Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical frequency standard laser stabilization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Radiofrequency synthesiser with an intrinsic instability of 5 × 10{sup −15} at the averaging time of 1 s based on a femtosecond erbium-doped fibre laser

A radio-optical synthesiser intended for operation in a radio-frequency master oscillator with an optical He – Ne/CH{sub 4} frequency standard (λ = 3.39 μm) is developed on the basis of a femtosecond erbium-doped fibre laser. The synthesiser generates equidistant harmonics in the frequency range of 1 – 10 GHz with stability determined by the optical frequency standard. A stable supercontinuum spectrum is formed in the range around 1.06 μm, which provides stable 24-hour operation of the synthesiser and is important for practical applications in off-laboratory conditions. A direct comparison of the output frequencies of two synthesisers shows that the up-grade of the fibre laser and detection system of femtosecond pulses results in the synthesiser intrinsic instability of 5 × 10{sup −15} at the averaging time of 1 s. Such a value is by an order of magnitude less than that obtained in our earlier works. (laser frequency standards)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Methane microwave optical master oscillator for fountain references

We have demonstrated a microwave master oscillator operating on optical principles and based on a He – Ne/CH{sub 4} optical frequency standard (λ = 3.39 μm) and femtosecond fibre laser system ( λ = 1.54 μm). The output signal spectrum of the oscillator has the form of an equidistant frequency comb in the range 60 MHz to 10 GHz with a 60-MHz step. Comparison of the frequencies of two master oscillators shows that the short-term output frequency instability for the comb components in the range 0.8 – 1.5 GHz is under 1 × 10{sup −14} at an averaging time of 1 s. We have tested microwave signals from the oscillator using apparatus in the reference facility at the State Time and Frequency Service, All-Russia Research Institute of Physical and Radio Engineering Measurements. A signal at a nominal frequency of 100 MHz synthesised from one comb component was compared to signals from two hydrogen masers with enhanced short-term stability in the reference facility. The short-term frequency stability of the synthesised signal has been shown to be twice better than the stability of the masers and to be limited by the intrinsic instability of the commercial synthesiser of a 100-MHz nominal frequency. Our experiments confirm that the proposed microwave optical master oscillator is potentially attractive for use in systems with increased requirements for short-term frequency stability, in particular in time and frequency fountain references. (optical frequency standards)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Frequency shift of an optical frequency standard as a function of probe modulation of the radiation frequency, pressure, and gas temperature in an absorbing cell

Frequency shifts of an optical Nd : YAG/I{sub 2}-standard are measured in a pressure range of molecular iodine 5 – 22 mTorr and deviation of probe modulation frequency 480 kHz – 4 MHz for the hyperfine structure component a1 of the molecular iodine absorption line R(56) 32 – 0. The frequency shift of the optical standard is estimated under varied temperatures of a cell and cell finger, which determines the pressure of the molecular iodine vapour. The requirements are defined to temperature stability of the cell and its finger for obtaining high long-term frequency stability of the optical frequency standard. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of a prototype compact fibre frequency synthesiser for mobile femtosecond optical clocks

A prototype compact fibre frequency synthesiser based on a femtosecond erbium fibre laser and an original hybrid highly nonlinear fibre is developed and preliminarily studied. This synthesiser will ensure an extremely low relative instability of synthesised frequencies (down to 10{sup -17}) with the use of a corresponding optical standard and will be used in mobile optical clocks. The realised frequency stabilisation principle makes the synthesiser universal and allows it to transfer the frequency stability of various types of optical standards to the synthesised radio- and optical frequencies. (extreme light fields and their applications)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Time domain simulations of arm locking in LISA

Arm locking is a proposed laser frequency stabilization technique for the Laser Interferometer Space Antenna (LISA), a gravitational-wave observatory sensitive in the milliHertz frequency band. Arm locking takes advantage of the geometric stability of the triangular constellation of three spacecraft that compose LISA to provide a frequency reference with a stability in the LISA measurement band that exceeds that available from a standard reference such as an optical cavity or molecular absorption line. We have implemented a time-domain simulation of a Kalman-filter-based arm-locking system that includes the expected limiting noise sources as well as the effects of imperfect a priori knowledge of the constellation geometry on which the design is based. We use the simulation to study aspects of the system performance that are difficult to capture in a steady-state frequency-domain analysis such as frequency pulling of the master laser due to errors in estimates of heterodyne frequency. We find that our implementation meets requirements on both the noise and dynamic range of the laser frequency with acceptable tolerances and that the design is sufficiently insensitive to errors in the estimated constellation geometry that the required performance can be maintained for the longest continuous measurement intervals expected for the LISA mission.

79 ASTRONOMY AND ASTROPHYSICS↗

New adaptive optics control strategy for petawatt-class laser chains

A new generation of ultra-high intensity femtosecond petawatt- and above-class lasers requires new approaches to wavefront corrections. New challenges for adaptive optics consist in overcoming the constraints of potentially bigger diameters, larger amplitude aberrations, faster optics, higher risk of damaging optical components and faster and easier maintenance. Here we present a new technology of a mechanical deformable mirror, which has a large stroke, high temporal stability, low hysteresis, no print-through effect, easy, safe and fast maintenance and an operating frequency up to 10 Hz. We propose the full correction of the final focal spot in the target chamber by a combination of a standard adaptive optics system, a simple focal plane camera and a phase retrieval correction process. We test the reliability of the correction system in terms of intensity variation and wavefront stability. We further verify correction robustness of the method on a large spectral bandwidth and finally perform a focal spot correction on a terawatt laser system in both low and high-power regimes. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

X-ray free-electron laser oscillator with nuclear-resonant cavity stabilization and quantum-optical applications

Here, x-ray free-electron-laser oscillators with nuclear-resonant cavity stabilization (NRS-XFELO) hold the promise for providing x-rays with unprecedented coherence properties that will enable interesting quantum-optical and metrological applications. Among these are atom optics with x-ray-based optical elements providing high momentum transfer, or a frequency standard far surpassing the best state-of the-art atomic clocks.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Molecular laser stabilization at low frequencies for the LISA mission

We have developed a 532 nm iodine stabilized laser system that may be suitable for the LISA mission (Laser Interferometer Space Antenna) or other future spaceborne missions. This system is based on an externally frequency-doubled Nd:YAG laser source and uses the molecular transfer spectroscopy technique for the frequency stabilization. This technique has been optimized for LISA: compactness (less than 1.1x1.1 m{sup 2}), vacuum compatibility, ease of use and initialization, minimization of the number of active components (acousto-optic modulators are both used for frequency shifting and phase modulating the pump beam). By locking on the a{sub 10} hyperfine component of the R(56)32-0 transition, we find an Allan standard deviation ({sigma}) of 3x10{sup -14} at 1 s and {sigma}<2x10{sup -14} for 20 s{<=}{tau}{<=}10{sup 3} s. In terms of linear spectral density, this roughly corresponds to a stability better than 30 Hz/{radical}(Hz) between 10{sup -2} and 1 Hz with a stability decrease close to 1/f below 10 mHz.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stabilisation of a fibre frequency synthesiser using acousto-optical and electro-optical modulators

A fibre-optic frequency synthesiser is developed that is stabilised to the optical frequency standard based on molecular iodine (Nd : YAG/I{sub 2}). The possibility of transferring stability of the optical frequency standard to other optical frequencies in the IR range 1−2 μm and to the RF range by using synthesiser phase-locked loops (PLLs) with acousto-optical and electro-optical modulators is experimentally demonstrated. The additive instability introduced into the optical frequency comb of the synthesiser (which arises due to PLL residual random errors) is several orders less than the intrinsic instability of the reference optical frequency standard employed (i.e., is noticeably less than 1×10{sup −13} for 1 s and 5×10{sup −15} for 1000 s). (paper)

42 ENGINEERING↗

Laser frequency stabilisation on narrow resonances of cold magnesium atoms at the {sup 1}S{sub 0} – {sup 3}P{sub 1} transition

Experimental studies aimed at developing an optical frequency standard based on ultracold magnesium atoms with a relative uncertainty of Δν/ν < 10{sup –16} are performed. The frequency of the clock laser system at a wavelength of 457 nm is stabilised to narrow optical resonances (Ramsey fringes) in time-separated laser fields interacting with cold magnesium atoms localised in a magneto-optical trap (MOT). The frequency stability of the laser system is investigated using a femtosecond comb based on a Ti:sapphire laser. Long-term frequency stability (determined by the Allan function) of ∼5 × 10{sup –15} at averaging time τ = 1000 s is obtained. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Selective laser pumping of magnetic sublevels in the hyperfine structure of the cesium atom

The evolution of the populations of the magnetic sublevels of the cesium atom ({sup 133}Cs isotope) in resonant laser fields with linear polarization is analyzed using the equations for the density matrix. Analytic expressions are derived for stationary populations resulting from laser-induced optical transitions on the hyperfine structure components F{sub g} = 3 ↔ F{sub e} = 2, 3 and F{sub f} = 4 ↔ F{sub e} = 3, 4 of lines D{sub 1} (6{sup 2}S{sub 1/2} → 6{sup 2}P{sub 1/2}) and D{sub 2} (6{sup 2}S{sub 1/2} → 6{sup 2}P{sub 3/2}) depending on the initial values of the populations. The numerical solution of the evolution equations gives the characteristic times of stabilization of the steady regime as functions of laser field intensities and detuning from optical resonance. We determine the sequences of optical transitions increasing (by more than an order of magnitude) the population of the lower sublevel 6{sup 2}S{sub 1/2}F{sub g} = 3 M = 0 of the “clock” microwave transition F{sub g} = 3 M = 0 ↔ F{sub f} = 4 M = 0 in the cesium frequency standard, which increases the signal intensity in the recording system by the same proportion.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Laser-pumped paraffin-coated cell rubidium frequency standard

We have realized and studied a rubidium atomic frequency standard based on a paraffin-coated cell, exhibiting a short-term frequency stability <3 Multiplication-Sign 10{sup -12} {tau}{sup -1/2} between {tau} = 1 and 100 s. Characterization of the wall-coating is performed by measuring the T{sub 1} and T{sub 2} relaxation times. Perturbations of the medium- to long-term clock stability, due to variations in the laser-intensity, laser frequency, the microwave power shift, and the shifts due to temperature variations are measured and analyzed. A method for reducing the intensity light-shift by detuning the laser frequency and the resulting improvement in clock stability is demonstrated. This work is of relevance for further improvements on Rb cell standards using anti-relaxation wall-coating technology.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Long-term stabilization of intensity-difference squeezing from four-wave mixing in rubidium vapor

Generation of quantum states of light through off-resonance four-wave mixing in rubidium vapor is a straightforward and well-established technique. However, achieving a sufficiently high and consistent level of intensity difference squeezing (IDS) and intrinsic quantum correlations between photon pairs over an extended timescale, necessary for quantum-light-based nonlinear optical spectroscopy and microscopy, remains challenging and largely unexplored. Here, we report a simple stabilization method combining an active periodic laser frequency retuning with an automatic control algorithm based on quantitatively assessing the factors affecting the IDS level and squeezed light intensity. Validation of our method was performed by acquiring data over a 5-hour period, and the results demonstrate a remarkably stable squeezing level of -7.8 dB in combination with a > 4× reduction of the standard deviation of IDS level from 0.46 dB to 0.10 dB. The achieved stabilization further enables us to quantitatively assess the IDS reduction due to the scattering in a polystyrene bead suspension as a function of sample transmission. Our approach should enable a variety of applications requiring an extended squeezing stability over multiple hours, especially for those following biological processes and chemical reactions in real time.

Allen, Christian Harry [Oak Ridge National Laborat↗

Spectroscopy of intercombination transition {sup 1}S{sub 0} – {sup 3}P{sub 1} for secondary cooling of strontium atoms

In the framework of the project aimed at creating an optical standard on cold Sr atoms we have realised sub-Doppler spectroscopy of the intercombination transition {sup 1}S{sub 0} – {sup 3}P{sub 1} (689 nm) in a cell with Sr vapour and in a cloud of atoms loaded in a magneto- optical trap (MOT). By measuring Zeeman splitting of the {sup 3}P{sub 1} level in the magnetic field of the MOT we have succeeded in fine adjustment of the MOT relative to a minimum of the magnetic field, which is necessary for successful secondary-stage cooling on the intercombination transition. In turn, absorption saturation spectroscopy in the vapour cell provides the long-term frequency stability of the second-stage cooling laser at λ = 689 nm. (laser spectroscopy)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Narrow-linewidth laser cooling for rapid production of low-temperature atoms for high data-rate quantum sensing

We present a proof-of-concept demonstration of a narrow linewidth $^{87}$Rb magneto-optical trap (MOT) operating on the narrow linewidth $5S_{1/2}$ → $6P_{3/2}$ transition at 420 nm. We stabilized the absolute frequency of the 420 nm laser to an atomic transition in $^{87}$Rb and demonstrate a MOT using 420 nm light driving the $5S_{1/2}$, $F = 2$ → $6P_{3/2}, F' = 3$ transition. We then use tome-of-flight measurements to characterize the 420 nm MOT temperature, observing a minimum temperature of about $T^{(420)}_{horizontal}$ = 150μK and $T^{(420)}_{vertical}$ = 250μK before the opportunity to perform significant characterization and optimization. Although this temperature is significantly higher then the expected 420 nm Doppler cooling limit ($T_D^{(420)}$ ≈ 34 μK), these are already approaching the Doppler limit of a standard 780 nm MOT ($T_D^{(780)}$ ≈ 146 μK). We believe that with further optimization the Doppler cooling limit of ≈ 34 μK can be achieved. This initial result answers our key research question and demonstrates the viability of applying narrow linewidth laser cooling as a robust technique for future fieldable quantum sensors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-bandwidth image-based predictive laser stabilization via optimized Fourier filters

Controlling the delivery of kHz-class pulsed lasers is of interest in a variety of industrial and scientific applications, from next-generation laser-plasma acceleration to laser-based x-ray emission and high-precision manufacturing. The transverse position of the laser pulse train on the application target is often subject to fluctuations by external drivers (e.g., room cooling and heating systems, motorized optics stages and mounts, vacuum systems, chillers, and/or ground vibrations). For typical situations where the disturbance spectrum exhibits discrete peaks on top of a broad-bandwidth lower-frequency background, traditional PID (proportional-integral-derivative) controllers may struggle, since as a general rule PID controllers can be used to suppress vibrations up to only about 5%–10% of the sampling frequency. Here, a predictive feed-forward algorithm is presented that significantly enhances the stabilization bandwidth in such laser systems (up to the Nyquist limit at half the sampling frequency) by online identification and filtering of one or a few discrete frequencies using optimized Fourier filters. Furthermore, the system architecture demonstrated here uses off-the-shelf CMOS cameras and piezo-electric actuated mirrors connected to a standard PC to process the alignment images and implement the algorithm. To avoid high-end, high-cost components, a machine-learning-based model of the piezo mirror’s dynamics was integrated into the system, which enables high-precision positioning by compensating for hysteresis and other hardware-induced effects. A successful demonstration of the method was performed on a 1 kHz laser pulse train, where externally-induced vibrations of up to 400 Hz were attenuated by a factor of five, far exceeding what could be done with a standard PID scheme.

Natal, Joseph↗

X-Ray Comb Generation from Nuclear-Resonance-Stabilized X-Ray Free-Electron Laser Oscillator for Fundamental Physics and Precision Metrology

An x-ray free-electron laser oscillator (XFELO) is a next-generation x-ray source, similar to free-electron laser oscillators at VUV and longer wavelengths but using crystals as high-reflectivity x-ray mirrors. Each output pulse from an XFELO is fully coherent with high spectral purity. The temporal coherence length can further be increased drastically, from picoseconds to microseconds or even longer, by phase-locking successive XFELO output pulses, using the narrow nuclear resonance lines of nuclei such as Fe-57 as a reference. We show that the phase fluctuation due to the seismic activities is controllable and that due to spontaneous emission is small. The fluctuation of electron-bunch spacing contributes mainly to the envelope fluctuation but not to the phase fluctuation. By counting the number of standing-wave maxima formed by the output of the nuclear-resonance-stabilized (NRS) XFELO over an optically known length, the wavelength of the nuclear resonance can be accurately measured, possibly leading to a new length or frequency standard at x-ray wavelengths. A NRS-XFELO will be an ideal source for experimental x-ray quantum optics as well as other fundamental physics. The technique can be refined for other, narrower resonances such as Ta-181 or Sc-45.

Adams, B. W.↗

Compact, single mode, frequency stabilized laser spectroscopy sources for isotope analysis

We will discuss here ultra-stable narrow line-width Hybrid External Cavity Lasers (HECL) of visible spectrum. The customer requires ~ 2 MHz linewidth / stability (2.7 fm). It is our goal to design the most stable possible ECL, and then enhance its long-term stability by disciplining it to an atomic wavelength reference. Protection against long-term drift can be provided by calibrating HECL wavelength to a hollow-cathode lamp (HCL) standard using the optogalvanic effect to adjust the HECL set-point. Here we report the short-term stability of the HECL alone, i.e., without the discipline of an atomic wavelength reference. For this purpose, we have studied HECLs operating at 405 nm and at 638 nm. We will interpret their performance in terms of the customer’s need for 600 – 700 nm narrow-linewidth spectroscopy. We selected to perform the portion of the work at 405 nm since the sensitivity to cavity stability is ~2x compared with operating in the 600 – 700 nm wavelength range. Further, we will show excellent wavelength stability over time at 638 nm. The two main ECL components are the semiconductor laser chip, including a high reflectivity (HR) mirror, and a volume Bragg grating (VBG) that provides output coupling. Between them is collimating optics. The theoretical analysis and experimental data suggest that control of ECL wavelength in the femtometer wavelength range can be achieved over short-term time scales by carefully controlling both the temperature and very high current stability. From the results presented here temperature control of the laser to 0.001° C along with current stability of 0.001 mA will be needed in a sensor instrument. Finally, we show a path to achieve 2 MHz short-term stability at 600 to 700 nm.

07 ISOTOPE AND RADIATION SOURCES↗