the transition of the Skylab M133 Sleep-Monitoring Experiment equipment from prototype of flight status; review of problems associated with acquisition and on-line display of data in near-real time via spacecraft telemetry; and development of laboratory facilities and design of equipment to assure reliable playback and analysis of analog data. The existing prototype system modified, and the changes improve the performance of the analysis circuitry and increase its reliability. These modifications are useful for pre- and postflight analysis, but are not now proposed for the inflight system. There were improvements in the EEG recording cap, some of which will be incorporated into the flight hardware.

Frost, J. D., Jr.↗

Feasibility of an on-line fission-gas-leak detection system

Calculations were made to determine if a cladding failure could be detected in a 100-kW zirconium hydride reactor primary system by monitoring the highly radioactive NaK coolant for the presence of I-131. The system is to be completely sealed. A leak of 0.01 percent from a single fuel pin was postulated. The 0.364-MeV gamma of I-131 could be monitored on an almost continuous basis, while its presence could be varified by using a longer counting time for the 0.638-MeV gamma. A lithium-drifted germanium detector would eliminate radioactive corrosion product interference that could occur with a sodium iodide scintillation detector.

Lustig, P. H.↗

Stellar refraction - A tool to monitor the height of the tropopause from space

Calculations of stellar refraction for a setting or rising star as viewed from a spacecraft show that the tropopause is a discernible feature in a plot of refraction vs time. The height of the tropopause is easily obtained from such a plot. Since the refraction suffered by the starlight appears to be measurable with some precision from orbital altitudes, this technique is suggested as a method for remotely monitoring the height of the tropopause. Although limited to nighttime measurements, the method is independent of supporting data or model fitting and easily lends itself to on-line data reduction.

Schuerman, D. W.↗

In flight ground control of high drag satellites utilizing on-board accelerometer data and rapid orbit prediction techniques

High drag satellites frequently require precise verification of orbital maneuvers and the accurate prediction of perigee height. An in-flight ground support system designed to monitor and compute orbital state and maneuvers is described. The use of on-board three-axis accelerometer data in a flight support software system to perform on-line maneuver analysis and atmospheric model updating is discussed. In addition, automated analytic techniques to rapidly and accurately predict perigee height following a maneuver are described, as well as semianalytic averaging techniques designed to predict a decaying orbital state for mission control.

Fuchs, A. J.↗

Automated iodine monitor system

The feasibility of a direct spectrophotometric measurement of iodine in water was established. An iodine colorimeter, was built to demonstrate the practicality of this technique. The specificity of this method was verified when applied to an on-line system where a reference solution cannot be used, and a preliminary design is presented for an automated iodine measuring and controlling system meeting the desired specifications. An Automated iodine monitor/controller system based on this preliminary design was built, tested, and delivered to the Johnson Space Center.

Source record↗