Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical relay”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Design of a free-space image-relay optical time-domain reflectometer to measure fiber-optic time delays at inertial confinement fusion relevant wavelengths

Fiber optics are an integral part of data collection, often used to transport visible and UV light to streaked spectrometers and photodetectors. Precisely measuring fiber-optic time delay (FOTD) is necessary for absolute data timing or fiber replacement. An optical time domain reflectometer (OTDR) can be used to measure the fiber-optic time delay. Commercial OTDR’s measure only the fiber in telecommunications wavelengths in the IR. To measure fibers at relevant wavelengths for inertial confinement fusion experiments, a solution using a free-space image relay was devised at the University of Rochester’s Laboratory for Laser Energetics (LLE), where readily available equipment has been used to measure the FOTD to within 2 ps at 526.5 nm as well as 351 nm, which is an order of magnitude better than the timing jitter between LLE’s Hardware Timing System and second-harmonic (526.5-nm) fiducial laser pulses.

47 OTHER INSTRUMENTATION↗

Optical Relays for Imaging Scintillators

Presentation at the "Multi-Probe Radiography IV: Detectors and Image Analysis" workshop, to be held at LANL, in the Rosen Auditorium. Host is Bob Reinovsky, LANL, 505-699-1127. LANL Point of Contact: Mariana Alvarado Alvarez, LANL, 505-665-7994.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optical Relays for Imaging Scintillators

Cygnus is a dual beam high-energy radiographic x-ray source. Ten years ago, three large zoom lenses were assembled to collect images from 200 mm x 200 mm square scintillators. The zoom capability allows zooming down to a 60 mm x 60 mm picture from the scintillator. Current radiographic imaging needs now require larger 270 mm x 270 mm square scintillators and the capability to use both 92 mm x 92 mm and 62 mm x 62 mm CCD cameras, and a new lens design to meet these needs. This zoom lens incorporates 11 elements and is designed to be telecentric. It images a scintillator emitting light peaking at 435 nm, so special glass types are required for the lens elements. Much larger elliptical pellicles are needed to deflect the scintillator light out of the x-ray path into the lens. The optical axis of the imaging system must be colinear with the x-ray axis. Two scintillators are positioned in each of two Cygnus x-ray axes, for a total of four scintillators and four lens systems. An optional configuration will be shown, enabling two lens systems imaging opposite sides of a single scintillator, for a total of four lenses and two scintillators. Although this configuration has advantages, it suffers from crosstalk. Care must be taken to analyze the anti-reflection coatings applied to all the elements in the imaging chain, including the CCD array and

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Photonic Doppler velocimetry probe used to measure grain boundaries of dynamic shocked materials

Material scientists have developed computational modeling to predict the dynamic response of materials undergoing stress, but there is still a need to make precision measurements of surfaces undergoing shock compression. Miniature photonic Doppler velocimetry (PDV) probes have been developed to measure the velocity distribution from a moving surface traveling tens of kilometers per second. These probes use hundreds of optical fibers imaged by optical relays onto different regions of this moving surface. While previous work examined large surface areas, we have now developed a PDV microscope that can interrogate 37 different spots within a field of view of <1 mm, with a standoff distance of 17 mm, to analyze the motion differences across grain boundaries of the material undergoing dynamic stress. Each PDV fiber interrogates a 10 μm spot size on the moving surface. A separate imaging system using a coherent bundle records the location of the PDV spots relative to the grain boundaries prior to the dynamic event. Designing the mounting structures for the lenses, fibers, and coherent bundle was a challenge. To minimize back reflections, the fibers are index matched onto the first relay lens, which is made of fused silica. The PDV fibers are aligned normal to the moving surface. The imaging probe views the surface at an 18° angle. The coherent bundle is tilted 11° to its optical relay. All components are assembled into a single probe head assembly. The coherent bundle is removed from the probe head to be used for the next dynamic event. Alignment issues will also be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scanning optical microscope with long working distance objective

A scanning optical microscope, including: a light source to generate a beam of probe light; collimation optics to substantially collimate the probe beam; a probe-result beamsplitter; a long working-distance, infinity-corrected objective; scanning means to scan a beam spot of the focused probe beam on or within a sample; relay optics; and a detector. The collimation optics are disposed in the probe beam. The probe-result beamsplitter is arranged in the optical paths of the probe beam and the resultant light from the sample. The beamsplitter reflects the probe beam into the objective and transmits resultant light. The long working-distance, infinity-corrected objective is also arranged in the optical paths of the probe beam and the resultant light. It focuses the reflected probe beam onto the sample, and collects and substantially collimates the resultant light. The relay optics are arranged to relay the transmitted resultant light from the beamsplitter to the detector.

Cloutier, Sylvain G↗

Neutron temporal diagnostic for high-yield deuterium–tritium cryogenic implosions on OMEGA

A next-generation neutron temporal diagnostic (NTD) capable of recording high-quality data for the highest anticipated yield cryogenic deuterium–tritium (DT) implosion experiments was recently installed at the Omega Laser Facility. A high-quality measurement of the neutron production width is required to determine the hot-spot pressure achieved in inertial confinement fusion experiments—a key metric in assessing the quality of these implosions. The design of this NTD is based on a fast-rise-time plastic scintillator, which converts the neutron kinetic energy to 350- to 450-nm-wavelength light. The light from the scintillator inside the nose-cone assembly is relayed ∼16 m to a streak camera in a well-shielded location. An ∼200× reduction in neutron background was observed during the first high-yield DT cryogenic implosions compared to the current NTD installation on OMEGA. An impulse response of ∼40 ± 10 ps was measured in a dedicated experiment using hard x-rays from a planar target irradiated with a 10-ps short pulse from the OMEGA EP laser. The measured instrument response includes contributions from the scintillator rise time, optical relay, and streak camera.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Jefferson Lab High Power Broadband THz Facility

Jefferson Lab operates a broadband terahertz (THz) facility, whose light is generated by 300 fs FWHM 135 pC bunches of electrons at an energy of 125 MeV as they traverse a magnetic compression chicane prior to entering the optical cavity of the Jefferson Lab Free Electron Laser (FEL)[1-3]. The repetition rate of the electron bunches, and hence that of the light pulses, can be as high as 75 MHz continuous. Approximately 1 microJoule of energy is emitted for each pulse, which implies an average power of up to 75W, a peak power of several MW and electric fields of MV/m. Niche applications of this unique source are pump-probe dynamics, both in and out of equilibrium, and large-scale imaging. The beamline itself is designed to deliver an f/8 beam 2mm vertical × 3mm horizontal in size and 60% vertically polarized from a subtended angle of ~200 milliradians horizontal by ~135 milliradians vertical in the accelerator. The first mirror is copper-braid cooled. The philosophy of the optical design is to use a relay optics configuration to transport the beam via reflection off metal mirrors through a series of focal points, with the final one being at a diamond window. The optical scheme was developed using the Synchrotron Radiation Workshop (SRW)[4]. This code performs a full calculation of the electric field from a relativistic electron. It does not handle multiparticle coherent enhancement[5], but it is significantly different from all the other synchrotron radiation calculations because it retains a term called the Coulomb term in which the electric field falls off as 1/R2. In addition to calculating the electric field and the intensity, the code also allows one to propagate the field through the optical focusing elements and apertures. The beam exiting the final diamond window in the THz user lab passes into a series of vacuum chambers with considerable flexibility for attenuation, collimation, and/or beam splitting for imaging, spectroscopy and 2 photon pump-probe measurements. In this talk we will discuss the details of the philosophy, optical design and operating experience of this facility and also present ideas for discussion. We deeply appreciate the excellent support of our colleagues without which these facilities would not have been built and operated. This work was supported by the U.S. Dept. of Energy under contract DE-AC05-06-OR23177, and the Commonwealth of Virginia. The FEL facility is supported by the Office of Naval Research. 1. S. V. Benson et al, ?The VUV/IR/THz Free Electron Laser Program at Jefferson Lab?, Nucl. Instr. and Meth. A649 9 (2011). 2. G.L. Carr, M.C. Martin, W.R. McKinney, K. Jordan, G.R. Neil and G.P. Williams ?High Power Terahertz Radiation from Relativistic Electrons?, Nature 420 153-156 (2002). 3. J.M. Klopf et al. ?The Jefferson Lab high power THz user facility?, Nucl. Instrum. Methods A582, 114-116 (2007). 4. O. Chubar, P. Elleaume, "Accurate And Efficient Computation Of Synchrotron Radiation In The Near Field Region", proc. of the EPAC98 Conference, 22-26 June 1998, p.1177-1179. 5. C. J. Hirschmugl, M. Sagurton and G. P. Williams, ?Multiparticle coherence calculations for synchrotron radiation emission? Physical Review A44, 1316 (1991).

Klopf, John↗

Photonic Doppler Velocimetry Probe Designed with Stereo Imaging

The velocity distribution of an imploding curved surface is measured with a miniature fiber-optic probe. The probe uses fiber matrix arrays that are focused onto different regions of this curved surface. A pyramid reflector deflects the interrogation onto specific regions of this curved surface. The fiber arrays record velocity along several hundred lines of sight with sub-nanosecond resolution. Reflected light from each spot on the moving surface is Doppler shifted with a small portion of this light propagating backwards through the launching fiber. The reflected light is mixed with a reference laser in a technique called Photonic Doppler velocimetry, providing continuous time records. Within the probe, seven groups of miniature optical relay lenses are grouped into a close-packed array, allowing the interrogation of seven regions of interest. A six-faceted pyramid reflector with a conical hole drilled into its center is used to direct the light beams onto different regions. To minimize back reflections, the fiber matrix arrays are index matched onto the first relay lens made of fused silica. The optical lens design minimizes the laser beam diameters and also provides excellent imaging capabilities. Therefore, two of the fiber matrix arrays are replaced by coherent bundles for stereo imaging recorded by a high-speed framing camera. This requires additional cutouts of the pyramid reflector to allow imaging overlap. Six additional 1.5 mm diameter incoherent bundles are attached to the edges of the pyramid reflector and are used for illumination. Precision metrology on the direction cosines of the trajectories is measured to satisfy environmental requirements for vibration and temperature.

photonic doppler velocimetry, PDV, pyramid reflect↗

Laser and optical transport line for laser-based ion beam diagnostics and control in the SNS linear accelerator

We report our recent upgrade of the laser and optical transport line for the laser-based ion beam diagnostics (laser wire) system at the linear accelerator (linac) of the Spallation Neutron Source (SNS). A new light source based on diodepumped solid-state laser amplifiers has been developed to provide near diffraction-limited laser beam with a variety of pulse structures. The free-space optical transport line has been modified to include image relay optics with remote control, which greatly improved the laser beam quality and position stability at individual measurement stations. The upgraded system enables novel beam diagnostics/control capabilities including longitudinal profile measurement and high-energy proton beam extraction from the SNS linac.

Liu, Yun↗

Combining visible shadowgraph imaging with x-ray imaging for dynamic shock experiments

Interrogating ejecta particles launched from target materials that are undergoing dynamic shock can be done with both x-ray imaging and visible shadowgraph imaging. Our dynamic testing must be done inside a containment vessel with limited access ports available. We designed an imaging system to relay both types of imaging systems through a single port using the same optical relay and then splitting the images onto three separate high-speed imaging cameras outside the containment vessel. X-ray imaging provides ejecta density measurements. Shadowgraph imaging that is done at two wavelengths (blue and red) constrains ejecta particle size distributions and provides areal density measurements of the ejecta cloud. The ejecta particles are positioned 225 mm before the x-ray scintillators; this arrangement permits a folded mirror system to allow the shadowgraph data to bypass the x-ray scintillators. This configuration results in spatial separations between the intermediate image planes of the x-ray and shadowgraph images along the optical axis. At the position of the x-ray intermediate image plane, mirrors are positioned such that the shadowgraph images are kicked out and their images are sent on to different cameras. Positioning of the large doublet relay lenses keeps shrapnel from impacting the vessel containment windows.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design, Assembly, and Testing of a Photon Doppler Velocimetry Probe

A novel fiber-optic probe measures the velocity distribution of an imploding surface along many lines of sight. Reflected light from each spot on the moving surface is Doppler shifted with a small portion of this light propagating backwards through the launching fiber. The reflected light is mixed with a reference laser in a technique called photon Doppler velocimetry, providing continuous time records. Within the probe, a matrix array of 56 single-mode fibers sends light through an optical relay consisting of three types of lenses. Seven sets of these relay lenses are grouped into a close-packed array allowing the interrogation of seven regions of interest. A six-faceted prism with a hole drilled into its center directs the light beams to the different regions. Several types of relay lens systems have been evaluated, including doublets and molded aspheric singlets. The optical design minimizes beam diameters and also provides excellent imaging capabilities. One of the fiber matrix arrays can be replaced by an imaging coherent bundle. This close-packed array of seven relay systems provides up to 476 beam trajectories. The pyramid prism has its six facets polished at two different angles that will vary the density of surface point coverage. Fibers in the matrix arrays are angle polished at 8{sup o} to minimize back reflections. This causes the minimum beam waist to vary along different trajectories. Precision metrology on the direction cosine trajectories is measured to satisfy environmental requirements for vibration and temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of the optical design of the ITER MSE diagnostic

The motional Stark effect (MSE) diagnostic will be essential for the study of advanced scenarios on ITER and its design is currently underway with initial emphasis on the optical design. Optical performance, as measured by photon throughput and minimization of polarization aberrations, will be critical to the success of the diagnostic. Consequently, the initial design work has been focused heavily on this area. In order meet the ITER MSE diagnostic design requirements, two approaches for the measurement are under consideration. The first is based on standard polarimeter techniques to measure the polarization of the emitted light, whereas the second measures the Stark splitting from which |B| can be inferred, where |B| is the magnitude of the total magnetic field. The base line design of the optical system is centered on the first approach. Emphasis in this case is placed on minimizing the polarization aberrations of the optical relay system. Motivation for the second method results from concern that the optical properties of the plasma-facing mirror, particularly its diattenuation and retardance, will degrade with plasma exposure. The second approach, while less sensitive to aberrations induced by plasma exposure effects, requires greater optical throughput in order to measure the complete Stark spectrum. We have developed an optimized optical design applicable to both measurement techniques. A summary of the design is presented and design issues are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Progress and Design Status of the ITER MSE Diagnostic

The Motional Stark Effect (MSE) diagnostic will be essential for the study of advanced scenarios on ITER and its design is currently underway. In order meet the ITER MSE diagnostic design requirements, two approaches for the measurement are under consideration. The first is based on standard polarimeter techniques to measure the polarization of the emitted light, whereas the second measures the Stark splitting from which |B| can be inferred, where |B| is the magnitude of the total magnetic field. The baseline design of the optical system is centered on the first approach. Emphasis in this case is placed on minimizing the polarization aberrations of the optical relay system. Motivation for the second method results from concern that the optical properties of the plasma-facing mirror, particularly its diattenuation and retardance, will degrade with plasma exposure. The second approach, while less sensitive to aberrations induced by plasma exposure effects, requires greater optical throughput in order to measure the complete Stark spectrum. We have developed optimized designs for both techniques and will present a comparison of them and discuss the associated design trade-offs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Connectors for multicore optical fibers and methods thereof

The present invention relates to optical coupling systems that employ a multicore optical fiber. The system can be employed with two multicore optical fibers or with a single multicore optical fiber for use with an optical device. In particular, the system includes connectors having a lens assembly configured to relay optical signals and a ferrule to position the lens assembly. Additional details for making and using such systems are described herein.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Conceptual design of the collection optics for the edge Thomson scattering system in ITER

Neutron and gamma-ray irradiation complicates the design of the edge Thomson scattering (TS) system in ITER. The TS light is relayed through the relaying optics with labyrinth and fiber coupling optics. Electron density of 2x10{sup 19} m{sup -3} is sufficient to measure T{sub e} and n{sub e} within a 10% and 5% margin of error, respectively, with a spatial resolution of 5 mm. This system can cover from 0.85 to 1 of the normalized minor radius. The time resolution is 10 ms, which is determined by the repetition rate of the laser device. A super-Gaussian is the ideal laser profile for the laser injection optics to avoid a breakdown of the filling gas used in density calibration through Raman scattering.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and Construction of a Gamma Reaction History Diagnostic for the National Ignition Facility

Gas Cherenkov detectors have been used to convert fusion gammas into photons to achieve gamma reaction history (GRH) measurements. These gas detectors include a converter, pressurized gas volume, relay optics, and a photon detector. A novel design for the National Ignition Facility (NIF) using 90º Off-Axis Parabolic mirrors efficiently collects signal from fusion gammas with 8-ps time dispersion.1 Fusion gammas are converted to Compton electrons, which generate broadband Cherenkov light (our response is from 250 to 700 nm) in a pressurized gas cell. This light is relayed into a high-speed detector using three parabolic mirrors. The detector optics collect light from a 125-mm-diameter by 600-mm-long interchangeable gas (CO2 or SF6) volume. Because light is collected from source locations throughout the gas volume, the detector is positioned at the stop position rather than at an image position. The stop diameter and its position are independent of the light-generation locations along the gas cell. This design incorporates a fixed time delay that allows the detector to recover from prompt radiation. Optical ray tracings demonstrate how light can be collected from different angled trajectories of the Compton electrons as they traverse the gas volume. A Monte Carlo model of the conversion process from gammas to Cherenkov photons is used to generate photon trajectories. The collection efficiencies for different gamma energies are evaluated. At NIF, a cluster of four channels will allow for increased dynamic range, as well as different gamma energy thresholds. This GRH design is compared to a gas Cherenkov detector that utilizes a Cassegrain reflector now used at the OMEGA laser facility. 1. R. M. Malone, H. W. Herrmann, W. Stoeffl, J. M. Mack, C. S. Young, “Gamma bang time/reaction history diagnostics for the National Ignition Facility using 90º off-axis parabolic mirrors,” Rev. Sci. Instrum. 79, 10E532 (2008).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintillator Efficiency Study with MeV X-Rays

We have investigated scintillator efficiency for MeV radiographic imaging. This paper discusses the modeled detection efficiency and measured brightness of a number of scintillator materials. An optical imaging camera records images of scintillator emission excited by a pulsed x-ray machine. The efficiency of various thicknesses of monolithic LYSO:Ce (cerium-doped lutetium yttrium orthosilicate) are being studied to understand brightness and resolution trade-offs compared with a range of micro-columnar CsI:Tl (thallium-doped cesium iodide) scintillator screens. The micro-columnar scintillator structure apparently provides an optical gain mechanism that results in brighter signals from thinner samples. The trade-offs for brightness versus resolution in monolithic scintillators is straightforward. For higher-energy x-rays, thicker materials generally produce brighter signal due to x-ray absorption and the optical emission properties of the material. However, as scintillator thickness is increased, detector blur begins to dominate imaging system resolution due to the volume image generated in the scintillator thickness and the depth of field of the imaging system. We employ a telecentric optical relay lens to image the scintillator onto a recording CCD camera. The telecentric lens helps provide sharp focus through thicker-volume emitting scintillators. Stray light from scintillator emission can also affect the image scene contrast. We have applied an optical light scatter model to the imaging system to minimize scatter sources and maximize scene contrasts.

scintillator, radiography, CCD camera, hard x-ray,↗