Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical backscattering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Graphical Optimization of Spectral Shift Reconstructions for Optical Backscatter Reflectometry

Optical backscatter reflectometry (OBR) is an interferometric technique that can be used to measure local changes in temperature and mechanical strain based on spectral analyses of backscattered light from a singlemode optical fiber. The technique uses Fourier analyses to resolve spectra resulting from reflections occurring over a discrete region along the fiber. These spectra are cross-correlated with reference spectra to calculate the relative spectral shifts between measurements. The maximum of the cross-correlated spectra—termed quality—is a metric that quantifies the degree of correlation between the two measurements. Recently, this quality metric was incorporated into an adaptive algorithm to (1) selectively vary the reference measurement until the quality exceeds a predefined threshold and (2) calculate incremental spectral shifts that can be summed to determine the spectral shift relative to the initial reference. Using a graphical (network) framework, this effort demonstrated the optimal reconstruction of distributed OBR measurements for all sensing locations using a maximum spanning tree (MST). By allowing the reference to vary as a function of both time and sensing location, the MST and other adaptive algorithms could resolve spectral shifts at some locations, even if others can no longer be resolved.

47 OTHER INSTRUMENTATION↗

An Adaptive Reference Scheme to Extend the Functional Range of Optical Backscatter Reflectometry in Extreme Environments

Optical frequency domain reflectometry (OFDR) measurements are performed by recording the interference pattern of light backscattered by density fluctuations or Bragg gratings along the length of an optical fiber. Changes in local temperature or strain in the fiber cause shifts in the backscattered light spectrum, which can be calibrated to the applied temperature or strain. Comparing the backscattered optical spectra from each reflection site with a reference (unstrained) spectrum allows for quantification of local spectral shifts. While mature OFDR-based technologies can provide high-precision spatially distributed measurements over kilometer lengths, the post-processing approaches used to recover spectral shifts from raw optical intensity data can limit the use of OFDR in harsh environments. This paper presents a novel approach to post-processing OFDR data which extends the usability of optical fibers exposed to harsh environments. This approach is the first to use the spectral shift quality, calculated for two OFDR measurements, to identify an appropriate reference scan from which the spectral shift can be determined. Here, three experimental data sets are used to test the algorithm: (1) an optical fiber heated to >950°C, (2) an aluminum-embedded optical fiber under strain from differential thermal expansion, and (3) an optical fiber exposed to a total neutron flux of 2×10 13 n/cm 2 /s over 40 hours in a nuclear test reactor. Results show that using a metric of quality to select an appropriate reference measurement extends the functional range of OFDR strain and temperature sensors. Furthermore, this algorithm can be applied to existing OFDR data.

47 OTHER INSTRUMENTATION↗

Active Irradiation Testing of Temperature Sensing Capability of Clad Sapphire Optical Fibers with Type 2 Bragg Gratings using Optical Backscatter Reflectometry

This work investigated the temperature-sensing capabilities of Type II fiber Bragg gratings (FBGs) inscribed in sapphire optical fiber in the Ohio State University Research Reactor (OSURR). A Luna Innovations 4600 optical backscatter reflectometer (OBR) was used to interrogate FBGs in three sapphire optical fibers with an internal cladding that was developed by Ohio State. The sapphire fibers were fusion-spliced to silica lead fibers. In addition to the sapphire fibers, two silica fibers with the same Type II FBGs were included in the experiment as a reference. The fiber-based sensors were irradiated in the Central Irradiation Facility (CIF) of the OSURR for a total of 40 hours over 5 days at a reactor power of 450 kW, resulting in a total neutron fluence of approximately 2.5 × 10 18 n/cm 2 and a gamma dose of approximately 3.48 Grad. Two K-type thermocouples were included within the rig: one at the core centerline and the other 12 inches above the top of the core. The temperature was not actively controlled, but the thermocouples were used to provide a reference to which the fiber-based temperature measurements could be compared.

36 MATERIALS SCIENCE↗

In-field strain and temperature measurements in a (RE)Ba 2 Cu 3 O 7–x coil via Rayleigh-backscattering interrogated optical fibers

(RE)Ba 2 Cu 3 O 7-x (REBCO) conductors have overcome technical challenges related to manufacturing quality, length homogeneity, scale-up of piece-length, and joints. There is one remaining technical challenge, however, which is common to all high temperature superconductors and lies in effective detection of failure to prevent material degradation. An innovative technique based on optical fibers interrogated by Rayleigh backscattering has been shown to have advantages over voltage taps at detecting incipient faults. Prior work has experimentally demonstrated the technique in several implementation scenarios, including direct integration of optical fibers into superconducting conductors and cables to create a class of ‘SMART’ conductors and cables that are able to monitor their own health. In this paper, the magnet monitoring technique based on Rayleigh backscattering interrogated optical fibers has been experimentally studied in a model coil subject to external magnetic field, where different fiber integration methods are used to increase selectivity of the fiber sensor to temperature. Results show that the spectral shift displays different features during strain and thermal transients. The implications of the results in terms of potential and limitations of each sensor as well as strain-temperature decoupling are discussed.

36 MATERIALS SCIENCE↗

Three-Dimensional Imaging Lidar for Characterizing Particle Fields and Organisms in the Mesopelagic Zone

The ocean’s mesopelagic zone is largely uncharacterized despite its vital role in sustaining ocean ecosystems. The composition, cycling, and fate of particle fields in the mesopelagic lacks an integrative multi-scale understanding of organism migration patterns, distribution, and diversity. This problem is addressed by combining complementary technologies with overlapping size spectra, including profiler mounted optical scattering sensors, profiler, and ship mounted acoustic devices, and a custom Unobtrusive Multi-Static Lidar Imager (UMSLI). This unique sensor suite can observe distributions of particles including organisms over a six order of magnitude dynamic size range, from microns to meters. Overlapping size ranges between different methods allows for cross-validation. This work focuses on the lidar imaging measurements and optical backscattering and attenuation, covering a combined particle size range of 0.1 mm to several cm. Particles at the small end of this range are sized using an existing backscattering time series inversion method after Briggs et al. (2013). Larger particles are resolved with UMSLI over an expanding volume using three-dimensional photo-realistic laser serial imaging. UMSLI’s image rectifying ability over time allows for derivation of particle concentration, size, and spatial distribution. Technical details on the development and post-processing methods for the novel UMSLI system are provided. Image resolved particle size distributions (PSDs) revealed a size shift from smaller to larger particles (>0.5 mm) as indicated by flatter slopes from dawn (slope = 2.6) to dusk (slope = 3.0). PSD trends are supported by an optical backscatter and transmissometer time series inversion analysis. Size shifts in the particle field are largely attributed to aggregation effects. Images support evidence of temporal variation between dusk and dawn stations through statistical analysis of particle concentrations for particle sizes 0.50–5.41 mm. Spatial analysis of the particle field revealed a dominantly uniform distributed marine snow background. The importance and potential of integrated approaches to studying particle and organism dynamics in ocean environments are discussed.

54 ENVIRONMENTAL SCIENCES↗

Enhanced backscatter and unsaturated blue wavelength shifts in F-doped fused silica optical fibers exposed to extreme neutron radiation damage

Amorphous fused silica (a-SiO 2 ) optical fibers, with and without inscribed Bragg gratings, were interrogated using infrared (~1550 nm) optical backscatter reflectometry during ~25 days of intense neutron irradiation to a fast (energy > 0.1 MeV) neutron fluence of ~10 21 n/cm 2 , or ~1.5 atomic displacements per atom. The reflected light amplitudes in Ge-doped core telecommunications fiber dropped below detection limits (>15 dB attenuation) within 3 days of irradiation (~10 20 fast n/cm 2 ). Here, amplitudes from a pure silica core, F-doped silica cladding fiber reached equilibrium levels ~1.5–2 dB higher than pre-irradiation values, whereas Bragg gratings inscribed in the same fiber using a femtosecond laser (point-by-point method) suffered > 45 dB attenuation. Blue wavelength shifts were initially consistent with previous radiation-induced compaction models but increased linearly with increasing neutron fluence (no evidence of saturation) beyond 10 20 n/cm 2 and exceeded 0.6%, which corresponds to >1,000 °C drift if used to measure temperature changes.

36 MATERIALS SCIENCE↗

Fiber-optic sensor packaging assessment and benchmarking for embedded sensing applications

Fiber optic-based sensing for non-destructive evaluation (NDE) and structural health monitoring of various infrastructure and energy assets is an increasingly important sensing scheme. Because of their immunity to electromagnetic interferences, versatility in sensing mechanisms and designs as well as capability for distributed sensing, the fiber optic sensing is of great interest for embedding within infrastructures using advanced manufacturing methods. However, the protection of fiber optic sensors during advanced manufacturing-based embedding is an important aspect for infrastructure monitoring in practice. While successful installation of fiber optic sensors has been accomplished through application of epoxy or adhesives on infrastructure surfaces, there has been only limited investigation of fiber protection packaging schemes which are compatible with in-situ repair techniques such as the metallic cold-spray. With increasing interest and importance of cold spray-based repair processes, the integration of fiber optic sensors simultaneously during the repair is equally important. In this work, we focus our efforts on investigating various types of packaging schemes for their compatibility and integrability on the surfaces of metallic structures such as oil and gas pipelines during an in-situ repair coating. First, we consider sandblasting using silica sand particles of various size for optical fibers on the surface of a metallic coupon as a useful proxy test of sensor packaging stability. Structural damage of packaging is characterized by means of optical microscopy and the optical integrity of embedded fiber optic cables is examined using optical backscatter reflectometry (OBR). In addition, initial investigation of metallic cold-spray embedded fiber optic cables under various packaging on metallic substrates is also considered with early conclusions and future directions.

Fiber-optic sensors, Sensors packaging, Metallic C↗

High-Fluence Active Irradiation and Combined Effects Testing of Sapphire Optical Fiber Distributed Temperature Sensors

The goal of this work was to investigate the in-core performance of sapphire optical fiber temperature sensors and to develop clad sapphire optical fibers for in-core instrumentation. We fabricated clad sapphire optical fibers and evaluated the distributed sensing performance of these sensors via optical backscatter reflectometry under high fluence and combined radiation and temperature effects. A series of irradiations was completed to evaluate the effect of irradiation on sapphire optical fiber temperature sensors and to determine the operational limits of these sensors. (1) Objective 1: Fabricate sapphire optical fiber sensors. (2) Objective 2: Evaluate the clad sapphire fiber to verify single-mode behavior and determine and characterize the light modes supported by optical fibers. (3) Objective 3: Characterize the in-core temperature sensing of sapphire optical fiber, as well as the combined temperature and irradiation effects. (4) Objective 4: Evaluate the lifetime and performance of the sensor under irradiation to high neutron fluence. Objectives 1, 2, and 3 were completed during the first 2 years of the project. Due to the Covid pandemic, Objective 4, a high-fluence irradiation performed at the Massachusetts Institute of Technology Research Reactor (MITR), was delayed, as partner facilities were subject to mandatory shutdowns and required a 1 year, no-cost extension. This irradiation was eventually completed on December 12, 2022. This work indicates that sapphire optical fiber sensors may be a solution for ultra-high-temperature applications in which traditional silica optical fibers are prone to fail. Sapphire sensors are potentially suitable for experiments featuring temperatures above 700°C for long periods of time, or for any length of time above 1000°C. Experiments featuring a low total fluence, such as irradiations conducted in the Transient Reactor Test (TREAT) facility, also represent good applications for sapphire optical sensors. Additional work is required to characterize the sapphire fiber cladding performance, which falls outside the scope of this project, as well as the effects of high temperatures on the response of the fiber. A comprehensive material study is recommended as future work to evaluate the attenuation in sapphire under irradiation, and how that attenuation changes with irradiation temperature. The drift and attenuation in the fiber at temperatures of up to 1600°C and a total fluence of up to 2.9 x 10 17 n/cm 2 was minimal, and the fibers returned to baseline after being heated to 1600°C under irradiation. This is promising for the future use of sapphire optical fibers in advanced reactors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Fluence Active Irradiation and Combined Effects Testing of Sapphire Optical Fiber Distributed Temperature Sensors - ASI Project Summary

The goal of this work is to investigate the performance of sapphire optical fiber temperature sensors and develop clad sapphire optical fibers for in-pile instrumentation. This work tests the distributed sensing performance of sapphire sensors by using optical backscatter reflectometry methods under combined radiation/temperature effects and high fluence. A series of irradiations will be completed to evaluate the effect of irradiation on sapphire optical fiber temperature sensors and to determine an operational limit for the sensors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Fluence Active Irradiation and Combined Effects Testing of Sapphire Optical Fiber Distributed Temperature Sensors

Investigate the in-pile performance of sapphire optical fiber temperature sensors and to develop clad sapphire optical fibers for in-pile instrumentation. Evaluate the distributed sensing performance of the sensors through optical backscatter reflectometry under combined radiation and temperature effects, and high fluence.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fe-Coated Optical Fiber for Distributed Corrosion Monitoring in Soil and Aqueous Environments

Natural gas pipeline corrosion represents a substantial cost and safety concern during normal operations. The effective and real-time monitoring of corrosion is important to detect and mitigate pipeline risks before corrosion-related catastrophic events happen. Here, we describe the use of iron (Fe) coated optical fiber sensors (OFS) for distributed corrosion monitoring where Fe acts as a corrosion proxy. By using an optical backscattering reflectometer (OBR), corrosion was monitored based on the increase in the backscattered intensity amplitude of the light being passed as Fe underwent corrosion. The Fe-coated OFSs were prepared with a film thickness between 25–225 nanometers (nm) by an electroless plating approach and corroded by a carbon dioxide (CO2)-saturated acidic electrolyte. The corrosion rate (CR) was approximately 2.5 millimeters (mm)/year for Fe with a film thickness of 30 nm and increased with film thickness. Backscattering-based CRs were supported by visible light transmission measurements, which have been previously demonstrated. Additionally, a correlation between the intermittent transmission and residual Fe film thickness during the corrosion of Fe was established. The corrosion was measurable out to > 100 meters (m), which is a significant improvement over our previous work, which showed corrosion sensing at < 10 m. The corrosion sensor was also tested in soil at > 1 foot depth.

aqueous environment↗

Fe-Coated Optical Fiber for Distributed Corrosion Monitoring in Soil and Aqueous Environments

Natural gas pipeline corrosion represents a substantial cost and safety concern during normal operations. The effective and real-time monitoring of corrosion is important to detect and mitigate pipeline risks before corrosion-related catastrophic events happen. Here, we describe the use of iron (Fe) coated optical fiber sensors (OFS) for distributed corrosion monitoring where Fe acts as a corrosion proxy. By using an optical backscattering reflectometer (OBR), corrosion was monitored based on the increase in the backscattered intensity amplitude of the light being passed as Fe underwent corrosion. The Fe-coated OFSs were prepared with a film thickness between 25–225 nanometers (nm) by an electroless plating approach and corroded by a carbon dioxide (CO2)-saturated acidic electrolyte. The corrosion rate (CR) was approximately 2.5 millimeters (mm)/year for Fe with a film thickness of 30 nm and increased with film thickness. Backscattering-based CRs were supported by visible light transmission measurements, which have been previously demonstrated. Additionally, a correlation between the intermittent transmission and residual Fe film thickness during the corrosion of Fe was established. The corrosion was measurable out to > 100 meters (m), which is a significant improvement over our previous work, which showed corrosion sensing at < 10 m. The corrosion sensor was also tested in soil at > 1 foot depth.

corrosion↗

Fe-Coated Optical Fiber for Distributed Corrosion Monitoring in Soil and Aqueous Environment

Natural gas pipeline corrosion represents a substantial cost and safety concern during normal operations. The effective and real-time monitoring of corrosion is important to detect and mitigate pipeline risks before corrosion-related catastrophic events happen. Here, we describe the use of iron (Fe) coated optical fiber sensors (OFS) for distributed corrosion monitoring where Fe acts as a corrosion proxy. By using an optical backscattering reflectometer (OBR), corrosion was monitored based on the increase in the backscattered intensity amplitude of the light being passed as Fe underwent corrosion. The Fe-coated OFSs were prepared with a film thickness between 25–225 nanometers (nm) by an electroless plating approach and corroded by a carbon dioxide (CO2)-saturated acidic electrolyte. The corrosion rate (CR) was approximately 2.5 millimeters (mm)/year for Fe with a film thickness of 30 nm and increased with film thickness. Backscattering-based CRs were supported by visible light transmission measurements, which have been previously demonstrated. Additionally, a correlation between the intermittent transmission and residual Fe film thickness during the corrosion of Fe was established. The corrosion sensor was also tested in soil at > 1 foot depth. Fe-coated OFS was loaded into a Draka cable, which provides mechanical support during fiber deployment and installation into either acidified soil, top-soil, or sandy soil (50/50).

corrosion↗

Fe Coated Optical Fiber for Distributed Corrosion Monitoring in Soil and Aqueous Environment

Natural gas pipeline corrosion represents a substantial cost and safety concern during normal operations. Effective monitoring of corrosion is important to detect and mitigate pipeline risks before corrosion-related catastrophic events happen. Here, we describe the use of Fe-coated optical fiber sensors (OFS) for distributed corrosion monitoring where Fe acts as a corrosion proxy. By using an optical backscatterring reflectometer (OBR), corrosion was monitored based on the increase in backscattered intensity amplitude of the light being passed as Fe undergoes corrosion. The Fe-coated OFSs were prepared with a film thickness between 25-225 nm by an electroless plating approach and corroded by a CO2-saturated acidic electrolyte. The corrosion rate was approximately 2.5 mm/yr for Fe with a film thickness of 30 nm and increased with film thickness. Backscattering-based corrosion rates were supported by visible light transmission measurements, which have been previously demonstrated. Additionally, a correlation between the intermittent transmission and residual Fe film thickness during corrosion of Fe was established. Corrosion was measurable out to > 100 m which is a significant improvement over our previous work showing corrosion sensing at < 10 m. The corrosion sensor was also tested in soil at >1 ft depth. Fe-coated OFS was loaded into a Draka cable which provides mechanical support during fiber deployment and installation into either acidified soil, top-soil, or sandy soil.

aqueous environment↗

High Speed, Localized Multi-Point Strain Measurements on a Containment Vessel at 1.7 MHz Using Swept-Wavelength Laser-Interrogated Fiber Bragg Gratings

Dynamic elastic strain in ~1.8 and 1.0 m diameter containment vessels containing a high explosive detonation was measured using an array of fiber Bragg gratings. The all-optical method, called real-time localized strain measurement, recorded the strain for 10 ms after detonation with additional measurements being sequentially made at a rate of 1.7 MHz. A swept wavelength laser source provided the repetition rate necessary for such high-speed measurements while also providing enough signal strength and bandwidth to simultaneously measure 8 or more unique points on the vessel’s surface. The data presented here arethen compared with additional diagnostics consisting of a fast spectral interferometer and an optical backscatter reflectometer to show a comparison between the local and global changes in the vessel strain, both dynamically and statically to further characterize the performance of the localized strain measurement. The results are also compared with electrical resistive strain gauges and finite element analysis simulations.

47 OTHER INSTRUMENTATION↗

Calcined Polyethyleneimine Coated Optical Fibers for Distributed pH Monitoring at High Pressures and Temperatures

In the oil and gas, CO2 sequestration, H2 subsurface storage, and geothermal energy sectors, subsurface pH measurements are critical for monitoring the geochemical conditions and estimating potential corrosion rates of wellbore systems. Real-time pH measurements in these conditions are vital for detecting and predicting corrosion deterioration of wellbore components that may jeopardize the safety and continued operation of wellbore systems. Building off of earlier TiO2 based pH sensors and the known pH sensitivity of amine-based polymers, a coating based on the secondary amine polymer polyethyleneimine (PEI) was developed. The sensor coating was treated with a high temperature (500 °C) calcination procedure in air to convert it into a more stable oxidized coating capable of withstanding hot aqueous solutions without dissolving while retaining linear pH sensitivity from pH values between 2 and 11. The sensor performance was measured using optical transmission measurements in solutions of various pHs and using optical backscatter reflectometry for distributed pH sensing demonstration in wellbore-relevant pressures (up to 1000 psi) and temperatures (80 °C). A calibration curve with strong differentiation between acidic and alkaline pH was developed for both transmission-based and distributed pH measurements, using fixed wavelength transmission and integrated linear amplitude of backscattered light for distributed measurements.

Shumski, Alexander↗

Calcined Polyethyleneimine-Coated Optical Fibers for Distributed pH Monitoring at High Pressures and Temperatures

In the oil and gas, CO2 sequestration, H2 subsurface storage, and geothermal energy sectors, subsurface pH measurements are critical for monitoring the geochemical conditions and estimating potential corrosion rates of wellbore systems. Real-time pH measurements in these conditions are vital for detecting and predicting corrosion deterioration of wellbore components that may jeopardize the safety and continued operation of wellbore systems. Previous tests using metal oxide-based coatings (TiO2) provided strong responses at elevated temperatures and moderate pressure stability but provided poor differentiation between acidic and alkaline solutions. Building off the pH responsiveness of the TiO2 surface and known pH sensitivity of amine-based polymers, a coating based on the secondary amine polymer polyethyleneimine (PEI) was developed. As the polymer itself is highly water soluble and easily removed by aqueous solutions, the sensor coating was treated with a high temperature (500 °C) calcination procedure in air to convert it into a more stable oxidized coating capable of withstanding hot aqueous solutions without dissolving while retaining linear pH sensitivity from pH values between 2 and 11. The sensor performance was measured using optical transmission measurements in solutions of various pHs and using optical backscatter reflectometry for distributed pH sensing demonstration in wellbore-relevant pressures (up to 1,000 psi) and temperatures (80 °C).

Shumski, Alexander↗