Neutron powder diffraction, Mossbauer Spectroscopy and Optical Spectroscopy to study magnetic and nuclear lattices in Fe-based oxychlorides Ca2FeO3Cl, Sr2FeO3Cl and Sr3Fe2O5Cl2

Data for Neutron Diffraction, Mossbauer Spectoscopy and Optical Spectroscopy are contained on all three samples (Ca2FeO3Cl, Sr2FeO3Cl, and Sr3Fe2O5Cl2). Mossbauer data are in the folder "MossbauerSpectroscopy". This contains details of files and examples to read the data. The Optical Spectroscopy are in the folder "AbsorptionData", this contains one file with explanatory headers. The neutron diffraction data are in the "NeutronDiffractionData" folder. The data was collected on the HB-2A powder diffractometer at HFIR. The autoreduced files are corrected using a vanadium standard and are in arbitrary intensity units. The RawData folder contains the uncorrected data with metadata for motor positions and temperature. All measurements were collected with a constant neuton wavelength of 2.41 Angstrom. An excel spreadsheet "NeutronDiffractionData_IPTS-29118_summary" contains details for each scan. Sr3Fe2O5Cl2 data were collected at only room temperature. Ca2FeO3Cl and Sr2FeO3Cl data were collected at 4K and room temperature. The autoreduced .dat fileformat is three columns corresponding to: Two-theta, Intensity and Intensity_error.

fe-based oxychlorides↗

Direct Observation of Plasma-Stimulated Activation of Surface Species Using Multimodal In Situ/Operando Spectroscopy Combining Polarization-Modulation Infrared Reflection-Absorption Spectroscopy, Optical Emission Spectroscopy, and Mass Spectrometry

Nonthermal plasmas (NTPs) produce reactive chemical environments, including electrons, ions, radicals, and vibrationally excited molecules, that can drive chemistry at temperatures at which such species are thermally inaccessible. There has been growing interest in the integration of conventional catalysis with reactive NTPs to promote novel chemical transformations. Unveiling the full potential of plasma-catalytic processes requires a comprehensive understanding of plasma-catalytic synergies, including characterization of plasma-catalytic surface interactions. In this work, we report on a newly designed multimodal spectroscopic instrument combining polarization-modulation infrared reflection-absorption spectroscopy (PM-IRAS), mass spectrometry, and optical emission spectroscopy (OES) for the investigation of plasma–surface interactions such as those found in plasma catalysis. In particular, this tool has been utilized to correlate plasma-phase chemistry with both surface chemistry and gas-phase products in situ (1) during the deposition of carbonaceous surface species via NTP-promoted nonoxidative coupling of methane and (2) during subsequent activation of surface deposits with an atmospheric pressure and temperature argon plasma jet on both nickel (Ni) and silicon dioxide (SiO 2 ) surfaces. For the first time, the activation of carbonaceous surface species by a NTP on Ni and SiO 2 surfaces to form hydrogen gas and C 2 hydrocarbons was directly observed, where both PM-IRAS and OES measurements suggest that they may form through different pathways. Furthermore, this unique tool for studying plasma–surface interactions could enable more rational design of plasma-stimulated catalytic processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Consistency between reflection momentum-resolved electron energy loss spectroscopy and optical spectroscopy measurements of the long-wavelength density response of Bi 2 Sr 2 CaCu 2 O 8 + x

The density fluctuation spectrum captures many fundamental properties of strange metals. Using momentum-resolved electron energy-loss spectroscopy (M-EELS), we recently showed that the density response of the strange metal Bi 2 Sr 2 CaCu 2 O 8+x (Bi-2212) at large momentum, q, exhibits a constant-in-frequency continuum reminiscent of the marginal Fermi liquid (MFL) hypothesis of the late 1980s. However, reconciling this observation with infrared (IR) optics experiments, which show a well-defined plasmon excitation at q ~ 0, has been challenging. Here we report M-EELS measurements of Bi-2212 using 4× improved momentum resolution, allowing us to reach the optical limit. For momenta q < 0.04 r.l.u., the M-EELS data show a plasmon feature that is quantitatively consistent with IR optics. For q > 0.04 r.l.u., the spectra become incoherent with an MFL-like, constant-in-frequency form. Here we speculate that, at finite frequency, ω, and nonzero q, some attribute of this Planckian metal randomizes the probe electron, causing it to lose information about its own momentum.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Inferring relative dose-dependent color center populations in proton irradiated thoria single crystals using optical spectroscopy

In this work, we have utilized photoluminescence spectroscopy and optical ellipsometry to characterize the dose-dependence of the photoluminescence emission intensity and changes in optical absorption of thoria single crystals subject to irradiation with energetic protons at room- and elevated-temperatures. The photoluminescence peaks and the optical absorption bands are attributed to creation of new electronic states emerging from defects resulting from displacement damage. These bands are most likely associated with electrons trapped at the oxygen vacancy sites similar to color centers formed in other irradiated oxides and halides. Our experimental observations are supported by a standard density functional theory calculation of the electronic structure in pristine and oxygen vacancy-bearing thoria crystals. The dose-dependence of the intensity of the photoluminescence peaks is used to parameterize a rate theory model that estimates the concentration of color centers in the irradiated crystals. This parameterization provides optimized migration barrier parameters for oxygen interstitials and vacancies that simultaneously capture the optical response of the crystals irradiated at room- and elevated-temperature. These optical spectroscopy techniques offer a promising pathway to characterize the population of color centers formed at the sites of oxygen anion vacancies, particularly in irradiated nuclear fuels, where atomic-level defects cannot be readily imaged using electron microscopy. When combined with other direct and indirect characterization tools, our approach can provide new insight into defect formation and accumulation in energy materials over single atomic to extended length scales.

36 MATERIALS SCIENCE↗

Elucidating the Role of Hydrogen Bonding in the Optical Spectroscopy of the Solvated Green Fluorescent Protein Chromophore: Using Machine Learning to Establish the Importance of High-Level Electronic Structure

Hydrogen bonding interactions with chromophores in chemical and biological environments play a key role in determining their electronic absorption and relaxation processes, which are manifested in their linear and multidimensional optical spectra. For chromophores in the condensed phase, the large number of atoms needed to simulate the environment has traditionally prohibited the use of high-level excited-state electronic structure methods. By leveraging transfer learning, we show how to construct machine-learned models to accurately predict the high-level excitation energies of a chromophore in solution from only 400 high-level calculations. Here, we show that when the electronic excitations of the green fluorescent protein chromophore in water are treated using EOM-CCSD embedded in a DFT description of the solvent the optical spectrum is correctly captured and that this improvement arises from correctly treating the coupling of the electronic transition to electric fields, which leads to a larger response upon hydrogen bonding between the chromophore and water.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Camera, handlens, and microscope optical system for imaging and coupled optical spectroscopy

An optical system comprising two lens cells, each lens cell comprising multiple lens elements, to provide imaging over a very wide image distance and within a wide range of magnification by changing the distance between the two lens cells. An embodiment also provides scannable laser spectroscopic measurements within the field-of-view of the instrument.

Mungas, Greg S.↗

Camera, handlens, and microscope optical system for imaging and coupled optical spectroscopy

An optical system comprising two lens cells, each lens cell comprising multiple lens elements, to provide imaging over a very wide image distance and within a wide range of magnification by changing the distance between the two lens cells. An embodiment also provides scannable laser spectroscopic measurements within the field-of-view of the instrument.

Mungas, Greg S.↗

Dynamic optical spectroscopy and pyrometry of static targets under optical and x-ray laser heating at the European XFEL

Experiments accessing extreme conditions at x-ray free electron lasers (XFELs) involve rapidly evolving conditions of temperature. Here, we report time-resolved, direct measurements of temperature using spectral streaked optical pyrometry of x-ray and optical laser-heated states at the High Energy Density instrument of the European XFEL. This collection of typical experiments, coupled with numerical models, outlines the reliability, precision, and meaning of time dependent temperature measurements using optical emission at XFEL sources. Dynamic temperatures above 1500 K are measured continuously from spectrally- and temporally-resolved thermal emission at 450–850 nm, with time resolution down to 10–100 ns for 1–200 μs streak camera windows, using single shot and integrated modes. Targets include zero-pressure foils free-standing in air and in vacuo, and high-pressure samples compressed in diamond anvil cell multi-layer targets. Radiation sources used are 20-fs hard x-ray laser pulses at 17.8 keV, in single pulses or 2.26 MHz pulse trains of up to 30 pulses, and 250-ns infrared laser single pulses. A range of further possibilities for optical measurements of visible light in x-ray laser experiments using streak optical spectroscopy are also explored, including for the study of x-ray induced optical fluorescence, which often appears as background in thermal radiation measurements. We establish several scenarios where combined emissions from multiple sources are observed and discuss their interpretation. Challenges posed by using x-ray lasers as non-invasive probes of the sample state are addressed.

47 OTHER INSTRUMENTATION↗

Viewing Optical Processes at the Nanoscale: Combining Scanning Tunneling Microscopy and Optical Spectroscopy

The combination of optical spectroscopy and scanning tunneling microscopy techniques has the potential to yield the unambiguous single-molecule level insight required to fully understand the complex structure–property relationship of emerging material systems. In this Perspective, we highlight the recent progress of single-molecule absorption detected by scanning tunneling microscopy (SMA-STM) to investigate light–matter interactions of supported (nano)particles, quantum dots, and molecular and thin films at the nanoscale. We further show how the SMA-STM technique has been recently extended to expand the classes of materials that can be investigated as well as recent design modifications that enable both time-resolved imaging and tomography. Finally, we hypothesize how these modifications can be further leveraged to advance our current knowledge of light–matter interactions and how the resulting nanoscale insight can be implemented for future material applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimizing the sensitivity of high repetition rate broadband transient optical spectroscopy with modified shot-to-shot detection

A major limitation of transient optical spectroscopy is that relatively high laser fluences are required to enable broadband, multichannel detection with acceptable signal-to-noise levels. Under typical experimental conditions, many condensed phase and nanoscale materials exhibit fluence-dependent dynamics, including higher order effects such as carrier–carrier annihilation. With the proliferation of commercial laser systems, offering both high repetition rates and high pulse energies, have come new opportunities for high sensitivity pump-probe measurements at low pump fluences. However, experimental considerations needed to fully leverage the statistical advantage of these laser systems have not been fully described. Here, we demonstrate a high repetition rate, broadband transient spectrometer capable of multichannel shot-to-shot detection at 90 kHz. Importantly, we find that several high-speed cameras exhibit a time-domain fixed pattern noise resulting from interleaved analog-to-digital converters, which is particularly detrimental to the conventional “ON/OFF” modulation scheme used in pump-probe spectroscopy. Using a modified modulation and data processing scheme, we achieve a noise level of 10−5 in 4 s for differential transmission, an order of magnitude lower than for commercial 1 kHz transient spectrometers for the same acquisition time. We leverage the high sensitivity of this system to measure the differential transmission of monolayer graphene at low pump fluence. We show that signals on the order of 10−6 OD can be measured, enabling a new data acquisition regime for low-dimensional materials.

47 OTHER INSTRUMENTATION↗

The neutral hydrogen mass in galaxies estimated via optical spectroscopy

ABSTRACT We propose to employ emission line luminosities obtained via optical spectroscopy to estimate the content of neutral hydrogen (H i) in galaxies. We use the optical spectroscopy data from the Mapping of Nearby Galaxies at APO (MaNGA) survey released in the frames of public DR17 of the Sloan Digital Sky Survey (SDSS). We compare the H i mass estimated by us for a large sample of SDSS/MaNGA galaxies with direct H i measurements from the Arecibo Legacy Fast ALFA survey and find a tight correlation between the masses with the correlation coefficient (CC) of 0.91 and the rms scatter of 0.15 dex for the logarithmic mass. The obtained relationship is verified via another sample of MaNGA galaxies with H i masses measured with the Green Bank Telescope. Despite the coarser angular resolution of the radio data, the relation between the estimated and measured directly H i mass is tight as well – in this case CC = 0.74 and the rms is 0.29 dex. The established relations allow us to estimate the total mass of neutral hydrogen as well as the spatial distribution of H i surface density in galaxies from optical spectroscopic observations only in a simple and efficient way.

Bizyaev, Dmitry (ORCID:000000023601133X)↗

Optical Spectroscopy and X-Ray Observations of the D-Type Symbiotic Star EF Aql

We performed high-resolution optical spectroscopy and X-ray observations of the recently identified Mira-type symbiotic star EF Aql. Based on high-resolution optical spectroscopy obtained with SALT, we determine the temperature (~55 000 K) and the luminosity (~5.3 L⨀) of the hot component in the system. The heliocentric radial velocities of the emission lines in the spectra reveal possible stratification of the chemical elements. We also estimate the mass-loss rate of the Mira donor star. Our Swift observation did not detect EF Aql in X-rays. The upper limit of the X-ray observations is 10(exp -12) erg cm(exp -2) s(exp -1), which means that EF Aql is consistent with the faintest X-ray systems detected so far. Otherwise, we detected it with the UVOT instrument with an average UVM2 magnitude of 14.05. During the exposure, EF Aql became approximately 0.2 UVM2 magnitudes fainter. The periodogram analysis of the V-band data reveals an improved period of 320.4±0.3 d caused by the pulsations of the Mira-type donor star. The spectra are available upon request from the authors.

Symbiotic binary stars↗

Automated Calibration for Rapid Optical Spectroscopy Sensor Development for Online Monitoring

An automated platform has been developed to assist researchers in the rapid development of optical spectroscopy sensors to quantify species from spectral data. This platform performs calibration and validation measurements simultaneously. Real-time, in situ monitoring of complex systems through optical spectroscopy has been shown to be a useful tool; however, building calibration models requires development time, which can be a limiting factor in the case of radiological or otherwise hazardous systems. While calibration time can be reduced through optimized design of experiments, this study approached the challenge differently through automation. The ATLAS (Automated Transient Learning for Applied Sensors) platform used pneumatic control of stock solutions to cycle flow profiles through desired calibration concentrations for multivariate model construction. Additionally, the transients between desired concentrations based on flow calculations were used as validation measurements to understand model predictive capabilities. This automated approach yielded an incredible 76% reduction in model development time and a 60% reduction in sample volume versus estimated manual sample preparation and static measurements. The ATLAS system was demonstrated on two systems: a three-lanthanide system with Pr/Nd/Ho representing a use case with significant overlap or interference between analyte signatures and an alternate system containing Pr/Nd/Ni to demonstrate a use case in which broad-band corrosion species signatures interfered with more distinct lanthanide absorbance profiles. Both systems resulted in strong model prediction performance (RMSEP < 9%). Lastly, ATLAS was demonstrated as a tool to simulate process monitoring scenarios (e.g., column separation) in which models can be further optimized to account for day-to-day changes as necessary (e.g., baseline correction). Ultimately, ATLAS offers a vital tool to rapidly screen monitoring methods, investigate sensor fusion, and explore more complex systems (i.e., larger numbers of species).

47 OTHER INSTRUMENTATION↗

Demonstration of Non-linear Optical Spectroscopy Enhancement utilizing Entangled Photons

Laser-based nonlinear optical spectroscopy approaches have enabled the direct sensing of important chemistry in nearly every fundamental or applied field of science. Yet in many applications, increased detectivity is needed to unravel fundamental mechanisms. One possibility is the use of quantum entanglement to increase detection cross-sections, but it is unproven that enhancement from quantum light extends to practical intensities for chemical sensing. In this report, we investigated the creation and use of entangled photons in nonlinear optical mixing for second harmonic generation and infrared imaging. We observe that the linear scaling of nonlinear mixing from entangled photon sources extends to the mW laser power regime, and enhances direct infrared imaging on Si-based charge coupled device cameras. These results motivate future experimentation on practical uses of entangled photons for nonlinear optical sensing applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultrafast temporal phase-resolved nonlinear optical spectroscopy in the molecular frame

In an ultrafast nonlinear optical interaction, the electric field of the emitted nonlinear signal provides direct access to the induced nonlinear transient polarization or transient currents and thus carries signatures of ultrafast dynamics in a medium. Measurement of the electric field of such signals offers sensitive observables to track ultrafast electron dynamics in various systems. In this work, we resolve the real-time phase of the electric field of a femtosecond third-order nonlinear optical signal in the molecular frame. The electric field emitted from impulsively pre-aligned gas-phase molecules at room temperature, in a degenerate four-wave mixing scheme, is measured using a spectral interferometry technique. The nonlinear signal is measured around a rotational revival to extract its molecular-frame angle dependence from pump-probe time-delay scans. By comparing these measurements for two linear molecules, carbon dioxide and nitrogen, we show that the measured second-order phase parameter (temporal chirp) of the signal is sensitive to the valence electronic symmetry of the molecules, whereas the amplitude of the signal does not show such sensitivity. We compare measurements to theoretical calculations of the chirp observable in the molecular frame. This work is an important step towards using electric field measurements in nonlinear optical spectroscopy to study ultrafast dynamics of electronically excited molecules in the molecular frame.

47 OTHER INSTRUMENTATION↗

Selective electron-phonon coupling strength from nonequilibrium optical spectroscopy: The case of MgB 2

The coupling between quasiparticles and bosonic excitations rules the energy transfer pathways in condensed matter systems. The possibility of inferring the strength of specific coupling channels from their characteristic timescales measured in nonequilibrium experiments is still an open question. Here, in this study, we investigate MgB 2 , in which conventional superconductivity at temperatures as high as 39 K is mediated by the strong coupling between the conduction electrons and the 𝐸 2⁢𝑔 phonon mode. By means of broadband time-resolved optical spectroscopy, we show that this selective electron-phonon coupling dictates the nonequilibrium optical response of MgB 2 at early times (<100 fs) after photoexcitation. Furthermore, based on an effective temperature model analysis, we estimate its contribution to the total electron-boson coupling function extracted from complementary equilibrium spectroscopy approaches, namely, optical reflectivity and angle-resolved photoemission spectroscopy. The coupling strength with the 𝐸 2⁢𝑔 phonon modes is thus estimated to be 𝜆 ≃ 0.56, which is approximately half of the total coupling constant, in agreement with 𝑎𝑏 initio calculations from the literature. As a benchmark, broadband time-resolved optical spectroscopy is performed also on the isostructural and nonsuperconducting compound AlB 2 , showing that the nonequilibrium optical response relaxes on a slower timescale due to the lack of strongly coupled phonon modes. Our findings demonstrate the possibility to resolve and quantify selective electron-phonon coupling from nonequilibrium optical spectroscopy.

Mor, Selene [Università Cattolica del Sacro Cuore,↗

Phase resolved optical spectroscopy of the compact X-ray binary 2A1822-371

The optical, X-ray, and ultraviolet emissions of the X-ray system 2A1822-371 are modulated with a period of 5.57 hr. The 5.57 hr modulation is believed to reflect orbital motion about a mass donating companion star. The modulation at high energies is caused by the combined effects of an occultation by the companion and by a bulge on the accretion disk. The present investigation is concerned with an extension of the study of 2A1822-371, taking into account medium resolution optical spectroscopy of the system covering the 5.57 hr cycle. Broad shallow absorption lines are observed in the optical spectrum of 2A1822-371. These lines are similar to the rotationally broadened lines which are found in the spectra of disk accreting cataclysmic variables. Their presence in 2A1822-371 is, therefore, strong confirmation that it is a disk accreting star. The He II 4686 A and H-alpha emission lines have a breadth comparable to the absorption lines at all phases in the 5.57 hr cycle.

Mason, K. O.↗