Search NASA⌕ Search

SEARCH · Search NASA

Results for “open circuit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Open Circuit Potential Method for Thermodynamic Hydricity Measurements of Metal Hydrides

Metal hydrides are prevalent in many catalytic reactions, and thermodynamic hydricity has emerged as a useful parameter for understanding and predicting key hydride transfer steps with these intermediates. An open circuit potentiometry method for determining the hydricity of metal hydrides with a single thermodynamic parameter is reported. The open circuit potential (OCP) of a solution containing a metal hydride and its conjugate hydride acceptor, along with a conjugate acid/base pair, is coupled with known values for the acid pK a and H + /H – reduction potential to determine the hydricity. Here, the reliability of the method was established by using potentiometry to obtain the hydricity of three hydride complexes with varying supporting ligands and transition metal elements in acetonitrile solvent, all within error of previously reported values. Advantages and drawbacks of this method are discussed, and a recommended workflow for practitioners is introduced.

Anions↗

Ion Chromatography and Combustion Ion Chromatography Analysis of Fuel Cell Effluent Water During Open Circuit Voltage

Open circuit voltage tests were conducted on sixteen 3M Ionomer and eight Nafion™ NR211 membranes. Lifetime distributions were determined, and ion chromatography (IC) techniques were used to measure fluoride, sulfate, trifluoro acetate, and oxalate ions. Combustion Ion Chromatography (CIC) was used to determine the total organic fluoride (TOF) associated with water soluble membrane degradation fragments. The ratio of these products relative to the fluoride release rates were used to infer the likely degradation mechanism for each membrane. Peroxide attack at the sulfonic acid side chain was determined to be the least relevant reaction pathway while the long-proposed polymer chain end unzipping appears to be the dominant mechanism. Abstraction of the tertiary fluorine in the NR211 backbone and side chain is evident by organic fluoride release rates higher than can be explained by unzipping alone.

25 ENERGY STORAGE↗

Direct nanoscale mapping of open circuit voltages at local back surface fields for PERC solar cells

The open circuit voltage (V OC) is a critical and common indicator of solar cell performance as well as degradation, for panel down to lab-scale photovoltaics. Detecting V OC at the nanoscale is much more challenging, however, due to experimental limitations on spatial resolution, voltage resolution, and/or measurement times. Accordingly, in this work an approach based on Conductive Atomic Force Microscopy is implemented to directly detect the local V OC , notably for monocrystalline Passivated Emitter Rear Contact (PERC) cells which are the most common industrial-scale solar panel technology in production worldwide. This is demonstrated with cross-sectioned monocrystalline PERC cells around the entire circumference of a poly-Aluminum-Silicide via through the rear emitter. The V OC maps reveal a local Back Surface Field extending ~2 μm into the underlying p-type Si absorber due to Al in-diffusion as designed. Such high spatial resolution methods for photovoltaic performance mapping are especially promising for directly visualizing the effects of processing parameters, as well as identifying signatures of degradation for silicon and other solar cell technologies.

14 SOLAR ENERGY↗

A Numerical Study on the Impact of Cathode Catalyst Layer Loading on the Open Circuit Voltage

The open-circuit voltage (OCV) is the measured potential when no current is drawn from a cell. Additionally, theoretically this potential is given by the equilibrium potential, which is determined from thermodynamics based on the operating conditions. In practice, the actual potential at zero current is measured to be approximately 300 mV lower than the theoretical value.

42 ENGINEERING↗

Measurement of shunt resistance and conduction band offset in Cu(In,Ga)Se 2 solar cells through joint analysis of temperature and intensity dependence of open-circuit voltage and photoluminescence

Joint analysis studies of open-circuit voltage and photoluminescence intensity (PL-I) are reported for CuIn 1-x GaxSe 2 (CIGSe) solar cells. A range of compositions are investigated, including constant x=0.35 and x=0.55 as well as a graded composition profile having a minimum of x=0.25. Both the open circuit voltage and PL-I are measured as functions of temperature and illumination intensity. With these two measurements, a full model-based fitting of the temperature and illumination dependence allows extraction of the effects of window layer band offset and shunt resistance, in addition to bulk and interface recombination parameters. Finally, to quantitatively analyze the two distinct measurements jointly, the absolute PL-I is measured to obtain quasi-Fermi-level splitting.

14 SOLAR ENERGY↗

Near surface defects: Cause of deficit between internal and external open-circuit voltage in solar cells

The presence of interface recombination in a complex multilayered thin-film solar structure causes a disparity between the internal open-circuit voltage (V OC,in ), measured by photoluminescence, and the external open-circuit voltage (V OC,ex ) i.e. an additional V OC deficit. Higher V OC,ex value aim require a comprehensive understanding of connection between V OC deficit and interface recombination. Here, a deep near-surface defect model at the absorber/buffer interface is developed for copper indium di-selenide solar cells grown under Cu excess conditions to explain the disparity between V OC ,in and V OC,ex . The model is based on experimental analysis of admittance spectroscopy and deep-level transient spectroscopy, which show the signature of deep acceptor defect. Further, temperature-dependent current-voltage measurements confirm the presence of near surface defects as the cause of interface recombination. The numerical simulations show strong decrease in the local V OC ,in near the absorber/buffer interface leading to a V OC deficit in the device. This loss mechanism leads to interface recombination without a reduced interface bandgap or Fermi level pinning. Further, these findings demonstrate that the V OC ,in measurements alone can be inconclusive and might conceal the information on interface recombination pathways, establishing the need for complementary techniques like temperature dependent current voltage measurements to identify the cause of interface recombination in the devices.

14 SOLAR ENERGY↗

Novel Electrochemical Technique: Serial Open Circuit Potentiometry to Examine the Separability of Lanthanides in Molten Salts

The accumulation of lanthanide fission products in molten salts reduces the efficiency of pyroprocessing used nuclear fuel. Lanthanide fission products are notoriously difficult to separate due to their similar physical and electrical properties. We developed a novel electrochemical technique called serial open circuit potentiometry (SOCP) which allows us to delineate between metal deposition reactions with similar reduction potentials to great precision. SOCP has several advantages over traditional open circuit potentiometry including its ability to create 3D plots that describe all metal deposition reactions in a system. This information can be used to precisely determine equilibrium potentials of metal deposition reactions and quantify their error, determine nucleation potentials, and determine the nucleation and growth mechanism. In this work, we demonstrated the effectiveness of SOCP by studying molten salt mixtures containing CeCl3, GdCl3, and both CeCl3 and GdCl3 in LiCl-KCl eutectic.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effects of open circuit immersion and vertex potential on potentiodynamic polarization scans of metallic biomaterials

Abstract Electrodes made of commercially pure titanium (CP-Ti) and a CoCrMo alloy are immersed at an open circuit in a phosphate buffer saline electrolyte at room temperature for different durations prior to electrochemical analyses. Open circuit potential measurements, electrochemical impedance spectroscopy measurements, and cyclic potentiodynamic polarization (CPP) scans are used to assess the impact of the immersion time on derived property values. Stable passivation layers formed on both materials during immersion. The corrosion potentials determined from the anodic legs of CPP scans become more cathodic, and the corrosion currents decrease to lower values after longer immersion times. Measured currents indicate the layers formed on CP-Ti stabilize during forward anodic scans and persist to the vertex potential, whereas passivation breakdown occurs during anodic scans with CoCrMo with active corrosion at voltages up to the vertex potential. The characteristics of the return cathodic legs of CPP scans represent the surface conditions at the vertex potential: characteristic corrosion property values derived from the test responses represent passive surfaces on CP-Ti and leached surfaces on CoCrMo rather than intrinsic properties of those materials.

36 MATERIALS SCIENCE↗

Open Circuit Potential of a Au Catalyst during Selective Oxidation of Glycerol

It has been of great interest to understand relationships between the potential of a metal catalyst and its thermochemical catalytic activity, especially in an aqueous phase environment. In the literature, there are correlations of open circuit potential with reaction rates or surface concentrations of reaction intermediates. In this study, we measured the open circuit potential (OCP) of a Au gauze during selective oxidation of glycerol to glyceric acid and hydrogen peroxide in a basic solution, as a function of hydroxide and alcoholate concentrations. It is found that applying a potential to the Au catalyst has no influence on the reaction rate. Although a rough correlation appears to exist between OCP and reaction rate, the data are better fit to an equation which assumes that the potential of the metal (i.e. the OCP) is in equilibrium with the electrochemical potential of the solution, which is defined by the thermodynamic activities of the oxidizing and reducing species. The equation: OCP = constant + Σ ox [(RT/FZ ox )ln[Ox]] - Σ red [(RT/FZ red )ln[Red]] implicitly assumes that the Au metal functions as a probing electrode. It is further found that this equation also applies to the Au-catalyzed H 2 O 2 oxidation/decomposition reaction in a basic medium, and possibly to formic acid dehydrogenation. Here, we postulate that the apparent correlation between OCP and reaction rate is due to the fact that the reaction rate is proportional to the concentrations of the reaction products and/or reactants that define the electrochemical potential of the solution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Precursor Reaction Method With High Ga Cu(In,Ga)(S,Se)$_{2}$ to Achieve Increased Open-Circuit Voltage

The precursor reaction process for the fabrication of Cu(In,Ga)Se 2 solar cells potentially allows for low-cost fabrication and scalable processing for manufacturing. Additionally, this process has yielded record efficiencies in lab-scale experiments. Thus far, research on the precursor reaction method has been restricted to relatively low Ga compositions with Ga/(In+Ga) ≈ 25%. By increasing the ratio of Ga, it is possible to increase the bandgap, and thus, increase the open-circuit voltage. This work develops and characterizes the precursor reaction process for use with Ga/(In+Ga) ≈ 50%, with the goal of improving the open-circuit voltage and efficiency. It is shown that with an increased Ga ratio, increased V ∞ is achieved, but the rate of conversion from the precursor to absorber phases is decreased. Additionally, increased Ga improves the film adhesion at increased selenization temperatures as well as improving the film morphology.

14 SOLAR ENERGY↗

Importance of interface open circuit potential on aqueous hydrogenolytic reduction of benzyl alcohol over Pd/C

Abstract The open circuit potential (OCP) established by the quasi-equilibrated electrode reaction of H 2 and H 3 O + (hydr.) , complicates catalytic reactions significantly. The hydrogenolysis rate of benzylic alcohol on Pd/C increases 2-3 orders of magnitude with the pH decreasing from 7 to 0.6. The reaction follows a pathway of protonated benzyl alcohol dehydration to a benzylic carbenium ion, followed by a hydride addition to form toluene. The dehydration of protonated benzyl alcohol is kinetic relevent, thus, being enhanced at lower pH. The OCP stabilizes all cationic species in the elementary steps. Particularly, the initial state (benzyl alcohol oxonium ion) is less stabilized than the dehydration transition state and the product (benzylic carbenium), thus, lowering the free energy barrier of the rate-determining step. In accordance, the rate increased with increasingly negative OCP. Beside OCP, an external negative electric potential in an electrocatlaytic system was also demonstrated to enhance the rate in the same way.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Arylammonium-Assisted Reduction of the Open-Circuit Voltage Deficit in Wide-Bandgap Perovskite Solar Cells: The Role of Suppressed Ion Migration

Surface treatment using large alkyl/aryl ammonium cations has demonstrated reduced open-circuit voltage (V OC ) deficits in perovskite solar cells (PSCs), but the origin of the improvements has been vaguely attributed to defect passivation. Here, we combine the microscopic probing of the local electrical properties, thermal admittance spectroscopic analysis, and first principles calculations to elucidate the critical role of arylammonium interface layers on suppressing the ion migration in wide-bandgap (WBG) PSCs. Our results reveal that arylammonium surface treatment using phenethylammonium iodide increases the activation energy barrier for ion migration on the surface, which suppresses the accumulation of charge defects at surface and grain boundaries (GBs), leading to reduced dark saturation current density in WBG PSCs. Furthermore, with device optimization, our champion 1.73-eV PSC delivers a power conversion efficiency of 19.07% with a V OC of 1.25 V, achieving a V OC -deficit of 0.48 V.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Cost-Effective Electro-Hydraulic Actuator Solution with Open Circuit Architecture

With the recent electrification trend in the fluid power area, more research has been incentivized to propose cost-effective and energy-efficient solutions for hydraulic systems. Hence, electro-hydraulic actuator (EHA) architectures receive increasing attention. The paper proposes a novel open-circuit EHA architecture, with the goal to obtain a cost-effective solution for mobile applications while maximizing the overall system efficiency. The proposed EHA is capable of meeting or exceeding traditional off-road machine performance, therefore enabling further electrification of off-road machines. Four-quadrant functionality, covering the full speed range, is achieved by a combination of a variable electro-hydraulic drive and valves with different functions. Focusing on the steady-state performance, the functionality is validated by numerical as well as experimental methods. A simulation model based on the Amesim environment and a dedicated test setup was developed to verify the performance. Furthermore, the good match between simulation and experimental results confirms the potential of the formulation approach of the proposed EHA for applications with different duty cycles and power levels.

4-quadrant functionality↗

Formulation, Design and Experimental Verification of an Open Circuit Electro-Hydraulic Actuator

With the recent electrification trend in the fluid power area, more research has been incentivized to the proposal of cost-effective and energy-efficient solutions for hydraulic systems. Hence, electro-hydraulic actuator (EHA) architectures receive increasing attention. The paper proposes a novel open-circuit EHA architecture, with the goal to obtain a cost-effective mobile solution while maximizing the overall system efficiency. The proposed EHA is capable of meeting or exceeding traditional off-road machine performance, therefore enabling further electrification of off-road machines. Four-quadrant functionality, covering the full speed range, is achieved by a combination of a variable electro-hydraulic drive and valves with different functions and is validated by numerical as well as experimental methods. Here, a simulation model based on the Amesim environment and a dedicated test setup was developed to verify the performance. The good match between simulation and experimental results confirms the potential of the formulation approach of the proposed EHA for applications with different duty cycles and power levels.

24 POWER TRANSMISSION AND DISTRIBUTION↗