Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A Synthetic Pathway for Producing Carbon Dots for Detecting Iron Ions Using a Fiber Optic Spectrometer

Iron detection is of growing importance in the critical minerals sector, where unwanted iron ions are typically removed during the processing of target critical metals. The ideal sensor should utilize inexpensive, scalable materials along with a low-cost, robust, and easy-to-use analysis platform. Here, we demonstrate a simple acid–base synthesis of luminescent iron-responsive carbon dots by reacting ethanolamine, phosphoric acid, and m-phenylenediamine. The carbon dots exhibit selective, iron-specific emission quenching, with the ability to detect part-per-billion levels of iron ions even in 0.1 M HCl. After benchmarking the purified materials using a commercial spectrometer, a “low-cost” process is demonstrated in which carbon dots with minimal purification are coupled with a portable fiber-optic spectrometer for analyzing iron content. Carbon dot-coated paper strips are also evaluated as another convenient platform for iron analysis. Taken together, the sensing material and platforms demonstrated here are well-suited for detecting trace quantities of iron in environmentally relevant conditions, with potential applications in tracking iron removal processes during critical mineral production as one exciting area of interest.

acid mine draining↗

Optical Spectrometer With a Pulse-to-Pulse Resolution for Terahertz and mm-Wave Signals

The development of ultra-compact particle accelerators and accelerator-based high-power THz generators are some of the top priorities for research and development programs around the world. These tools require the development of accelerating structures, operating in the mm-Wave and THz range, where diagnostics are not available or are insufficient. This article presents the design of a pulse-to-pulse THz spectrometer, primarily developed for diagnostics of accelerating structures and THz radiation sources. In particular, this spectrometer can be used to detect RF pulse shortening caused by vacuum breakdown and beam misalignment in THz accelerators, as well as for bunch length monitoring and radiation source diagnostics. The spectrometer is based on a diffraction grating and is capable of covering a frequency range where RF-based breakdown measurements are not possible. We have built and tested the first prototype with different sources in a frequency range of 0.1-1.0 THz. In this article, we present the physical design, supported numerical simulations, electronics development, and test results.

47 OTHER INSTRUMENTATION↗

Sensitivity Limitation of an Optical Heterodyne Spectrometer

We show an optical heterodyne spectrometer with picometer resolution and high sensitivity. Moreover, we report the quantum limit of detecting multi-mode light using heterodyne detection, and compare it to a typical down conversion source output.

Chapman, Joseph↗

Cloud Condensation Nuclei and Printed Optical Particle Spectrometer Measurements at Mt. Soledad during EPCAPE 2023-24

These measurements are provided by a differential mobility analyzer operated as a scanning mobility particle sizer, a printed particle optical spectrometer (POPS), and a continuous flow diffusion cloud condensation nuclei (CCN) counter. The instruments sample from either a counterflow virtual impactor inlet or an isokinetic inlet. The measurements provide the mobility aerosol size distribution (30-360 nm), optical size distribution (150 - 6000 nm), size-resolved CCN distribution (30-360 nm) at 0.2, 0.4, 0.6, 0.8, and 1.0% supersaturation. CCN measurements are performed in denuded and undenuded configuration, where denuded refers to the removal of low molecular weight organic vapors. A detailed NetCDF header is included with the datafiles. Users of these measurements are encouraged to consult with the authors about appropriate interpretation before submitting for publication, offering coauthorship where appropriate.

54 ENVIRONMENTAL SCIENCES↗

Characterization of a modified printed optical particle spectrometer for high-frequency and high-precision laboratory and field measurements

Abstract. The printed optical particle spectrometer (POPS) is a lightweight, low-cost instrument for measurements of aerosol number concentrations and size distributions. This work reports on modifications of the Handix Scientific commercial version of the POPS to facilitate its use in multi-instrument aerosol sampling systems. The flow system is modified by replacing the internal pump with a needle valve and a vacuum pump. The instrument is integrated into closed-flow systems by routing the sheath flow from filtered inlet air. A high-precision multichannel analyzer (MCA) card is added to sample the analog pulse signal. The MCA card is polled at 10 Hz frequency using an external data acquisition system and improves upon the count-rate limitation associated with the POPS internal data acquisition system. The times required to change the concentration between 90 % and 10 % and vice versa for a step change in concentration were measured to be 0.17 and 0.41 s at a flow rate of 5 cm3 s−1. This yields a sampling frequency of ∼ 1–2 Hz, below which the amplitude of measured fluctuations is captured with > 70 % efficiency. The modified POPS was integrated into the dual tandem differential mobility analyzer system to explore the coalescence of dimer particles. Results show that the pulse-height response increases upon dimer coalescence. The magnitude of the increase is broadly consistent with the change in light-scattering amplitude predicted by the T-matrix method. It is anticipated that this modified version of the POPS will extend the utilization of the technique for a range of field and laboratory applications.

54 ENVIRONMENTAL SCIENCES↗

Network of Modified Portable Optical Particle Spectrometers Instrument Handbook

The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s portable optical particle spectrometer (POPS) network (Figure 1) provides an aerosol size distribution spectrum from 150 nm to 5 μm in 16 logarithmically spaced bins. The data emanating from this network of up to four matching POPS in weatherproof enclosures comprises one-minute averages of the aerosol size and number spectrum and the co-located temperature and relative humidity. The total particle concentration and sample flow rate are also provided. The sample stream is not dried before its measurement. Two size spectra are provided: the default size distribution corresponds to the calibration using polystyrene latex spheres (PSL), while the second size distribution corresponds to the calibration using size-selected dry ammonium sulfate aerosol. The principal scientific application of the data provided by the ARM POPS is to determine the aerosol size distribution across a region in three disparate locations – the size distribution is broadly relevant to studies of pollution and of conditions in the boundary layer. A high particle concentration can be an indicator of unhealthy levels of pollution; the dispersion of particles in the atmosphere is a predictor of long-range visibility; and particles serve as collectors of condensing gases including water vapor, and thus are a factor in the formation and properties of fogs and clouds, and in the initiation of precipitation.

54 ENVIRONMENTAL SCIENCES↗

Portable Optical Particle Spectrometer aboard an Airborne Platform (POPS_AIR) Instrument Handbook

The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility portable optical particle spectrometer (POPS) is a lightweight particle spectrometer designed for aerosol particle size distribution measurement. Several POPS of different versions have been procured to serve as routine instruments for the ARM Aerial Facility (AAF) unmanned aerial systems (UAS) and tethered balloon system (TBS) deployment since 2018. POPS measures the aerosol particle size distribution approximately between 0.13 and 3 μm.

54 ENVIRONMENTAL SCIENCES↗

Performance Assessment of Portable Optical Particle Spectrometer (POPS)

Accurate representation of atmospheric aerosol properties is a long-standing problem in atmospheric research. Modern pilotless aerial systems provide a new platform for atmospheric in situ measurement. However, small airborne platforms require miniaturized instrumentation due to apparent size, power, and weight limitations. A Portable Optical Particle Spectrometer (POPS) is an emerged instrument to measure ambient aerosol size distribution with high time and size resolution, designed for deployment on a small unmanned aerial system (UAS) or tethered balloon system (TBS) platforms. This study evaluates the performance of a POPS with an upgraded laser heater and additional temperature sensors in the aerosol pathway. POPS maintains its performance under different environmental conditions as long as the laser temperature remains above 25 °C and the aerosol flow temperature inside the optical chamber is 15 °C higher than the ambient temperature. The comparison between POPS and an Ultra-High Sensitivity Aerosol Spectrometer (UHSAS) suggests that the coincidence error is less than 25% when the number concentration is less than 4000 cm –3 . The size distributions measured by both of them remained unaffected up to 15,000 cm –3 . While both instruments’ sizing accuracy is affected by the aerosol chemical composition and morphology, the influence is more profound on the POPS.

47 OTHER INSTRUMENTATION↗

High-speed fiber-based spectrometer for plasma Thomson scattering

Here we present a novel concept for a Thomson scattering diagnostic, based on a high-speed fiber optic spectrometer. The high-speed fiber optic spectrometer presented here translates a spectral measurement from the frequency domain into the time domain, thus requiring the use of only a single photodetector for spectral acquisition. The high temporal precision offered by the instrument gives rise to a number of advantages over traditional spectrometers, such as nearly background-free measurements and multiple uses of the same injected beam. Multiple uses of the same beam would enable greatly increased measurement rates, in the range of 10–100 MHz. The spectral range and resolution of the fiber spectrometer can be easily tailored to be optimized for the light source and experimental conditions by selecting different lengths of fiber, thus allowing for the proposed technique to exhibit high dynamic range when measuring many points simultaneously. Finally, due to the temporal separation of the background from the signal, these improvements are possible without the need for increased average input laser power.

47 OTHER INSTRUMENTATION↗

The SuperCam Instrument Suite on the NASA Mars 2020 Rover: Body Unit and Combined System Tests

The SuperCam instrument suite provides the Mars 2020 rover, Perseverance, with a number of versatile remote-sensing techniques that can be used at long distance as well as within the robotic-arm workspace. These include laser-induced breakdown spectroscopy (LIBS), remote time-resolved Raman and luminescence spectroscopies, and visible and infrared (VISIR; separately referred to as VIS and IR) reflectance spectroscopy. A remote micro-imager (RMI) provides high-resolution color context imaging, and a microphone can be used as a stand-alone tool for environmental studies or to determine physical properties of rocks and soils from shock waves of laser-produced plasmas. SuperCam is built in three parts: The mast unit (MU), consisting of the laser, telescope, RMI, IR spectrometer, and associated electronics, is described in a companion paper. The on-board calibration targets are described in another companion paper. Here we describe SuperCam’s body unit (BU) and testing of the integrated instrument. The BU, mounted inside the rover body, receives light from the MU via a 5.8 m optical fiber. The light is split into three wavelength bands by a demultiplexer, and is routed via fiber bundles to three optical spectrometers, two of which (UV and violet; 245–340 and 385–465 nm) are crossed Czerny-Turner reflection spectrometers, nearly identical to their counterparts on ChemCam. The third is a high-efficiency transmission spectrometer containing an optical intensifier capable of gating exposures to 100 ns or longer, with variable delay times relative to the laser pulse. This spectrometer covers 535–853 nm ( $105\text{--}7070~\text{cm}^{-1}$ Raman shift relative to the 532 nm green laser beam) with $12~\text{cm}^{-1}$ full-width at half-maximum peak resolution in the Raman fingerprint region. The BU electronics boards interface with the rover and control the instrument, returning data to the rover. Thermal systems maintain a warm temperature during cruise to Mars to avoid contamination on the optics, and cool the detectors during operations on Mars.Results obtained with the integrated instrument demonstrate its capabilities for LIBS, for which a library of 332 standards was developed. Examples of Raman and VISIR spectroscopy are shown, demonstrating clear mineral identification with both techniques. Luminescence spectra demonstrate the utility of having both spectral and temporal dimensions. Finally, RMI and microphone tests on the rover demonstrate the capabilities of these subsystems as well.

47 OTHER INSTRUMENTATION↗

Adaptive thermal stabilization of an integrated photonic spectrometer using parasitic interference fringes

Parasitic fringe drift from unwanted scatterings limits the long-term stability of waveguide-based optical spectrometers. Yet their spectral features provide relevant information that can be used to improve performance of the spectrometer. We show that fringe drift can be extracted and utilized to perform accurate thermal stabilization, especially in the case of integrated waveguide sensors. In this Letter, effective stabilization of a methane silicon photonic sensor is demonstrated, and significant reduction in fringe noise is clearly observed.

Teng, Chu C.↗

Novel design for a polarizing DUV spectrometer using a Wollaston prism and its application as a diagnostic for measuring Thomson scattering data in the presence of strong self-emission backgrounds

We present a novel design for an optical spectrometer for use in ultraviolet Thomson scattering measurements of plasma parameters in high energy density (HED) inertial confinement fusion experiments on large-scale high-energy laser facilities. In experiments investigating high-Z plasmas, the fidelity of measurements is commonly limited by signal/background ratios approaching or exceeding unity. An alpha barium borate Wollaston prism can provide both spectral dispersion and polarization channel separation, allowing simultaneous measurement of both the Thomson scattering signal and plasma self-emission along a single line of sight and in a single experiment, which should greatly improve data quality and reduce the opportunity cost of taking high quality measurements. Here, we present a basic discussion of the design and a worked example of an instrument designed to take fourth harmonic electron plasma wave measurements in HED experiments at the OMEGA laser facility.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Photon counting with intensified charge coupled device (ICCD) – II. Laser induced breakdown spectroscopy (LIBS) spectral measurement

This study explores the application of photon counting (PC) to enhance the resolution of spectra acquired by an intensified charge-coupled device (ICCD) detector, with a focus on analytical atomic emission spectrometry using laser-induced breakdown spectroscopy (LIBS) as a use-case example. It demonstrates that, for spectra obtained with the same spectrometer–ICCD system, PC provides higher spectral resolution compared to conventional analog detector readout. This enhancement is particularly evident in the line wings of spectral peaks, facilitating better discrimination of isotopic peaks in the measured spectra. Although PC does not improve the resolution of an optical spectrometer directly, it rectifies the resolution lost caused by signal spreading in conventional ICCD analog measurement. However, similar to other counting techniques, excessive photons compromise detector linearity due to signal pileup. A correction model is proposed to mitigate the pileup effect, resulting in improved linearity and dynamic range in PC measurements. Additionally, the study reveals unexpected periodic structures in the flatfield image of the ICCD, which cause non-uniform detector gain in conventional analog as well as PC measurement modes and must be addressed for high-precision measurements.

47 OTHER INSTRUMENTATION↗

Aerosol Microphysics and Chemical Measurements at Mt. Soledad and Scripps Pier during the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE) from February 2023 to February 2024 UCSD Library Collection

This dataset includes guest instrument measurements and other PI products for aerosol microphysics and chemical measurements collected at Mt. Soledad and Scripps Pier during the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE) from February 2023 to February 2024. The measurements include the following instruments at Mt. Soledad: High-Resolution Time-of-Flight Aerosol Mass Spectrometer (HR-ToF-AMS, Aerodyne), Scanning Electrical Mobility Spectrometer (SEMS, Brechtel Manufacturing Inc.), Aerodynamic Particle Sizer (APS, Droplet Measurements Technologies), Single Particle Soot Photometer (SP2, Drople Measurements Technologies), Meteorological Station (WXT520, Vaisala), Ozone (Teco), and trace gas proxies (Teledyne). In addition, the analyses of particle filters collected at Mt. Soledad for three dry-diameter size cuts (<1 micron, <0.5 micron, <0.18 micron) and at Scripps Pier for one dry-diameter size cut (<1 micron) by Fourier Transform Infrared (FTIR) and X-ray Fluorescence (XRF) are reported. A differential mobility analyzer operated as a scanning mobility particle sizer (SMPS, TSI Inc.), a printed particle optical spectrometer (POPS, Grimm), and a continuous flow diffusion cloud condensation nuclei (CCN, DMT) counter provide the mobility aerosol size distribution (30-360 nm), optical size distribution (150 - 6000 nm), size-resolved CCN distribution (30-360 nm) at 0.2, 0.4, 0.6, 0.8, and 1.0% supersaturation. Measurements are reported for both sampling from an isokinetic aerosol inlet and from a Counterflow Virtual Impactor (CVI, Brechtel Manufacturing Inc.). The data are available at the following link: https://library.ucsd.edu/dc/collection/bb0898306q

54 ENVIRONMENTAL SCIENCES↗

Luminescent Materials for the Detection of Economically Critical Metals in Harsh Environments

Renewable energy technologies used for electric vehicles and wind turbines are heavily reliant upon metals, such as rare earth elements, cobalt, lithium, and nickel. Indeed, there are 50 minerals that are currently considered “economically critical” by the 2022 United States Geological Survey. With anticipated global adoption of renewable energy technologies, producing sufficient metals to meet this demand presents a significant challenge, particularly due to the current monopolistic market for many of these metals. The production of metals from unconventional sources, such as coal utilization byproducts, is one of many promising strategies to boost domestic supply. However, sensitive, rapid, and inexpensive characterization technologies are needed to minimize production costs associated with metals prospecting and processing. Photoluminescence-based sensing techniques are particularly intriguing due to their potential for low cost and portability, coupled with high sensitivity and selectivity. This presentation focuses on the development of high-performance sensing materials for a range of critical metals, including metal-organic frameworks capable of sensitizing detection of parts-per-billion concentrations of six different rare earth elements, nanoparticles that can detect down to 600 parts-per-billion levels of cobalt, and thin films that sense aluminum down to 120 parts-per-billion. These materials are highly selective, capable of withstanding low pH conditions, and provide a response within minutes. Importantly, each sensing material is integrated with a custom-built, fully portable fiber-optic spectrometer for potential field deployment, providing significant cost savings over commercial instruments, along with potential advantages such as material regeneration for use across multiple sensing cycles and solvent removal for enhanced emission signal. These results highlight the exciting potential of luminescence platforms as cost-effective alternatives for metals characterization.

Crawford, Scott↗