A pH-gated conformational switch regulates the phosphatase activity of bifunctional HisKA-family histidine kinases
Abstract not provided
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided
The process of ion channel gating—opening and closing—involves local and global structural changes in the channel in response to external stimuli. Conformational changes depend on the energetic landscape that underlies the transition between closed and open states, which plays a key role in ion channel gating. For the prokaryotic, pH-gated potassium channel KcsA, closed and open states have been extensively studied using structural and functional methods, but the dynamics within each of these functional states as well as the transition between them is not as well understood. In this study, we used solution nuclear magnetic resonance (NMR) spectroscopy to investigate the conformational transitions within specific functional states of KcsA. We incorporated KcsA channels into lipid bicelles and stabilized them into a closed state by using either phosphatidylcholine lipids, known to favor the closed channel, or mutations designed to trap the channel shut by disulfide cross-linking. A distinct state, consistent with an open channel, was uncovered by the addition of cardiolipin lipids. Using selective amino acid labeling at locations within the channel that are known to move during gating, we observed at least two different slowly interconverting conformational states for both closed and open channels. The pH dependence of these conformations and the predictable disruptions to this dependence observed in mutant channels with altered pH sensing highlight the importance of conformational heterogeneity for KcsA gating.
Multivalent counterions can be used to control both the conductivity and opening of a nanogate functionalized with weak polyelectrolytes.
Molecular transport in nanofluidic channels often differs drastically from conventional bulk transport. Strong confinement in those channels amplifies the roles of surface transport, surface defects, and molecular gates. Here, in this study, we introduce a chemical functionality at the nanotube rim that acts as a pH-triggered molecular gate by forming a movable lid that blocks the pore entrance. We use ion and proton transport measurements to show that these sub-1 nm diameter fluorescent ultrashort carbon nanotube porins (FUNPs) modulate ion transport by switching between the “open” and “closed” conformations of this gate. Specifically, at neutral pH the channel lid is open, allowing unimpeded ion transport through the gate, whereas at acidic pH values the lid forms a “closed” conformation that blocks transport through the nanotube. We also report first-principles MD simulations that confirm this gating mechanism and reveal molecular details of the ion and proton transport processes in these functional nanopores.
Members of the K 2P potassium channel family regulate neuronal excitability and are implicated in pain, anaesthetic responses, thermosensation, neuroprotection, and mood. Unlike other potassium channels, K 2P s are gated by remarkably diverse stimuli that include chemical, thermal, and mechanical modalities. It has remained unclear whether the various gating inputs act through separate or common channel elements. Here, we show that protons, heat, and pressure affect activity of the prototypical, polymodal K 2P , K 2P 2.1 (KCNK2/TREK-1), at a common molecular gate that comprises elements of the pore-forming segments and the N-terminal end of the M4 transmembrane segment. We further demonstrate that the M4 gating element is conserved among K 2P s and is employed regardless of whether the gating stimuli are inhibitory or activating. Our results define a unique gating mechanism shared by K 2P family members and suggest that their diverse sensory properties are achieved by coupling different molecular sensors to a conserved core gating apparatus.
The maximum sensitivity of classical nanowire (NW)-based pH sensors is defined by the Nernst limit of 59 mV/pH. For typical noise levels in ultra-small single-gated nanowire sensors, the signal-to-noise ratio is often not sufficient to resolve pH changes necessary for a broad range of applications. Recently, a new class of double-gated devices was demonstrated to offer apparent 'super-Nernstian' response (>59 mV/pH) by amplifying the original pH signal through innovative biasing schemes. However, the pH-sensitivity of these nanoscale devices as a function of biasing configurations, number of electrodes, and signal-to-noise ratio (SNR) remains poorly understood. Even the basic question such as 'Do double-gated sensors actually resolve smaller changes in pH compared to conventional single-gated sensors in the presence of various sources of noise?' remains unanswered. In this article, we provide a comprehensive numerical and analytical theory of signal and noise of double-gated pH sensors to conclude that, while the theoretical lower limit of pH-resolution does not improve for double-gated sensors, this new class of sensors does improve the (instrument-limited) pH resolution.
Highlights: • pH-dependent gating of the KcsA channel is regulated by the CPD. • E146 is the most essential amino acid for pH sensing by the KcsA. • The protonated-mimicking mutant, E146Q, is constitutively open independent of pH. • Minimal rearrangement of the CPD is sufficient for opening of the KcsA. - Abstract: The KcsA channel is a proton-activated potassium channel. We have previously shown that the cytoplasmic domain (CPD) acts as a pH-sensor, and the charged states of certain negatively charged amino acids in the CPD play an important role in regulating the pH-dependent gating. Here, we demonstrate the KcsA channel is constitutively open independent of pH upon mutating E146 to a neutrally charged amino acid. In addition, we found that rearrangement of the CPD following this mutation was not large. Our results indicate that minimal rearrangement of the CPD, particularly around E146, is sufficient for opening of the KcsA channel.
Inspired by biological ion channels, artificial nanopore-based architectures have been developed for smart ion/molecular transport control with potential applications to iontronics and energy conversion. Advances in nanofabrication technology enable simple, versatile construction methods, and post-fabrication functionalization delivers nanochannels with unique ion transport-control attributes. Here, we characterize a pH-responsive, charge-selective dual-gating block copolymer (BCP) membrane composed of polystyrene-b-poly(4-vinylpyridine) (PS 48400 -b-P4VP 21300 ), capable of self-organizing into highly ordered nanocylindrical domains. Because the PS-b-P4VP membrane exhibits pH-dependent structural transitions, it is suitable for designing intelligent pH-gated biomimetic channels, for example, exhibiting on–off transport switching at pH values near the pK a of P4VP with excellent anion permselectivity at pH < pK a . Introducing the BCP membrane onto nanopore electrode arrays (BCP@NEAs) allows the BCP to serve as a pH-responsive gate controlling ion transfer into the NEA nanopores. Such selectively transported and confined ions are detected by using a 100 nm gap dual-ring nanoelectrode structure capable of enhancing current output by efficient redox cycling with an amplification factor >10 2 . In addition, BCP@NEAs exhibit extraordinary pH-gated ion selectivity, resulting in a 3380-fold current difference between anion and cation probes at pH 3.0. Furthermore, this hierarchically organized BCP-gated NEA system can serve as a template for the development of other stimulus-responsive ion gates, for example, those based on temperature and ligand gating, thus exploiting the intrinsic advantages of NEAs, such as enhanced sensitivity based on redox cycling, which may lead to technological applications such as engineered biosensors and iontronic devices.
In this work, we report on the optimization of a double-gate silicon-on-insulator field effect device operation to maximize pH sensitivity. The operating point can be fine tuned by independently biasing the fluid and the back gate of the device. Choosing the bias points such that device is nearly depleted results in an exponential current response--in our case, 0.70 decade per unit change in pH. This value is comparable to results obtained with devices that have been further scaled in width, reported at the forefront of the field, and close to the ideal value of 1 decade/pH. By using a thin active area, sensitivity is increased due to increased coupling between the two conducting surfaces of the devices.
We present the real-time x-ray irradiation response of charge and pH sensitive solution gate AlGaN/GaN high electron mobility transistors. The devices show stable and reproducible behavior under and following x-ray radiation, including a linear integrated response with dose into the muGy range. Titration measurements of devices in solution reveal that the linear pH response and sensitivity are not only retained under x-ray irradiation, but an irradiation response could also be measured. Since the devices are biocompatible, and can be simultaneously operated in aggressive fluids and under hard radiation, they are well-suited for both medical radiation dosimetry and biosensing applications.
The transport, noise, and photosensitivity properties of an array of silicon nanowire (NW) p{sup +}-p-p{sup +} field-effect transistors (FETs) are investigated. The peculiarities of photosensitivity and detectivity are analyzed over a wide spectrum range. The absorbance of p-Si NW shifts to the short wavelength region compared with bulk Si. The photocurrent and photosensitivity reach increased values in the UV range of the spectrum at 300 K. It is shown that sensitivity values can be tuned by the drain-source voltage and may reach record values of up to 2–4 A/W at a wavelength of 300 nm at room temperature. Low-frequency noise studies allow calculating the photodetectivity values, which increase with decreasing wavelength down to 300 nm. We show that the drain current of Si NW biochemical sensors substantially depends on pH value and the signal-to-noise ratio reaches the high value of 10{sup 5}. Increasing pH sensitivity with gate voltage is revealed for certain source-drain currents of pH-sensors based on Si NW FETs. The noise characteristic index decreases from 1.1 to 0.7 with the growth of the liquid gate voltage. Noise behavior is successfully explained in the framework of the correlated number-mobility unified fluctuation model. pH sensitivity increases as a result of the increase in liquid gate voltage, thus giving the opportunity to measure very low proton concentrations in the electrolyte medium at certain values of the liquid gate voltage.
Abstract not provided
In response to acidic pH, the widely expressed proton-activated chloride (PAC) channel opens and conducts anions across cellular membranes. By doing so, PAC plays an important role in both cellular physiology (endosome acidification) and diseases associated with tissue acidosis (acid-induced cell death). Despite the available structural information, how proton binding in the extracellular domain (ECD) leads to PAC channel opening remains largely unknown. Here, through comprehensive mutagenesis and electrophysiological studies, we identified several critical titratable residues, including two histidine residues (H130 and H131) and an aspartic acid residue (D269) at the distal end of the ECD, together with the previously characterized H98 at the transmembrane domain–ECD interface, as potential pH sensors for human PAC. Mutations of these residues resulted in significant changes in pH sensitivity. Some combined mutants also exhibited large basal PAC channel activities at neutral pH. By combining molecular dynamics simulations with structural and functional analysis, we further found that the β12 strand at the intersubunit interface and the associated “joint region” connecting the upper and lower ECDs allosterically regulate the proton-dependent PAC activation. Our studies suggest a distinct pH-sensing and gating mechanism of this new family of ion channels sensitive to acidic environment.
Between 1955 and 1988, the F/H Area Seepage Basins located in the center of SRS received approximately 6,814,000 m{sup 3} of acidic waste solutions containing radionuclides and dissolved metals. Uranium (VI) is a key contaminant of concern in groundwater associated with the basins. The pump-and-treat water treatment unit designed and built in 1997 to remove metals and radionuclides eventually became less effective, prompting research for new remedial alternatives. The pump-and-treat system was discontinued in 2004, replaced with a funnel-and-gate system in which base solutions are injected at the gates to raise pH. To take advantage of the potential formation of uranium silicate minerals, Florida International University - Applied Research Center (FIU-ARC), in collaboration with Savannah River National Laboratory (SRNL), is conducting an investigation into a base containing sodium silicate to evaluate whether these solutions have sufficient alkalinity to correct the acidic nature of the aquifer sediments. The research was extended to investigate if U(VI) is bound to colloidal silica and if any synergy exists between humic acid (HA) and colloidal Si that would influence the removal of uranium. Humic substances (HS) are a major component of soil organic matter and are known for their abilities to influence the migration behavior and fate of heavy metals. Studies showed that HA function as an important ion exchange and metal-complexing ligand, carrying a large number of functional groups with high complexing capacity that can greatly affect the mobility behavior of actinides in natural systems. The study investigates if there are any synergistic interactions between U(VI) ions, humic acid and colloidal silica under oxidized conditions and studies the influence of HA and Si on the sorption of U(VI) onto sediments collected from the F/H Area. The experiments also evaluated the effects of different environmental variables such as pH, presence of U(VI) and varying concentrations of HA on the sorption behavior of U(VI) in multi-component batch systems in the pH range between 3 and 8. Several background sediment samples were collected at SRS from archived cores obtained during installation of the well FSB 91C and used for preparation of triplicate samples. The experimental matrix was set up as follows: - Batch 1: Si (3.5 mM) + U (VI) (0.5 ppm) (no sediments and no HA); - Batch 2: Si (3.5 mM) + U (VI) (0.5 ppm) + HA (10 ppm) (no sediments); - Batch 3: U (VI) (0.5 ppm) + HA (10 ppm) (no Si and no sediments); - Batch 4: Sediments + Si (3.5 mM) + U (VI) (0.5 ppm) (no HA); - Batch 5: Sediments + Si (3.5 mM) + U (VI) (0.5 ppm) + HA; - Batch 6: Sediments + U (VI) (0.5 ppm) + HA, (no Si); - Batch 7: Sediments + U (VI) (0.5 ppm) (no Si and no HA). All samples were prepared in triplicate 50-mL conical tubes. All control and experimental tubes were vortexed and kept on a shaker for 24 h at 100 rpm and room temperature. Results showed that the sediment-bearing batches typically exceeded the performance of non-sediment batches. Results showed that the sorption of U(VI) onto sediments was influenced by the pH and the presence of HA. At low pH 3, the addition of HA slightly enhances U(VI) sorption compared to the HA-free samples. This result is consistent with other studies; in the acidic pH range, the addition of HA slightly enhances U(VI) sorption relative to the HA-free system. Conversely, in the pH range of 4 to 7, the sorption of U(VI) on Si was reduced in the presence of HA in comparison to the system without HA. In subsequent experiments the concentration of HA will be increased to 50 ppm. (authors)
The sensitivity of a standard ion-sensitive field-effect transistor is limited to be 59.2 mV/pH (Nernst limit) at room temperature. Here, a concept based on laterally synergic electric-double-layer (EDL) modulation is proposed in order to overcome the Nernst limit. Indium-zinc-oxide EDL transistors with two laterally coupled gates are fabricated, and the synergic modulation behaviors of the two asymmetric gates are investigated. A high sensitivity of ∼168 mV/pH is realized in the dual-gate operation mode. Laterally synergic modulation in oxide-based EDL transistors is interesting for high-performance bio-chemical sensors.
Highlights: • The α-helical content of the C-terminus is decreased with a pH increase. • The thermostability of the C-terminus is decreased with a pH increase. • Zn{sup 2+} binds to His{sup 244} and His{sup 266} residues within the C-terminal domain. • The binding of Zn{sup 2+} to His{sup 244} residue is an endothermic heat reaction. • The binding of Zn{sup 2+} to His{sup 266} residue is an exothermic heat reaction. - Abstract: The voltage-gated proton channel Hv1 is strongly sensitive to Zn{sup 2+}. The H{sup +} conduction is decreased at a high concentration of Zn{sup 2+} and Hv1 channel closing is slowed by the internal application of Zn{sup 2+}. Although the recent studies demonstrated that Zn{sup 2+} interacts with the intracellular C-terminal domain, the binding sites and details of the interaction remain unknown. Here, we studied the pH-dependent structural stability of the intracellular C-terminal domain of human Hv1 and showed that Zn{sup 2+} binds to His{sup 244} and His{sup 266} residues. The thermodynamics signature of Zn{sup 2+} binding to the two sites was investigated by isothermal titration calorimetry. The binding of Zn{sup 2+} to His{sup 244} (mutant H266A) and His{sup 266} (mutant H244A) were an endothermic heat reaction and an exothermic heat reaction, respectively.
The development of pH sensors is of great interest due to its extensive application in several areas such as industrial processes, biochemistry and particularly medical diagnostics. In this study, the pH sensing properties of an extended gate field effect transistor (EGFET) based on melanin thin films as active layer are investigated and the physical mechanisms related to the device operation are discussed. Thin films were produced from different melanin precursors on indium tin oxide (ITO) and gold substrates and were investigated by Atomic Force Microscopy and Electrochemical Impedance Spectroscopy. Experiments were performed in the pH range from 2 to 12. EGFETs with melanin deposited on ITO and on gold substrates showed sensitivities ranging from 31.3 mV/pH to 48.9 mV/pH, depending on the melanin precursor and the substrate used. The pH detection is associated with specific binding sites in its structure, hydroxyl groups and quinone imine.