Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical tolerances”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

GFOC Project results: High Temperature / High Pressure, Hydrogen Tolerant Optical Fiber

Tests results are given for exposure of multimode optical fiber to high temperatures (300 deg. C) and high partial pressure (15 bar) hydrogen. These results demonstrate that fluorine down doped optical fibers are much more hydrogen tolerant than traditional germanium doped multimode optical fibers. Also demonstrated is the similar hydrogen tolerance of carbon coated and non-carbon coated fibers. Model for reversible H2 impact in fiber versus T{sup o}C and H2 pressure is given. These results have significant impact for the longevity of use for distributed temperature sensing applications in harsh environments such as geothermal wells.

08 HYDROGEN↗

Fault-tolerant optical interconnects for neutral-atom arrays

We analyze the use of photonic links to enable large-scale fault-tolerant connectivity of locally error-corrected modules based on neutral atom arrays. Our approach makes use of recent theoretical results showing the robustness of surface codes to boundary noise and combines recent experimental advances in atom-array quantum computing with logical qubits with optical quantum networking techniques. We find the conditions for fault tolerance can be achieved with local two-qubit Rydberg gate and nonlocal Bell-pair errors below 1% and 10%, respectively, without requiring distillation or space-time overheads. Realizing the interconnects with a lens, a single optical cavity, or an array of cavities enables—with sufficient multiplexing—a Bell-pair generation rate in the 1–50 MHz range. When directly interfacing logical qubits, this rate translates to error-correction cycles in the 25–2000 kHz range, satisfying all requirements for fault tolerance and in the upper range fast enough for 100 kHz logical clock cycles. Published by the American Physical Society 2025

Sinclair, Josiah (ORCID:0000000215238295)↗

100 Gbps Radiation Tolerant Optical Transceiver (Final Technical Report)

The overall technical objective in phase I for the Surface Emitting Laser-Electro-Absorption Modulator (EAM) was to demonstrate feasibility of this approach by designing and building the laser-EAM chips, optimizing the fabrication process for the Laser/EAM in a series of 3 fabrication runs, irradiating Laser/EAM chips from each run and DC testing of the chips post radiation. 100 Gbps/channel testing would be done at the end of the phase II program before and after radiation. The overall technical objective for the driver circuit was to demonstrate the radiation tolerance of a circuit using the same technology as the driver, and to design the appropriate driver circuit.

43 PARTICLE ACCELERATORS↗

A study of radiation tolerance in optical cements

We study the effect ionizing radiation has on light transmission in the wavelength range 190–1100 nm for a number of optically clear epoxies. We find that the transmittance of traditional, commercially available, optical epoxies show significant degradation for exposures of 1×10 12 MIPs/cm 2 . Degradation of light transmission progresses from the shortest wavelengths at low doses to longer wavelengths as the dose increases. In epoxy joints that are 0.1 mm thick, we observe that more than 5% of the light is lost for wavelengths less than 400 nm for traditional optical epoxies. Our studies have identified an optically clear epoxy that shows little degradation for radiation exposures up to 5.9× 10 14 MIPs/cm 2 (≈ 220 kGy).

Radiation-hard detectors↗

A Common Sense Approach to Radiotherapy Planning of Glioblastoma Multiforme Situated in The Temporal Lobe

Purpose: Irradiation remains the cornerstone of management for glioblastoma multiforme. The Radiation Therapy Oncology Group and European Organization for Research and Treatment of Cancer advocate encompassing the primary tumor plus a 2-cm margin in the high-dose volume. One shortcoming of this approach is the exposure of critical structures to radiation doses that could exceed organ tolerance. We investigated whether the temporal bone (rather than the aforementioned 2-cm radius) would serve as a barrier to tumor spread when regarded as the anterior margin for temporal lobe lesions. We hypothesized that by using the temporal bone as the radiation field margin, toxicity could be reduced without compromising tumor control. Methods and Materials: Between 2003 and 2007, 342 patients with newly diagnosed glioblastoma multiforme were treated with surgery and primary irradiation at our institution. Of these 342 patients, 50 had lesions confined to the temporal lobe. The clinical target volume included the primary lesion, the area of edema when present, and a 2-cm margin, except in the direction of the temporal bone. Results: Of the 50 patients, 40 were available for evaluation. At a median follow-up of 12.95 months, 8 patients had not yet shown signs of tumor progression, 24 had local failure, 7 had distant or mixed (local plus distant) failure, and only 1 patient had failure in the infratemporal fossa. Conclusions: The results of the study have demonstrated an acceptable level of recurrence when the temporal bone, rather than a 2-cm margin, is used as the anterior border of the clinical target volume. The strategy we have proposed achieves tumor control and respects optic tolerance without resorting to complex, expensive approaches such as intensity-modulated radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficient Fresnel zoneplate pattern data preparation for high-resolution nanofabrication

A Fresnel zoneplate is a diffractive optical element consisting of concentric rings (zones) for which the transmitted light produces a focal spot that is used in all wavelength regimes, including X-rays. The pattern of transmission openings determines the location of the spot and the sub-half wavelength size of the openings can adjust the intensity. Today, very general transmission zoneplate patterns are used for many special imaging and image compensation purposes. Manufacturing zoneplates require a zoneplate pattern file, which precisely describes the size, shape, and contour of the rings based on the desired optical properties of the lens. Generating such a pattern requires the delicate balance of achieving the required optical performance while maintaining manageable file sizes and computation times. Here we describe a new algorithm meeting these needs. In conclusion, by precisely controlling the number of shapes in each zone, the algorithm simultaneously optimizes the desired optical tolerances with the pattern file size.

47 OTHER INSTRUMENTATION↗

FELIX: a PCIe based high-throughput approach for interfacing front-end and trigger electronics in the ATLAS Upgrade framework

The ATLAS Phase-I upgrade (2019) requires a Trigger and Data Acquisition (TDAQ) system able to trigger and record data from up to three times the nominal LHC instantaneous luminosity. Furthermore, the Front-End LInk eXchange (FELIX) system provides an infrastructure to achieve this in a scalable, detector agnostic and easily upgradeable way. It is a PC-based gateway, interfacing custom radiation tolerant optical links from front-end electronics, via PCIe Gen3 cards, to a commodity switched Ethernet or InfiniBand network. FELIX enables reducing custom electronics in favour of software running on commercial servers. Here, the FELIX system, the design of the PCIe prototype card and the integration test results are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Versatile Link+ Transceiver Production Readiness

The Versatile Link + project is about to enter its production phase, ready for the Phase 2 HL-LHC detector upgrades. We present the status of the front-end part of the Versatile Link$^+$ project: the Versatile Link$^+$ Transceiver, which provides a low-mass, radiation tolerant, optical transmit- and receive module for tight integration in the upgrading HL-LHC detectors. We describe the development and thorough testing carried out with the transceiver prototypes and their sub-components and the design decisions that have led to the final production-ready prototype. The planned production schedule is also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Installation and Initial Operation of an On-line Target Imaging System for SNS

After several years of operation, the SNS now enters an era of megawatt class operation. At this intensity level, the target will be operating closer to its engineering limits and the beam profile on target must be carefully controlled. During commissioning and early operations, a temporary imaging system was used to measure the proton density on target. This system was not designed to survive the increasing power levels and it had to be removed in the second half of 2006. Since then, no direct measurement of beam properties at the target has been available. A collaboration was forged to remedy this situation, and has resulted in a new imaging system consisting of three major components: a thermal-sprayed luminescent coating deposited on the target nose, a radiation-tolerant optical system installed upstream of the target, and an image acquisition system integrated with the accelerator controls network. The design, installation, and integration of these components will be described. Initial beam measurements and image analysis results will be presented. Lessons learned during this initial operating experience have been documented and will guide the collaboration s future plans.

43 PARTICLE ACCELERATORS↗

Wave-optical assessment of alignment tolerances in nano-focusing with ellipsoidal mirror

High-precision ellipsoidal mirrors, which can efficiently focus X-rays to the nanometer dimension with a mirror, have not been realized because of the difficulties in the fabrication process. The purpose of our study was to develop nano-focusing ellipsoidal mirrors in the hard X-ray region. We developed a wave-optical focusing simulator for investigating alignment tolerances in nano-focusing with a designed ellipsoidal mirror, which produce a diffraction-limited focus size of 30 × 35 nm{sup 2} in full width at half maximum at an X-ray energy of 7 keV. The simulator can calculate focusing intensity distributions around the focal point under conditions of misalignment. The wave-optical simulator enabled the calculation of interference intensity distributions, which cannot be predicted by the conventional ray-trace method. The alignment conditions with a focal length error of ≲ ±10 µm, incident angle error of ≲ ±0.5 µrad, and in-plane rotation angle error of ≲ ±0.25 µrad must be satisfied for nano-focusing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Assembly and testing of a large zoom lens for proton radiography

A zoom lens has been designed for proton radiography applications. Radiographic images are recorded at the end of an accelerator, where protons exit an aluminum vacuum window, producing a shadowgraph image onto an LYSO (lutetium yttrium orthosilicate) scintillator. Emission from this 5-inch-square scintillator reflects off a pellicle and is then collected by a zoom lens located 24 inches away. Proton radiography can make high-speed, multi-frame radiographs or radiographic movies. This zoom lens provides 2X magnification for viewing different object sizes. The zoom lens incorporates eleven lenses, including a moving doublet that changes the magnification. Refocus of the camera is required when zooming. Only one moving doublet lens is required to change magnification. The stop was anchored to the moving doublet, and its diameter is unchanged throughout magnification changes. The entire lens system is housed in a cylindrical tube. This lens will be used with a 10-frame camera with a 44 × 44 mm square image format and 1100 × 1100 pixel resolution. Suppressing stray light is very important in this lens system. Radial compensation is controlled by two locking micrometers on element 9, which relaxes the mechanical tolerancing. A helical cam barrel using a linear rail controls the movement of the doublet. Alignment of the mechanical gears will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fiber-optic bolometers with high-temperature tolerance and reduced time constants for fusion plasma diagnostics

Fiber-optic bolometers (FOBs) designed for plasma radiation measurement in magnetically confined fusion environments have been previously developed and tested at the DIII-D tokamak. These FOBs utilize a silicon Fabry–Perot interferometer at the fiber tip for temperature measurement and a gold disk as a radiation absorber. This paper presents recent advancements in the development of FOBs with reduced cooling time constants and enhanced temperature tolerance. We also demonstrate high-temperature operation and report findings from irradiation tests. By incorporating a copper sensor holder as a thermal sink and integrating two closely packed sensor heads into a compact design, the cooling time constants were reduced to ∼100 ms in vacuum, while minimizing uncertainties caused by temperature gradients. The FOBs were subjected to heating at 400 °C for five hours, with no observed degradation in noise performance post-heating. High-temperature operation tests were conducted at ∼220 °C using a 404 nm square-wave modulated laser to simulate the plasma radiation. In addition, four FOBs constructed from copper-coated pure-silica fibers were fabricated and underwent irradiation testing, enduring a total γ-radiation dose of 15.2 MGy and a neutron fluence of 1.6 × 10 18 n/cm 2 . As a result, the FOBs maintained their physical integrity and the optical signal shows high visibility throughout the test.

42 ENGINEERING↗

Compact millimeter-wavelength Fourier-transform spectrometer

Here, we have constructed a Fourier-transform spectrometer (FTS) operating between 50 GHz and 330 GHz with minimum volume (355×260×64 mm) and weight (5.9 kg) while maximizing optical throughput (100 mm 2 sr) and optimizing the spectral resolution (4 GHz). This FTS is designed as a polarizing Martin–Puplett interferometer with unobstructed input and output in which both input polarizations undergo interference. The instrument construction is simple with mirrors milled on the box walls and one motorized stage as the single moving element. We characterize the performance of the FTS, compare the measurements to an optical simulation, and discuss features that relate to details of the FTS design. The simulation is also used to determine the tolerance of optical alignments for the required specifications. We detail the FTS mechanical design and provide the control software as well as the analysis code online.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Robustness of Optical Response for Self-Assembled Plasmonic Metamaterials with Morphological Disorder and Surface Roughness

Bottom-up fabrication of metallized biotemplated nanostructures to form specific plasmonic nanoresonators holds promise as a means of achieving large-scale optical metamaterials. However, in contrast to top-down methods, the stochastic growth of self-assembled nanoresonators is prone to significant disorder and surface roughness, which naturally raise an important question about the robustness of their resonant properties in terms of structural imperfections. An aggregated-random-sphere model is developed to mimic the nucleated growth of metallized DNA origami assembly, leading to meta-atoms with realistic, experimentally observed morphological disorder and surface roughness. Using the well-known split-ring-resonator (SRR) motif as an example, the resonant properties of meta-atoms under different levels of roughness are investigated and a strong tolerance of optical response against morphological disorder is revealed. It is found that in SRRs, even with dramatic roughness introduced, the expected resonances are still observed, despite broadening line shapes compared to ideal smooth structure. Only for extreme disorder, which causes drastic segmentation of SRRs, does the resonant response disappear. Finally, the demonstrations are very encouraging for the prospects of bottom-up fabrication toward versatile functional metamaterials and metadevices.

36 MATERIALS SCIENCE↗

WE-F-304-03: Optic Nerve/Chiasm Hypofractionated SRS/SRT Dose Tolerance

Stereotactic Body Radiation Therapy (SBRT) was introduced clinically more than twenty years ago, and many subsequent publications have reported safety and efficacy data. The AAPM Working Group on Biological Effects of Hypofractionated Radiotherapy/SBRT (WGSBRT) extracted published treatment outcomes data from extensive literature searches to summarize and construct tumor control probability (TCP) and normal tissue complication probability (NTCP) models for six anatomical regions: Cranial, Head and Neck, Thoracic, Abdominal, Pelvic, and Spinal. In this session, we present the WGSBRT’s work for cranial sites, and recurrent head and neck cancer. From literature-based data and associated models, guidelines to aid with safe and effective hypofractionated radiotherapy treatment are being determined. Further, the ability of existing and proposed radiobiological models to fit these data is considered as to the ability to distinguish between the linear-quadratic and alternative radiobiological models such as secondary cell death from vascular damage, immunogenic, or bystander effects. Where appropriate, specific model parameters are estimated. As described in “The lessons of QUANTEC,” (1), lack of adequate reporting standards continues to limit the amount of useful quantitative information that can be extracted from peer-reviewed publications. Recommendations regarding reporting standards are considered, to enable such reviews to achieve more complete characterization of clinical outcomes. 1 Jackson A, Marks LB, Bentzen SM, Eisbruch A, Yorke ED, Ten Haken RK, Constine LS, Deasy JO. The lessons of QUANTEC: recommendations for reporting and gathering data on dose-volume dependencies of treatment outcome. Int J Radiat Oncol Biol Phys. 2010 Mar 1;76(3 Suppl):S155–60. Learning Objectives: Describe the techniques, types of cancer and dose schedules used in treating recurrent H&N cancers with SBRT List the radiobiological models that compete with the linear-quadratic model in explaining the results of hypofractionated RT Describe the dose/volume metrics that are considered safe in SBRT treatment of tumors near the optic structures. Discuss the efficacy of hypofractionation and dosing schedules used in treating vestibular schwannomas Identify some difficulties in modeling TCP and NTCP for cranial tumors treated with hypofractionation. One moderator, Dr. Grimm, designed and holds intellectual property rights to the DVH Evaluator software tool which is an FDA-cleared product in commercial use, and can analyze some of this data. No others have relevant conflicts of interest.

60 APPLIED LIFE SCIENCES↗

Strain Measurement in the Spallation Target Using High-Radiation-Tolerant Fiber Sensors

We describe the measurement of fast dynamic strains in the mercury target module of the spallation neutron source using customized high-radiation-tolerant fiber-optic strain sensors. The sensors are made from fluorine-doped single-mode optical fibers that demonstrated high radiation tolerance at 1300 nm. A digital phase demodulation scheme is employed in the signal interrogation system, which enables high bandwidth measurement and has an excellent adaptability to sensor output power fluctuations and sensor gap variations. Fast transient strain waveforms induced by high-energy, high-intensity proton pulses are successfully measured. Here, the sensors have survived radiation doses of 10 9 Gy. Both measurement bandwidth and radiation tolerance of the sensors are an order of magnitude higher than their commercial counterparts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗