Significance of the Direct Excitation Mechanism for High-Frequency Response of Premixed Flames to Flow Oscillations

Premixed flames are sensitive to flow disturbances, which can arise from acoustic or vortical fluctuations. For transverse instabilities, it is known that a dominant mechanism for flame response is “injector coupling,” whereby pressure oscillations associated with transverse waves excite axial flow disturbances. These axial flow disturbances then excite heat release oscillations. The objective of this paper is to consider another mechanism—the direct sensitivity of the unsteady heat release to transverse acoustic waves—and to compare its significance relative to the induced axial disturbances, in a linear framework. The rate at which the flame adds energy to the disturbance field is quantified using the Rayleigh criterion and evaluated over a range of control parameters, such as flame length and swirl number. The results show that radial modes induce heat release fluctuations that always add energy to the acoustic field, whereas heat release fluctuations induced by mixed radial-azimuthal modes can add or remove energy. These amplification rates are then compared to the flame response from induced axial fluctuations. For combustor-centered flames, these results show that the direct excitation mechanism has negligible amplification rates relative to the induced axial mechanism for radial modes. For transverse modes, the fact that the nozzle is located at a pressure node indicates that negligible induced axial velocity disturbances are excited; as such, the direct mechanism dominates. As a result, for flames that are not centered on pressure nodes, the direct mechanism for mixed modes dominates for certain nozzle locations and flame angles.

42 ENGINEERING↗

Robust foil regenerator flow loss and heat transfer tests under oscillating flow condition

A regenerator works as an energy storage component in a Stirling engine. Thus, it is one of the most critical components that makes the Stirling engine highly efficient. Traditionally, the regenerators are made of wire media such as woven screens and random fibers. These wire regenerators experience considerably high flow losses through the regenerator due to the flow separation and the resulting vortices. The high flow losses associated with the flow separation and vortices result in a lower engine efficiency. This research is to test a new robust foil regenerator to investigate its feasibility for free-piston Stirling engine applications. The robust foil regenerator is configured with parallel flow channels and stiffening ribs. Comparing to complex flows patterns in woven screen and random fiber regenerators, the flows in the parallel plates are simple and the flow losses are considerably small, and the heat transfer coefficient is also relatively small. To test the regenerator experimentally, a regenerator test rig was manufactured. To verify the accuracy of the test rig, a woven screen regenerator was made and tested prior to the robust foil regenerator test. The friction factor correlation of the woven screen regenerator shows a good agreement with the published regenerator correlations. The robust foil regenerator tests were conducted under the oscillating flow condition with different Reynolds numbers. The flow losses were measured with dynamic pressure transducers and the friction coefficient was derived from measured pressure drop. The measured temperature difference over the regenerator was used to calculate the heat transfer coefficient and Nusselt number. The figure of merit with two methods of NPH/NTU ratio and j/f ratio was calculated to evaluate the suitability of the robust foil regenerator. The results show that the robust foil regenerator has considerably higher figure of merit and therefore, better performance than other types of regenerator.

42 ENGINEERING↗

MICRO-SCALE CFD MODELING OF OSCILLATING FLOW IN A REGENERATOR

Regenerator models used by designers are macro-scale models that do not explicitly consider interactions between the fluid and the solid matrix. Rather, the heat transfer coefficient and pressure drop are calculated using correlations for Nusselt number and friction factor. These correlations are typically based on steady flow data. The error associated with using steady flow correlations to characterize the oscillatory flow that is actually present in the regenerator is not well understood. Oscillating flow correlations based on experimental data do exist in the literature; however, these results are often conflicting. This paper uses a micro-scale computational fluid dynamic (CFD) model of a unit-cell of a regenerator matrix to determine the conditions for which oscillating flow affects friction factor. These conditions are compared to those found in typical pulse tube regenerators to determine whether oscillatory flow is of practical importance. CFD results clearly show a transition Valensi number beyond which oscillating flow significantly increases the friction factor. This transition Valensi number increases with Reynolds number. Most practical pulse tube regenerators will operate below this Valensi transition number and therefore this study suggests that the effect of flow oscillation on pressure drop can be neglected in macro-scale regenerator models.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Control methods for mitigating flow oscillations in a supercritical CO 2 recompression closed Brayton cycle

A dynamic model of a 10 MWe supercritical CO 2 (sCO 2 ) recompression closed Brayton power generation cycle is used to investigate control methods for mitigating oscillations in flow conditions and power demand load, especially as the load ramp rate is increased and the load setpoint is more closely tracked. The focus is on control of the main compressor inlet temperature (MCIT) since oscillations are prompted by the strong nonlinearities in sCO 2 fluid properties near the critical point and by changes in system inventory for efficient load management. In this study, the oscillatory behavior during load ramping is first shown and then two potential control solutions for substantially reducing oscillations are given: 1) the use of the main compressor inlet guide vanes (IGV) and 2) bypassing a portion of the sCO 2 around the cooler to maintain the MCIT. These control methods reduce the effect of cycle feedback from interactions between the MCIT and load. When implementing either control method, a load setpoint ramp of 7.5%/min was maintainable while achieving closer load setpoint tracking with limited oscillations. Finally, the impact of sensor noise on the control was examined since derivative action was used in the IGV and cooler sCO 2 bypass control. Finally, while some effect was evident, signal noise was not problematic to the control.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Resonant amplification of enzymatic chemical oscillations by oscillating flow

Using theory and simulation, we analyzed the resonant amplification of chemical oscillations that occur due to externally imposed oscillatory fluid flows. The chemical reactions are promoted by two enzyme-coated patches located sequentially on the inner surface of a pipe that transports the enclosed chemical solution. In the case of diffusion-limited systems, the period of oscillations in chemical reaction networks is determined by the rate of the chemical transport, which is diffusive in nature and, therefore, can be effectively accelerated by the imposed fluid flows. In this work, we first identify the natural frequencies of the chemical oscillations in the unperturbed reaction–diffusion system and, then, use the frequencies as a forcing input to drive the system to resonance. We demonstrate that flow-induced resonance can be used to amplify the amplitude of the chemical oscillations and to synchronize their frequency to the external forcing. In particular, we show that even 10% perturbations in the flow velocities can double the amplitude of the resulting chemical oscillations. Particularly, effective control can be achieved for the two-step chemical reactions where during the first half-period, the fluid flow accelerates the chemical flux toward the second catalytic patch, while during the second half-period, the flow amplifies the flux to the first patch. The results can provide design rules for regulating the dynamics of coupled reaction–diffusion processes and can facilitate the development of chemical reaction networks that act as chemical clocks.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The terminal velocity of a bubble in an oscillating flow.

A bubble in an acoustic field experiences a net 'Bjerknes' force from the nonlinear coupling of its radial oscillations with the oscillating buoyancy force. It is typically assumed that the bubble's net terminal velocity can be found by considering a spherical bubble with the imposed 'Bjerknes stresses'. We have analyzed the motion of such a bubble using a rigorous perturbation approach and found that one must include a term involving an effective mass flux through the bubble that arises from the time average of the second-order nonlinear terms in the kinematic boundary condition. The importance of this term is governed by the dimensionless parameter {alpha} = R{sup 2} {phi}/R{sup 2} {phi} {nu}.-{nu}, where R is the bubble radius, {phi} is the driving frequency, and {nu} is the liquid kinematic viscosity. If {alpha} is large, this term is unimportant, but if {alpha} is small, this term is the dominant factor in determining the terminal velocity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Oscillating flow and separation of species in rectangular channels

The mass transfer and separation of species in a tube using oscillatory flows are strongly affected by the fluid flow profiles in the tube. It has been well established that oscillatory motion in a one-dimensional flow configuration leads to a single tuning dimensionless frequency, where optimum separation may be effected. In this work, the effect on species separation by two-dimensional laminar flow arising in a rectangular cross section is studied and a surprising result is that a second tuning frequency may occur at lower dimensionless oscillation frequencies. The physics reveals that this new optimum disappears when the aspect ratio is either very large or close to unity. These observations are related to the flow profiles at different aspect ratios.

42 ENGINEERING↗

Linear response of stretch-affected premixed flames to flow oscillations

The linear response of 2D wedge-shaped premixed flames to harmonic velocity disturbances was studied, allowing for the influence of flame stretch manifested as variations in the local flame speed along the wrinkled flame front. Results obtained from analyzing the G-equation show that the flame response is mainly characterized by a Markstein number {sigma}{sub C}, which measures the curvature effect of the wrinkles, and a Strouhal number, St{sub f}, defined as the angular frequency of the disturbance normalized by the time taken for the disturbance to propagate the flame length. Flame stretch is found to become important when the disturbance frequency satisfies {sigma}{sub C}St{sub f}{sup 2}{proportional_to} O(1), i.e. St{sub f}{proportional_to} O({sigma}{sub C}{sup -1/2}). Specifically, for disturbance frequencies below this order, stretch effects are small and the flame responds as an unstretched one. When the disturbance frequencies are of this order, the transfer function, defined as the ratio of the normalized fluctuation of the heat release rate to that of the velocity, is contributed mostly from fluctuations of the flame surface area, which is now affected by stretch. Finally, as the disturbance frequency increases to St{sub f}{proportional_to} O({sigma}{sub C}{sup -1}), i.e. {sigma}{sub C}St{sub f}{proportional_to} O(1), the direct contribution from the stretch-affected flame speed fluctuation to the transfer function becomes comparable to that of the flame surface area. The present study phenomenologically explains the experimentally observed filtering effect in which the flame wrinkles developed at the flame base decay along the flame surface for large frequency disturbances as well as for thermal-diffusively stable and weakly unstable mixtures. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Theoretical and computational analysis of flow oscillations in S-CO{sub 2} natural circulation loop

The objective of this paper is to present a new model of natural-circulation loop cooled using fluids at slightly supercritical pressures. The modeling concept is based on the first principle time- and position-depended conservation equations, combined with analytic models of temperature and pressure-dependent fluid properties and a pressure control line connected to a pressurizer. Extensive parametric testing has been performed of the numerical solution method used in the analysis. The results of model predictions have been compared against other existing results, both theoretical and experimental. In particular, the model has been used in the analysis of a transient response of the SCO{sub 2} loop reported by Milone [1]. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Mean and Oscillating Plasma Flows and Turbulence Interactions across the L-H Confinement Transition

A complex interaction between turbulence driven ExB zonal flow oscillations, i.e., geodesic acoustic modes (GAMs), the turbulence, and mean equilibrium flows is observed during the low to high (L-H) plasma confinement mode transition in the ASDEX Upgrade tokamak. Below the L-H threshold at low densities a limit-cycle oscillation forms with competition between the turbulence level and the GAM flow shearing. At higher densities the cycle is diminished, while in the H mode the cycle duration becomes too short to sustain the GAM, which is replaced by large amplitude broadband flow perturbations. Initially GAM amplitude increases as the H-mode transition is approached, but is then suppressed in the H mode by enhanced mean flow shear.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Bio-Inspired adaptive damping in hydrokinetic energy harnessing using flow-induced oscillations

A hydrokinetic energy converter using Flow Induced Oscillations (FIOs) of a one-degree-of-freedom cylinder-oscillator, with nonlinear adaptive damping and linear spring stiffness, is introduced and studied experimentally. Comparison to a linear-oscillator in FIO shows that this new converter, with velocity-proportional damping coefficient, is more effective in galloping, where both flow and cylinder speeds are higher. It also impacts VIV, since the converter is no longer restricted by fixed damping, which results either in ceasing motion due to excessive damping, or in low harnessed energy due to insufficient damping. The impact is most profound in the VIV to galloping transition where adaptive damping prevents shutting down of hydrokinetic energy conversion. Damping-to-velocity rate, linear spring-stiffness, and flow-velocity are the experimental parameters with Reynolds number 30,000 ≤ Re ≤ 120,000. Here, experimental results for amplitude response, frequency response, energy harvesting, efficiency and instantaneous energy of the converter are presented and discussed. The main conclusions are: (1) The nonlinear, adaptive, velocity-proportional damping coefficient increases the harnessed power. (2) The operational range of flow velocities increases. (3) At lower flow speeds, the adaptive damping stabilizes the unstable oscillations typically occurring in this region. (4) At higher flow speeds, adaptive damping results in higher harnessed power than constant damping, thus, better emulating passively a corresponding, natural, active motion by fish. (5) Increase of 51%–95% in converted power by the nonlinear oscillator compared to linear oscillator has been measured. (6) The adaptive damping converter reaches a plateau in harnessed efficiency at high flow velocity (fully developed galloping).

13 HYDRO ENERGY↗

INVESTIGATION ON THE OSCILLATING GAS FLOW ALONG AN INERTANCE TUBE BY EXPERIMENTAL AND CFD METHODS

To investigate the oscillating gas flow along an inertance tube used in pulse tube coolers, a CFD model is set up for FLUENT and an experimental measuring cell is designed and optimized by CFD results. Some characteristics of oscillating flow are demonstrated and discussed. Then, the flow status along an inertance tube is measured by the optimized measuring cell. The experimental results validate the simulating results.

42 ENGINEERING↗

Hydrokinetic energy harvesting from slow currents using flow-induced oscillations

To harness marine hydrokinetic energy from slow flows, which constitute the majority of currents, tides, and rivers, new Passive Turbulence Control (PTC), consisting of large turbulence stimulators, is tested experimentally on circular cylinders on springs. Here, this study experimentally investigates the effect of PTC on the onset of Flow-Induced Oscillations (FIO) and particularly the relative onset of Vortex-Induced Vibrations (VIV) and galloping. Experiments are conducted in the Low Turbulence Free Surface Water Channel, University of Michigan. Fixed are: mass ratio m* = 1.48, aspect ratio l/D = 10.29, and total damping ratio ζ = 0.04. Parameters are: cylinder diameter D, spring stiffness K, PTC location and height, and flow speed U$\in$[0.36 m/s-1.45 m/s]. Placing the leading edge of PTC at 40–60° induces high amplitude FIO while placement at 10–20° suppresses FIO. As PTC height increases, VIV and galloping initiate earlier and exhibit higher amplitude with a steeper slope. Lower spring stiffness initiates VIV earlier by reducing the oscillator natural frequency in water. Even though large PTC maintained its effectiveness in initiating galloping early, it has no effect on the earlier initiation of VIV, which starts at a nearly fixed reduced velocity. Lower spring stiffness and large PTC enable power generation at low current speed (0.2 m/s).

16 TIDAL AND WAVE POWER↗

Turbulence structure in oscillating channel flow.

The structure of turbulence in an oscillating channel flow with near-sinusoidal fluctuations in bulk velocity is investigated. Phase-locked particle-image velocimetry data in the streamwise/wall-normal plane are interrogated to reveal the phase-modulation of two-point velocity correlation functions and of linear stochastic estimates of the velocity fluctuation field given the presence of a vortex in the logarithmic region of the boundary layer. The results reveal the periodic modulation of turbulence structure between large-scale residual disturbances, relaminarization during periods of strong acceleration, and a quasi-steady flow with evidence of hairpin vortices which is established late in the acceleration phase and persists through much of the deceleration period.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental and computational investigation of interactive flow induced oscillations of two tandem rough cylinders at 3×10 4 ≤Re≤1.2×10 5

The interactive flow induced oscillations (FIO) of two adjacent, elastically mounted, rigid, tandem, locally-rough cylinders in transverse flow direction are analyzed utilizing two-dimensional Unsteady Reynolds-Averaged Navier-Stokes (2-D URANS) equations and verified experimentally in the proximity-wake region. Three sets of experiments and simulations (K = 600N/m, ζ = 0.14; K = 600N/m, ζ = 0.26; K = 1,200N/m, ζ = 0.26; K is spring stiffness, ζ is damping ratio) of two tandem cylinders with turbulence stimulation are tested and simulated for Reynolds number in the range of 30,000 = Re ≤ 120,000. The reduced velocity range is U* = 2.48–14.22, the mass ratio is m* = 1.343, and the center-to-center in-flow spacing to diameter ratio is d/D = 2.57. The characteristics of amplitude response, frequency response, lift force, and interactive wake patterns are presented and discussed. The trends of the amplitude and frequency responses from numerical simulations are in good agreement with experimental results. The main conclusions of Reynolds number effect on interactive flow induced oscillations are: (1) Five significant flow patterns between two tandem locally-rough cylinders for different Reynolds numbers are observed through analyzing the complex but stable interactions between vortices and cylinders. (2) In the initial and upper VIV branches, the downstream cylinder's FIO is seriously interfered by the wake of the upstream cylinder. (3) The downstream cylinder is strongly impinged by the vortices shed from the upstream cylinder resulting in nearly 180O out-of-phase oscillations in transition from VIV to galloping and in-phase oscillations in galloping.

42 ENGINEERING↗

Experimental and numerical study of the shielding effect of two tandem rough cylinders in flow-induce oscillation

The shielding effect of the downstream cylinder in flow induced oscillation (FIO) of two cylinders arranged in tandem is studied experimentally and numerically at Reynolds number 30,000 to 120,000. Both cylinders are in one degree-of-freedom, transverse-oscillations, and have turbulence stimulation in the form of selective surface roughness to expand FIO beyond vortex-induced vibration (VIV) into galloping. Shielding of the downstream cylinder has a negative effect on harnessing hydrokinetic energy. Further, to study its effect and mechanics, selective cases are studied both numerically and experimentally and discussed to demonstrate the shielding effect on the downstream cylinder and understand its cause. The main conclusions are: (1) The shielding effect for the downstream cylinder shows a strong relation to the damping ratio. As the damping ratio increases, the shielding effect is mitigated. Additionally, the oscillation of the rear cylinder becomes stable and shows stable frequency. (2) In the VIV region, as the stiffness and natural frequency increase, the shielding effect decreases substantially. (3) In the VIV region, the vorticity of the vortices shedding from both the upper and the lower sides of the downstream cylinder does not accumulate enough due to the attraction by the vortices shed from the upstream cylinder, thus resulting in partial suppression of the oscillation on the downstream cylinder. (4) In the galloping region, the shielding effect for the downstream cylinder depends on whether the vorticity near the downstream cylinder is strengthened by the vortices generated by the shear layers of the upstream cylinder or weakened.

42 ENGINEERING↗

Modelling of a Flow-Induced Oscillation, Two-Cylinder, Hydrokinetic Energy Converter Based on Experimental Data

The VIVACE Converter consists of cylindrical oscillators in tandem subjected to transverse flow-induced oscillations (FIOs) that can be improved by varying the system parameters for a given in-flow velocity: damping, stiffness, and in-flow center-to-center spacing. Compared to a single isolated cylinder, tandem cylinders can harness more hydrokinetic energy due to synergy in FIO. Experimental and numerical methods have been utilized to analyze the FIO and energy harnessing of VIVACE. A surrogate-based model of two tandem cylinders is developed to predict the power harvesting and corresponding efficiency by introducing a backpropagation neural network. It is then utilized to reduce excessive experimental or computational testing. The effects of spacing, damping, and stiffness on harvested power and efficiency of the established prediction-model are analyzed. At each selected flow velocity, optimization results of power harvesting using the prediction-model are calculated under different combinations of damping and stiffness. The main conclusions are: (1) The surrogate model, built on extensive experimental data for tandem cylinders, can predict the cylinder oscillatory response accurately. (2) Increasing the damping ratio range from 0–0.24 to 0–0.30 is beneficial for improving power efficiency, but has no significant effect on power harvesting. (3) In galloping, a spacing ratio of 1.57 has the highest optimal harnessed power and efficiency compared with other spacing values. (4) Two tandem cylinders can harness 2.01–4.67 times the optimal power of an isolated cylinder. In addition, the former can achieve 1.46–4.01 times the efficiency of the latter. (5) The surrogate model is an efficient predictive tool defining parameters of the Converter for improved energy acquisition.