Search NASA⌕ Search

SEARCH · Search NASA

Results for “oxygen spectral gaps”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Sea Surface Air Pressure Retrieval with MBARS

Global meteorological observations are essential in initialization and assimilation of numerical weather prediction (NWP) models. Many key weather variables such as temperature, humidity, and wind can be relatively well observed by in-situ and remote techniques from surface, suborbital and orbital platforms. However, sea surface air pressure cannot be well-sampled. Over open oceans, the pressure can only be observed by very limited buoys, ships, and oceanic platforms. There is no operational remote sensing method available for the crucial dynamic variable of the Earth’s climate and weather systems. Advanced techniques for global sea level pressure (SLP) observations are urgently needed for improving NWP models, particularly for improvement of severe weather forecasts. Recent studies on the space and airborne Microwave BArometric Radar and Sounder (MBARS) systems provide a great potential to fill the SLP observational gap. The systems studied have three channels with center frequencies at 65.5, 67.76 and 70 GHz. These channels are designed to operate at atmospheric oxygen (O2) absorption bands for column O2 mass measurements. When sea surface returns of spectrally closely-spaced paired channels are measured, surface reflection and atmospheric attenuation other than O2 are very similar, but the difference in O2 absorption is substantial. Thus, the differential absorption loss of this frequency pair leads to measures of atmospheric O2 amount. For the residual absorption loss caused by other agents, a third frequency having the same spectral space to the weak absorption frequency of the first pair can be used, which forms the second pair and produces the same residual as the first pair. Removal of the residual of this second pair from the first pair can further mitigate environmental impacts. Thus, this 3-channel approach will provide precise O2 amount retrievals. Since oxygen is well mixed in the atmosphere, the column air mass or SLP can be obtained. Currently, MBARS is rapidly maturing its advanced technology. An upcoming airborne field flight campaign is planned in late 2024. The 3-channel approach will be use in SLP retrievals. This MBARS team will discuss the physics-based SLP retrieval technique and report latest progresses in this upcoming AGU annual meeting.

O2 differential absorption↗

Beagle 2: The Next Exobiology Mission to Mars

Beagle 2 is a 60 kg probe (with a 30 kg lander) developed in the United Kingdom for inclusion on the European Space Agency's 2003 Mars Express. Beagle 2 will deliver to the Martian surface a payload which consists of a high percentage of science instruments to landed spacecraft mass. Beagle 2 will be launched in June, 2003 with Mars Express on a Soyuz-Fregat rocket from the Baikonur Cosmodrome in Kazakhstan. Beagle 2 will land on Mars on December 26, 2003 in the Isidis Planitia basin (approximately 10 degrees N and 275 degrees W), a large sedimentary basin that overlies the boundary between ancient highlands and northern plains. Isidis Planitia, the third largest basin on Mars, which is possibly filled with sediment deposited at the bottom of long-standing lakes or seas, offers an ideal environment for preserving traces of life. Beagle 2 was developed to search for organic material and other volatiles on and below the surface of Mars in addition to the study of the inorganic chemistry and mineralogy. Beagle 2 will utilize a mechanical mole and grinder to obtain samples from below the surface, under rocks and inside rocks. A pair of stereo cameras will image the landing site along with a microscope for examination of surface and rock samples. Analyses will include both rock and soil samples at various wavelengths, X-ray spectrometer and Mossbauer spectrometer as well as a search for organics and other light element species (e.g. carbonates and water) and measurement of their isotopic compositions. Beagle 2 has as its focus the goal of establishing whether evidence for life existed in the past on Mars at the Isidis Planitia site or at least establishing if the conditions were ever suitable. Carbonates and organic components were first recognized as existing on Mars when they were found in the Martian meteorite Nakhla. Romanek et al showed the carbonates in ALH84001 were formed at low temperatures. McKay et al noted possible evidence of early life on Mars within the ALH84001 meteorite. Thomas-Keprta et al showed the magnetite biomarkers in ALH84001's carbonates are indistinguishable from those formed by magnetotactic bacteria found on Earth. Gibson et al showed there was significant evidence for liquid water and biogenic products present on Mars across a 3.9 billion year period. A mechanical arm (PAW) operates from the lander and is used for science operations along with sample acquisition. Instruments attached to the PAW include: stereo cameras, Mossbauer instrument, X-ray fluorescence instrument, microscope, environmental sensors, rock corer/grinder, a spoon, mirror, brushes, a mole attachment for acquisition of subsurface to depths of 1 to 2 meters and an illumination device. Each camera has 14 filters which have been optimized for mineralogy composition, dust and water vapor detection. The microscope's camera is designed for viewing the size and shape of dust particles, rock surfaces, microfossils, and characteristics of the samples prior to introduction into the gas analysis package (GAP). The camera has a resolution of 4 microns/pixel, features four color capability (red, green, blue and UV (ultraviolet) fluoresence), a depth of focus of 40 micrometers and translation stage of +3 millimeters. The heart of the Beagle 2's life detection package is the gas analysis package (GAP), which consists of a mass spectrometer with collectors at fixed masses for precise isotopic ratio measurements and voltage scanning for spectral analysis. Primary aim of the GAP is to search for the presence of bulk constituents, individual species, and isotopic fractionations for both extinct and extent life along with studying the low-temperature geochemistry of the hydrogen, carbon, nitrogen and oxygen components on Mars from both the surface and atmosphere. GAP is a magnetic sector mass spectrometer with the range of 1 to 140 amu which can be operated in both the static and dynamic modes. A triple Faraday collector array will be used for C, N and O ratios along with a double Faraday array for H/D. Pulse counting electron multiplier will be utilized for noble gases and selected organics. Anticipated detection limits are at the picomole level for operation in the static mode of operation and high precision isotopic measurements will be made in the dynamic mode. Sample processing and preparation system consists of reaction vessels along with references. Sample ovens capable of being heated are attached to the manifold for sample combustion. Surface, subsurface materials and interior rock specimens will be combusted in pure oxygen gas at various temperature intervals to release organic matter and volatiles. Combustion process will permit detection of all forms and all atoms of carbon present in the samples. A chemical processing system is capable of a variety of conversion reactions. Gases are manipulated either by cryogenic or chemical reactions and passed through the gas handling portion of the vacuum system. There are two modes of operation: quantitative analysis and precise isotopic measurements. Additional information is contained in the original extended abstract.

Gibson, Everett K., Jr.↗

Far UV camera/spectrograph

In March 1610, Galileo Galilei reported the first use of a telescope to view mountains and maria on the Moon. On April 21, 1972, the Apollo 16 commander pointed a somewhat more complex optical instrument at the Earth from the Moon and obtained several remarkable photographs showing atmospheric rather than surface features. The optical part of the far UV camera (aperture, 7.5 cm) was not much larger than Galileo's telescope. Like his, this instrument was also pointed at other celestial objects that Galileo viewed, including the Milky Way and Jupiter, and the Large Magellanic Cloud (LMC), which is not visible from Italy. More important, the far UV camera/spectrograph recorded light in the invisible band of wavelengths between 50 and 160 nm, approximately one-third the wavelength that can penetrate the atmosphere of the Earth to ground-based telescopes. As described in more detail in this section, these UV observations from the Moon allow study of the entire atmosphere of the Earth and the geocorona. The photographs show hydrogen and other gases in the solar wind and interplanetary media, and they provide new data on stars, nebulae, and galaxies much farther away. When used as a spectrograph, the instrument distributes the light it receives according to wavelength, and the resulting spectrum shows bright lines or gaps known to be characteristic of various gases, such as hydrogen (H), helium (He), oxygen (O), nitrogen (N), and neon (Ne). If a gas cloud is hot, the atoms are excited and the spectrum shows bright emission lines; if it is cool, the atoms absorb light, leaving gaps or absorption lines. The far UV camera is blind to ordinary visible light; for that reason, the photographs show very few of the stars mapped by ground-based telescopes. Only the very-high-temperature (blue) stars of spectral classes O, B, and possibly A (temperatures from 50000 ° down to 10000°K) are expected to be recorded. Image blackness or density on the negatives also depends on the brightness of the star, which astronomers measure in an inverted logarithmic scale of magnitudes. A star of 6 magnitudes (mag.) can barely be seen with the unaided eye. An 11-mag. star is 100 times fainter, and a 12-mag. star is 2.5 times fainter yet. The faintest star recorded by the far UV camera is at least 11 mag., which is called the limiting magnitude.

George R. Carruthers↗

Atmospheric Pre-Corrected Differential Absorption Techniques to Retrieve Columnar Water Vapor: Application to AVIRIS 91/95 Data

Water vapor is one of the main forces for weather development as well as for mesoscale air transport processes. The monitoring of water vapor is therefore an important aim in remote sensing of the atmosphere. Current operational systems for water vapor detection use primarily the emission in the thermal infrared (AVHRR, GOES, ATSR, Meteosat) or in the microwave radiation bands (DMSP). The disadvantage of current satellite systems is either a coarse spatial (horizontal) resolution ranging from one to tens of kilometers or a limited insight into the lower atmosphere. Imaging spectrometry on the other hand measures total column water vapor contents at a high spatial horizontal resolution and has therefore the potential of filling these gaps. The sensors of the AVIRIS instrument are capable of acquiring hyperspectral data in 224 bands located in the visible and near infrared at 10 nm resolution. This data includes the information on constituents of the earth's surface as well as of the atmosphere. The optical measurement of water vapor can be performed using sensor channels located in bands or lines of the absorption spectrum. The AVIRIS sensor has been used to retrieve water vapor and with less accuracy carbon dioxide, oxygen and ozone. To retrieve the water vapor amount, the so called differential absorption technique has been applied. The goal of this technique is to eliminate background factors by taking a ratio between channels within the absorption band and others besides the band. Various ratioing methods on the basis of different channels and calculation techniques were developed. The influence of a trace gas of interest on the radiance at the sensor level is usually simulated by using radiative transfer codes. In this study, the spectral transmittance and radiance are calculated by MODTRAN3 simulations with the new DISORT option. The objective of this work is to test the best performing differential absorption techniques for imaging spectrometry of tropospheric water vapor.

Schlaepfer, Daniel↗