Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical profiler”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

X-ray and optical profiler analysis of electroformed X-ray optics

Electroformed grazing incidence mirrors were tested with X-rays and were measured with an optical profiler. Their total effective areas are greater than about 70 percent of the theoretical values both for 1.5- and 6.4-keV X-rays. The half-power diameters are less than about 2 min of arc at 1.5 keV. A design of the mirror array telescope for high energies which has a total effective area of about 1000 sq cm for 7-keV X-rays is presented.

Matsui, Yutaka↗

Optical profile determining apparatus and associated methods including the use of a plurality of wavelengths in the reference beam and a plurality of wavelengths in a reflective transit beam

An optical profile determining apparatus includes an optical detector and an optical source. The optical source generates a transmit beam including a plurality of wavelengths, and generates a reference beam including the plurality of wavelengths. Optical elements direct the transmit beam to a target, direct a resulting reflected transmit beam back from the target to the optical detector, and combine the reference beam with the reflected transmit beam so that a profile of the target is based upon fringe contrast produced by the plurality of wavelengths in the reference beam and the plurality of wavelengths in the reflected transmit beam.

Montgomery, Robert M.↗

Corroborating Channel Gap Probe Measurements with an Optical Profiler

As nuclear fuel plates get irradiated, the fuel plate thickness changes. How the fuel plate changes with irradiation is a significant parameter that is important to predict fuel performance in new fuel systems. The channel gap probe is used to indirectly infer changes in fuel plate thicknesses by measuring the gaps between the fuel plates contained within capsules after each irradiation cycle. Independent measures should be used to corroborate salient measurements such as changes in fuel thickness which help ascertain fuel performance. The use of traditional metrological tools to validate channel gap probe measurements are not practical due to the capsule geometry. The accuracy of the channel gap probe inserted within a capsule has not been verified. Since there is no “gold” standard measurement to verify CGP measurements, an optical profilometer has been used to corroborate the CGP measurements. The optical profilometer has been able to corroborate the capsules channel gaps to within 0.04 mm for both ends of the capsule. The optical profiler is also able to measure plate thickness that matched micrometer measurements to within 0.025 mm. In conclusion, the profilometer corroborated the CGP measurements but a discrepancy was found at one end of the capsule for the Inside Capsule Width from the profilometer when compared to a caliper measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bio-optical profile data report coastal transition zone program, R/V Thomas Washington, June 24 - July 21, 1988

Twenty-three vertical profiles of the bio-optical properties of the ocean were made during a research cruise on the R/V Thomas Washington, June 24 to July 21, 1988, as part of the Coastal Transition Zone Program off Point Arena, California. A summary is given, to provide investigators with an overview of the data collected. The entire data set is available in digital form for interested researchers.

Davis, Curtiss O.↗

Bio-optical profile data report coastal transition zone program, R/V Point Sur, June 15-28, 1987

Twenty vertical profiles of the bio-optical properties of the ocean were made during a research cruise on the R/V Point Sur, June 15 to 28, 1987, as part of the Coastal Transition Zone Program off Point Arena, California. Extracted chlorophyll values were also measured at some stations to provide calibration data for the in situ fluorometer. This summary provides investigators with an overview of the data collected. The entire data set is available in digital form.

Davis, Curtiss O.↗

Bio-optical profile data report: Joint Global Ocean Flux Study, Hawaii Ocean Time-Series, HOT-3, R/V Moana Wave, 6-10 January 1989

Time-series measurements of the incident surface downwelling irradiance and vertical profiles of the Bio-optical properties of the ocean have been measured during the third cruise of the Hawaii Ocean Time-Series to the ALOHA site, 22 degrees 56.4 minutes N, 157 degrees 54.6 minutes W, north of the island of Oahu, Hawaii, during the period January 6 to 10, 1989. A summary of these data is presented to permit investigators an overview of the data collected. The data are available in digital form for scientific investigators.

Collins, Donald J.↗

Bio-optical profile data report: Southern California Bight Study (SCB2-29) R/V Robert G. Sproul, 20-25 August 1988

Time series measurements of the incident surface downwelling irradiance and vertical profiles of the bio-optical properties of the ocean were studied during the 29th cruise of the Southern California Bight Study (SCBS) during the period of August 20-25, 1988. A summary of these data is presented to permit investigators an overview of the data collected. The data are available in digital form for scientific investigators.

Collins, Donald J.↗

Investigation of the feasibility of temperature profiling optical diagnostics in the SSME fuel pre-burner

Results of an analytical investigation to determine the feasibility of temperature profiling in the space shuttle main engine (SSME) fuel preburner are presented. In this application it is desirable to measure temperature in the preburner combustor with a remote, nonintrusive optical technique. Several techniques using laser excitation were examined with a consideration of the constraints imposed by optical access in the fuel preburner and the problems associated with operation near the functioning space shuttle engine. The potential performance of practical diagnostic systems based on spontaneous Raman backscattering, laser induced fluorescence, and coherent anti-Stokes Raman spectroscopy were compared analytically. A system using collection of spontaneous Raman backscattering excited by a remotely located 5 to 10 watt laser propagated to the SSME through a small diameter optical fiber was selected as the best approach. Difficulties normally associated with Raman scattering: weak signal strength and interference due to background radiation are not expected to be problematic due to the very high density in this application, and the low flame luminosity expected in the fuel rich hydrogen oxygen flame.

Shirley, J. A.↗

Binary pseudo-random array standards for calibration of 3D optical surface profilers used for metrology with aspheric x-ray optics

High-accuracy surface metrology is vitally important in manufacturing ultra-high-quality free-form mirrors designed to manipulate x-ray light with nanometer-scale wavelengths. The current and potential capabilities of x˗ray mirror manufacturing are limited by inherent imperfections of the integrated metrology tools. Metrology tools are currently calibrated with super-polished flat test-standard/reference mirrors. This is acceptable for fabrication of slightly curved x-ray optics. However, for even moderately curved aspherical x-ray mirrors the flat-reference calibration is not sufficiently accurate. For micro-stitching interferometry developed for surface measurements with curved x-ray mirrors, the tool aberration errors are known to be transferred into the optical surface topography of x-ray mirrors. Our approach to improving metrology is to thoroughly calibrate the measuring tool and apply the results of the calibration to deconvolution of the measured data. Here we explore the application of a recently developed technique for calibrating the instrument transfer function (ITF) of 3D optical surface profilers to metrology with significantly curved x-ray optics. The technique, based on test standards patterned with two-dimensional (2D) binary pseudo-random arrays (BPRAs), employs the unique properties of the BPRA patterns in the spatial frequency domain. The inherent 2D power spectral density of the pattern has a deterministic white-noise-like character that allows direct determination of the ITF with uniform sensitivity over the entire spatial frequency range and field of view of an instrument. The high efficacy of the technique has been previously demonstrated in application to metrology with flat and slightly curved optics. Here, we concentrate on development of an efficient fabrication process for production of highly randomized (HR) BPRA test standards on flat and 500-mm spherical optical substrates. We also compare and discuss the results of the ITF calibration of an interferometric microscope when using the HR BPRA standards on flat and curved substrates.

Munechika, Keiko↗

Binary pseudo-random array standards for calibration of 3D optical surface profilers used for metrology with significantly curved x-ray optics

High-accuracy metrology is vitally important in manufacturing ultra-high-quality free-form mirrors designed to manipulate X-ray light with nanometer-scale wavelengths. The current capabilities and possibility for improvements in X-ray mirror manufacturing are limited by inherent imperfections of the integrated metrology tools. In the case of Fizeau interferometry, metrology tools are currently calibrated with super-polished flat test-standard/reference mirrors. This is acceptable for measuring slightly curved X-ray optics. However, for even moderately curved aspherical X-ray mirrors the flat-reference calibration is not sufficiently accurate and stitching Fizeau interferometer-based surface metrology is used to mitigate the problem. But still, the retrace and aberration errors, as well as the limited spatial resolution, described with the instrument transfer function (ITF), can be transferred into the optical surface topography of X-ray mirrors obtained in stitching metrology. For ITF calibration, we have developed an original technique, based on test standards structured as two-dimensional (2D) highly-randomized (HR) binary pseudo-random arrays (BPRAs). The technique employs the unique properties of the HR BPRA patterns in the spatial frequency domain., i.e. the inherent 2D power spectral density of the HR BPRA pattern has a deterministic white-noise-like character that allows direct determination of the ITF with uniform sensitivity over the entire spatial frequency range and field-of-view of an instrument. Here, we explore technological, metrological, and analytical aspects essential for calibration of the retrace and aberration errors of Fizeau interferometers using different types of tilted test samples, including a super-polished reference mirror for the re-trace calibration and the uniformly redundant array (URA) BPRA standards for the geometrical distortion (aberration) calibration. While the first method was previously demonstrated by researchers at DIAMOND Light Source, a method based on the URA BPRA is described and demonstrated here for the first time. We outline the design and fabrication process used in fabrication of URA BPRA test standards, and present the results of application of the URA BPRA standards demonstrating the high efficacy of our approach to geometrical distortion calibration of Fizeau interferometers. We also discuss the possible sources of unexpected peculiarities of the systematic errors, including an astigmatic character of the retrace error, observed with Fizeau interferometers at the Advanced Light Source X-Ray Optics Laboratory.

Munechika, Keiko↗

The analysis of apparent optical depth profiles for interstellar absorption lines

Attention is given to the apparent optical depth method, a procedure for analyzing interstellar absorption lines. Observed absorption-line profiles are converted into profiles of apparent optical depth, and apparent column density per unit velocity. By comparing the latter for a given interstellar species having two or more absorption lines which differ in the product, the presence or absence of unresolved saturated structure in the profiles can be directly inferred. The method is illustrated using absorption-line data from the IUE satellite for the highly ionized gas toward HD 64760. Additional illustrations and a study of the method's accuracy are provided through a series of numerical simulations of multicomponent interstellar absorption situations. The method is compared to the standard growth curve method for deriving interstellar column densities. The principal value of the apparent optical depth method is that the absorption-line data are directly converted into a form that provides for direct scientific interpretations of the physical conditions in the interstellar absorbing medium as a function of velocity.

Savage, Blair D.↗

Measured and calculated optical property profiles in the mixed layer and free troposphere

Nearly simultaneous measurements of the physical and optical properties of mixed layer and free tropospheric aerosols near Boulder, Colorado, were made on several occasions using aircraft, balloon, and ground-based sensors. This effort (Front Range Lidar, Aircraft, and Balloon experiment (FRLAB)) was conducted with the purpose of obtaining a diverse, self-consistent data set that could be used for testing optical model calculations based on measured physical characteristics such as apparent size distribution, composition, and shape. It was found that even with the uncertainties involved, the model predictions are in good agreement with the measurements in the visible and near infrared wavelength regions. At CO2 lidar wavelengths there is considerably more uncertainty in both the calculated and measured values; however, within the estimated errors there appears to be satisfactory agreement except for the highest free tropospheric layer studied. The results also indicate that during FRLAB the aerosol in the boundary layer and free troposphere behaved as spherical particles for optical modeling purposes. The utility of the observations for determining the extinction-to-backscatter ratio relevant to aerosols in the boundary layer and free troposphere is described with typical measured values being in the 20 to 30 sr range.

Rosen, James M.↗

Surface characterization and testing II; Proceedings of the Meeting, San Diego, CA, Aug. 10, 11, 1989

Various papers on surface characterization and testing are presented. Individual topics addressed include: simple Hartmann test data interpretation, optimum configuration of the Offner null corrector, system for phase-shifting interferometry in the presence of vibration, fringe variation and visibility in speckle-shearing interferometry, functional integral representation of rough surfaces, calibration of surface heights in an interferometric optical profiler, image formation in common path differential profilometers, SEM of optical surfaces, measuring surface profiles with scanning tunneling microscopes, surface profile measurements of curved parts, high-resolution optical profiler, scanning heterodyne interferometer with immunity from microphonics, real-time crystal axis measurements of semiconductor materials, radial metrology with a panoramic annular lens, surface analysis for the characterization of defects in thin-film processes, Spacelab Optical Viewport glass assembly optical test program for the Starlab mission, scanning differential intensity and phase system for optical metrology.

Greivenkamp, John E.↗

Measurements of Aerosol Vertical Profiles and Optical Properties during INDOEX 1999 Using Micro-Pulse Lidars

Micro-pulse lidar systems (MPL) were used to measure aerosol properties during the Indian Ocean Experiment (INDOEX) 1999 field phase. Measurements were made from two platforms: the NOAA ship RN Ronald H. Brown, and the Kaashidhoo Climate Observatory (KCO) in the Maldives. Sunphotometers were used to provide aerosol optical depths (AOD) needed to calibrate the MPL. This study focuses on the height distribution and optical properties (at 523 nm) of aerosols observed during the campaign. The height of the highest aerosols (top height) was calculated and found to be below 4 km for most of the cruise. The marine boundary layer (MBL) top was calculated and found to be less than 1 km. MPL results were combined with air mass trajectories, radiosonde profiles of temperature and humidity, and aerosol concentration and optical measurements. Humidity varied from approximately 80% near the surface to 50% near the top height during the entire cruise. The average value and standard deviation of aerosol optical parameters were determined for characteristic air mass regimes. Marine aerosols in the absence of any continental influence were found to have an AOD of 0.05 +/- 0.03, an extinction-to-backscatter ratio (S-ratio) of 33 +/- 6 sr, and peak extinction values around 0.05/km (near the MBL top). The marine results are shown to be in agreement with previously measured and expected values. Polluted marine areas over the Indian Ocean, influenced by continental aerosols, had AOD values in excess of 0.2, S-ratios well above 40 sr, and peak extinction values approximately 0.20/km (near the MBL top). The polluted marine results are shown to be similar to previously published values for continental aerosols. Comparisons between MPL derived extinction near the ship (75 m) and extinction calculated at ship-level using scattering measured by a nephelometer and absorption using a PSAP were conducted. The comparisons indicated that the MPL algorithm (using a constant S-ratio throughout the lower troposphere) calculates extinction near the surface in agreement with the ship-level measurements only when the MBL aerosols are well mixed with aerosols above. Finally, a review of the MPL extinction profiles showed that the model of aerosol vertical extinction developed during an earlier INDOEX field campaign (at the Maldives) did not correctly describe the true vertical distribution over the greater Indian Ocean region. Using the average extinction profile and AOD obtained during marine conditions, a new model of aerosol vertical extinction was determined for marine atmospheres over the Indian Ocean. A new model of aerosol vertical extinction for polluted marine atmospheres was also developed using the average extinction profile and AOD obtained during marine conditions influenced by continental aerosols.

Welton, Ellsworth J.↗

Theory of direct scattering of neutral and charged atoms

The theory for direct elastic and inelastic collisions between composite atomic systems formulated within the framework of the Glauber approximation is presented. It is shown that the phase-shift function is the sum of a point Coulomb contribution and of an expression in terms of the known electron-hydrogen-atom and proton-hydrogen-atom phase shift function. The scattering amplitude is reexpressed, the pure Coulomb scattering in the case of elastic collisions between ions is isolated, and the exact optical profile function is approximated by a first-order expansion in Glauber theory which takes into account some multiple collisions. The approximate optical profile function terms corresponding to interactions involving one and two electrons are obtained in forms of Meijer G functions and as a one-dimensional integral, and for collisions involving one or two neutral atoms, the scattering amplitude is further reduced to a simple closed-form expression.

Franco, V.↗

A l% and 1cm Perspective Leads to a Novel CDOM Absorption Algorithm

A next-generation in-water profiler designed to measure the apparent optical properties of seawater was developed and validated across a wide dynamic range of water properties. This new Compact-Optical Profiling System (C-OPS) design uses a novel, kite-shaped, free-falling backplane with adjustable buoyancy and is based on 19 state-of-the-art microradiometers, spanning 320-780 nm. Data collected as part of the field commissioning were of a previously unachievable quality and showed that systematic uncertainties in the sampling protocols were discernible at the 1% optical and 1cm depth resolution levels. A sensitivity analysis as a function of three water types, established by the peak in the remote sensing reflectance spectra, revealed which water types and spectral domains were the most indicative of data acquisition uncertainties. The unprecedented vertical resolution of C-OPS measurements provided near-surface data products at the spectral endpoints with a quality level that has not been obtainable. The improved data allowed development of an algorithm for predicting the spectral absorption due to chromophoric dissolved organic matter (CDOM) using ratios of diffuse attenuation coefficients with over 99% of the variance in the data explained.

Morrow, J. H.↗

X-ray spectra and large-scale features of two starburst galaxies - NGC 253 and M82

The results of Einstein Observatory IPC X-ray observations of the well-known nearby starburst galaxies NGC 253 and M82 are presented. The major axis X-ray surface brightness profile of NGC 253 is steeper than the optical profile, but follows the radio continuum distribution closely. Extended X-ray emission with no optical or radio counterpart is found on the northern side of this galaxy. It is suggested that this emission may be due to gaseous clouds ejected from the starburst nucleus. The X-ray halo of M82 extends as far as 9 arcmin away from the nucleus along the minor axis. The radial distribution of the X-ray surface brightness of this halo is steep and suggests a density distribution proportional to 1/r-squared, typical of free-flowing winds. The spectral properties of the nuclear regions are different from those of the surrounding emission. They are fitted with large intrinsic absorption columns and possibly lower emission temperatures.

Fabbiano, G.↗