Search NASASearch

SEARCH · Search NASA

Results for “optical mounts”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Adjustable Optical Mount Is More Rigid

Improved mount for lens or mirror in laser offers rigidity similar to that of nonadjustable optical mount. In comparison with older adjustable optical mounts, this one less susceptible to movements and distortions caused by vibrations and by thermal expansions and contractions. Mount contains neither adjustment rods (which grow or shrink as temperature varies) nor springs (which transmit vibrations to mounted optic).

Asbury, Bill G.

Optical Mounts for Cryogenic Beam Splitters

Spring-loaded optical mounts maintain flatness and alinement of rigid, framed, or pellicle beam splitters over wide temperature range, despite differences in thermal expansion amoung materials. Mounts permit optical adjustments at ambient temperature even though optical system operated subsequently within few degrees of absolute zero. Mounts useful as holders for integrated-circuit master patterns, survey targets, vibrating membranes, noise- or pressure-sensing membranes, osmosis filters, and fuel-cell elements.

Rudman, A. A.

Space Shuttle Main Engine nozzle mounted optic for throat plane spectroscopy

A program intended to develop a flight-capable nozzle mounted optic for monitoring emissions from metals entrained in the Space Shuttle Main Engine (SSME) flowfield is described. The optic will collect light emitted from metal atoms within the high-temperature, high-pressure SSME chamber and transfer the optical signal to a high-resolution spectrometer via a fiber-optic cable. The nozzle mounted optic makes it possible to conduct earth-to-orbit monitoring of flowfield emissions without requiring modifications to the SSME.

Bickford, R. L.

Sensitivity evaluation of mounting optics using elastomer and bipod flexures

A sensitivity evaluation of mounting 100mm optics using elastomer or bipod flexures was completed to determine the relative effects of geometry, structure, material, thermal and vibration environment as they relate to optical distortion. This paper covers both opto-mechanical designs, as well as analytical results from computer modeling and brassboard tests.

elasomer

Psychophysical Research in Development of a Fiber-optic Helmet Mounted Display

The Fiber Optic Helmet Mounted Display (FOHMD) was conceived as an innovative solution to existing flight simulator display deficiencies. An initial (breadboard) version of the system was fabricated to permit experimentation which would help define design requirements for a more refined engineering prototype. A series of visual/human factors studies are being conducted at the USAF Human Resources Laboratory (AFHRL) Operations Training Division, Williams AFB, Arizona to determine the optimum fit of human observer operating characteristics and fiber optic helmet mounted display technology. Pilot performance within a variety of high resolution insert/binocular overlap combinations is being assessed in two classes of environment. The first two of four studies planned incorporate an air-to-air combat environment, whereas the second two studies will use a low level environment with air to ground weapons delivery.

Kruk, R. V.

The Mount Wilson optical interferometer: The first automated instrument and the prospects for lunar interferometry

Before contemplating an optical interferometer on the Moon one must first review the accomplishments achieved by this technology in scientific applications for astronomy. This will be done by presenting the technical status of optical interferometry as achieved by the Mount Wilson Optical Interferometer. The further developments needed for a future lunar-based interferometer are discussed.

Johnston, Ken J.

Metrology Mount and Optics Mandrels

This document is the Final Report for NASA Grant NAG8-1198 from NASA Marshall Space Flight Center (MSFC) to the Smithsonian Astrophysical Observatory (SAO). The Grant is entitled "Metrology Mount and Optics Materials." This final report is required by the terms of the Grant. The period of performance was from September 15, 1995 through January 14, 1999. Total funding received by SAO from MSFC for this effort was, $254,000. Mr. Lester Cohen carried out most of the work at SAO, but received limited support from other engineers, technicians, and designers. Dr. Harvey Tananbaum, the Principal Investigator for the grant provided overall direction and work- assessment. The Grant has had two funding augmentations to its basic amount and has, over time, emphasized three different research areas - each of which has been an extension of earlier research. The research activity was in 2 areas: (1) Expert opto-structural studies related to separation mechanics and effects of electro formed nickel X-ray mirrors. and (2) Design, fabrication and evaluation of a low force metrology and assembly station for light weight full shell electroformed X-ray mirrors.

Tananbaum, H.

Design of a flexure mount for optics in dynamic and cryogenic environments

The design of a flexure mount for a mirror operating in a cryogenic environment is presented. This structure represents a design effort recently submitted to NASA Ames for the support of the primary mirror of the Space Infrared Telescope Facility (SIRTF). The support structure must passively accommodate the differential thermal contraction between the glass mirror and the aluminium structure of the telescope during cryogenic cooldown. Further, it must support the one meter diameter, 116 kilogram (258 pound) primary mirror during a severe launch to orbit without exceeding the micro-yield of the material anywhere in the flexure mount. Procedures used to establish the maximum allowable radial stiffness of the flexural mount, based on the finite element program NASTRAN and the optical program FRINGE, are discussed. Early design concepts were evaluated using a parametric design program, and the development of that program is presented. Dynamic loading analyses performed with NASTRAN are discussed. Methods of combining modal responses resulting from a displacement response spectrum analysis are discussed, and a combination scheme called MRSS, modified root of sum of squares, is presented. Model combination schemes using MRSS, SRSS, and ABS are compared to the results of the modal frequency response analysis performed with NASTRAN.

Pollard, Lloyd Wayne

Passive Measurement of CO2 Column from an Airborne Platform

We are in the third and final year of our IIP funding to develop a sensor for very precise determination of the CO2 Column. Global measurements of this sort from a satellite platform are needed to improve our understanding of the global carbon budget. In previous reports to this meeting we have described the method by which this system operates and presented data taken during ground based tests of the instrument. Work in the final year has concentrated on building the flight hardened version of the instrument that will be used in our field trials on the Dryden DC-8. The flight unit represents an integration of three channels into a single instrument. These three channels are the CO2 channel, the oxygen pressure sensing channel, and the oxygen temperature sensing channel. Integration of the three channels into a single unit significantly decreases the size of the instrument. The flight unit also employs more rugged optical mounts and integrated optical shielding. Light enters the instrument from below first striking the right angled mirror shown extending over the edge of the platform. The light is then focused through a pinhole to define the instrument field of view, chopped and recollimated. Dichroic mirrors are used to separate the CO2 wavelength from the O2 wavelength and that light is further divided by a 50-50 beamsplitter between the 2 oxygen channels - the pressure channel and the temperature channel. The six white boxes contain the detectors for each of the three channels. The detectors on the left in the photo serve the reference channels and the detectors on the right are for the Fabry-Perots. CO2 is measured by the pair of detectors farthest from the viewer. Pressure via O2 is detected by the central pair of detectors. The closest pair is used to determine temperature via O2.

Heaps, William S.

Optical tracking mount Patent

Tracking mount for laser telescope employed in tracking large rockets and space vehicles to give information regarding azimuth and elevation

Beehm, J. M.

High Resolution X-Ray Explorer (HIREX)

SAO is involved in a study to determine the feasibility of building an orbiting telescope capable of resolving 7 km structure on the Sun. In order to achieve the required imaging the telescope must have a resolution 0.01 arcsec. This fact challenges the state of the art of orbiting telescopes in several areas: Mirror Figuring; Optical Metrology; Optical Mounting; Mirror Figure Control; System Alignment; Optical Stability; Observatory Pointing; and Image Stability. The telescope design concept is based on a 0.6 m Gregorian-style telescope with a 240 meter effective focal length. This is achieved with 2 mirrors supported at opposite ends of a 35 m space-deployable boom. The telescope mirrors are coated with multilayers designed to reflect a broad XUV passband. A third, small mirror, near the focal plane performs the function of selecting the narrow band that is finally imaged. Image stabilization to the 0.005 arcsec level is achieved by active control of the secondary mirror. The primary mirror is held unadjustably to the spacecraft, its pointing set by the spacecraft orientation. The secondary mirror is mounted on a 6-axis stage that permits its position to be changed to align the telescope in space. The stage is intended for intermittent adjustment, both because of its speed of travel, and the TBD alignment procedure. The third mirror is called the TXI (Tuneable X-ray Imager). It is mounted on a gimbal that permits it to be tipped over a 60 degree range, selecting between the individual wavelengths in the initial bandpass. It can also rotated completely out of the way to allow the full, broadband EUV flux to strike the focal plane. Finally, the focal plane assembly is designed to rotate on the outer edge of a circle centered on the TXI mirror rotation axis. This permits the focal plane to move to the location that the TXI redirects the light once it has been set to a given wavelength response. The Engineering Study is divided into the following areas: Mirror Fabrication and Metrology; Optical Layout-Trade Study between On-axis and Off-axis; Overall System Design; and Pointing Control/Image Stabilization. The observational goals of the mission are described in the Mission Requirements document. The work is being performed to the requirements called out in the Science Requirements document.

Goulb, Leon

High Resolution X-Ray Explorer (HIREX)

SAO has carried out a study to determine the feasibility of building an orbiting telescope capable of resolving 7 km structure on the Sun. In order to achieve the required imaging the telescope must have a resolution 0.01 arcsec. This fact challenges the state of the art of orbiting telescopes in several areas: mirror figuring; optical metrology; optical mounting; mirror figure control; system alignment; optical stability; observatory pointing; and image stability image stability. The telescope design concept is based on a 0.6m Cassegrain-style telescope with a 240 meter effective focal length. This is achieved with 2 mirrors supported at opposite ends of a 27 m space-deployable boom. The telescope mirrors are coated with multilayers designed to reflect a broad XUV passband. A third, small mirror, near the focal plane performs the function of selecting the narrow band that is finally imaged. Image stabilization to the 0.005 a,rcsec level is achieved by active control of the secondary mirror. The primary mirror is held unadjustably to the spacecraft, its pointing set by the space- craft orientation. The secondary mirror is mounted on a 6-axis stage that permits its position to be changed to align the telescope in space. The stage is intended for intermittent adjustment, both because of its speed of travel, and the TBD alignment procedure. The third mirror is called the TXI (Tuneable X-ray Imager). It is mounted on a gimbal that permits it to be tipped over a 60 degree range, selecting between the individual wavelengths in the initial bandpass. It can also rotated completely out of the way to allow the full, broadband EUV flux to strike the focal plane.

Golub, Leon

Indexing Mount For Rotation Of Optical Component

Indexing mount for polarizer, wave plate, birefringent plate, or other optical component facilitates rotation of component to one or more preset angles. Includes hexagonal nut holding polarizer or other optical component. Ball bearing loaded by screw engages notch on cylindrical extension of nut engaging bracket. Time-consuming and tedious angular adjustment unnecessary: component turned quickly and easily, by hand or by use of wrench, to preset angular positions maintained by simple ball-detent mechanism.

Reichle, Donald J., Jr.

Fiber Optic Sensors for Health Monitoring of Morphing Aircraft

Fiber optic sensors are being developed for health monitoring of future aircraft. Aircraft health monitoring involves the use of strain, temperature, vibration and chemical sensors. These sensors will measure load and vibration signatures that will be used to infer structural integrity. Sine the aircraft morphing program assumes that future aircraft will be aerodynamically reconfigurable there is also a requirement for pressure, flow and shape sensors. In some cases a single fiber may be used for measuring several different parameters. The objective of the current program is to develop techniques for using optical fibers to monitor composite cure in real time during manufacture and to monitor in-service structural integrity of the composite structure. Graphite-epoxy panels were fabricated with integrated optical fibers of various types. The panels were mechanically and thermally tested to evaluate composite strength and sensor durability. Finally the performance of the fiber optic sensors was determined. Experimental results are presented evaluating the performance of embedded and surface mounted optical fibers for measuring strain, temperature and chemical composition. The performance of the fiber optic sensors was determined by direct comparison with results from more conventional instrumentation. The facilities for fabricating optical fiber and associated sensors and methods of demodulating Bragg gratings for strain measurement will be described.

Brown, Timothy

Silicon Carbide Mounts for Fabry-Perot Interferometers

Etalon mounts for tunable Fabry- Perot interferometers can now be fabricated from reaction-bonded silicon carbide structural components. These mounts are rigid, lightweight, and thermally stable. The fabrication of these mounts involves the exploitation of post-casting capabilities that (1) enable creation of monolithic structures having reduced (in comparison with prior such structures) degrees of material inhomogeneity and (2) reduce the need for fastening hardware and accommodations. Such silicon carbide mounts could be used to make lightweight Fabry-Perot interferometers or could be modified for use as general lightweight optical mounts. Heretofore, tunable Fabry-Perot interferometer structures, including mounting hardware, have been made from the low-thermal-expansion material Invar (a nickel/iron alloy) in order to obtain the thermal stability required for spectroscopic applications for which such interferometers are typically designed. However, the high mass density of Invar structures is disadvantageous in applications in which there are requirements to minimize mass. Silicon carbide etalon mounts have been incorporated into a tunable Fabry-Perot interferometer of a prior design that originally called for Invar structural components. The strength, thermal stability, and survivability of the interferometer as thus modified are similar to those of the interferometer as originally designed, but the mass of the modified interferometer is significantly less than the mass of the original version.

Lindemann, Scott

Optical devices for proximity operations study and test report

Operational and physical requirements were investigated for a low-light-level viewing device to be used as a window-mounted optical sight for crew use in the pointing, navigating, stationkeeping, and docking of space vehicles to support space station operations and the assembly of large structures in space. A suitable prototype, obtained from a commercial vendor, was subjected to limited tests to determine the potential effectiveness of a proximity optical device in spacecraft operations. The constructional features of the device are discussed as well as concepts for its use. Tests results show that a proximity optical device is capable of performing low-light-level viewing services and will enhance manned spacecraft operations.

Smith, R. A.