Measuring ejecta particle size distributions using dark field imaging versus light field imaging
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The Ocean Color Instrument (OCI), which will be integrated with the Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) satellite, will collect science data that will be used to monitor the health of Earth’s oceans and atmosphere. The Short-Wave Infrared (SWIR) Detection Assembly (SDA), built and characterized by Utah State University Space Dynamics Laboratory (SDL), is a subsystem of OCI consisting of 32 channels covering seven discrete optical bands of interest. A total of 16 SWIR Detection Subassemblies (SDSs) compose the SDA and house the cold optical system. The science data optical input for each SDS is supplied by a 0.22 NA multimode fiber interfacing with a fiber adapter. The diverging light from the fiber is collimated, split by a dichroic beamsplitter to two separate channels, filtered by the science filter, and then reimaged onto the single-element detectors with a final 0.76 NA. Aspheric, diamond-turned powered elements are used throughout the optical design. Fabrication and alignment tolerance analysis/budgets are balanced to ensure the optical system meets throughput requirements. All systems are aligned at ambient temperature using an InSb camera and an in-line illumination microscope system to directly image the active detector area through the science filters. Compensators used during alignment are detector focus and decenter, which are adjusted via photoetched shims in increments of 25 µm. Average focus and centering errors were less than 8 µm among all 32 flight and 10 flight spare detectors. Each SDS spectral response and conversion gain was verified at operational temperature of -65°C in vacuum.
An advanced Microwave Limb Sounder (MLS), now in concept development for a potential future mission, is a space-borne heterodyne instrument to measure pressure, temperature, and atmospheric constituents from thermal emission between 120 and 2400 GHz. Previous MLS instruments used pencil-beam antennas sized to resolve N 1 vertical scale height. Current atmospheric models need better horizontal resolution than orbit spacing provides. To meet these needs, a new antenna concept combines the wide scan range of the parabolic torus with unblocked offset Cassegrain optics. The resulting system is diffraction-limited in the vertical plane but extremely astigmatic, with beamwidths 0.13~2.5. Nadir axis symmetry ensures that this Beam AspectRatio (BAR) is invariant over f33' of azimuth. The antenna can feed either an array of receivers or multiplexed low-noise receivers whose FOVs are swept by a small scanning mirror. We describe 3 stages of antenna design: First, using a paraxial-optics method, we choose conic profiles given vertical resolution orbit geometry, then develop the surfaces by nadir axis rotation, matching axisymmetric feeds to the BAR. A ray-trace program validates the design and generates alignment and deformation tolerances. Finally, a physical optics analysis verifies reflector surface currents and radiation patterns.
This paper describes the optical system used in the Lidar In-Space Technology Experiment (LITE) and presents the results of a study designed to generate a tolerance budget for the LITE, using the combination of manual and Monte Carlo tolerancing techniques utilizing the SYNOPSYS optical analysis program. The tolerance budget derived for LITE, including the contributions of both the fabrication and the alignment of the optical-path elements, are presented. It is shown that the nature of the design allows for typical optical shop tolerances of about 5 mils of despace and decenter, 0.1 deg of tilt, and about 5 fringes of surface figure error.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Carbon Ion Optics are expected to provide much longer thruster life due to their resistance to sputter erosion. There are a number of different forms of carbon that have been used for fabricating ion thruster optics. The mechanical behavior of carbon is much different than that of most metals, and poses unique design challenges. In order to minimize mission risk, the behavior of carbon must be well understood, and components designed within material limitations. Thermal expansion of the thruster structure must be compatible with thermal expansion of the carbon ion optics. Specially designed interfaces may be needed so that grid gap and aperture alignment are not adversely affected by dissimilar material properties within the thruster. The assembled thruster must be robust and tolerant of launch vibration. The following paper lists some of the characteristics of various carbon materials. Several past ion optics designs are discussed, identifying strengths and weaknesses. Electrostatics and material science are not emphasized so much as the mechanical behavior and integration of grid electrodes into an ion thruster.
This study presents the mechanical design and analysis of a quantum electro-optical transducer engineered to operate at millikelvin temperatures within a dilution refrigerator. The transducer enables bidirectional microwave-optical frequency conversion through a hybrid architecture that integrates a superconducting radiofrequency (SRF) cavity with an electro-optic optical cavity. Among several design options investigated, the configuration offering the best thermal and mechanical performance was selected, yielding a robust solution with reduced sensitivity to fabrication tolerances, improved heat dissipation, as well as alignment precision. The design ensures uniform temperature distribution, enabling higher laser pump powers and, thus, increased conversion efficiency, while maintaining mechanical stresses safely below the material yield strength. Electromagnetic simulations further validate the design, demonstrating enhanced coupling between the optical and microwave modes, as well as a broader tuning range achieved with smaller tuner displacements.
The optical hardware design and methods of alignment for the GOES (Geostationary Operational Environmental Satellite) imaging instrument are discussed. The instrument is a multi-channel space-borne meteorological system. Included will be the results of a tolerance and sensitivity analysis for the optics and their adjustment mechanisms. A brief summary of the sequence of system alignment steps taken to achieve the final configuration of the instrument will conclude the discussion.
A grazing incidence x-ray interferometer design capable of micro-arcsecond level resolution is discussed. This practical design employs a Michelson Stellar interferometer approach to create x-ray interference fringes without the use of Wolter style optics or diffraction crystals. Design solutions accommodating alignment, vibration, and thermal constraints are reviewed. We present the development and demonstration of a working experiment along with tolerance studies, data analysis, and results.
The Lidar Atmospheric Sensing Experiment will be performed aboard an ER-2 aircraft; the lidar system used will be mounted on a lightweight, thermally stable graphite/epoxy optical bench whose design is presently subjected to analytical study and experimental validation. Attention is given to analytical methods for the selection of such expected laminate properties as the thermal expansion coefficient, the apparent in-plane moduli, and ultimate strength. For a symmetric laminate in which one of the lamina angles remains variable, an optimal lamina angle is selected to produce a design laminate with a near-zero coefficient of thermal expansion. Finite elements are used to model the structural concept of the design, with a view to the optical bench's thermal structural response as well as the determination of the degree of success in meeting the experiment's alignment tolerances.
This study explores parametrically as a function of wavelength the degrading effects of several common optical aberrations (defocus, astigmatism, wavefront tilts, etc.), using the heterodyne mixing efficiency factor as the merit function. A 60 cm diameter aperture beam expander with an expansion ratio of 15:1 and a primary mirror focal ratio of f/2 was designed for the study. An HDOS copyrighted analysis program determined the value of merit function for various optical misalignments. With sensitivities provided by the analysis, preliminary error budget and tolerance allocations were made for potential optical wavefront errors and boresight errors during laser shot transit time. These were compared with the baseline l.5 m CO2 LAWS and the optical fabrication state of the art (SOA) as characterized by the Hubble Space Telescope. Reducing wavelength and changing optical design resulted in optical quality tolerances within the SOA both at 2 and 1 micrometers. However, advanced sensing and control devices would be necessary to maintain on-orbit alignment. Optical tolerance for maintaining boresight stability would have to be tightened by a factor of 1.8 for a 2 micrometers system and by 3.6 for a 1 micrometers system relative to the baseline CO2 LAWS. Available SOA components could be used for operation at 2 micrometers but operation at 1 micrometers does not appear feasible.
Telescopes require sub-wavelength figure (shape) error in order to achieve acceptable Strehl ratios. Traditional methods of achieving this require rigid and therefore heavy mirrors and reaction structures as well as proportionally heavy and expensive spacecraft busses and launch vehicles. This effectively limits the diameter and therefore resolution and collecting area of space optics. Large diameter telescopes must either be heavy or actively controlled. Space telescopes of the size proposed for missions such as TPF (Terrestrial Planet Finder), TPI (Terrestrial Planet Imager), etc. will likely require large active primaries and structures and corrective optics to implement downstream wavefront control. We propose a novel viable enabling technology. High resolution space imaging requires the production of lightweight large aperture optics subject to design tradespace constraints based on nanometer physical tolerances, low system aerial density, high control authority, suitable thermal and mechanical properties, deployment capability, launch vehicle volume constraints, as well as production cost and schedule risk mitigation. Segmented systems impose additional requirements on segment alignment, wavefront phasing, and telescope mass with increased edge diffraction. Photons weigh nothing. Why must even small space telescopes "weigh" tons? Our team is working to demonstrate that they do not, by leveraging 15 years of effort and a novel advanced concept.The ultimate research goal is to refine technology to produce a mission capable ultra-lightweight membrane optic whose shape can be remotely controlled using a laser beam. Using our novel optically-controlled molecular actuators allows substitution of optically-induced control for rigidity and mirror mass. In analogy with noise-canceling headphones, this technique also potentially provides a way to excite vibratory modes to couple with and damp out normal modes of oscillation induced by slewing, other motion and thermal changes, thus allowing a robust response to repointing of a large aperture.