True Breakdown Voltage and Overvoltage Margin of GaN Power HEMTs in Hard Switching

This work studies the dynamic breakdown voltage (BV) and overvoltage margin of a 650-V-rated commercial GaN power HEMT in hard switching. The dynamic BV measured in the hard switching circuits is over 1.4 kV, being 450 V higher than the static BV measured in the quasi-static I-V sweep. The device can survive at least 1 million hard-switching overvoltage pulses with 1.33 kV peak overvoltage (~95% dynamic BV). Recoverable device parametric shifts are observed after the 1-million pulses, featuring small reductions in threshold voltage and on-resistance. These shifts are different from the ones after the hard-switching pulses without overvoltage and are attributable to the trapping of the holes produced in impact ionization. Furthermore, these results suggest that the BV and overvoltage margin of GaN HEMTs in practical power switching can be significantly underestimated using the static BV. Index Terms— GaN, HEMT, power electronics, hard switching, breakdown voltage, overvoltage, ruggedness, reliability.

42 ENGINEERING↗

A Fast-Response High-Accuracy Overvoltage Protection Circuit for Soft-Switching Current-Source Converters

Although voltage-source converters (VSCs) have been a focus of research for decades and are widely applied in numerous applications, they face great challenges in short-circuit failures, high dv/dt and electromagnetic interference (EMI), especially using wide bandgap devices. Instead, current-source converters (CSCs) are attracting increasing attention in recent years owing to their friendliness to short-circuit faults, improved EMI, etc. For CSCs, overvoltage is the most catastrophic failure since the semiconductor devices can hardly withstand an overvoltage for a short pulse. In this paper, a fast-response high-accuracy overvoltage protection (OVP) circuit is proposed to protect CSCs from overvoltage damage. It also features a small form factor, good noise-immunity, friendly retrofit capability, and no need for active switches. In this paper, the operating principle and design guideline of the proposed OVP circuit is introduced. Its effectiveness is validated in soft-switching solid-state transformer (S4T) at 500 V. In experiments, the voltage detection error of less than 5% and a propagation delay of fewer than 400 ns have been achieved.

30 DIRECT ENERGY CONVERSION↗

A Flexible and Secure Evaluation Platform for Overvoltage Protection in Power Electronics Systems

This paper summarizes the fault mechanisms specifically for the overvoltage protection schemes in power electronic converters and the resulted power electronics enabled systems. A flexible and secure evaluation platform for overvoltage protection, has also been presented based on this conceptual mechanism. The proposed platform aims at testing the protection performance of distinctive overvoltage protection schemes. It would be applied to verify the effectiveness, identify potential strengths and weaknesses, and obtain the most critical protection response time to provide sufficient engineering insights for the designer. The operation principle and detailed design guideline have been presented first. The comprehensive component stress has been analyzed. An intensive set of LTSpice simulations have been conducted to show the validity of the proposed assessment approach.

Zheng, Sheng↗

Overvoltage Prevention and Curtailment Reduction Using Adaptive Droop-Based Supplementary Control in Smart Inverters

Recent developments in the renewable energy sector have seen an unprecedented growth in residential photovoltaic (PV) installations. However, high PV penetration levels often lead to overvoltage problems in low-voltage (LV) distribution feeders. Smart inverter control such as active power curtailment (APC)-based overvoltage control can be implemented to overcome these challenges. The APC technique utilizes a constant droop-based approach which curtails power rigidly, which can lead to significant energy curtailment in the LV distribution feeders. In this paper, different variations of the APC technique with linear, quadratic, and exponential droops have been analyzed from the point-of-view of energy curtailment for a LV distribution network in North America. Further, a combinatorial approach using various droop-based APC methods in conjunction with adaptive dynamic programming (ADP) as a supplementary control scheme has also been proposed. The proposed approach minimizes energy curtailment in the LV distribution network by adjusting the droop gains. Simulation results depict that ADP in conjunction with exponential droop reduces the energy curtailment to approximately 50% compared to using the standard linear droop.

42 ENGINEERING↗

Surge-Energy and Overvoltage Ruggedness of P-Gate GaN HEMTs

An essential ruggedness of power devices is the capability of safely withstanding the surge energy. The surge ruggedness of the GaN high-electron-mobility transistor (HEMT), a power transistor with no or minimal avalanche capability, has not been fully understood. This article unveils the comprehensive physics associated with the surge-energy withstand process and the failure mechanisms of p-gate GaN HEMTs. Two commercial p-gate GaN HEMTs with Ohmic- and Schottky-type gate contacts are studied. Two circuits are developed to study the device surge ruggedness: an unclamped inductive switching circuit is first used to identify the withstand dynamics and failure mechanisms, and a clamped inductive switching circuit with a controllable parasitic inductance is then designed to mimic the surge energy in converter-like switching events. The p-gate GaN HEMT is found to withstand the surge energy through a resonant energy transfer between the device capacitance and the load/parasitic inductance rather than a resistive energy dissipation as occurred in the avalanche. If the device resonant voltage goes below zero, the device reversely turns on and the inductor is discharged. The device failure occurs at the transient of peak resonant voltage and is limited by the device overvoltage capability rather than the surge energy, dV/dt , or overvoltage duration. Almost no energy is dissipated in the resonant withstand process and the device failure is dominated by an electric field rather than a thermal runaway. Furthermore, these results provide critical understandings on the ruggedness of GaN HEMTs and important references for their qualifications and applications.

42 ENGINEERING↗

Hollow plasma structure during the breakdown phase of nanosecond pulsed pin–pin discharges generated with overvoltage

Atmospheric pressure nanosecond repetitive pulsed discharges are of interest for applications in combustion, material processing, plasma medicine and gas treatment. Here, the observation of a hollow structure at the ignition stage of such discharge in a pin–pin geometry is reported. Plasma images show that the phenomenon occurs in a variety of gases (helium, humid helium, argon and air) suggesting that it is in first approximation non-species specific. The phenomenon is investigated in detail in pure helium discharges for peak applied voltages between 3 and 6 kV and 200 ns voltage pulse duration by performing time-resolved optical emission spectroscopy measurements of electron density, gas temperature and electric field. All the measurements were performed at the mid-gap during the early stages of the discharge, near the breakdown. The transition from a homogeneous filament to a hollow structure occurs between 4 and 5 kV in helium. Electron density measurements by Stark broadening of the He I line at 492.2 nm show no significant difference in electron densities for the applied voltage between 3 and 6 kV. In all cases, a maximum electron density of about 3.5 × 10 21 m –3 was found. Electric field measurements performed by Stark polarization spectroscopy of the He I transition at 492.2 nm and of its forbidden counterpart show electric field strengths higher than the DC breakdown field of helium at atmospheric pressure consistent with the generation of the discharges with overvoltage. Moreover, a correlation between electric field values and the appearance of the hollow structure is observed and, remarkably, the phenomenon is not sensitive to the pre-ionization level (memory effect). Possible mechanisms for the phenomenon are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Alternative 3V0 Development for Ground Fault Overvoltage Protection with DERs/Renewables Interconnection (Final Report)

The ground fault overvoltage (GFOV) and the required traditional 3V0 installation has become a concerned issue for renewable/DER integration. Based on the alternative 3V0 methodology proposed by the PI and the feasibility study awarded by DOE SBIR/STIR project (Award No. DE-SC0018888), APS and RPI investigated development of a low-cost alternative 3V0 product based on the surge arrester current monitoring. The alternative 3V0 feasibility study completed by APS and RPI has verified that the alternative 3V0 is an effective solution (possibly the only one) under various circuit conditions and is competitive to traditional 3V0 methods.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Switching Modes for Reduction of Peak Voltage Transients in GaN-Based Three Level ANPC Inverter

The switching pole voltage can transition between P,0, and N states in a three-level active neutral point clamped (ANPC) inverter. State transitions between 0-P and 0-N can be realized with different switching modes. Three switching modes- Short 1 , Short 2 , and Full are studied considering the effect of capacitive current paths. The role of clamping and inner switch on/off conditions is determined using simplified equivalent circuit models. Short 2 with clamping switch off is beneficial for turn-on overvoltage suppression but results in high turn-off overvoltage. Full mode with a parallel current sharing path is effective for turn-off overvoltage suppression but leads to high turn-on overvoltage. Hence, a Modified Full mode is proposed to achieve the simultaneous objective of overvoltage suppression at both turn-on and turn-off transient during high load currents. This benefits 3L ANPC operation at a low power factor with a high load current at fundamental voltage zero crossing points. Here, a 650V GaN-based three-level ANPC inverter prototype is designed and used to evaluate the switching modes and overvoltage suppression strategies through double pulse tests and continuous operation.

42 ENGINEERING↗

Fairness-Aware Distributed Energy Coordination for Voltage Regulation in Power Distribution Systems

The accelerating deployment of solar photovoltaics into low-voltage distribution networks can cause reverse power flow and overvoltage problems. However, if coordinated properly, the real and reactive power flexibility of these resources enables distribution operators to manage their networks more efficiently. Existing literature is rich in droop-based control (Volt-Watt and Volt-VAr) and optimization-based distributed energy coordination for four-quadrant control of photovoltaics to prevent overvoltage issues. While optimal coordination can effectively mitigate overvoltage, it tends to treat resources at sensitive parts of the grid unfairly. Here, to address this concern, we propose a distributed optimal power flow formulation that incorporates fairness in curtailing photovoltaic generation and utilizes the reactive power capability of smart inverters. The proposed distributed formulation allows for scalable resource aggregation that can be leveraged to achieve fairness within a certain segment of the grid and/or fairness across the entire network. Fair curtailment of photovoltaic systems is demonstrated with aggregation at each of two layers in a distribution network: 1) area-level fairness and 2) feeder-level fairness. To explore the trade-off between fairness and optimal utilization, the fairness-aware control actions are compared against the performance of a centralized controller that aims to maximize the aggregate PV generation without incorporating fairness. Simulation results show that introducing area-level fairness increased curtailment by 0.0101 percentage points and feeder-level fairness increased curtailment by 0.0458 percentage points compared to a fairness-agnostic control.

Poudel, Shiva↗

Mitigating Data Center Impact on Grid Stability: A Coordinated Control Strategy Using Verrus StabiliGrid Architecture

Large data centers, which now represent a significant and growing share of the total U.S. grid load, can inadvertently destabilize the electrical grid when they disconnect simultaneously during brief voltage disturbances. The July 10, 2024, Eastern Interconnection incident, in which a sub-100-millisecond transmission fault triggered the cascading loss of approximately 1,500 MW of data center load, illustrates this vulnerability. While commercial battery energy storage systems (BESS) deployed in data centers provide device-level fault ride-through per IEEE 1547, they lack coordination with facility protection logic and uninterruptible power supplies (UPS), limiting their effectiveness as grid-stabilizing assets. This report presents the Verrus StabiliGrid architecture, a coordinated control framework that integrates BESS, UPS, and point-of-interconnection (POI) protection settings to enable data centers to ride through both undervoltage and overvoltage grid contingencies without disconnecting. The four-step strategy encompasses: (1) high-resolution power quality monitoring to detect the grid state during events such as undervoltage, overvoltage, underfrequency, and overfrequency; (2) POI protection settings that allow for extended ride-through and grid-connected operation during grid contingencies; (3) grid state-driven autonomous dispatch of assets to improve grid resilience by reducing power draw during undervoltage or absorbing more power during overvoltage events; and (4) coordinated post-recovery dispatch of data center assets to restore firm load to pre-contingency levels. Validated through controller-hardware-in-the-loop (C-HIL) simulations at the National Laboratory of the Rockies, results show grid import restoration to pre-fault levels within 100 milliseconds of voltage recovery. This work advances the ability of data centers to transition from passive, disturbance-sensitive loads to active participants in grid stability, a capability increasingly required by emerging NERC and ERCOT regulatory frameworks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Fairness-based Distributed Energy Coordination for Voltage Regulation in Distribution Systems

The rapid adoption of photovoltaic (PV) systems combined with falling prices of energy storage is paving the way for a future in which customers could locally supply their energy needs and export surplus power to the grid. However, reverse power flow from multiple sites in a network can cause overvoltage that decreases system reliability and the utilization level of PV system. In this paper, we present a two-stage approach to solve the energy coordination problem in distribution networks. In the first stage, a household with PV and energy storage is optimized to allow customers to adopt different control strategies such as load following and tariff arbitrage. We show that such customer-led control strategies can cause reverse power flows during peak PV generation periods, thus resulting in overvoltage. In such cases, the second stage of the proposed approach is called upon to solve a fairness-based energy coordination problem that can maintain voltages within limits while maximizing the PV generation while fairly distributing the actions among all the PV systems. As a result, each of the resources in the network has equal opportunity to export power and shares the responsibility of voltage regulation. Simulation studies have been carried out on the IEEE 13-bus test feeder to verify the effectiveness of the proposed approach.

Distributed energy resources, fairness, overvoltag↗

Enabling Fairness in Distributed PV Curtailment for Voltage Regulation: A Comparative Analysis

The growing adoption of photovoltaic systems in power distribution networks has yielded numerous advantages, but it has also introduced challenges, particularly in managing overvoltage issues. Uncoordinated photovoltaic integration can lead to voltage rise beyond acceptable levels. Curtailing active power is an effective method for addressing overvoltage issues in power distribution systems. Nevertheless, it is essential to distribute the curtailment fairly among the resources to maintain fairness and achieve a well-balanced utilization of renewable energy. This paper presents a comparative study of different fairness schemes for active power curtailment in photovoltaic integration systems. Three different curtailment methods are selected for demonstration: i) proportional, ii) egalitarian, and iii) financial. The study involves evaluating the curtailment schemes based on their ability to distribute the curtailed power among the photovoltaic systems in a justifiable manner, focusing on their formulation and distributed solution. A detailed performance comparison is carried out to highlight the cost of catering for fairness schemes in photovoltaic curtailment using relevant metrics, where simulations are carried out using a modified IEEE 123-bus test case.

Mukherjee, Monish↗

A Novel Model of Thyristor in Reverse Recovery Process for Current Interruption Test of HVDC Circuit Breakers

The high voltage thyristor is widely used in high voltage DC (HVDC) grids due to its large current capability. Recently, the high voltage thyristor is implemented to produce a high current in the HVDC circuit breaker (CB) testing process. Unfortunately, the reverse recovery process (RRP) of a thyristor could induce significant turn-off overvoltage and power losses, jeopardizing the safety of the devices. The existing models of a thyristor cannot describe such hard-switching transient accurately. Therefore, this paper divides this process into four stages based on the physical mechanism and proposes a novel cosine exponential (CE), simulating the voltage and current of the thyristor with analytical equations, which are derived from the equivalent circuit. Moreover, the extraction procedure of the proposed model is illustrated in this paper. Finally, we develop an HVDC CB test platform to validate the proposed model. Experimental results show that the proposed CE model can accurately predict the overvoltage with a relative error of less than 8% at various current varying rates.

Dongye, Zhonghao↗