Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical separation techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Hybrid RF / Optical Communication Terminal with Spherical Primary Optics for Optical Reception

Future deep space communications are likely to employ not only the existing RF uplink and downlink, but also a high capacity optical downlink. The Jet Propulsion Laboratory (JPL) is currently investigating the benefits of a ground based hybrid RF and deep space optical terminal based on limited modification of existing 34 meter antenna designs. The ideal design would include as large an optical aperture as technically practical and cost effective, cause minimal impact to RF performance, and remain cost effective even when compared to a separate optical terminal of comparable size. Numerous trades and architectures have been considered, including shared RF and optical apertures having aspheric optics and means to separate RF and optical signals, plus, partitioned apertures in which various zones of the primary are dedicated to optical reception. A design based on the latter is emphasized in this paper, employing spherical primary optics and a new version of a "clamshell" corrector that is optimized to fit within the limited space between the antenna sub-reflector and the existing apex structure that supports the subreflector. The mechanical design of the hybrid accommodates multiple spherical primary mirror panels in the central 11 meters of the antenna, and integrates the clamshell corrector and optical receiver modules with antenna hardware using existing attach points to the maximum extent practical. When an optical collection area is implemented on a new antenna, it is possible to design the antenna structure to accommodate the additional weight of optical mirrors providing an equivalent aperture of several meters diameter. The focus of our near term effort is to use optics with the 34 meter DSS-13 antenna at Goldstone to demonstrate spatial optical acquisition and tracking capability using an optical system that is temporarily integrated into the antenna.

optical communications↗

Machine Straightness Error Measurement Based on Optical Fiber Fabry–Pérot Interferometer Monitoring Technique

Abstract In this research, we propose an Error Separation Technique (EST) based on optical fiber sensors for on-machine straightness error measurement. Two fiber optic Fabry–Pérot interferometers have been developed serving as two displacement sensors. The displacement distance is computed according to the reflected spectrum from interferometers, which can achieve a sub-micrometer resolution. The two-point method has been employed to separate the straightness error of the slides and the profile error of a fine-polished standard block. The spacing distance between two interferometers is determined by the diameter of optical fibers so that the EST's resolution has the potential to reach the sub-millimeter scale. In the experiment, the straightness error has been measured on a commercially available computer numerical control machine tool, and the measurement has been conducted on its x-axis. The spacing distance between two optical fiber sensors is 1.5 mm which equals the EST's resolution along the machine tool's x-axis. The separated profile error of the measured standard block is around 30 µm which has been verified by a high precision Coordinate Measurement Machine (CMM). The magnitude of the separated straightness error is around 40 µm. This technique is flexible and simple to be conducted, which can contribute to the micro-machine tool calibration and other straightness error applications.

Engineering↗

Hyperspectrally-Resolved Surface Emissivity Derived Under Optically Thin Clouds

Surface spectral emissivity derived from current and future satellites can and will reveal critical information about the Earth s ecosystem and land surface type properties, which can be utilized as a means of long-term monitoring of global environment and climate change. Hyperspectrally-resolved surface emissivities are derived with an algorithm utilizes a combined fast radiative transfer model (RTM) with a molecular RTM and a cloud RTM accounting for both atmospheric absorption and cloud absorption/scattering. Clouds are automatically detected and cloud microphysical parameters are retrieved; and emissivity is retrieved under clear and optically thin cloud conditions. This technique separates surface emissivity from skin temperature by representing the emissivity spectrum with eigenvectors derived from a laboratory measured emissivity database; in other words, using the constraint as a means for the emissivity to vary smoothly across atmospheric absorption lines. Here we present the emissivity derived under optically thin clouds in comparison with that under clear conditions.

Zhou, Daniel K.↗

TPSAS-NF1676L-10888-DND

Hyperspectrally-resolved surface emissivities are derived with an algorithm utilizes a combined fast radiative transfer model (RTM) with a molecular RTM and a cloud RTM accounting for both atmospheric absorption and cloud absorption/scattering. Clouds are automatically detected and cloud microphysical parameters are retrieved; and emissivity is retrieved under clear and optically thin cloud conditions. The retrieval technique separates surface emissivity from skin temperature by representing the emissivity spectrum with eigenvectors derived from a laboratory measured emissivity database. Global land emissivities retrieved under the optically thin clouds are investigated by means of their accuracy in comparison with that under cloud-free conditions. Here we present the emissivity derived under optically thin clouds, their accuracy, and the inter-comparison with that under clear conditions.

Daniel K Zhou↗

Liquid-phase turbulence measurements in air-water two-phase flows using particle image velocimetry

Liquid-phase turbulence plays a vital role in determining various gas-liquid two-phase flow parameters, such as void fraction distribution, bubble morphology, bubble-bubble interactions, and interfacial area concentration. In this study, a two-phase flow database including both the gas- and liquid-phases measurements was developed focusing on three bubbly flow conditions in an air-water two-phase flow loop with a vertical one-inch diameter circular pipe test section. A particle image velocimetry (PIV) system integrating an optical phase separation method, i.e., the planar laser-induced fluorescence (PLIF) technique using fluorescent particles and optical filtration, was applied to measure the liquid-phase turbulence information, including the time-averaged velocity, Reynolds stress, and turbulent kinetic energy for the liquid phase. The PIV measurements were taken at three ports along the test section at 14.5, 51.5, and 88.5 pipe inner diameters downstream of a bubble injector. In addition, a double-sensor conductivity probe was used to measure radial distributions of the local time-averaged void fraction and gas velocity. The measured liquid-phase turbulence was used to benchmark Sato's turbulence model considering the bubble-induced shear stress for the three tested bubbly flows. The benchmark results showed good agreement between the PIV measurements and model predictions. Lastly, in the two bubbly flows tested that have low void fractions being less than 3%, the effect of the bubble-induced turbulence was found not significant. However, the bubble-induced shear stress becomes important with the increase of the void fraction.

42 ENGINEERING↗

Extraterrestrial Molecular Indicators of Life Investigation (EMILI)

Future missions to Enceladus, Europa, Mars, and beyond may seek the molecular signs of extraterrestrial life through chemical analysis of acquired samples. Particularly on ocean worlds such as Enceladus and Europa, samples may contain trace ocean-borne molecular biosignatures of extant life that may or may not share similarities to those of terrestrial life. In situ analyses must be prepared to detect and characterize a wide range of possible molecular species, structures, and patterns, typically with exquisite sensitivity and within a complex, poorly-characterized planetary environment. The Extraterrestrial Molecular Indicators of Life Investigation (EMILI) is designed to meet or exceed the requirements of such missions for organic molecular analysis through a powerful combination of dual chemical separation and both optical and mass spectrometry detection techniques, realized in an integrated, compact instrument package fully compatible with anticipated flight resources and conditions. The full EMILI instrument combines two sample analysis subsystems to provide wide-ranging and complementary detection of organic compounds and inorganic salts. The Gas Analysis Processing System (GAPS) uses a chemical derivatization protocol with gas chromatography (GC) separation prior to detection in an ion trap mass spectrometer (ITMS) to enable full characterization of lower-polarity, volatile and semi-volatile molecules such as fatty acids and hydrocarbons. The Organic Capillary Electrophoresis ANalysis System (OCEANS) uses a liquid-based extraction protocol with CE separation to enable precise analysis of more water-soluble/polar compounds. OCEANS features a laser-induced fluorescence detection mode to perform ultra-sensitive quantitative analysis of chiral amino acids. In EMILI, OCEANS is additionally coupled to the same ITMS through a novel electrospray ionization interface. The common ITMS allows EMILI to identify and cross-correlate molecular species and patterns, detected through either or both protocols, of molecular weights to over 1000 u, potentially even revealing complex biosignatures such as alien oligopeptides and informational polymers.

Europa↗

Participation in TOMS missions

In the past year we have been investigating a new algorithm for the derivation of column sulfur dioxide, column ozone, and aerosol optical depth from the Total Ozone Mapping Spectrometer (TOMS) High Density TOMS (HDT) archived albedos. Simulations of the measured albedos were made using a radiative transfer model, and a technique developed to separate the effects of the aerosol optical depth from the absorption optical depth. The retrieval adopted obtained values from the three parameters with high accuracy. This retrieval was then applied to the TOMS data.

Hudson, Robert D.↗

Optical Recognition And Tracking Of Objects

Separate objects moving independently tracked simultaneously. System uses coherent optical techniques to obtain correlation between each object and reference image. Moving objects monitored by charge-coupled-device television camera, output fed to liquid-crystal television (LCTV) display. Acting as spatial light modulator, LCTV impresses images of moving objects on collimated laser beam. Beam spatially low-pass filtered to remove high-spatial-frequency television grid pattern.

Chao, Tien-Hsin↗

Multisensor Instrument for Real-Time Biological Monitoring

The figure schematically depicts an instrumentation system, called a fiber optic-based integration system (FOBIS), that is undergoing development to enable real-time monitoring of fluid cell cultures, bioprocess flows, and the like. The FOBIS design combines a micro flow cytometer (MFC), a microphotometer (MP), and a fluorescence-spectrum- or binding-force-measuring micro-sensor (MS) in a single instrument that is capable of measuring multiple biological parameters simultaneously or sequentially. The fiber-optic-based integration system is so named because the MFC, the MP, and the MS are integrated into a single optical system that is coupled to light sources and photometric equipment via optical fibers. The optical coupling components also include a wavelength-division multiplexer and diffractive optical elements. The FOBIS includes a laserdiode- and fiber-optic-based optical trapping subsystem (optical tweezers ) with microphotometric and micro-sensing capabilities for noninvasive confinement and optical measurement of relevant parameters of a single cell or other particle. Some of the measurement techniques implemented together by the FOBIS have long been used separately to obtain basic understanding of the optical properties of individual cells and other organisms, the optical properties of populations of organisms, and the interrelationships among these properties, physiology of the organisms, and physical processes that govern the media that surround the organisms. For example, flow cytometry yields information on numerical concentrations, cross-sectional areas, and types of cells or other particles. Micro-sensing can be used to measure pH and concentrations of oxygen, carbon dioxide, glucose, metabolites, calcium, and antigens in a cell-culture fluid, thereby providing feedback that can be helpful in improving control over a bioprocess. Microphotometry (including measurements of scattering and fluorescence) can yield further information about optically trapped individual particles. In addition to the multifunctionality not previously available in a single biological monitoring system, the FOBIS offers advantages of low mass, sensitivity, accuracy, portability, low cost, compactness (the overall dimensions of the fully developed FOBIS sensor head are expected to be less than 1 by 1 by 2 cm), and immunity to electromagnetic interference at suboptical frequencies. FOBIS could be useful in a variety of laboratory and field settings in such diverse endeavors as medical, veterinary, and general biological research; medical and veterinary diagnosis monitoring of industrial bioprocesses; and analysis of biological contaminants in air, water, and food.

Zhang, Sean (Zhanxiang)↗

The 27-28 October 1986 FIRE IFO Cirrus Case Study: Cloud Optical Properties Determined by High Spectral Resolution Lidar

During the First ISCCP Region Experiment (FIRE) cirrus intensive field observation (IFO) the High Spectral Resolution Lidar was operated from a roof top site on the University of Wisconsin-Madison campus. Because the HSRL technique separately measures the molecular and cloud particle backscatter components of the lidar return, the optical thickness is determined independent of particle backscatter. This is accomplished by comparing the known molecular density distribution to the observed decrease in molecular backscatter signal with altitude. The particle to molecular backscatter ratio yields calibrated measurements of backscatter cross sections that can be plotted ro reveal cloud morphology without distortion due to attenuation. Changes in cloud particle size, shape, and phase affect the backscatter to extinction ratio (backscatter-phase function). The HSRL independently measures cloud particle backscatter phase function. This paper presents a quantitative analysis of the HSRL cirrus cloud data acquired over an approximate 33 hour period of continuous near zenith observations. Correlations between small scale wind structure and cirrus cloud morphology have been observed. These correlations can bias the range averaging inherent in wind profiling lidars of modest vertical resolution, leading to increased measurement errors at cirrus altitudes. Extended periods of low intensity backscatter were noted between more strongly organized cirrus cloud activity. Optical thicknesses ranging from 0.01-1.4, backscatter phase functions between 0.02-0.065 sr (exp -1) and backscatter cross sections spanning 4 orders of magnitude were observed. the altitude relationship between cloud top and bottom boundaries and the cloud optical center altitude was dependent on the type of formation observed Cirrus features were observed with characteristic wind drift estimated horizontal sizes of 5-400 km. The clouds frequently exhibited cellular structure with vertical to horizontal dimension ratios of 1:5-1:1.

Grund, C. J.↗

Cryogenic star-tracking telescope for Gravity Probe B

This paper describes the design, development and preliminary testing of the cryogenic star-tracking telescope used as an optical reference for the gyroscopes in the Gravity Probe B Relativity Gyroscope experiment. The telescope is operated at 1.8 K; it is fabricated entirely from fused quartz components held together by optical contacting; it has a physical length of 14 in., a focal length of 150 in. and an aperture of 5.6 in. Readout is by two photomultiplier chopper-detector assemblies at ambient satellite temperature. When fully operational, the telescope may be expected to have a precision approaching 0.1 milliarcsec over a linear range of 70 + or 70 milliarcsec. Its projected noise performance corresponds to an angular resolution of 1 milliarcsec in 1 Hz bandwidth. The paper includes a theoretical analysis, a description of the design and fabrication of a laboratory version of the telescope, a discussion of techniques of optical contacting, an account of vibration tests on a separate mass model of the telescope, a description of the artificial star developed for optical tests, and an account of preliminary experimental results.

Everitt, C. W. F.↗

Advanced Instrumentation for Metal Additive Manufacturing

Laser powder bed fusion (LPBF) is the most widely used process for metal additive manufacturing (AM), particularly where complex geometries provide performance advantages unattainable with traditional manufacturing techniques. However, LPBF is highly sensitive to innate variability in both the powder spreading and fusion steps, often leading to defects such as pores that are difficult to detect yet significantly impair component mechanical properties and fatigue life. This thesis presents a range of novel instruments enabling both precise assessment of powder layer characteristics and in-situ thermal metrology of metal AM to advance the quality control of LPBF. First, leveraging a custom X-ray microscope and a radiation-transport model developed through this work, transmission X-ray imaging is used to study spreading of thin metal powder layers. Effective layer depth is directly mapped at a process-relevant size scale, surpassing optical techniques that can only estimate local deposition from layer surface topography. Layer packing density and quality are shown to be influenced by powder flowability and particle size relative to nominal powder layer thickness. Layer quality is additionally connected to the geometry of the spreading implement and its velocity. This technique and its presented findings enable pairing feedstocks with spreading strategies that create layers with consistent packing density and uniformity. Second, a twofold approach is employed to optically interrogate the laser fusion step of LPBF for observing signatures of defect formation. Aperture division multiplexing is conceptualized, providing for simultaneous laser delivery and high-fidelity infrared (IR) process monitoring through a common optic. In-situ microscopy at 50 μm spatial resolution and at mid-wave IR wavelengths is proven readily achievable with the first purpose-built optic of this type. Next, a bespoke imaging spectrometer, along with a temperature-emissivity separation technique, is used to retrieve accurate process temperatures over a 1000 K range. Data from these instruments are correlated to porosity as fine as 4.3 μm in two LPBF test artifacts, as verified using computed tomography (CT), establishing the viability of robust optically-based component qualification.

Penny, Ryan↗

Independent Component Analysis for Preprocessing Optical Signals in Support of Multi-User Communication

In an effort to construct an optical transceiver for supporting multi-point communication, researchers developed large field-of-view FSO transceivers with wide apertures for facilitating rapid acquisition and optical signal tracking. The design is constructed from fiber-bundle(s) intelligently arranged to provide multiple optical pathways within a single transceiver, with each pathway limited to a particular optical directionality. Because designs with wide apertures are susceptible to receiving several optical signals simultaneously from multiple transmitters, accurately decoding individual signals and achieving true multi-user communication can be difficult. The work detailed in this paper investigated the use of blind source separation techniques, mainly independent component analysis (ICA), to estimate transmitted signals from their observed, combined mixtures sans information. Effects of signal power, format, data rate, wavelength, and turbulence severity on signal separation, as well as signal demodulation accuracy was also analyzed using experimental optical signals and corresponding mixtures. Signal generators, laser sources, turbulence emulator, beam profiler, photodiodes, and oscilloscopes comprised the experiment setup. Optical signals with varying power, format, and wavelength were generated and propagated through turbulence with varying degree severity, and finally received by the fiber-bundle-based optical transceiver. Results demonstrate that an ICA technique can accurately process the combined signals into corresponding individual components. The investigation further identified signal characteristics (e.g., power levels, format, data rate) and turbulence severity under which ICA is unable to accurately perform signal separations.

Optics↗

MUSE adaptive-optics spectroscopy confirms dual active galactic nuclei and strongly lensed systems at sub-arcsec separation

The novel Gaia multi peak (GMP) technique has proven to be able to successfully select dual and lensed active galactic nuclei (AGN) candidates at sub-arcsecond separations. Both populations are important because dual AGN represent one of the central, still largely untested, predictions of ΛCDM cosmology, and compact lensed AGN allow us to probe the central regions of the lensing galaxies. In this work, we present high-spatial-resolution spectroscopy of 12 GMP-selected systems. We used the adaptive-optics assisted integral-field spectrograph MUSE at the VLT to resolve each system and investigate the nature of each component. All targets show the presence of two components confirming the GMP selection. We classify 4 targets as dual AGN, 3 as lensed quasar candidates, and 5 as a chance alignment of a star and an AGN. With separations ranging from 0.30″ to 0.86″, these dual and lensed systems are among the most compact systems discovered to date at z > 0.5. This is the largest sample of distant dual AGN with sub-arcsecond separations ever presented in a single paper.

Scialpi, M. (ORCID:0009000651004986)↗

Linear capacitive displacement sensor with frequency readout

A simple, inherently linear technique for measuring changes in the separation of the mirrors of an optical cavity is reported. The capacitor, made up of the reflective metallic coatings, is part of a feedback loop which adjusts the frequency of an oscillator to be proportional to the mirror separation. A linearity of 0.2 percent full scale was achieved for separations up to 0.5 mm with a resolution of 10 nm.

Fritsch, Klaus↗

Integrated Grating Spectrometer

Proposed integrated grating spectrometer made in waveguide layer on silicon wafer. Occupies area of about 2 centimeters to 2nd power on wafer 0.4 mm thick. Operates in visible spectrum (wavelengths of 400 to 700 nm) and blazed to diffract in first order. Array of integrated grating spectrometers performs spectral analysis of picture elements along line. Optical fiber couples light from each picture element into separate integrated spectrometer. Technique enables continous independent variation, along grating, of pitch, curvature, and blaze angle. Grating designed to have large numerical aperture, zero aberration at two selected wavelengths, and very low aberration at intermediate wavelengths.

Lang, Robert J.↗