Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical Interferometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Quantum noise in optical interferometers

We study the photon counting noise in optical interferometers used for gravitational wave detection. In order to reduce quantum noise, a squeezed vacuum is injected into the usually unused input port. It is investigated under which conditions the gravitational wave signal may be amplified without increasing counting noise concurrently. Such a possibility was suggested as a consequence of the entanglement of the two output ports of a beam splitter. We find that amplification without concurrent increase of noise is not possible for reasonable squeezing parameters. Photon distributions for various beam splitter angles and squeezing parameters are calculated.

74 ATOMIC AND MOLECULAR PHYSICS↗

Navy precision optical interferometer measurements of 10 stellar oscillators

Using the Navy Precision Optical Interferometer, we measured the angular diameters of 10 stars that have previously measured solar-like oscillations. Our sample covered a range of evolutionary stages but focused on evolved subgiant and giant stars. We combined our angular diameters with Hipparcos parallaxes to determine the stars' physical radii, and used photometry from the literature to calculate their bolometric fluxes, luminosities, and effective temperatures. We then used our results to test the scaling relations used by asteroseismology groups to calculate radii and found good agreement between the radii measured here and the radii predicted by stellar oscillation studies. The precision of the relations is not as well constrained for giant stars as it is for less evolved stars.

79 ASTRONOMY AND ASTROPHYSICS↗

Binary pseudorandom array test standard optimized for characterization of large field-of-view optical interferometers

Recently, a technique for calibrating the modulation transfer function (MTF) of a broad variety of metrology instrumentation has been demonstrated. This technique is based on test samples structured as one-dimensional binary pseudo-random (BPR) sequences and two-dimensional BPR arrays (BPRAs). The inherent power spectral density of BPR gratings (sequences) and arrays has a deterministic white-noise-like character that allows direct determination of the MTF with uniform sensitivity over the entire spatial frequency range and field-of-view of an instrument. As such, the BPR samples satisfy the characteristics of a test standard: functionality, ease of specification and fabrication, reproducibility, and low sensitivity to manufacturing error. Here we discuss our recent developments directed to the optimization of the sample design, fabrication, application, and data processing procedures, suitable for thorough characterization of large aperture optical interferometers. Compared with the previous coded-aperture based design, the improved, 'highly randomized' BPRA pattern of the new test standard provides better accuracy and reliability of instrument MTF and aberration characterization, and enables operation optimization of large aperture optical interferometers. We describe the pattern generation algorithm and tests to verify the compliance to desired BPRA topography. The data acquisition and analysis procedures for different applications of the technique are also discussed.

Yashchuk, Valeriy V.↗

Characterization and operation optimization of large aperture optical interferometers using binary pseudorandom array test standards

Recently, a technique for calibration of the Modulation Transfer Function (MTF) of a broad variety of metrology instrumentation has been established. The technique is based on test samples structured according to binary pseudorandom (BPR) one-dimensional sequences and two-dimensional arrays. The inherent power spectral density of BPR gratings and arrays, has a deterministic white-noise-like character that allows a direct determination of the MTF with a uniform sensitivity over the entire spatial frequency range and field-of-view of an instrument. As such, the BPR samples satisfy the characteristics of a test standard: Functionality, ease of specification and fabrication, reproducibility, and low sensitivity to manufacturing error. Here we discuss our recent developments working with support of the U.S. Department of Energy on industrialization of the technique. The goal is to develop affordable BPR test samples, application procedures, and data processing software, suitable for thorough characterization of optical interferometers and microscopes, as well as x-ray, electron (scanning and transmission), and atomic force microscopes. We report on the development of BPR array test samples optimized for advanced characterization (including the instrumental MTF and aberrations) and operation optimization of large aperture optical interferometers. We describe the sample fabrication process and tests to verify the compliance to desired surface topography. The data acquisition and analysis procedures for application of the technique for precise focusing of Fizeau interferometer are discussed in detail.

Yashchuk, VV↗

A fiber-optic interferometer with subpicometer resolution for dc and low-frequency displacement measurement

We have developed a fiber-optic interferometer optimized for best performance in the frequency range from dc to 1 kHz, with displacement linearity of 1% over a range of {+-} 25 nm, and noise-limited resolution of 2 pm. The interferometer uses a tunable infrared laser source (nominal 1550 nm wavelength) with high amplitude and wavelength stability, low spontaneous self-emission noise, high sideband suppression, and a coherence control feature that broadens the laser linewidth and dramatically lowers the low-frequency noise in the system. The amplitude stability of the source, combined with the use of specially manufactured ''bend-insensitive'' fiber and all-spliced fiber construction, results in a robust homodyne interferometer system, which achieves resolution of 40 fm Hz{sup -1/2} above 20 Hz and approaches the shot-noise-limit of 20 fm Hz{sup -1/2} at 1 kHz for an optical power of 10 {mu}W, without the need for differential detection. Here we describe the design and construction of the interferometer, as well as modes of operation, and demonstrate its performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CONFIRMING FUNDAMENTAL PROPERTIES OF THE EXOPLANET HOST STAR {epsilon} ERIDANI USING THE NAVY OPTICAL INTERFEROMETER

We measured the angular diameter of the exoplanet host star {epsilon} Eridani using the Navy Optical Interferometer. We determined its physical radius, effective temperature, and mass by combining our measurement with the star's parallax, photometry from the literature, and the Yonsei-Yale isochrones, respectively. We used the resulting stellar mass of 0.82 {+-} 0.05 M{sub Sun} plus the mass function from Benedict et al. to calculate the planet's mass, which is 1.53 {+-} 0.22 M{sub Jupiter}. Using our new effective temperature, we also estimated the extent of the habitable zone for the system.

79 ASTRONOMY AND ASTROPHYSICS↗

Six-channel adaptive fibre-optic interferometer

We have proposed and analysed a scheme for the multiplexing of orthogonal dynamic holograms in photorefractive crystals which ensures almost zero cross talk between the holographic channels upon phase demodulation. A six-channel adaptive fibre-optic interferometer was built, and the detection limit for small phase fluctuations in the channels of the interferometer was determined to be 2.1 Multiplication-Sign 10{sup -8} rad W{sup 1/2} Hz{sup -1/2}. The channel multiplexing capacity of the interferometer was estimated. The formation of 70 channels such that their optical fields completely overlap in the crystal reduces the relative detection limit in the working channel by just 10 %. We found conditions under which the maximum cross talk between the channels was within the intrinsic noise level in the channels (-47 dB).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

NAVY PRECISION OPTICAL INTERFEROMETER OBSERVATIONS OF THE EXOPLANET HOST {kappa} CORONAE BOREALIS AND THEIR IMPLICATIONS FOR THE STAR'S AND PLANET'S MASSES AND AGES

We used the Navy Precision Optical Interferometer to measure the limb-darkened angular diameter of the exoplanet host star {kappa} CrB and obtained a value of 1.543 {+-} 0.009 mas. We calculated its physical radius (5.06 {+-} 0.04 R{sub Sun }) and used photometric measurements from the literature with our diameter to determine {kappa} CrB's effective temperature (4788 {+-} 17 K) and luminosity (12.13 {+-} 0.09 L{sub Sun }). We then placed the star on an Hertzsprung-Russell diagram to ascertain the star's age (3.42{sup +0.32}{sub -0.25} Gyr) and mass (1.47 {+-} 0.04 M{sub Sun }) using a metallicity of [Fe/H] = +0.15. With this mass, we calculated the system's mass function with the orbital elements from a variety of sources, which produced a range of planetary masses: m{sub p}sin i = 1.61-1.88 M{sub Jup}. We also updated the extent of the habitable zone for the system using our new temperature.

79 ASTRONOMY AND ASTROPHYSICS↗

Increasing Baselines and Precision of Optical Interferometers Using Two-Photon Interference

Observations using interferometers provide sensitivity to features of images on angular scales much smaller than any single telescope, on the order of Δθ ~ λ/b where b is the interferometric baseline. Present-day optical interferometers are essentially classical, interfering single photons with themselves. However, there is a new wave of interest in interferometry using multiple photons, whose mechanisms are inherently quantum mechanical, which offer the prospects of increased baselines and finer resolutions among other advantages. We will discuss recent ideas and results for quantum-assisted interferometry using the resource of entangled pairs, and specifically a two-photon amplitude technique aimed at improved precision in astrometry.

47 OTHER INSTRUMENTATION↗

A CATALOG OF CALIBRATOR STARS FOR NEXT-GENERATION OPTICAL INTERFEROMETERS

Benchmark stars with known angular diameters are key to calibrating interferometric observations. With the advent of optical interferometry, there is a need for suitably bright, well-vetted calibrator stars over a large portion of the sky. We present a catalog of uniformly computed angular diameters for 1510 stars in the northern hemisphere, brighter than V = 6 and with declinations -15°<δ<82°. The median angular stellar diameter is 0.529 mas. The list has been carefully cleansed of all known binary and multiple stellar systems. We derive the angular diameters for each of the stars by fitting spectral templates to the observed spectral energy distributions (SEDs) from literature fluxes. We compare these derived angular diameters against those measured by optical interferometry for 75 of the stars, as well as to 176 diameter estimates from previous calibrator catalogs, finding in general excellent agreement. The final catalog includes our goodness-of-fit metrics as well as an online atlas of our SED fits. The catalog presented here permits selection of the best calibrator stars for current and future visible-light interferometric observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Gain balanced nonlinear optical interferometer

A nonlinear fiber interferometer is disclosed suitable for fiber sensor and other applications. A first nonlinear fiber section amplifies probe and conjugate sidebands of a pump through four-wave mixing. A second section introduces a phase shift to be measured, for example from a sensor. A third nonlinear fiber section amplifies with phase-sensitive gain to increase signal-to-noise ratio. Based on phase-sensitive output power of probe and/or conjugate components, the phase shift can be measured. Superior performance can be obtained by balancing gain between the (first and third) nonlinear sections. Non-fiber, for example photonic integrated circuit, embodiments are disclosed. Differential sensing, alternative detection schemes, sensing applications, associated methods, and other variations are disclosed.

42 ENGINEERING↗

Gain balanced nonlinear optical interferometer

A nonlinear fiber interferometer is disclosed suitable for fiber sensor and other applications. A first nonlinear fiber section amplifies probe and conjugate sidebands of a pump through four-wave mixing. A second section introduces a phase shift to be measured, for example from a sensor. A third nonlinear fiber section amplifies with phase-sensitive gain to increase signal-to-noise ratio. Based on phase-sensitive output power of probe and/or conjugate components, the phase shift can be measured. Superior performance can be obtained by balancing gain between the (first and third) nonlinear sections. Non-fiber, for example photonic integrated circuit, embodiments are disclosed. Differential sensing, alternative detection schemes, sensing applications, associated methods, and other variations are disclosed.

Lukens, Joseph M.↗

Gain balanced nonlinear optical interferometer

A nonlinear fiber interferometer is disclosed suitable for fiber sensor and other applications. A first nonlinear fiber section amplifies probe and conjugate sidebands of a pump through four-wave mixing. A second section introduces a phase shift to be measured, for example from a sensor. A third nonlinear fiber section amplifies with phase-sensitive gain to increase signal-to-noise ratio. Based on phase-sensitive output power of probe and/or conjugate components, the phase shift can be measured. Superior performance can be obtained by balancing gain between the (first and third) nonlinear sections. Non-fiber, for example photonic integrated circuit, embodiments are disclosed. Differential sensing, alternative detection schemes, sensing applications, associated methods, and other variations are disclosed.

Lukens, Joseph M.↗

The Interferometer As An Optical Mixer: A Novel Approach To Far Infrared Spectroscopy

In Tokamaks, the Electron Cyclotron Emission (ECE) radiation frequency spans from 80 GHz up to 1 THz for high magnetic field (Bt>5 T) and higher harmonics (n>2). This frequency ranges between Microwaves and Far Infrared (FIR), moulding an intrinsically hybrid nature for ECE diagnostics{sup (1)}. Signal detection is carried out in two surprisingly different ways: electronics and optics. The two detection methods, beyond the chief external differences, are conceptually the same. The dualism often reflects the mindset of the laboratory performing the measurement. In this paper we discuss a different approach to an integrated instrument. A traditional quasi-optical interferometer is the first down-conversion stage with intrinsic broad band capability. Its output signal can then be analysed with a radio-style detection, in the amenable kHz frequency range.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optical zooming interferometer for subnanometer positioning using an optical frequency comb

A high-precision positioning stage based on an optical zooming interferometer is proposed. Two external-cavity diode lasers, stabilized to a femtosecond optical frequency comb, are used as optical sources. The zooming principle is demonstrated, and the positioning resolution of 0.2 nm is achieved. The positioning accuracy was partly evaluated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

WIDE-ANGLE, NARROW-ANGLE, AND IMAGING BASELINES OF OPTICAL LONG-BASELINE INTERFEROMETERS

For optical interferometers, the baseline is typically defined as the vector joining two perfectly identical telescopes. However, when the telescopes are naturally different or when the requirements on the baseline vector challenge the telescope perfection, the baseline definition depends on how the interferometer is used. This is where the notions of wide-angle, narrow-angle, and imaging baselines come into play. This article explores this variety of baselines, with the purpose of presenting a coherent set of definitions, describing how they relate to each other, and suggesting baseline metrology requirements. Ultimately, this work aims at supporting upcoming long-baseline optical interferometers with narrow-angle astrometry and phase-referenced imaging capabilities at the microarcsecond level.

79 ASTRONOMY AND ASTROPHYSICS↗

Single-shot electron bunch length measurements using a spatial electro-optical autocorrelation interferometer

A spatial, electro-optical autocorrelation (EOA) interferometer using the vertically polarized lobes of coherent transition radiation (CTR) has been developed as a single-shot electron bunch length monitor at an optical beam port downstream the 100 MeV preinjector LINAC of the Swiss Light Source. This EOA monitor combines the advantages of step-scan interferometers (high temporal resolution) [D. Mihalcea et al., Phys. Rev. ST Accel. Beams 9, 082801 (2006) and T. Takahashi and K. Takami, Infrared Phys. Technol. 51, 363 (2008)] and terahertz-gating technologies [U. Schmidhammer et al., Appl. Phys. B: Lasers Opt. 94, 95 (2009) and B. Steffen et al., Phys. Rev. ST Accel. Beams 12, 032802 (2009)] (fast response), providing the possibility to tune the accelerator with an online bunch length diagnostics. While a proof of principle of the spatial interferometer was achieved by step-scan measurements with far-infrared detectors, the single-shot capability of the monitor has been demonstrated by electro-optical correlation of the spatial CTR interference pattern with fairly long (500 ps) neodymium-doped yttrium aluminum garnet (Nd:YAG) laser pulses in a ZnTe crystal. In single-shot operation, variations of the bunch length between 1.5 and 4 ps due to different phase settings of the LINAC bunching cavities have been measured with subpicosecond time resolution.

36 MATERIALS SCIENCE↗

Atomic population distribution in the output ports of cold-atom interferometers with optical splitting and recombination

Cold-atom interferometers with optical splitting and recombination use off-resonant laser beams to split a cloud of Bose-Einstein condensate (BEC) into two clouds that travel along different paths and are then recombined again using optical beams. After the recombination, the BEC in general populates both the cloud at rest and the moving clouds. Measuring a relative number of atoms in each of these clouds yields information about the relative phase shift accumulated by the atoms in the two moving clouds during the interferometric cycle. We derive the expression for the probability of finding any given number of atoms in each of the clouds, discuss features of the probability density distribution, analyze its dependence on the relative accumulated phase shift as a function of the strength of the interatomic interactions, and compare our results with experiment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗