Search NASA⌕ Search

SEARCH · Search NASA

Results for “oscilloscopes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Exposure interlock for oscilloscope cameras

An exposure interlock has been developed for oscilloscope cameras which cuts off ambient light from the oscilloscope screen before the shutter of the camera is tripped. A flap is provided which may be selectively positioned to an open position which enables viewing of the oscilloscope screen and a closed position which cuts off the oscilloscope screen from view and simultaneously cuts off ambient light from the oscilloscope screen. A mechanical interlock is provided between the flap to be activated to its closed position before the camera shutter is tripped, thereby preventing overexposure of the film.

Spitzer, C. R.↗

Concept for a multifunctional oscilloscope probe

Multifunctional oscilloscope probe incorporates required electronic components so that any one of three desired functions /direct, demodulation, or low capitance/ can be switched into the oscilloscope. The probe obviates the need for the three seperate oscilloscope probes previously used in checking electronic equipment.

Stringer, E. J.↗

X-Y alphanumeric character generator for oscilloscopes

A method and apparatus is disclosed by which any general purpose external trigger laboratory oscilloscope can be utilized to display alphanumeric characters. Each character to be displayed is composed of a plurality of segments appearing at various segment positions in various segment rows to define a conventional matrix. In between character segments to be displayed, or when no display is desired, the trace is effectively blanked by a vertical clamping voltage so as to position the oscilloscope trace in an off-screen position. The clamping technique of the invention, i.e., biasing the oscilloscope trace to an off-screen position when no character segment is to be displayed; it eliminates the necessity of providing Z-axis modulation to effect blanking.

Lokerson, D. C.↗

Noise suppression by time exposure oscilloscope photography.

We describe a simple and inexpensive means of enhancing repetitive signals obscured by noise with roughly equal amplitude. The signal and noise are displayed on an oscilloscope, and we perform a time average over many traces by time exposure photography. If the oscilloscope triggering is synchronous with the signal, the result is a significant suppression of the offending noise.

Huchital, G. S.↗

Oscilloscope Data Push Program

This paper details the development of a Python program designed to automate the data acquisition and conversion for an oscilloscope for the purposes of a one-off/temporary data acquisition system for users that readily need data, and do not have the option of obtaining a Data Acquisition (DAQ) solution. Creating DAQ systems for analyzing a system requires expensive electronics and a dedicated team of engineers for support. Traditionally, manual data collection and processing are time consuming and prone to error. By automating these processes, the cost, efficiency and accuracy of data handling are improved upon. This project involves the creation of a program that interacts with the oscilloscope. During this interaction, there are various functions being performed such as the acquisition of waveform data via floating points, generating plots with the acquired wave points, and storing of floating points in a CSV file format for future reference and plotting purposes. While the initial aim of the project included continuous logging to a cloud database, this was deferred due to time constraints. The results portrayed an almost-instant rate of data collection with a buffer time, showcasing the potential for further integration and real-time data processing.

Osei-Tutu, Jason↗

Spherical fitting for oscilloscope film trace reading

This report describes a spherical fitting algorithm that can be used for estimating the oscilloscope film trace coordinates. This algorithm was adopted from a least square algebraic spherical fitting algorithm developed by the author earlier for photovoltaic velocimetry applications. Preliminary assessment suggests that the algorithm may be used for optimizing the coordinates manually digitized by the user, or may be used as an uncertainty estimator for the user’s film reading uncertainties.

97 MATHEMATICS AND COMPUTING↗

Oscilloscope Data Push Program

Data acquisition (DAQ) is a complex and costly process. Creating DAQ systems for analyzing a system requires expensive electronics and a dedicated team of engineers for support, posing a challenge for users who readily need data. This project is a proof of concept to create a temporary or one-off DAQ system using equipment commonly available to every team. We aim to automate the data acquisition process from the Rohde \& Schwarz RTO 1044 oscilloscope, convert the acquired binary data into floating point values, and store the results in a CSV file format. By developing a Python program to handle these tasks, we seek to reduce the manual effort involved in data collection, significantly increasing efficiency.

Osei-Tutu, Jason↗

Oscilloscope used as X-Y plotter or two-dimensional analyzer

Oscilloscope used as an X-Y plotter or two-dimensional analyzer tags each point with a yes or no, depending on a third parameter. The usual square-wave pulse is replaced on the scope by a single information-bearing dot which lengthens to a dash in response to a simultaneous event.

Hansen, D.↗

Alphanumeric character generator for oscilloscope

Compact portable alphanumeric display device can be used with any general-purpose externally-triggered oscilloscope without need for Z-axis modulation. Factors limiting size of display are: output line capacitance, read-only memory speed, and persistence of cathode-ray-tube.

Lockerson, D. C.↗

Transferring data oscilloscope to an IBM using an Apple II+

A set of PASCAL programs permitting the use of a laboratory microcomputer to facilitate and control the transfer of data from a digital oscilloscope (used with photomultipliers in experiments on soot formation in hydrocarbon combustion) to a mainframe computer and the subsequent mainframe processing of these data is presented. Advantages of this approach include the possibility of on-line computations, transmission flexibility, automatic transfer and selection, increased capacity and analysis options (such as smoothing, averaging, Fourier transformation, and high-quality plotting), and more rapid availability of results. The hardware and software are briefly characterized, the programs are discussed, and printouts of the listings are provided.

Miller, D. L.↗