Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical fiber plasma”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

First demonstration of a fiber optic bolometer on a tokamak plasma (invited)

A fiber optic bolometer (FOB) was demonstrated observing a fusion plasma for the first time at the DIII-D tokamak. A FOB uses a fiber optics-based interferometric technique that is designed to have a high sensitivity to temperature changes [75 mK/(W/m2) responsivity in high vacuum with 0.38 mK noise level] with a negligible susceptibility to electromagnetic interference (EMI) that can be problematic for resistive bolometers in a tokamak environment. A single-channel test apparatus was installed on DIII-D consisting of a measurement FOB and shielded reference FOB. The single-channel FOB showed a negligible increase in the noise level during typical plasma operations (0.39 mK) compared to the benchtop results (0.38 mK), confirming an insignificant EMI impact to the FOB. Comparisons to DIII-D resistive bolometers showed good agreement with the single-channel FOB, indicating that the FOB is comparable to a resistive bolometer when the impulse calibration is applied. The noise-equivalent power density of the calibrated FOB during a plasma operation was 0.55 W/m2 with an average sampling time of 20 ms. The major potential effect of ionizing radiation on the FOB would be the radiation-induced attenuation, which can be efficiently compensated for by adjusting the probing light power.

Lee, S. (ORCID:0000000170289004)↗

Detailed measurements of the H beta line shape in a transient plasma using a fiber optics slit system

Through the use of fiber optics, a series of very narrow slits have been constructed and placed at the exit plane of a spectrograph. Plasma radiation which is dispersed by the spectrograph is incident on the slits and is transmitted to separate phototubes via the quartz fibers. With this technique, time resolved measurements of the spectral shape of the hydrogen H beta line have been made and used to determine the electron density of a transient plasma. Data obtained in a shock tube indicated that the thermodynamic conditions behind the reflected shock in a mixture of 20 percent H 80 percent He correspond to theoretically predicted conditions.

Stickford, G. H., Jr.↗

Detailed measurements of the H beta line shape in a transient plasma using a fiber optics slit system.

Through the use of fiber optics, a series of very narrow slits have been constructed and placed at the exit plane of a spectrograph. Plasma radiation which is dispersed by the spectrograph is incident on the slits and is transmitted to separate phototubes via the quartz fibers. With this technique, time resolved measurements of the spectral shape of the hydrogen H beta line have been made and used to determine the electron density of a transient plasma. Data obtained in a shock tube indicated that the thermodynamic conditions behind the reflected shock in a mixture of 20% H2-80% He, at incident shock speeds of 12 to 14 km/sec and pressures of 66.6 to 133.3 N/sq m (0.5 to 1.0 mm Hg), correspond to theoretically predicted conditions. Immediately behind the incident shock at speeds of 17 to 24 km/sec the data indicate that the plasma reached equilibrium then demonstrated a drop in intensity which has been attributed to radiative cooling.

Stickford, G. H., Jr.↗

Fiber-optic bolometers with high-temperature tolerance and reduced time constants for fusion plasma diagnostics

Fiber-optic bolometers (FOBs) designed for plasma radiation measurement in magnetically confined fusion environments have been previously developed and tested at the DIII-D tokamak. These FOBs utilize a silicon Fabry–Perot interferometer at the fiber tip for temperature measurement and a gold disk as a radiation absorber. This paper presents recent advancements in the development of FOBs with reduced cooling time constants and enhanced temperature tolerance. We also demonstrate high-temperature operation and report findings from irradiation tests. By incorporating a copper sensor holder as a thermal sink and integrating two closely packed sensor heads into a compact design, the cooling time constants were reduced to ∼100 ms in vacuum, while minimizing uncertainties caused by temperature gradients. The FOBs were subjected to heating at 400 °C for five hours, with no observed degradation in noise performance post-heating. High-temperature operation tests were conducted at ∼220 °C using a 404 nm square-wave modulated laser to simulate the plasma radiation. In addition, four FOBs constructed from copper-coated pure-silica fibers were fabricated and underwent irradiation testing, enduring a total γ-radiation dose of 15.2 MGy and a neutron fluence of 1.6 × 10 18 n/cm 2 . As a result, the FOBs maintained their physical integrity and the optical signal shows high visibility throughout the test.

42 ENGINEERING↗

Experimentally Determined Plasma Parameters in a 30 cm Ion Engine

Single planar Langmuir probes and fiber optic probes are used to concurrently measure the plasma properties and neutral density variation in a 30cm diameter ion engine discharge chamber, from the immediate vicinity of the keeper to the near grid plasma region. The fiber optic probe consists of a collimated optical fiber recessed into a double bore ceramic tube fitted with a stainless steel light-limiting window. The optical fiber probe is used to measure the emission intensity of excited neutral xenon for a small volume of plasma, at various radial and axial locations. The single Langmuir probes, are used to generate current-voltage characteristics at a total of 140 spatial locations inside the discharge chamber. Assuming a maxwellian distribution for the electron population, the Langmuir probe traces provide spatially resolved measurements of plasma potential, electron temperature, and plasma density. Data reduction for the NSTAR TH8 and TH15 throttle points indicates an electron temperature range of 1 to 7.9 eV and an electron density range of 4e10 to le13 cm(sup -3), throughout the discharge chamber, consistent with the results in the literature. Plasma potential estimates, computed from the first derivative of the probe characteristic, indicate potential from 0.5V to 11V above the discharge voltage along the thruster centerline. These values are believed to be excessively high due to the sampling of the primary electron population along the thruster centerline. Relative neutral density profiles are also obtained with a fiber optic probe sampling photon flux from the 823.1 nm excited to ground state transition. Plasma parameter measurements and neutral density profiles will be presented as a function of probe location and engine discharge conditions. A discussion of the measured electron energy distribution function will also be presented, with regards to variation from pure maxwellian. It has been found that there is a distinct primary population found along the thruster centerline, which causes estimates of electron temperature, electron density, and plasma potential, to err on the high side, due this energetic population. Computation of the energy distribution fimction of the plasma clearly indicates the presence of primaries, whose presence become less obvious with radial distance from the main discharge plume.

near grid plasma↗

Embedding Fiber Optic Sensors in Stainless Steel using Spark Plasma Sintering for Structural Health Monitoring in Harsh Environments

Embedded fiber optic sensors such as fiber Bragg gratings (FBGs) offer a unique route for distributed real-time in-situ imaging of various engineering parameters for numerous purposes. This study advanced the current sensor embedding approaches by exploring a spark plasma sintering (SPS)-assisted technology to embed FBGs in high-temperature structural materials and demonstrated the capability of temperature measurement. In this approach, single-mode FBGs were integrated into stainless steel (SS) 316L components using SPS, followed by the evaluation of the bonding quality between the FBGs and matrix, the optical attenuation of the fibers induced by embedding, and the sensing characters of the FBGs under temperature stimuli. The results demonstrated that superior bonding was achieved between the FBGs and highly-densified SS316L. Examination of the behavior of Bragg gratings validated signal fidelity after embedding. Real-time thermal imaging under temperature cycling using the FBGs demonstrated the effectiveness of the technique for smart materials manufacturing.

36 - MATERIALS SCIENCE↗

Multichannel Fiber-Optic Silicon Fabry–Pérot Interferometric Bolometer System for Plasma Radiation Measurements

A single-channel fiber-optic bolometer system based on a high-finesse silicon Fabry–Pérot interferometer (FPI) was previously reported, intended to measure plasma radiation from the magnetically confined fusion chamber. Recently, we developed a multichannel fiber-optic bolometer system with five bolometers multiplexed using a coarse wavelength division multiplexer (CWDM) and interrogated with a white-light system involving a superluminescent light-emission diode source and a high-speed spectrometer. One of the bolometers was used as the reference bolometer to compensate for the ambient temperature variations, and the other four bolometers were used for radiation measurement. The bolometers have a simple structure with a silicon pillar at the end of the single-mode fiber and a gold disk on the other side of the silicon pillar. They are also easy to fabricate without stringent requirements on the optical alignment. Analysis of the system optimization was performed to improve the noise performance and to mitigate the vibration effect that may present in the practical application. The system had a significantly enhanced measurement range compared to the previous high-finesse FPI bolometer system for measuring radiation. Test results performed in air using a 405 nm laser as the radiation source showed that the temperature resolution and the noise-equivalent power density of the sensing bolometers connected to each channel of the CWDM were, respectively, ~0.4 mK and ~0.1 W/m2, with a time constant of ~220 ms, which is comparable to the previous more complicated fiber-optic bolometer systems based on high-finesse FPIs that were interrogated using wavelength-scanning lasers.

Uddin, Nezam↗

Spatio-temporal ion temperature and velocity measurements in a Z pinch using fast-framing spectroscopy

Ion Doppler spectroscopy (IDS) is a diagnostic technique that measures plasma ion temperature and velocity without perturbing the plasma with a physical probe. The ZaP-HD Flow Z-Pinch Experiment at the University of Washington uses this technique to resolve radial temperature and velocity profiles of a Z-pinch plasma. The pinch lifetime is approximately 100 ms, therefore diagnostics capable of sub-microsecond resolution are required to measure the evolution of temperature and velocity profiles. The previous IDS diagnostic system was only capable of collecting a single measurement during a plasma pulse. Here, an improved system has been developed to measure radially-resolved ion temperature and velocity for the entire Z-pinch lifetime. A Kirana 05M ultra-fast framing camera and SIL ultraviolet intensifier are used to record up to 100 spectra per plasma pulse. The temperature is computed from Doppler broadening of the carbon-III (229.687 nm) impurity ion radiation and the velocity from the Doppler shift of carbon-III. Measurements are able to resolve the evolution of the ion temperature and velocity over the course of a plasma pulse. The diagnostic has significantly reduced the number of pulses required and provides a more coherent measurement of plasma dynamics than the previous system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Longitudinal shaping of plasma waveguides using diffractive axicons for laser wakefield acceleration

New techniques for the optical generation of plasma waveguides—optical fibers for ultra-intense light pulses—have become vital to the advancement of multi-GeV laser wakefield acceleration. Here, we demonstrate the fabrication and characterization of a transmissive 8-level logarithmic diffractive axicon (LDA) for the generation of meter-scale plasma waveguides. These LDAs enable the formation of a Bessel-like beam with controllable start and end locations of the focal line and near-constant intensity on axis. We present measurements of the Bessel-like focal profile produced by the LDA and of the leading end of the plasma column generated by it. One important feature is the formation of a funnel-mouthed plasma channel entrance that can act as waveguide coupler. We also compare the diffraction efficiency of our 8-level LDA to 4-level and binary versions, with measurements comparing well to theory.

Tripathi, N.↗

Charge exchange recombination spectroscopy at Wendelstein 7-X

The Charge Exchange Recombination Spectroscopy (CXRS) diagnostic has become a routine diagnostic on almost all major high temperature fusion experimental devices. For the optimized stellarator Wendelstein 7-X (W7-X), a highly flexible and extensive CXRS diagnostic has been built to provide high-resolution local measurements of several important plasma parameters using the recently commissioned neutral beam heating. This paper outlines the design specifics of the W7-X CXRS system and gives examples of the initial results obtained, to include typical ion temperature profiles for several common heating scenarios, toroidal flow and radial electric field derived from velocity measurements, beam attenuation via beam emission spectra, and normalized impurity density profiles under some typical plasma conditions.

47 OTHER INSTRUMENTATION↗

NASA Tech Briefs, July 2007

Topics covered include: Miniature Intelligent Sensor Module; "Smart" Sensor Module; Portable Apparatus for Electrochemical Sensing of Ethylene; Increasing Linear Dynamic Range of a CMOS Image Sensor; Flight Qualified Micro Sun Sensor; Norbornene-Based Polymer Electrolytes for Lithium Cells; Making Single-Source Precursors of Ternary Semiconductors; Water-Free Proton-Conducting Membranes for Fuel Cells; Mo/Ti Diffusion Bonding for Making Thermoelectric Devices; Photodetectors on Coronagraph Mask for Pointing Control; High-Energy-Density, Low-Temperature Li/CFx Primary Cells; G4-FETs as Universal and Programmable Logic Gates; Fabrication of Buried Nanochannels From Nanowire Patterns; Diamond Smoothing Tools; Infrared Imaging System for Studying Brain Function; Rarefying Spectra of Whispering-Gallery-Mode Resonators; Large-Area Permanent-Magnet ECR Plasma Source; Slot-Antenna/Permanent-Magnet Device for Generating Plasma; Fiber-Optic Strain Gauge With High Resolution And Update Rate; Broadband Achromatic Telecentric Lens; Temperature-Corrected Model of Turbulence in Hot Jet Flows; Enhanced Elliptic Grid Generation; Automated Knowledge Discovery From Simulators; Electro-Optical Modulator Bias Control Using Bipolar Pulses; Generative Representations for Automated Design of Robots; Mars-Approach Navigation Using In Situ Orbiters; Efficient Optimization of Low-Thrust Spacecraft Trajectories; Cylindrical Asymmetrical Capacitors for Use in Outer Space; Protecting Against Faults in JPL Spacecraft; Algorithm Optimally Allocates Actuation of a Spacecraft; and Radar Interferometer for Topographic Mapping of Glaciers and Ice Sheets.

Source record↗

Multichannel Doppler fiber-imager spectrometer for spatiotemporal characterization of high-intensity laser-driven plasmas

Here, we demonstrate a flexible multichannel fiber-based imaging Doppler spectrometer to characterize plasmas in high intensity (≥1 × 10 18 W/cm 2 ) laser-plasma experiments at high repetition rates. This instrument collects data from ×21 different plasma locations combining optical fibers and a single imaging spectrometer. This diagnostic maps the plasma velocity evolution as a function of time with sub-pico-second resolution. Experimental results showing 2D velocity measurements of plasma with 20 μm spatial resolution are presented. Intensities of the order of 10 18 W/cm 2 were used to generate a plasma, while a much less intense, frequency doubled (400 nm), probe beam (10 11 W/cm 2 ) was used to measure the Doppler shift from the plasma critical surface. The instrument can be scaled to a larger number of channels (e.g., 100) still using a single spectrometer.

47 OTHER INSTRUMENTATION↗

Fiber-Optic Bolometer and Calorimeter Arrays for Magnetically Confined Plasmas

Bolometers measure the plasma radiation and provide essential diagnostic information both for safe, sustainable operation of magnetic-confinement fusion (MCF) devices and for study of the relevant physics. The fusion community has been replying on resistive bolometers for plasma radiation measurement. However, their performance is greatly compromised by the strong electromagnetic interference present in MCF devices. Previously, we have demonstrated a fiber-optic bolometer that has the promise to overcome the challenges related to the strong EMI in the MCF environment. In this project, we study the performance of the fiber-optic bolometer in a simulated MCF environment and improved the sensitivity through a novel sensor design. Part of the work reported here was performed between 09/01-12/31/2017 when the PI was with University of Nebraska-Lincoln under the same project but with a different award number (DE-SC0018273).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Collective optical Thomson scattering in pulsed-power driven high energy density physics experiments (invited)

Optical collective Thomson scattering is used to diagnose magnetized high energy density physics experiments at the Magpie pulsed-power generator at Imperial College London. The system uses an amplified pulse from the 2nd harmonic of a Nd:YAG laser (3 J, 8 ns, 532 nm) to probe a wide diversity of hightemperature plasma objects; with densities in the range of 10 17 -10 19 cm -3 and temperatures between 10 eV and a few keV. The scattered light is collected from 100 μm-scale volumes within the plasmas, which are imaged onto optical fiber arrays. Multiple collection systems observe these volumes from different directions, providing simultaneous probing with different scattering K-vectors (and different associated α-parameters, typically in the range 0.5 – 3) allowing independent measurements of separate velocity components of the bulk plasma flow. The fiber arrays are coupled to an imaging spectrometer with a gated ICCD. The spectrometer is configured to view the ion-acoustic waves (IAWs) of the collective Thomson scattered spectrum. Fits to the spectra with the theoretical spectral density function S(K,ω) yield measurements of the local plasma temperatures and velocities. Fitting is constrained by independent measurements of the electron density from laser interferometry, and the corresponding spectra for different scattering vectors. Furthermore, this TS diagnostic has been successfully implemented on a wide range of experiments, revealing temperature and flow velocity transitions across magnetized shocks, inside rotating plasma jets and imploding wire arrays, as well as providing direct measurements of drift velocities inside a magnetic reconnection current sheet.

47 OTHER INSTRUMENTATION↗

Local Neutral Density and Plasma Parameter Measurements in a Hollow Cathode Plume

In order to understand the cathode and keeper wear observed during the Extended Life Test (ELT) of the DS1 flight spare NSTAR thruster and provide benchmarking data for a 2D cathode/cathode-plume model, a basic understanding of the plasma and neutral gas parameters in the cathode orifice and keeper region of the cathode plume must be obtained. The JPL cathode facility is instrumented with an array of Langmuir probe diagnostics along with an optical diagnostic to measure line intensity of xenon neutrals. In order to make direct comparisons with the present model, a flat plate anode arrangement was installed for these tests. Neutral density is deduced from the scanning probe data of the plasma parameters and the measured xenon line intensity in the optical regime. The Langmuir probes are scanned both axially, out to 7.0 cm downstream of the keeper, and radially to obtain 2D profile of the plasma parameters. The optical fiber is housed in a collimating stainless steel tube, and is scanned to view across the cathode plume along cuts in front of the keeper with a resolution of 1.5 mm. The radial intensities are unfolded using the Abel inversion technique that produces radial profiles of local neutral density. In this paper, detailed measurements of the plasma parameters and the local neutral densities will be presented in the cathode/keeper plume region for a 1.5 cm diameter NEXIS cathode at 25A of discharge current at several different strengths of applied magnetic field.

Plasma density↗

Ex situ calibration of the scattered-light time-history diagnostic on the National Ignition Facility

The scattered-light time-history diagnostic (SLTD) suite measures time-resolved scattered light in three wavelength bands: stimulated Brillouin scattering (350–352 nm), stimulated Raman scattering (430–760 nm), and plasma emission at half the laser frequency (695–735 nm), at 15 locations around the National Ignition Facility (NIF) target chamber. The SLTD, along with the full-aperture backscatter station (FABS), collects scattered light from direct- and indirect-drive inertial confinement fusion experiments. The SLTD calibration was revisited after a discrepancy between FABS and SLTD measurements was observed on NIF polar direct-drive experiments. An integrated calibration of the SLTD was performed for the first time, and individual components were also calibrated for the wavelengths of 351, 527, and 532 nm. The optical transmission of the instrument was measured to be (1.12 ± 0.04) × 10 –7 and (1.96 ± 0.11) × 10 –7 for the wavelengths of 351 and 532 nm, respectively. The revised calibration at 351 nm brings the SLTD measured scattered energy in agreement with the FABS measured scattered energy after additionally accounting for the degradation of an optical element in FABS. Furthermore, this decreased the inferred absorption by 7% for a representative experiment. However, discrepancies remain between FABS and SLTD measurements in the SRS band (532 nm).

47 OTHER INSTRUMENTATION↗

Optically multiplexed neutron time-of-flight technique for inertial confinement fusion

Neutron time-of-flight (nTOF) detectors are crucial in diagnosing the performance of inertial confinement fusion (ICF) experiments, which implode targets of deuterium–tritium fuel to achieve thermonuclear conditions. These detectors utilize the fusion neutron energy spectrum to extract key measurements, including the hotspot ion temperature and fuel areal density. Previous work [Danly et al., Rev. Sci. Instrum. 94, 043502 (2023)] has demonstrated adding 1D spatial resolution to an nTOF-like detector using a neutron aperture and streak camera to measure the ion temperature profile of an ICF implosion. By contrast, the study presented herein explores modifying the 1D detector to use a fast photomultiplier tube (PMT) to validate the design of a 2D spatially resolved instrument based on reconstruction from 1D profiles. The modification would collect time-of-flight traces from separate scintillators in an imaging array with one PMT using optical fibers of varying lengths to time-multiplex the signals. This technique has been demonstrated in ride-along experiments on the OMEGA laser with 20 fiber-coupled scintillator channels connected to a Photek PMT210. Results provide constraints on the fiber lengths and PMT gating requirements to promote pulse fidelity throughout all channels. Calibration of the detector to fixed nTOFs can provide a preliminary estimate of the instrument response function (IRF), although measurement of the IRF is currently under way. These results suggest that nTOF signals can potentially be time-multiplexed with fibers so long as the design is strategic to mitigate signal-to-noise reduction, modal dispersion, and charge build-up in the PMT, which has implications beyond ion temperature imaging.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗