Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical dilatometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Status of the Optical Dilatometer Method of Evaluating the Peak Irradiation Temperatures of SiC Passive Monitors

The main objective of this project was to conduct a comparative assessment between the optical dilatometer method and resistivity method, using all 10 SiC temperature monitors provided by two Nuclear Science User Facility experiments: BSU-8242 and General Electric Hitachi. Unfortunately, due to multiple delays in acquiring, shipping, and cleaning the SiC temperature monitors, the project was only able to process one (1) SiC temperature monitor during this period. SiC temperature monitor KGT-3357 was evaluated via the optical dilatometer method to determine its peak irradiation temperature. The KGT-3357 sample was from the BSU-8242 experiment and designed for a temperature of 300°C and an exposure of 1 dpa. The optical dilatometer measurements indicated that the KGT-3357 SiC temperature monitor’s peak irradiation temperature range was 240–267°C, with sensitivity of approximately ±20°C. Additionally, this temperature range falls within the evaluated melt wire temperature range of 238.6–271.5 °C. The remaining six (6) SiC temperature monitors from the BSU-8242 experiment and three (3) from the General Electric Hitachi experiment will be used in the future work to further validate the optical dilatometer method for measuring SiC peak irradiation temperatures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessment of Readout Techniques for Passive Monitors

This fiscal year (FY) 2023 report on passive temperature sensors covers two main objectives: to demonstrate that the optical dilatometer can successfully process disc shaped silicon carbide (SiC) temperature monitors (TMs), and to demonstrate proof of concept for using the capacitance readout method to read printed melt wires. The SiC objective was successfully met by annealing and analyzing, via optical dilatometry, all eight 3-mm SiC discs provided by the Nuclear Science User Facilities (NSUF) Idaho State University (ISU) Nanostructured Steels for Enhanced Radiation Tolerance (N SERT) experiment, which was irradiated at Idaho National Laboratory (INL)’s Advanced Test Reactor (ATR). Per the ISU N SERT experiment, capsule 1 (KGT 3828 1 and KGT 3828-2) had a design temperature of 300°C +/- 50°C and an exposure of 2 dpa +/- 10%; capsule 2 (KGT 4600 and KGT 4609) had a design temperature of 300°C +/- 50°C and an exposure of 6 dpa +/- 10%; capsule 3 (KGT 4639 C and KGT 4639-D) had a design temperature of 500°C +/- 50°C and an exposure of 6 dpa +/- 10%; and capsule 4 (KGT 3841 3 and KGT 3841 4) had a design temperature of 500°C +/- 50°C and an exposure of 2 dpa +/- 10%. The target exposure rates, in dpa, are the neutron damage for various types of nanostructured steels. All but three SiC TMs (KGT 4600, KGT 4639 D, and KGT 3841 4) revealed averaged peak irradiation temperatures that fell within the design temperature ranges. The three SiC TMs that did not fall within the design temperatures ranges were at least 100°C below that target temperature. Furthermore, SiC TM KGT 3841 C revealed two irradiation regimes: one closer to the 300°C design temperature, and the other closer to the 500°C design temperature. Also, all the SiC TMs’ averaged peak irradiation temperatures came in anywhere between 20°C and 240°C below the irradiation temperatures predicted by the thermal models. This showed the optical dilatometry method to be a reliable and less time intensive process for determining averaged peak irradiation temperatures from passive SiC TMs such as rods and discs. Under the Advanced Sensors and Instrumentation (ASI) program in FY-23, Boise State University (BSU) proposed to demonstrate proof of concept for using a capacitance readout technique applicable to printed melt wires; however, they were stymied by the complexity of the capacitance readout method. In support of the BSU work, INL developed an additively manufactured (AM) ceramic package for encapsulating the new melt wires. Inks were synthesized at BSU that used new protocols rather than following previously established protocols implemented at INL, and testing of various temperatures was conducted at BSU to evaluate the melting behaviors of the printed melt wires. The result was that the capacitance readout technique showed promise but also created more challenges than originally anticipated. For example, the tin ink synthesized at BSU showed unusual melting behaviors that did nothing to enhance the performance of the final printed melt wire prototype in terms of the capacitance readout method. To make the proof of concept work when applied to the printed melt wires, the ASI program would need to invest further resources and time. Consequently, the program is not planning to continue this proof of concept work in FY-24, based on the progress and findings achieved in FY-23.

36 MATERIALS SCIENCE↗

Benchmark Analysis for the Optical Dilatometry Method Using Silicon Carbide Temperature Monitors

The main objective of this project was to conduct a benchmark analysis for the optical dilatometry method by using NSUF’s SiC temperature monitors: two (2) SiC temperature monitors provided by NSUF’s BSU-8242 experiment and two (2) SiC temperature monitors provided by NSUF’s GE-Hitachi experiment. Per the BSU-8242 experiment, KGT-3597 and KGT-3591 had a design temperature of 400°C and an exposure of 3 dpa. Per the GE-Hitachi experiment, KGT-3341 and KGT-3336 had a design temperature of 290°C +/- 50°C and an exposure of 0.5–1 dpa. The KGT-3336 SiC monitor was split into two pieces during the decontamination process, making the dilatometry method the only way to analyze both those pieces. The BSU-8242 monitors revealed peak irradiation temperatures under the design temperature, and the GE-Hitachi monitors revealed peak irradiation temperatures within the design temperature range. The optical dilatometry method measured the peak irradiation temperature of BSU-8242 KGT-3597 to be 330°C, while the resistivity method measured the peak irradiation temperature of BSU-8242 KGT-3591 to be 320°C +/- 20°C. The optical dilatometry method measured the peak irradiation temperatures of the pieces of GE-Hitachi KGT-3336 to be 260°C (for the larger piece) and 220°C (for the smaller piece), while the resistivity method measured the peak irradiation temperature of GE-Hitachi KGT-3341 to be 300°C, with an accuracy range of -50°C to +20°C. Both methods of SiC temperature monitor analysis produced very similar peak irradiation temperatures for each pair of SiC passive monitors from the two experiments, BSU-8242 and GE-Hitachi. The results show dilatometry method to be a reliable and less time-intensive process for determining irradiation temperatures from passive SiC thermometry.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Silicon Carbide Passive Temperature Sensors at INL

Discuss the SiC passive thermometry methods currently performed at INL and ORNL, decide on best path forward for establishing an ASTM Standard for processing SiC temperature monitors, and expand this ASTM benchmarking efforts to international collaborators (Netherlands, Canada, and Poland).

36 MATERIALS SCIENCE↗

Effect of heat treatments on discontinuous precipitation kinetics in Al-30 wt.% Zn alloy

The discontinuous precipitation kinetics in Al-30% wt. Zn alloy have been investigated at temperatures ranging from 348 to 503 K (75 to 230 deg. C) by using an optical microscopy, X-ray diffraction, differential dilatometer, differential scanning calorimetry and microhardness measurement. We have found that at all temperatures less than 180 deg. C the supersaturated solid solution of quenched alloy was observed to decompose completely by a cellular precipitation reaction. Quantitative metallography methods have been applied to measure the corresponding transformed volume fractions at different temperatures and times of precipitation. The variation of the heating rate and the application of different methods have allowed us to calculate two kinetic parameters of precipitation: the activation energy of the process and the Avrami exponent.

36 MATERIALS SCIENCE↗

Photoinduced Reversible Local Deformation of the Surface Relief in Bulk Single Crystals of TlInSe{sub 2}, TlGaTe{sub 2}, and TlSe

Giant macroscopic expansion of the surface relief, localized within a laser spot size, has been observed in bulk single crystals of TlInSe{sub 2}, TlGaTe{sub 2}, and TlSe at room temperature and laser radiation densities lower by at least two orders of magnitude than the material optical damage threshold. Quantitative estimations of the deformation magnitude in this local region were obtained using an interference dilatometer. The photon absorption length was determined with the aid of spectroscopic ellipsometry. It is established that the surface deformation amounts to 2.6 × 10{sup –3} at a laser radiation intensity of 19 mW/mm{sup 2}. The observed phenomenon has a thermal nature and is probably related to a low thermal conductivity of the materials studied.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High Throughput Coefficient Thermal Expansion Testing Utilizing Digital Image Correlation

Dr. Fitzgerald, a postdoc at Sandia National Laboratories, works in a materials of mechanics group characterizing material properties of ductile materials. Her presentation focuses specifically on increasing throughput of coefficient of thermal expansion (CTE) measurements with the use of optical strain measurements, called digital image correlation (DIC). Currently, the coefficient of thermal expansion is found through a time intensive process called dilatometry. There are multiple types of dilatometers. One type, a double push rod mechanical dilatometer, uses and LVDT to measure the expansion of a specimen in one direction. It uses a reference material with known properties to determine the CTE of the specimen in question. Testing about 500 samples using the double push rod mechanical dilatometer would take about 2 years if testing Monday through Friday, because the reference material needs to be at a constant temperature and heating must done slowly to ensure no thermal gradients across the rod. A second type, scissors type dilatometer, pinches a sample using a “scissor-like” appendage that also uses a LVDT to measure thermal expansion as the sample is heated. Finally, laser dilatometry, was created to provide a non-contact means to measure thermal expansion. This process greatly reduces the time required to setup a measurement but is still only able to measure one sample at a time. The time required to test 500 samples gets reduced to 3.5 weeks. Additionally, to measure expansion in different directions, multiple lasers must be used. Dr. Fitzgerald solved this conundrum by using an optical measurement technique called digital image correlation to create strain maps in multiple orientations as well as measuring multiple samples at once. Using this technique, Dr. Fitzgerald can test 500 samples, conservatively, in 2 days.

36 MATERIALS SCIENCE↗

Synthesis and characterization of low softening point high Bi{sub 2}O{sub 3} glasses in the K{sub 2}O-B{sub 2}O{sub 3}-Bi{sub 2}O{sub 3} system

Synthesis of a new series of lead free low softening point (< 470 deg. C) high Bi{sub 2}O{sub 3} (40-90 mol%) glasses in the K{sub 2}O-B{sub 2}O{sub 3}-Bi{sub 2}O{sub 3} system by the melt-quench technique has been demonstrated here. Their structural, optical, thermal, electrical and other physical properties have been evaluated by X-ray diffraction (XRD), transmission electron microscopy (TEM), field emission scanning electron microscopy (FESEM), FT-infrared reflection (FTIRR) spectroscopy, UV-Visible spectroscopy, dilatometer, LCR meter, etc. techniques. The glass softening point, glass transition temperature and glass deformation temperature are found to vary in the ranges 410-465 deg. C, 354-409 deg. C and 376-427 deg. C respectively which are found to correlate well with the boron anomaly phenomenon (as revealed by FTIRRS) with gradual addition of Bi{sub 2}O{sub 3} in the glass matrix. The coefficient of thermal expansion shows a decreasing trend from 153 down to 109 x 10{sup -7} K{sup -1} whereas the dielectric constant increases from 21 to 34 with the increase in Bi{sub 2}O{sub 3} content. The theoretical optical basicity is found to increase from 0.93 to 1.15 while the optical band gap decreases from 2.86 down to 2.30 eV with the addition of Bi{sub 2}O{sub 3}. The formation of metallic bismuth in these glasses during melting in air has been confirmed by the XRD, TEM, selected area electron diffraction (SAED) and high resolution TEM (HRTEM) analyses. The formation of a Bi{sub 2}O{sub 3} rich secondary phase in the glasses and their particle size distribution have been examined by the FESEM photomicrograph analysis. - Research Highlights: {yields} Synthesis of low softening point (< 470 deg. C) high Bi{sub 2}O{sub 3} content (40-90 mol%) glasses. {yields} Study of boron anomaly phenomenon with gradual addition of Bi{sub 2}O{sub 3} in the glass. {yields} Co-efficient of thermal expansion decreases from 153 to 109 x 10{sup -7} K{sup -1}. {yields} Dielectric constant increases from 21 to 34 with increase in Bi{sub 2}O{sub 3} content. {yields} Formation of metallic bismuth in the glass confirmed by the XRD and TEM analyses.

36 MATERIALS SCIENCE↗