Search NASASearch

SEARCH · Search NASA

Results for “optical state estimation and correction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Noise Constraints on Sensitivity Scaling in Quantum Nonlinear Metrology

Quantum-enhanced metrology surpasses classical metrology by improving estimation precision scaling with a resource 𝑁 (e.g., particle number or energy) from 1/√𝑁 to 1/𝑁. Through the use of nonlinear effects, Roy and Braunstein [Exponentially enhanced quantum metrology, Phys. Rev. Lett. 100, 220501 (2008)] derived a 1/𝑁 2 scaling. However, later works argued this exponential improvement is unphysical and that even modest gains, like 1/𝑁 2 , may vanish under noise. We show that, in the presence of small errors, the nonlinear interactions enabling metrological enhancement induce emergent errors. Here, the errors propagate through the sensing protocol and are magnified proportional to any intended nonlinear enhancement. We identify a critical value of the parameter to be estimated, for a fixed error, below which the emergent errors can be avoided.

Quantum Fisher information

Size-Transferable Prediction of Excited State Properties for Molecular Assemblies with a Machine Learning Exciton Model

Computational modeling of the excited states of molecular aggregates faces significant computational challenges and size heterogeneity. Current machine learning (ML) models, typically trained on specific-sized aggregates, struggle with scalability. We found that the exciton model Hamiltonian of large aggregates can be decomposed into dimer pairs, allowing an ML model trained on dimers to reconstruct Hamiltonians for aggregates of any size. We also proposed a new method to address the phase-correction problem by introducing coupling terms’ approximations. Our model accurately predicted the excitation energies of the trimer and tetramer of perylene and tetracene and estimated S1 oscillator strengths of perylene aggregates. Leveraging our ML model, the optical gaps of nanosized perylene aggregates with up to 50 monomers are analyzed, qualitatively revealing the role of different couplings on their size dependency. Future work will explore transferability across different monomers to predict optical properties in heterogeneous assemblies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

Energy shift of Fe-K fluorescence lines due to low ionization demonstrated with XRISM in Centaurus X-3

The Fe K$\alpha$ fluorescence line at 6.4 keV is a powerful probe of cold matter surrounding X-ray sources and has been widely used in various astrophysical contexts. The X-ray microcalorimeter spectrometer onboard XRISM can measure line shifts with unprecedented precision of ${\sim }$0.2 eV, equivalent to a line-of-sight velocity of ${\sim }$10 km s$^{-1}$. At this level of accuracy, however, several factors that influence the line energy must be carefully considered prior to astrophysical interpretation. One such important factor is the ionization degree, Fe$^{q+}$. The K$\alpha$ line shifts redward by ${\sim }$4 eV as q increases from 0 (neutral) to 8 (Ar-like). Additionally, the accompanying Fe K$\beta$ line at 7.06 keV shifts blueward by ${\sim }$30 eV from $q=0$ to 8. We demonstrate that this effect is actually observable in the XRISM data of the high-mass X-ray binary Centaurus X-3 (Cen X-3). We advocate that the differential energy shift between the K$\alpha$ and K$\beta$ line provides a robust estimate of q by decoupling from other effects that shift the two lines in the same direction. We derived $q \sim 5$ (Sc-like) for the fluorescing matter by comparing the observation with atomic structure calculations of our own and in the literature. By accounting for the derived charge state and the corresponding shift in the rest-frame line energy, we made corrections for this effect and reached a consistent residual shift among the K$\alpha$, K$\beta$, and the optical measurement attributable to the systemic velocity of the system. Consequently, we obtained a new constraint on the location of the cold matter. This ionization effect needs to be assessed in all use cases of the Fe K$\alpha$ line shift beyond Cen X-3, and the proposed metric is generally applicable to all of them.

Astronomy and AstroPhysics

Improved heavy-ion PID using scintillation light detector with neural network analysis: a Monte Carlo simulation study

The photon collection efficiency of gaseous scintillator detectors varies according to the position of the impinging charged particles in the medium that generates scintillation light. Thus, when impinging particles are distributed over a large area, the intrinsic photon-number resolution of the system is affected by a large variation. This work presents and discusses a method for adjusting the total number of detected photons to account for variation in the photon collection efficiency as a function of the position of the light source within the scintillating medium. The method was developed and validated by processing data from systematic simulation studies based on GEANT4 that model the response of the Energy Loss Optical Scintillation System (ELOSS) detector. The position of the charged particle is calculated using a deep neural network algorithm. This is accomplished by analyzing the distribution of scintillation light recorded by the array of photosensors. The estimated particle position is then used to calculate the correction factor and adjust the amount of captured light to account for variations in the photon collection efficiency. The neural network algorithm provides excellent tracking capabilities, achieving sub-millimeter position resolution and an angular resolution of 12 mrad, approaching the performance of traditional tracking detectors (e.g., drift chambers). The present method can be generalized to any optical scintillation system where the photon collection efficiency depends on the position of the impinging particle.

Heavy-ion detectors

A Measurement of the Largest-scale CMB E -mode Polarization with CLASS

We present measurements of large-scale cosmic microwave background E-mode polarization from the Cosmology Large Angular Scale Surveyor 90 GHz data. Using 115 det-yr of observations collected through 2024 with a variable-delay polarization modulator, we achieved a polarization sensitivity of 82 μK arcimin, comparable to Planck at similar frequencies (100 and 143 GHz ). The analysis demonstrates effective mitigation of systematic errors and addresses challenges to large-angular-scale power recovery posed by time-domain filtering in maximum-likelihood map-making. A novel implementation of the pixel-space transfer matrix is introduced, which enables efficient filtering simulations and bias correction in the power spectrum using the quadratic cross-spectrum estimator. Overall, we achieved an unbiased time-domain filtering correction to recover the largest angular scale polarization, with the only power deficit, arising from map-making nonlinearity, being characterized as <3%. Through cross-correlation with Planck, we detected the cosmic reionization at 99.4% significance and measured the reionization optical depth τ = $0.053^{+0.018}_{-0.019}$, marking the first ground-based attempt at such a measurement. At intermediate angular scales (ℓ > 30), our results, both independently and in cross-correlation with Planck, remain fully consistent with Planck’s measurements.

79 ASTRONOMY AND ASTROPHYSICS

Orbital Inverse Faraday and Cotton-Mouton Effects in Hall Fluids

We report two light-induced orbital magnetization effects in quantum Hall (QH) fluids, stemming from their transverse response. The first is a purely transverse contribution to the inverse Faraday effect (IFE), where circularly polarized light induces a dc magnetization by stirring the charged fluid. This contribution dominates the IFE in the QH regime. The second is the orbital inverse Cotton-Mouton effect (ICME), in which linearly polarized light generates a dc magnetization. Since the applied field in the ICME does not break time-reversal symmetry, the induced magnetization directly probes the chiral orbital response of the fluid at the driving frequency. We estimate that the resulting magnetization lies in the range of 0.5–10 Bohr magnetons per charge carrier in materials such as graphene and transition-metal dichalcogenides (TMDs) in the QH regime. Finally, we show that the induced magnetization is accompanied by a local correction to the static particle density, enabling optical quantum printing of density profiles into the QH fluid.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND

Error and Correction Analysis for the FFA@CEBAF Energy Upgrade

An energy upgrade design for the Continuous Electron Beam Accelerator Facility (CEBAF) is under development, using fixed field alternating gradient (FFA) return arcs to recirculate electron beam up to an additional five times through the accelerating structures at CEBAF. A necessary component of any large accelerator is a beam steering and optical correction system. Small environmental changes and system errors can lower beam quality or even shut down the machine; and in pursuit of the scientific mission of JLab, high quality electron beams must be delivered to the experimental halls on a predictable schedule. Correction in the novel FFA arcs of the current upgrade design is complicated by several factors. These complexities inform the choice of correction algorithm structure and parameter values. A baseline algorithm in addition to diagnostic and correction hardware configuration is presented. The effect of this correction protocol is shown with respect to estimated errors, and several possible extensions of the algorithm are discussed. This work presents an important proof of concept for the FFA@CEBAF design effort, and provides a functional correction strategy which may be simply adjusted and optimized for future design changes.

Coxe, Alex [Old Dominion Univ., Norfolk, VA (Unite

In situ quantum verification of polarization-stabilized optical channels

The active stabilization of polarization channels is a task of growing importance as quantum networks move to deployed demonstrations over existing fiber infrastructure. However, the uniquely strict requirements for high-fidelity qubit transmission complicate the extent to which classical solutions may apply to future quantum networks, particularly in terms of recognizing noise sources present in low-flux, nonunitary channels. Here we introduce an in situ benchmarking approach that augments a classical polarization tracking system, limited to unitary correction, with simultaneously transmitted quantum light for ancilla-assisted process tomography of the full quantum map. Implemented in a quantum local-area network, our method uses the reconstructed map both to validate the classical compensation and to expose noise sources it fails to capture. A sliding measurement window that continuously updates the estimated quantum process further increases sensitivity to rapid channel fluctuations. Our results should unlock new opportunities for in situ channel characterization in quantum-classical coexistence networks.

Stevens, Matthew L [Arizona State University]

Robust Measurement of Stellar Streams around the Milky Way: Correcting Spatially Variable Observational Selection Effects in Optical Imaging Surveys

Observations of density variations in stellar streams are a promising probe of low-mass dark matter substructure in the Milky Way. However, survey systematics such as variations in seeing and sky brightness can also induce artificial fluctuations in the observed densities of known stellar streams. These variations arise because survey conditions affect both object detection and star–galaxy misclassification rates. To mitigate these effects, we use Balrog synthetic source injections in the Dark Energy Survey (DES) Y3 data to calculate detection rate variations and classification rates as functions of survey properties. We show that these rates are nearly separable with respect to survey properties and can be estimated with sufficient statistics from the synthetic catalogs. Applying these corrections reduces the standard deviation of relative detection rates across the DES footprint by a factor of 5, and our corrections significantly change the inferred linear density of the Phoenix stream when including faint objects. Additionally, for artificial streams with DES-like survey properties we are able to recover density power spectra with reduced bias. We also find that uncorrected power-spectrum results for Legacy Survey of Space and Time (LSST)-like data can be around 5 times more biased, highlighting the need for such corrections in future ground-based surveys.

79 ASTRONOMY AND ASTROPHYSICS

Warped and Hooked: Mapping the Magellanic Clouds in Three Dimensions Using Red Clump Stars

The Large Magellanic Cloud (LMC) and Small Magellanic Cloud (SMC) are the Milky Way’s nearest interacting galaxy pair, offering a unique laboratory for studying tidal effects on galactic disks. Despite extensive survey efforts, the 3D geometry of the Magellanic Clouds, particularly the putative warp of the LMC, remains poorly constrained due to incompleteness in their crowded centers and the low stellar density of their peripheries, which demand wide-field coverage. Using red clump (RC) stars as standard candles, corrected for age- and metallicity-dependent population effects with empirically calibrated color–magnitude relations and spatially resolved star formation histories, we construct the most detailed distance map of the Magellanic system to date. Based on ∼2.3 million RC stars from Gaia Data Release 3 combined with modern reddening maps, we measure median heliocentric distances of 50.62 ± 2.32 kpc for the LMC (to ∼23°) and 60.75 ± 2.85 kpc for the SMC (to ∼12°). The maps reveal substructures including the LMC Northern Arm, southern hooks, the Magellanic Bridge, and SMC peripheral overdensities, with refreshed distance estimates. Fitting the LMC disk within 7° yields a global inclination of $i=25\mathop{.}\limits^{^\circ }32\pm 0\mathop{.}\limits^{^\circ }10$ and a line-of-nodes position angle of $\theta = 142\mathop{.}\limits^{^\circ }34\pm 0\mathop{.}\limits^{^\circ }21$. Most strikingly, we find the LMC periphery is warped azimuthally into a U-shaped structure reaching a vertical amplitude of ∼7 kpc at a radius of ∼15 kpc. In future work, we will perform detailed comparisons with live N-body simulations to assess possible formation scenarios for the LMC warp.

79 ASTRONOMY AND ASTROPHYSICS

Iron-corrected Single-epoch Black Hole Masses of DESI Quasars at Low Redshift

We present a study on the possible overestimation of single-epoch supermassive black hole (SMBH) masses in previous works, based on more than 55,000 type 1 quasars at 0.25 < z < 0.8 from the Dark Energy Spectroscopic Instrument (DESI). We confirm that iron emission strength serves as a good tracer of the Eddington ratio, and estimate SMBH masses using an iron-corrected R–L relation for Hβ, where R is the broad-line region size and L is the continuum luminosity. Compared with our measurements, previous canonical measurements without the iron correction are overestimated by a factor of 1.5 on average. The overestimation can be up to a factor of 5 for super-Eddington quasars. The fraction of super-Eddington quasars in our sample is about 5%, significantly higher than 0.4% derived from the canonical measurements. Using a sample featuring both Hβ and Mg II emission lines, we calibrate Mg II -based SMBH masses using iron-corrected, Hβ-based SMBH masses and establish an iron-corrected R–L relation for Mg II . The revised relation features a flatter luminosity dependence with a slope of 0.36 and incorporates an additional term of −0.21R Fe , where R Fe denotes the relative iron strength. We use this formula to build a catalog of about 0.5 million DESI quasars at 0.6 < z < 1.6. If these iron-corrected R–L relations for Hβ and Mg II are valid at high redshift, current mass measurements of luminous quasars at z ≥ 6 would have been overestimated by a factor of 2.3 on average, alleviating the tension between SMBH mass and growth history in the early universe.

active galactic nuclei

Comparing the DES-SN5YR and Pantheon+ SN cosmology analyses: investigation based on ‘evolving dark energy or supernovae systematics’?

Recent cosmological analyses measuring distances of type Ia supernovae (SNe Ia) and baryon acoustic oscillations (BAO) have all given similar hints at time-evolving dark energy. To examine whether underestimated SN Ia systematics might be driving these results, Efstathiou (2025) compared overlapping SN events between Pantheon+ and DES-SN5YR (20 per cent SNe are in common), and reported evidence for an $\sim$0.04 mag offset between the low- and high-redshift distance measurements of this subsample of events. If this offset is arbitrarily subtracted from the entire DES-SN5YR sample, the preference for evolving dark energy is reduced. In this paper, we show that this offset is mostly due to different corrections for Malmquist bias between the two samples; therefore, an object-to-object comparison can be misleading. Malmquist bias corrections differ between the two analyses for several reasons. First, DES-SN5YR used an improved model of SN Ia luminosity scatter compared to Pantheon+ but the associated scatter-model uncertainties are included in the error budget. Secondly, improvements in host mass estimates in DES-SN5YR also affected SN standardized magnitudes and their bias corrections. Thirdly, and most importantly, the selection functions of the two compilations are significantly different, hence the inferred Malmquist bias corrections. Even if the original scatter model and host properties from Pantheon+ are used instead, the evidence for evolving dark energy from CMB, DESI BAO Year 1 and DES-SN5YR is only reduced from 3.9$\sigma$ to 3.3$\sigma$, consistent with the error budget. Finally, in this investigation, we identify an underestimated systematic uncertainty related to host galaxy property uncertainties, which could increase the final DES-SN5YR error budget by 3 per cent. In conclusion, we confirm the validity of the published DES-SN5YR results.

79 ASTRONOMY AND ASTROPHYSICS

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER