Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical label switching”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Quantum Wrapper Networking for Entanglement Management and Control in Transparent Optical Quantum Networks

The overarching goal of this three-year project was to design and experimentally demonstrate a quantum wrapper networking (QWN) protocol and architecture for entanglement management and control in coexisted classical-quantum networks, facilitating a global quantum Internet. In QWN, the quantum payload (qubits) is wrapped with classical bits as a header. The classical bits facilitate end-to-end transport of the quantum payload without having to read or alter the quantum data payload at intermediate switches and routers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SD-WAN Evaluation Criteria for a Defense Information Systems Network Expeditionary Customer Edge

The Defense Information Systems Agency (DISA) has identified a service provision gap midway between the capacity and capability of a Defense Information Systems Network (DISN) transport Edge Points of Presence (POP) and U.S. Department of Defense (DoD) Enterprise Classified Travel Kit (DECTK). Some deployed force 100-user Tactical Operations Centers are in field locations far removed from the DISN transport core, in challenging environmental conditions with limitations on space, weight, power, and cooling for network equipment. As part of a multi-phase project, Pacific Northwest National Laboratory (PNNL) will gather and analyze requirements, design, develop, prototype, and test a miniaturized and ruggedized DISN Customer Edge POP scaled to support approximately 100 users in a field Tactical Operations Center. An Expeditionary Customer Edge (ECE) will be more suitable for field deployment than a DISN transport Edge POP, using ruggedized hardware and network function virtualization (NFV) to operate in challenging field environmental conditions, plus reduce weight, power, and cooling requirements. A key enabling technology for ECE is Software Defined Wide Area Networking (SD-WAN). This document provides: • A brief overview of SD-WAN use cases and how they apply to ECE • How SD-WAN technology compares to existing networks like DISN that use Optical Transport Networking (OTN) and Multiprotocol Label Switching (MPLS) • SD-WAN functional requirements relevant to ECE • A description of an ECE Virtual Prototype, including simulated wide area network paths and a DISN-representative implementation of MPLS, in Cisco Modeling Labs • Detailed network flow walkthroughs • Evaluation criteria based on ECE-relevant SD-WAN functional requirements Finally, an appendix provides an informal evaluation of Speedify—a commercial retail Virtual Private Network service—against the ECE SD-WAN evaluation criteria.

42 ENGINEERING↗

Rational Control of Off‐State Heterogeneity in a Photoswitchable Fluorescent Protein Provides Switching Contrast Enhancement**

Abstract Reversibly photoswitchable fluorescent proteins are essential markers for advanced biological imaging, and optimization of their photophysical properties underlies improved performance and novel applications. Here we establish a link between photoswitching contrast, one of the key parameters that dictate the achievable resolution in nanoscopy applications, and chromophore conformation in the non‐fluorescent state of rsEGFP2, a widely employed label in REversible Saturable OpticaL Fluorescence Transitions (RESOLFT) microscopy. Upon illumination, the cis chromophore of rsEGFP2 isomerizes to two distinct off ‐state conformations, trans1 and trans2 , located on either side of the V151 side chain. Reducing or enlarging the side chain at this position (V151A and V151L variants) leads to single off ‐state conformations that exhibit higher and lower switching contrast, respectively, compared to the rsEGFP2 parent. The combination of structural information obtained by serial femtosecond crystallography with high‐level quantum chemical calculations and with spectroscopic and photophysical data determined in vitro suggests that the changes in switching contrast arise from blue‐ and red‐shifts of the absorption bands associated to trans1 and trans2 , respectively. Thus, due to elimination of trans2 , the V151A variants of rsEGFP2 and its superfolding variant rsFolder2 display a more than two‐fold higher switching contrast than their respective parent proteins, both in vitro and in E. coli cells. The application of the rsFolder2‐V151A variant is demonstrated in RESOLFT nanoscopy. Our study rationalizes the connection between structural and photophysical chromophore properties and suggests a means to rationally improve fluorescent proteins for nanoscopy applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Chiral, Topological, and Knotted Colloids in Liquid Crystals

The geometric shape, symmetry, and topology of colloidal particles often allow for controlling colloidal phase behavior and physical properties of these soft matter systems. In liquid crystalline dispersions, colloidal particles with low symmetry and nontrivial topology of surface confinement are of particular interest, including surfaces shaped as handlebodies, spirals, knots, multi-component links, and so on. These types of colloidal surfaces induce topologically nontrivial three-dimensional director field configurations and topological defects. Director switching by electric fields, laser tweezing of defects, and local photo-thermal melting of the liquid crystal host medium promote transformations among many stable and metastable particle-induced director configurations that can be revealed by means of direct label-free three-dimensional nonlinear optical imaging. The interplay between topologies of colloidal surfaces, director fields, and defects is found to show a number of unexpected features, such as knotting and linking of line defects, often uniquely arising from the nonpolar nature of the nematic director field. This review article highlights fascinating examples of new physical behavior arising from the interplay of nematic molecular order and both chiral symmetry and topology of colloidal inclusions within the nematic host. Furthermore, the article concludes with a brief discussion of how these findings may lay the groundwork for new types of topology-dictated self-assembly in soft condensed matter leading to novel mesostructured composite materials, as well as for experimental insights into the pure-math aspects of low-dimensional topology.

chirality↗

Nephelometer Instrument Handbook

The Integrating Nephelometer (Figure 1) is an instrument that measures aerosol light scattering. It measures aerosol optical scattering properties by detecting (with a wide angular integration – from 7 to 170°) the light scattered by the aerosol and subtracting the light scattered by the carrier gas, the instrument walls and the background noise in the detector (zeroing). Zeroing is typically performed for 5 minutes every day at midnight UTC. The scattered light is split into red (700 nm), green (550 nm), and blue (450 nm) wavelengths and captured by three photomultiplier tubes. The instrument can measure total scatter as well as backscatter only (from 90 to 170°) (Heintzenberg and Charlson 1996; Anderson et al. 1996; Anderson and Ogren 1998; TSI 3563 2015) At ARM (Atmospheric Radiation Measurement), two identical Nephelometers are usually run in series with a sample relative humidity (RH) conditioner between them. This is possible because Nephelometer sampling is non-destructive and the sample can be passed on to another instrument. The sample RH conditioner scans through multiple RH values in cycles, treating the sample. This kind of setup allows to study how aerosol particles’ light scattering properties are affected by humidification (Anderson et al. 1996). For historical reasons, the two Nephelometers in this setup are labeled “wet” and “dry”, with the “dry” Nephelometer usually being the one before the conditioner and sampling ambient air (the names are switched for the MAOS measurement site due to the high RH of the ambient air).

47 OTHER INSTRUMENTATION↗