Technology of forced flow and once-through boiling: A survey

Representative boiling heat transfer and pressure drop information obtained primarily from past NASA and AEC programs is presented which is applicable to forced flow and once-through boiler systems. The forced convection boiler has a number of advantages: little possibility of flow mal-distribution; heat transfer characteristics are usually consistent; and conductances are predictable, so that higher heat fluxes may be employed with safety (which leads to more compact, lighter weight equipment). It was found that in gas-fired systems particularly, the controlling heat transfer resistance may be on the hot side, so that increased fluxes would require extended surfaces. If in a power generation system the working fluid is very expensive, a forced flow boiler can be designed especially for small holdup volume. If the fluid is temperature sensitive, the boiling side wall temperatures can be tailored to maintain maximum heat transfer rates without overheating the fluid. The forced flow and once-through configurations may be the only type which can satisfy a specific need (such as the automotive Rankine cycle power plant design having a very short time-response boiler).

Poppendieck, H. F.↗

Heat and momentum transfer model studies applicable to once-through, forced convection potassium boiling

A number of heat transfer and fluid flow mechanisms that control once-through, forced convection potassium boiling are studied analytically. The topics discussed are: (1) flow through tubes containing helical wire inserts, (2) motion of droplets entrained in vapor flow, (3) liquid phase distribution in boilers, (4) temperature distributions in boiler tube walls, (5) mechanisms of heat transfer regime change, and (6) heat transfer in boiler tubes. Whenever possible, comparisons of predicted and actual performances are made. The model work presented aids in the prediction of operating characteristics of actual boilers.

Sabin, C. M.↗

Forced-flow once-through boilers

A compilation and review of NASA-sponsored research on boilers for use in spacecraft electrical power generation systems is presented. Emphasis is on the heat-transfer and fluid-flow problems. In addition to space applications, much of the boiler technology is applicable to terrestrial and marine uses such as vehicular power, electrical power generation, vapor generation, and heating and cooling. Related research areas are discussed such as condensation, cavitation, line and boiler dynamics, the SNAP-8 project (Mercury-Rankine cycle), and conventional terrestrial boilers (either supercritical or gravity-assisted liquid-vapor separation types). The research effort was directed at developing the technology for once-through compact boilers with high heat fluxes to generate dry vapor stably, without utilizing gravity for phase separations. A background section that discusses, tutorially, the complex aspects of the boiling process is presented. Discussions of tests on alkali metals are interspersed with those on water and other fluids on a phenomenological basis.

Stone, J. R.↗

Oil-air mist lubrication as an emergency system and as a primary lubrication system

The feasibility of an emergency aspirator once-through lubrication system was demonstrated as a viable survivability concept for Army helicopter mainshaft engine bearings for periods as long as 30 minutes. It was also shown in an experimental study using a 46-mm bore bearing test machine that an oil-air mist once-through system with auxiliary air cooling is an effective primary lubrication system at speeds up to 2,500,000 DN for extended operating periods of at least 50 hours.

Loomis, W. R.↗

Types of thermal plumes in coastal waters

A large number of thermal images of the surface temperatures of the thermal plumes associated with the once-through cooling of electric power plants show that four kinds of plume occur sufficiently often to be classified as distinct plume types. Each type has implications for both numerical models and measurement strategies.

Green, T.↗

Thermal discharges and their role in pending power plant regulatory decisions

Federal and state laws require the imminent retrofit of offstream condenser cooling to the newer steam electric stations. Waiver can be granted based on sound experimental data, demonstrating that existing once-through cooling will not adversely affect aquatic ecosystems. Conventional methods for monitoring thermal plumes, and some remote sensing alternatives, are reviewed, using on going work at one Maryland power plant for illustration.

Miller, M. H.↗

Oil-air mist lubrication for helicopter gearing

The applicability of a once-through oil mist system to the lubrication of helicopter spur gears was investigated and compared to conventional jet spray lubrication. In the mist lubrication mode, cooling air was supplied at 366K (200 F) to the out of mesh location of the gear sets. The mist air was also supplied at 366K (200 F) to the radial position mist nozzle at a constant rate of 0.0632 mol/s (3 SCFM) per nozzle. The lubricant contained in the mist air varied between 32 - 44 cc/hour. In the recirculating jet spray mode, the flow rate was varied between 1893 - 2650 cc/hour. Visual inspection revealed the jet spray mode produced a superior surface finish on the gear teeth but a thermal energy survey showed a 15 - 20% increase in heat generated. The gear tooth condition in the mist lubrication mode system could be improved if the cooling air and lubricant/air flow ratio were increased. The test gearbox and the procedure used are described.

Mcgrogan, F.↗

Emergency and microfog lubrication and cooling of bearings for Army helicopters

An analysis and system study was performed to provide design information regarding lubricant and coolant flow rates and flow paths for effective utilization of the lubricant and coolant in a once-through oil-mist (microfog) and coolant air system. A system was designed, manufactured, coupled with an existing rig and evaluation tests were performed using 46 mm bore split-inner angular-contact ball bearings under 1779N (400 lb.) thrust load. An emergency lubrication aspirator system was also manufactured and tested under lost lubricant conditions. The testing demonstrated the feasibility of using a mist oil and cooling air system to lubricate and cool a high speed helicopter engine mainshaft bearing. The testing also demonstrated the feasibility of using an emergency aspirator lubrication system as a viable survivability concept for helicopter mainshaft engine bearing for periods as long as 30 minutes.

Rosenlieb, J. W.↗

Simultaneous stack gas scrubbing wastewater purification

Variations of a process for removing sulfur dioxide from stack gases and using it to treat municipal waste water are described. The once-through system lowers the pH of the scrubbing water from minor depressions to a pH of about 2.5 under certain conditions. A recycle system uses iron for catalytic oxidation of sulfurous acid to sulfuric acid allowing very large amounts of sulfur dioxide to be absorbed in a small portion of water. The partial recycle system uses municipal wastewater and iron as a scrubbing medium, followed by neutralization of the wastewater with lime to produce an iron hydroxide precipitation which, when removed, produces tertiary quality treated wastewater. The SO2 scrubber is described, test results are analyzed, and a preliminary capital cost estimate for the three processes is included.

Source record↗

The development of an air Brayton and a steam Rankine solar receiver

An air Brayton and a steam Rankine solar receiver now under development are described. These cavity receivers accept concentrated insolation from a single point focus, parabolic concentrator, and use this energy to heat the working fluid. Both receivers were designed for a solar input of 85 kw. The air Brayton receiver heats the air to 816 C. A metallic plate-fin heat transfer surface is used in this unit to effect the energy transfer. The steam Rankine receiver was designed as a once-through boiler with reheat. The receiver heats the water to 704 C to produce steam at 17.22 MPa in the boiler section. The reheat section operates at 1.2 MPA, reheating the steam to 704 C.

Greeven, M. V.↗

The development of an 85-kW (thermal) steam Rankine solar receiver

The receiver is a once-through monotube boiler designed for steam/electric and process steam applications at pressures up to 17.24 MPa (2500 psia) and temperatures up to 704 C (1300 F). The unit is 76.2 cm (30.0 in.) in diameter and 95.8 cm (37.7 in.) in length; it weighs 220 kg (485 lb). Its heat transfer surface, which is 45.7 cm (18 in.) in diameter by 57 cm (22.4 in.) long, is an Inconel 625, cylindrical, tube-coil assembly composed of primary and reheat sections. A test unit was successfully operated at up to 6.9 MPa (1000 psia) and 704 C (1300 F) with solar input from a 11-m-dia parabolic dish concentrator.

Wright, C. C.↗

Organic Rankine cycle receiver development

The selected receiver concept is a direct-heated, once-through, monotube boiler operated at supercritical pressure. The cavity is formed by a cylindrical copper shell and backwall, with stainless steel tubing brazed to the outside surface. This core is surrounded by lightweight refractory insulation, load-bearing struts, and an outer case. The aperture plate is made of copper to provide long life by conduction and reradiation of heat away from the aperture lip. The receiver thermal efficiency is estimated to be 97 percent at rated conditions (energy transferred to toluene divided by energy incident on aperture opening). Development of the core manufacturing and corrosion protection methods is complete.