Search NASA⌕ Search

SEARCH · Search NASA

Results for “overloading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Provably-Stable Overload Ride-Through Control for Grid-Forming Inverters Using System-Wide Lyapunov Function Analysis

A key challenge associated with a grid-forming (GFM) inverter based resource (IBR) is its behavior during severe grid disturbances: since a GFM inverter regulates voltage in the fast timescale instead of current or power, it may experience a transient overload of current, power and/or energy during a severe grid disturbance. While many promising control strategies for overload ride-through have been proposed over the past two decades, transient stability of the system during and after the transition to an overload ride-through control mode remains difficult to guarantee. In this work, a novel overload ride-through control strategy is proposed for a system of grid-forming inverters that takes both self-protection and system-wide transient stability into account. A proposed system-level supervisory control uses slow communication to pre-emptively assign a set of local ride through control parameters to individual GFM IBR, including a current-limiting virtual reactance, that guarantees that synchronism is still preserved for any set of anticipated grid disturbances. At the core of the supervisory control lies a Lyapunov-function-based routine capable of establishing a strong, albeit conservative, transient stability guarantee for the system. Here, the proposed overload ride-through control strategy is validated via numerical integration of a reduced-order model, as well as through detailed electromagnetic transient (EMT) simulation.

30 DIRECT ENERGY CONVERSION↗

Mitoferrin 2 deficiency prevents mitochondrial iron overload-induced endothelial injury and alleviates atherosclerosis

Endothelial dysfunction is an early step in the development of atherosclerotic cardiovascular disease. Iron overload can lead to excessive mitochondrial reactive oxygen species (mtROS) production, resulting in mitochondrial dysfunction and vascular endothelial cell (EC) damage. Mitoferrin 2 (Mfrn2) is an iron transporter in the inner mitochondrial membrane. This study aimed to assess whether Mfrn2 and mitochondrial iron overload were involved in atherosclerosis progression and to explore the potential mechanism. We observed significant upregulation of Mfrn2 in the arteries of high-fat diet (HFD)-fed Apolipoprotein E{sup −/-} (ApoE{sup −/-}) mice and in TNF-α-induced mouse aortic endothelial cells (MAECs). Mfrn2 gene silencing inhibited mitochondrial iron overload, stabilized mitochondrial membrane potential and improved mitochondrial function in TNF-α-induced MAECs. Vascular EC-specific knockdown of Mfrn2 in ApoE{sup −/-} mice markedly decreased atherosclerotic lesion formation and the levels of ICAM-1 in aortas and reduced monocyte infiltration into the vascular wall. Furthermore, TNF-α increased the binding of 14-3-3 epsilon (ε) and Mfrn2, preventing Mfrn2 degradation and leading to mitochondrial iron overload in ECs, while 14-3-3ε overexpression increased Mfrn2 stability by inhibiting its ubiquitination. Together, our results reveal that Mfrn2 deficiency attenuates endothelial dysfunction by decreasing iron levels within the mitochondria and mitochondrial dysfunction. These findings may provide new insights into preventive and therapeutic strategies against vascular endothelial dysfunction in atherosclerotic disease.

60 APPLIED LIFE SCIENCES↗

Stokes-dependent droplet collection efficiency on a NACA 0012 airfoil from droplet-informed simulations with statistical overloading

Accurate modelling of ice accretion on aircraft wings requires analysing droplet impingement on the surface to optimize the design of ice-protection systems. We perform Euler–Lagrange simulations of a droplet-laden flow impinging on a NACA 0012 airfoil. Our study includes water droplets with eight discrete sizes ranging from 1 to 160 microns. We vary the free-stream velocity of the incoming airflow in the range 60 ≤ U ≤ 240 m s −1 and the chord length of the airfoil in the range 0.5 ≤ c ≤ 2 m. Due to the dilute nature of supercooled clouds, one-way coupling is used in the simulations. The effects of droplet breakup and collision are also neglected. To reduce the computational cost, we employ statistical overloading of droplets, allowing us to simulate millions of impinging droplets in a time span on the order of milliseconds. Our results show that the droplet collection efficiency, which measures the likelihood of droplet impingement on the airfoil surface, increases with droplet size and free-stream velocity but decreases with airfoil size. We demonstrate that collection efficiency, impingement velocity and impingement angle are primarily dictated by a single non-dimensional parameter, the droplet Stokes number. We also identify a critical stagnation-streamline Stokes number below which impingements do not occur and use it to estimate the minimum droplet size for impingement. In addition, we observe droplet behaviour to become Stokes number independent at large values of the Stokes number. This article is part of the theme issue ‘Heat and mass transfer in frost and ice’.

Science & Technology - Other Topics↗

First comprehensive identification of cardiac proteins with putative increased O-GlcNAc levels during pressure overload hypertrophy

Protein posttranslational modifications (PTMs) by O-GlcNAc globally rise during pressure-overload hypertrophy (POH). However, a major knowledge gap exists on the specific proteins undergoing changes in O-GlcNAc levels during POH primarily because this PTM is low abundance and easily lost during standard mass spectrometry (MS) conditions used for protein identification. Methodologies have emerged to enrich samples for O-GlcNAcylated proteins prior to MS analysis. Accordingly, our goal was to identify the specific proteins undergoing changes in O-GlcNAc levels during POH. We used C57/Bl6 mice subjected to Sham or transverse aortic constriction (TAC) to create POH. From the hearts, we labelled the O-GlcNAc moiety with tetramethylrhodamine azide (TAMRA) before sample enrichment by TAMRA immunoprecipitation (IP). We used LC-MS/MS to identify and quantify the captured putative O-GlcNAcylated proteins. We identified a total of 700 putative O-GlcNAcylated proteins in Sham and POH. Two hundred thirty-three of these proteins had significantly increased enrichment in POH over Sham suggesting higher O-GlcNAc levels whereas no proteins were significantly decreased by POH. We examined two MS identified metabolic enzymes, CPT1B and the PDH complex, to validate by immunoprecipitation. We corroborated increased O-GlcNAc levels during POH for CPT1B and the PDH complex. Enzyme activity assays suggests higher O-GlcNAcylation increases CPT1 activity and decreases PDH activity during POH. In summary, we generated the first comprehensive list of proteins with putative changes in O-GlcNAc levels during POH. Our results demonstrate the large number of potential proteins and cellular processes affected by O-GlcNAc and serve as a guide for testing specific O-GlcNAc-regulated mechanisms during POH.

59 BASIC BIOLOGICAL SCIENCES↗

Thermal Overloading Risk Mitigation With a Semi-Analytical Probabilistic Model on Branch Current

A semi-analytical formulation is presented in this paper for the probability computation of branch current in multiphase systems. The developed formula is derived based on the linear power flow model in rectangular coordinates. The system uncertainty injections can be renewable energy resources or loads and are modeled using a Gaussian mixture model (GMM). The developed formula can be used to compute the line current violation probability as well as integrate into optimal power flow problem as chance-constraint relaxation. Here, the proposed formula is first compared with the Matlab embedded numerical integration function to show its performance. Besides, the semi-analytical formula is validated and compared with the Monte Carlo simulation method using the IEEE 123-bus system, EPRI Ckt5, and Ckt7 systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transient creep‐fatigue crack growth in creep‐brittle materials: Application to Alloy 718

Abstract This study presents incremental finite element computations of creep‐fatigue crack growth in Alloy 718 at in air. Alloy 718 is representative of creep‐brittle materials, in which viscoplastic deformation is restricted near the tip of a growing crack. The computations predict crack growth using a unique combination of an irreversible cohesive zone formulation and a strain gradient viscoplastic material model based on the Kocks–Mecking formulation. Cohesive zone damage parameters are estimated using sustained loading and constant‐amplitude cyclic loading experiments. Computations of crack extension under three different waveforms containing overloads all predict post‐overload retardation. The amount of retardation depends strongly on the overload ratio, consistent with experiments in the literature using similar waveforms. Analysis of the crack‐tip fields demonstrates retardation is associated with unloading in the highly deformed material near the advancing crack tip. Dynamic recovery and geometrically necessary dislocations are shown to significantly influence post‐overload crack extension.

36 MATERIALS SCIENCE↗

Distribution Grid Impact Study in Highland Park, Michigan: Understanding Rooftop Solar, Behind-the-Meter Energy Storage, Electric Vehicle Charging, and Building Electrification [Slides]

Through the Communities LEAP (Local Energy Action Program) Pilot, the National Renewable Energy Laboratory (NREL) engaged the Highland Park Stakeholder Coalition to scope four technical assistance work areas to address their energy needs and goals. This slide deck addresses the highlighted tasks under work area "B" related to policy analysis, due diligence, and case studies for removing barriers and providing best practices for local clean energy development. Highland Park community members face frequent, long-duration power interruptions due largely to the aging distribution system serving the area and the legacy design standards used in its construction. While degrading physical infrastructure such as poles, crossarms, and transformers can result in this substandard reliability, another notable characteristic of this legacy system is the lower, 4.8 kV, voltage class. This is a legacy construction standard which many utilities, DTE included, are phasing out in favor of higher, 15 or 25 kV, voltage classes instead. The existing 4.8 kV distribution system serving Highland Park may limit significant adoptions of clean-energy technologies like high percentages of building electrification or electric vehicle adoption. The following analysis seeks to quantify these limitations under a variety of clean-energy technology adoption scenarios. It compares the overall system risks of the present system to those of a hypothetical, upgraded 13.2 kV system, using NREL-developed risk metrics and offers upgrade cost considerations. The legacy 4.8 kV voltage class serving Highland park is not, as we have modeled it, a major limitation to the widespread adoption of cost-optimal rooftop solar and/or behind-the-meter energy storage. Within our modeling framework, these technologies namely impact secondary, low-voltage assets, which may be remedied without the need for a system-wide upgrade to a 13.2 kV voltage class. Our model of the current 4.8kV system indicates it is not capable of supporting community-wide electrification efforts. Widespread building electrification, and the resulting large increase in wintertime load, dramatically increases the prevalence of voltage violations and thermal overloading on the current 4.8 kV distribution system. These impacts illustrate the need for system-wide upgrades to a 13.2 kV voltage class to accommodate these technologies. Low to Moderate DER adoption does not adversely impact the grid but does improve undervoltage and asset overloading issues. However, these benefits are insufficient to defer grid upgrades. Higher DER penetration is shown to increase overvoltage and asset overloading in future electrification scenarios.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Overcoming the Damping–Elasticity Paradox via 3D‐Printed NiTiSn Nanocomposite

Abstract Developing high damping alloys (HDAs) with large elastic strain has attracted growing attention due to the increasing demand for energy absorption with overload reliability and reusability. However, damping capacity inherently conflicts with elasticity, because the former requires a liable movement of crystal defects while the latter opposite. To deal with the damping‐elasticity paradox, the advantage of pseudobinary eutectic reaction and rapid cooling of laser powder bed fusion is taken to fabricate a bulk NiTiSn nanocomposite with a two‐level hierarchical structure. The first‐level architecture is composed of martensitic NiTi nanolamellae and reinforced Ti 3 Sn nanolamellae. In addition to lattice strain matching and lamellar boundary strengthening, a novel mechanism of martensite reorientation mediated by reversible stress‐induced detwinning‐twinning is activated to generate large elastic strain. A high density of nanotwins and nanodomains within NiTi nanolamellae constitute the second‐level architecture, which provides pronounced internal friction for high damping capacity. As a result, our NiTiSn nanocomposite exhibits a record‐high integration of damping capacity (tanδ > 0.10) and elastic strain (exceeding 4.5%), as well as superb stability under cyclic overload. This research not only represents a major breakthrough in achieving HDAs with outstanding damping and elastic strain but also offers a novel paradigm for high‐performance functional and structural materials.

Chemistry↗

Dynamic hosting capacity analysis for distributed photovoltaic resources—Framework and case study

Distributed photovoltaic systems can cause adverse distribution system impacts, including voltage violations at customer locations and thermal overload of lines, transformers, and other equipment resulting from high current. The installed capacity at which violations first occur and above which would require system upgrades is called the hosting capacity. Current static methods for determining hosting capacity tend to either consider infrequent worst-case snapshots in time and/or capture coarse time and spatial resolution. Because the duration of violations cannot be captured with these traditional methods, the metric thresholds used in these studies conservatively use the strictest constraints given in operating standards, even though both worse voltage performance and higher overloads may be temporarily acceptable. However, assessing the full details requires accurately capturing time-dependence, voltage-regulating equipment operations, and performance of advanced controls-based mitigation techniques. In this paper, we propose a dynamic distributed photovoltaic hosting capacity methodology to address these issues by conducting power flow analysis for a full year. A key contribution is the formulation of time aware metrics to take these annual results and identify the hosting capacity. Through a case study, we show that this approach can more fully capture grid impacts of distributed photovoltaic than traditional methods and the dynamic hosting capacity was 60%–200% higher than the static hosting capacity in this case study.

14 SOLAR ENERGY↗

Distribution of blackouts in the power grid and the Motter and Lai model

Carreras, Dobson, and colleagues have studied empirical data on the sizes of the blackouts in real grids and modeled them with computer simulations using the direct current approximation. They have found that the resulting blackout sizes are distributed as a power law and suggested that this is because the grids are driven to the self-organized critical state. In contrast, more recent studies found that the distribution of cascades is bimodal resulting in either a very small blackout or a very large blackout, engulfing a finite fraction of the system. Here we reconcile the two approaches and investigate how the distribution of the blackouts changes with model parameters, including the tolerance criteria and the dynamic rules of failure of the overloaded lines during the cascade. Finally, we study the same problem for the Motter and Lai model and find similar results, suggesting that the physical laws of flow on the network are not as important as network topology, overload conditions, and dynamic rules of failure.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Unified Model of Current-Limiting Grid-Forming Inverters for Large-Signal Analysis

Grid-forming (GFM) inverters can hardly withstand any overloading. As such, GFM inverters need a current limiter in their control system to avoid hardware damage during overloading or grid disturbances. When the current limiter is engaged for inverter protection, however, it dynamically changes the inverter output impedance, which can significantly affect the system behavior against large disturbances. For example, when the current limiter curtails the output power, the primary controller of the GFM inverter-which generates the voltage and angle reference-is prone to losing synchronization with the grid. This can cause large-signal instability in the network. This paper presents a unified GFM current-limiter model to gain a deeper understanding of the impact of the GFM inverter current limiting on large-signal instability and other system behaviors. The unified model captures several well-known current limiters for GFM inverters, and it reveals their large-signal equivalence characterized by the limiter angle. We use the unified model to present in-depth insights into the driving forces that cause large-signal instability in GFM inverter-driven grids. Further, this paper illustrates that the unified model can be used as a tool for assessing the system-level impacts of various GFM current-limiter designs during grid disturbances. Using numerical, analytical, electromagnetic transient models, and a hardware setup, the validity of the unified model is evaluated.

24 POWER TRANSMISSION AND DISTRIBUTION↗

PMK 1000 cone-socket ventilator fittings force testing to ISO 5356-1:2015 Standard

This memo summarizes the results of verification tests on a cone-socket fitting to the ISO 5356-1:2015 standard, annexes B and F. The components were found to meet requirements holding 50N tensile force and more than 35 N-cm of torque for 10 seconds without separating at 35°C with a fresh socket. Humidity control was unavailable; consequently, humidity was significantly lower than the values in the ISO standard. Several repeat tests of the fitting with force, torque, and time excursions give us confidence that the fittings perform suitably to the ISO standard. Force overload tests suggest that the samples will disengage under tension at around 69 N, while torque overload tests under a force of 50 N will fail at 79 N-cm of torque. If repeated tests are performed on the same component, the socket can deform and lead to the connection failing the standard requirements. However, such failures only occur with repeated testing, and the gripping of such units can be modified so that they pass the standard. This observation demonstrates that socket gripping is responsible for those failures and would not be a problem in application.

42 ENGINEERING↗

Insulating Nanofluids and Solids to Upgrade our Large Aging Transformer Equipment (Advanced Research Projects Agency – Energy Research Final Report)

This project developed a highly promising, minimally invasive pathway for transformers with up to double the thermal life that is achieved today. Thermal life is important because it is occasionally necessary to overload transformers in service and this overload raises the internal temperature, accelerating aging2. A seminal initial finding in the research was that a likely achievable increase in the thermal conductivity of the transformer paper could double the thermal life. Oil-impregnated paper is used to wrap the electrical conductors in a transformer to provide a good balance of electrical insulation and thermal conductivity. The novel approach to increase the thermal conductivity was to add micrometer boron nitride particles to the paper during manufacturing. This is encouraging because it provides benefits with minimal impact on the manufacturing processes of the paper or of a transformer.

24 POWER TRANSMISSION AND DISTRIBUTION↗