Search NASA⌕ Search

SEARCH · Search NASA

Results for “oxygen monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Excerpt from Oxygen Monitor Clean Testing Report Performed in 2010

The Rosemount X-STREAM Series X2GP is a paramagnetic oxygen analyzer with a 0-25% oxygen measurement range. It claims a drift less than 2% of span (0.10% volume oxygen) per week, and a response time of less than 5 seconds (for the analyzer to report 90% of a step change). Our test equipment was set-up such that the same gas was running through each oxygen analyzer at the same time. This allowed Calibration Error, Calibration Drift, and Loss of Power Testing to be run on all monitors at the same time, eliminating any variability between the analyzers from tolerances in the gas cylinder, ambient temperature, ambient pressure, test duration, etc. An APTech pressure regulator was placed on the gas cylinder manifold and a 23 psia Paroscientific pressure transducer measured the regulator’s outlet pressure. This did not give the inlet pressure on any one analyzer but outlet pressure from the manifold before the stream was split. The APTech pressure regulator was used to keep operating conditions consistent. A DWYER rotameter was installed on each oxygen monitor’s outlet piping. With the exception of Variation of Flow Rate Testing, the rotameter was left fully open for all testing. The flow rate through each oxygen monitor was controlled by a Swagelok needle valve that was installed on each analyzer’s inlet piping. Additionally, a filter was installed in the each monitor’s inlet piping to keep particles from the measurement cells and a Swagelok ball valve was installed on each monitor’s outlet piping to isolate each monitor between tests. No pumps were installed. Each of the cylinders used was at a pressure greater than ambient room barometric pressure. This pressure differential was used to move gas through the testing equipment. The flow rate through each analyzer was controlled by the Swagelok needle valve installed on each analyzer’s inlet piping. Finally, for all tests, a Paroscientific Digiquartz Barometer was used to measure ambient room barometric pressure and a Fluke Thermo-hygrometer was used to measure ambient room temperature.

47 OTHER INSTRUMENTATION↗

Revealing the coupled oxygen and hypochlorite chemistry in saltwater batteries through operando pH and oxygen monitoring

Saltwater batteries (SWBs) that utilize Na⁺ ions from seawater have emerged as promising candidates for low-cost and sustainable grid-scale energy storage. To date, the cathode reaction mechanism of SWBs has been predominantly described by oxygen evolution and reduction reactions (OER/ORR). However, this assumption is valid only under idealized ocean-like conditions with constant pH and continuous oxygen replenishment. In practical systems, SWBs operate in finite volumes of saltwater, where saltwater composition dynamically evolves during cycling. Here, in this work, we systematically investigate the cathode reaction mechanisms of SWBs under finite saltwater conditions using galvanostatic cycling combined with electrochemical diagnostics and operando monitoring of dissolved oxygen and pH. Our results reveal that the cathode chemistry during SWB operation is considerably more complex than previously assumed. In addition to OER and ORR, hypochlorite formation and consumption reactions, along with pH-dependent switching of dominant reaction pathways, play critical roles. We further identify the sequence and relative contributions of these reactions throughout charge–discharge cycling. These findings provide a comprehensive and mechanistically grounded understanding of SWB cathode processes under relatively realistic cell design and operation condition. The insights presented here establish a new framework for interpreting SWB electrochemistry and offer directions for future strategies aimed at improving performance, stability, and practical viability.

Hypochlorite redox reaction↗

An underground, wireless, open-source, low-cost system for monitoring oxygen, temperature, and soil moisture

Abstract. The use of wireless sensor networks to measure soil parameters eliminates the need to remove sensors for field operations, such as tillage, thus allowing long-term measurements without multiple disturbances to soil structure. Wireless sensors also reduce above-ground cables and the risk of undesired equipment damage and potential data loss. However, implementing wireless sensor networks in field studies usually requires advanced and costly engineering knowledge. This study presents a new underground, wireless, open-source, low-cost system for monitoring soil oxygen, temperature, and soil moisture. The process of system design, assembly, programming, deployment, and power management is presented. The system can be left underground for several years without the need to change the battery. Emphasis was given on modularity so that it can be easily duplicated or changed if needed and deployed without previous engineering knowledge. Data from this type of system have a wide range of applications, including precision agriculture and high-resolution modelling.

54 ENVIRONMENTAL SCIENCES↗

A review of zirconia oxygen, NO x , and mixed potential gas sensors – History and current trends

Zirconia-based electrochemical sensors have revolutionized oxygen monitoring and combustion control. Here, these robust, solid-state devices are found in virtually every internal combustion engine today providing feedback information for tight air to fuel ratio control thus minimizing unwanted emissions and improving engine efficiency. Variations on the sensor design and operational mode enable the measurement of nitrogen oxides to part per million levels, providing control information for exhaust after-treatment systems. Emerging designs include the development of "gas analyzers on a chip" capable of monitoring oxygen, carbon monoxide, nitrogen oxides, ammonia and hydrocarbons.

47 OTHER INSTRUMENTATION↗

Single Crystal Optical Fiber and Perovskite Oxide Sensing Materials for Gas Monitoring above 500 °C

A wide range of high-value applications, including power generation and chemical manufacturing, involve harsh chemical conditions and extreme temperatures. In this work, we discuss the pairing of single crystal optical fiber with optically responsive, high-temperature stable perovskite oxide materials for monitoring of oxidizing and reduction gas streams up to 1000 °C. Optical sensing will be presented for hydrogen and oxygen monitoring in this temperature regime. Strategies will be discussed for improving stability and eliminating drift via multi-wavelength detection. The application of spatially resolved interrogation techniques, such as optical time domain reflectometry (OTDR) will be addressed for these sensors.

Wuenschell, Jeffrey↗

Creating a Digital Twin for a Hydropower System through 3D Object Modeling: Alder Dam FY23

Hydropower stands as the world's leading source of renewable electricity, with hydropower plants spanning the globe. A typical hydropower plant comprises essential components including the governor, excitation system, generator, thrust bearing, hydraulic turbine, transformer, main lead, metering and control devices, tailwater depression system, and dissolved oxygen monitoring. Each of these components undergoes various measures and monitoring procedures. These measurements are collected through a diverse array of systems, encompassing standalone sensors, programmable logic controllers (PLCs), Supervisory Control and Data Acquisition (SCADA) systems, Internet of Things (IoT) devices, and data acquisition and integration platforms like OSI/PI.

13 HYDRO ENERGY↗

A near-infrared optical nanosensor for measuring aerobic respiration in microbial systems

We developed a ratiometric oxygen-sensitive nanosensor and demonstrated application in monitoring metabolic oxygen consumption in microbial samples over time. Based on a near-infrared (NIR) emitting oxygen-quenched luminophore, platinum(II) octaethylporphine ketone (PtOEPK), along with a stable dioctadecyl dicarbocyanine reference dye (DiD), this nanosensor system provides an advantageous approach for overcoming imaging issues in biological systems, such as autofluorescence and optical scattering in the visible wavelength region. The dyes are encapsulated within a polymer-based nanoparticle matrix to maintain them at a constant ratio in biological samples, precluding the need for complex synthetic approaches. With this constant ratio of the two dyes, the nanosensor response can be measured as a ratio of their two signals, accounting for nanosensor concentration artifacts in measurements. The nanosensors are reversible, which enabled us to temporally monitor systems in which dissolved oxygen concentrations both increase and decrease. These sensors were applied for the monitoring of oxygen in samples of Saccharomyces cerevisiae (brewing yeast) in a 96-well optical fluorescence plate reader format over 60 h. By mixing the nanosensors directly into the sample well with the yeast, we were able to dynamically track metabolic activity changes over time due to varying cell concentration and exposure to an antimicrobial agent. As a result, this system could be a potential platform for high-throughput screening of various species or variants of microbes with unknown metabolic rates in response to external stimuli (antimicrobials, metabolites, etc.).

59 BASIC BIOLOGICAL SCIENCES↗

A scalable and autoclavable oxygen nanosensor platform for metabolic monitoring of Saccharomyces cerevisiae in a bioreactor and other in situ systems

Polymer-encapsulated dye nanoparticle sensors are a valuable approach to achieving in situ analyte measurements with luminescence; however, typical emulsion-based nanosensors are poorly suited for large-scale biological samples due to limitations of synthesis scalability and stability. Branched polyethylenimine (PEI) is a versatile polymer scaffold ideal for constructing nanoparticles with various covalently conjugated moieties due to their high density of reactive primary amines, high water solubility, and biological stability. In this work, we used branched polyethylenimine as a scaffold-based approach for making a stable and scalable ratiometric oxygen sensor. Pt (II) tetracarboxyporphine was used as an oxygen-sensing dye and coumarin 343 as a reference dye, all covalently linked to the PEI scaffold producing a product that could withstand sterilization procedures and easily be scaled. To minimize toxicity from the PEI scaffold, we conjugated it with 2000 MW PEG. The applicability of the sensors was demonstrated in a 200 mL Saccharomyces cerevisiae yeast culture, using orthogonal luminescent and electrochemical oxygen measurements to validate sensor response and measure the metabolic activity of the yeast in our culture. Further, this approach was able to match the sensitivity of our electrochemical measurements while improving upon drawbacks of other luminescent methods of oxygen detection, demonstrating effective monitoring for at least 20 h. Our scaffold-based approach is a modular and easily translatable technology that could be useful in various biotechnological applications.

59 BASIC BIOLOGICAL SCIENCES↗

Real-time and Autonomous Water Quality Monitoring System Based on Remotely Operated Vehicle

Existing water quality monitoring systems near hydropower facilities are limited by the lack of mobility of the sensors’ carrier platform. Most systems use a buoy, a mounting fixture attached to a solid structure, or a human worker, which significantly limits the selection of the sampling sites and poses safety risks during data collection and equipment maintenance. To improve on this technology, we developed an autonomous water quality monitoring system that can operate in dangerous water environments near hydropower facilities for water sampling at multiple locations. The goal is to enable safe, timely, and comprehensive water-quality data collection; maximize power generation revenue with improved operational control; and reduce Federal Energy Regulatory Commission and state water quality monitoring costs for compliance. The system incorporates a remotely operated vehicle as the mobile monitoring platform, a dissolved oxygen sensor for monitoring water quality, a tether management system for automatically winding the tether, a solar mobile docking platform for suppling power to the ROV, and a web-based graphical user interface for data post-processing and visualization. In addition, preliminary field research are presented to demonstrate the system capabilities.

Salalila, Aljon L.↗

Development of a Flow Stabilization Algorithm Enabling Measurement of Low Oxygen Concentrations in Liquid Sodium

To enhance the automated control of the plugging meter (PM) and thereby enhance detection fidelity in ultralow oxygen environments [≤1 parts per million by weight (wppm)], a novel proportional derivative controller has been implemented with conventional PM hardware. This ramp sign stabilized flow (RSSF) controller manipulates the sign (heating or cooling direction) at a fixed rate, enabling precise temperature adjustment around the saturation temperature of the bulk sodium. This adjustment helps maintain flow stability in a partially formed sodium oxide plug, thus greatly reducing the temperature amplitude in the plugging cycle and promoting simple and accurate oxygen determinations in addition to an increased sampling rate. Rather than relying on the subjective nature of indexing the time when the flow rate changes due to the plugging or unplugging onset to the PM temperature, a running average of the correlated oxygen concentration with time over multiple plugging events can provide oxygen readings ranging from an absolute uncertainty of 500 wppb in real time to less than 50 wppb for a 24-h sampling window. Finally, the RSSF controller was tested at 508 ± 7 wppb with measured oxygen of 542 ± 179 wppb, further reducing the variance between the saturation temperature and the plugging temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A system to control CO2 in O2 concentrations in aqueous media (Year 2 Report)

Per the Statement of Work, the following tasks were outlined for completion in Year 2: 1). Testing, modification, and optimization of the system. 2). Addition of oxygen manipulation and monitoring. 3). Expansion of CO2 bubbling/pH reduction system to include oxygen addition/removal and temperature control. 4). Investigate alkalinity modification by the microbial cultures and its impact on the carbonate chemistry control of the system. 5).Deliverable: Seawater chemistry and temperature control and monitoring system for microbial culture studies under present and future ocean conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Real-Time Elemental and Isotopic Measurements of Molten Salt Systems through Laser-Induced Breakdown Spectroscopy

Molten salt reactors are an emerging advanced nuclear reactor concept in which the fuel is dissolved into the working fluid in the form of a high-temperature molten salt. The complex, mobile, and corrosive nature of this fluid presents a fundamental challenge for analytical measurements. Tracking species throughout the reactor is important for ensuring proper operation. This article presents laser-induced breakdown spectroscopy (LIBS) used to monitor the elemental composition of a molten salt and corresponding hydrogen isotopic shifts in real-time. A NaNO 3 –KNO 3 eutectic salt was saturated with protium and deuterium gases, then the effluent aerosol stream formed using an argon sparging vessel was monitored with LIBS. This modular LIBS system permitted several spectrometers to be used simultaneously to capture high-resolution isotopic shifts and provide broadband elemental coverage. Further, the results exhibit how LIBS can be used to understand salt–gas chemical and physical interactions such as diffusion. Furthermore, LIBS’ broad elemental coverage can provide greater insight into the chemical reactions within the salt vessel such as the formation of water vapor by monitoring hydrogen and oxygen signatures simultaneously. Ultimately, this study demonstrates the analytical possibilities of LIBS for real-time monitoring of isotopes and elemental composition in molten salt systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Photoinduced patterning of oxygen vacancies to promote the ferroelectric phase of Hf 0.5 Zr 0.5 O 2

Photoinduced reductions in the oxygen vacancy concentration were leveraged to increase the ferroelectric phase fraction of Hf 0.5 Zr 0.5 O 2 thinfilms. Modest ( ~ 2 — 77 pJ=cm 2 ) laser doses of visible light (488 nm, 2.54 eV) spatially patterned the concentration of oxygen vacancies as monitored by photoluminescence imaging. Local, tip-based, near-field, nanoFTIR measurements showed that the photoinduced oxygen vacancy concentration reduction promoted formation of the ferroelectric phase (space group Pca2 1 ), resulting in an increase in the piezoelectric response measured by piezoresponse force microscopy. Photoinduced vacancy tailoring provides, therefore, a spatially prescriptive, postsynthesis, and low-entry method to modify phase in HfO 2 -based materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Real-Time Identification of Oxygen Vacancy Centers in LiNbO 3 and SrTiO 3 during Irradiation with High Energy Particles

Oxygen vacancies are known to play a central role in the optoelectronic properties of oxide perovskites. A detailed description of the exact mechanisms by which oxygen vacancies govern such properties, however, is still quite incomplete. The unambiguous identification of oxygen vacancies has been a subject of intense discussion. Interest in oxygen vacancies is not purely academic. Precise control of oxygen vacancies has potential technological benefits in optoelectronic devices. In this review paper, we focus our attention on the generation of oxygen vacancies by irradiation with high energy particles. Irradiation constitutes an efficient and reliable strategy to introduce, monitor, and characterize oxygen vacancies. Unfortunately, this technique has been underexploited despite its demonstrated advantages. This review revisits the main experimental results that have been obtained for oxygen vacancy centers (a) under high energy electron irradiation (100 keV–1 MeV) in LiNbO 3 , and (b) during irradiation with high-energy heavy (1–20 MeV) ions in SrTiO 3 . In both cases, the experiments have used real-time and in situ optical detection. Moreover, the present paper discusses the obtained results in relation to present knowledge from both the experimental and theoretical perspectives. Our view is that a consistent picture is now emerging on the structure and relevant optical features (absorption and emission spectra) of these centers. One key aspect of the topic pertains to the generation of self-trapped electrons as small polarons by irradiation of the crystal lattice and their stabilization by oxygen vacancies. What has been learned by observing the interplay between polarons and vacancies has inspired new models for color centers in dielectric crystals, models which represent an advancement from the early models of color centers in alkali halides and simple oxides. The topic discussed in this review is particularly useful to better understand the complex effects of different types of radiation on the defect structure of those materials, therefore providing relevant clues for nuclear engineering applications.

36 MATERIALS SCIENCE↗