Search NASA⌕ Search

SEARCH · Search NASA

Results for “pH indicators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Chemochromic Indicators for the Detection of Hypergolic Fuels

The toxicity and hazard level associated with the use of hypergolic fuels necessitates the development of technology capable of detecting the presence of such fuels in a variety of different environments and conditions. The most commonly used sensors for the detection of hypergolic fuels are electrochemical in nature, which have serious limitations when used as area monitoring devices. Recent collaborative work between Kennedy Space Center and ASRC Aerospace has led to the development of indicators which exhibit a color change upon exposure to hydrazine under different conditions. The indicators under investigation on this developmental effort are para-dimethylaminobenzaldehyde (PDAB), various formulations of universal pH indicators, and potassium tetrachloroaurate (KAuCl4). These chemochromic indicators have been tested for the detection of hydrazine under various conditions: pure liquid fuel, aqueous fuel solution, saline aqueous fuel solutions, vapor fuel, and 3-month shelf life study, which included UV protection, thermal extremes, and normal storage conditions. The hypergolic fuel indicator test was conducted with the indicator impregnated into a wipe material to test the applicability of the indicator to be used to capture (absorb) and indicate the presence of hypergolic fuels. Each of the indicators performed well, with the universal pH indicator being the best candidate because of the visible response color change and the indicator stability after the shelf life study.

Santiago-Maldonado, E.↗

Enabling Experimental Evolution: Multi-Parameter Sensor System Integration into a Culture/Stressor Biofluidics System

Experimental evolution (EE) exposes microbial communities to ecological stressors, simulating dynamics up to near-extinction events. Combined with comparative sequencing and other molecular tools, such data can inform the genetic and other biological mechanisms underlying extremophile adaptation, and other observed effects. Automating this type of experiment using biofluidics can mitigate many traditional obstacles, including delays in assay results and environment adjustment and the need for many replicates. A first-generation device for automating EE procedures, the Automated Adaptive Directed Evolution Chamber (AADEC), was developed at NASA Ames. UV-C radiation was the stressor, an LED-photodiode array measured optical density, magnetic agitation and peristaltic pump systems ensured nutrient availability, and Arduino microcontrollers provided control. Escherichia coli in LB kanamycin media was used for testing and performance verification. A manual laboratory procedure with timed exposure to UV-C was performed to typify tolerance acquisition. Approximately a 106 factor increase in survival ratio was recorded over multiple iterations. Currently, a second-generation device is being developed integrating more real-time sensors: redox potential (ORP), indicating available/consumed metabolic energy; dissolved oxygen (DO), indicating aerobic/anaerobic growth; pH, indicating metabolic products; and electrical conductivity (EC), another indicator of metabolic products. The EC sensor system was constructed and calibrated in-house and matched commercial sensors in the required range. A Raspberry Pi computer automated the electrical system, allowing real-time data acquisition. The fluidics card was made of CNC-milled polycarbonate for biocompatibility. Each sensor parameter can also be used as a selection pressure alone or in combination with others to create extreme microbial environments. As a proof of concept, this work demonstrated sensor operation in one pair of growth-sensor chambers. It can be expanded to a multi-chamber system to enable inter-culture comparisons and multi-population studies. The prior Arduino system will be ported to the RPi system. Future stressors to be added include thermal, reactive oxygen species, and varying nutrient availability.

Govinda Raj, Chinmayee↗

Cytoplasmic pH dynamics in maize pulvinal cells induced by gravity vector changes

In maize (Zea mays) and other grasses, changes in orientation of stems are perceived by pulvinal tissue, which responds to the stimulus by differential growth resulting in upward bending of the stem. The amyloplast-containing bundle sheath cells are the sites of gravity perception, although the initial steps of gravity perception and transmission remain unclear. In columella cells of Arabidopsis roots, we previously found that cytoplasmic pH (pH(c)) is a mediator in early gravitropic signaling (A.C. Scott, N.S. Allen [1999] Plant Physiol 121: 1291-1298). The question arises whether pH(c) has a more general role in signaling gravity vector changes. Using confocal ratiometric imaging and the fluorescent pH indicator carboxy seminaphtorhodafluor acetoxymethyl ester acetate, we measured pH(c) in the cells composing the maize pulvinus. When stem slices were gravistimulated and imaged on a horizontally mounted confocal microscope, pH(c) changes were only apparent within the bundle sheath cells, and not in the parenchyma cells. After turning, cytoplasmic acidification was observed at the sides of the cells, whereas the cytoplasm at the base of the cells where plastids slowly accumulated became more basic. These changes were most apparent in cells exhibiting net amyloplast sedimentation. Parenchyma cells and isolated bundle sheath cells did not show any gravity-induced pH(c) changes although all cell types responded to external stimuli in the predicted way: Propionic acid and auxin treatments induced acidification, whereas raising the external pH caused alkalinization. The results suggest that pH(c) has an important role in the early signaling pathways of maize stem gravitropism.

Non-NASA Center↗

The Future of Astronaut Nutrition: Daily Production of Kefir Nutrient Packs in a Lunar Analog Mission

Astronaut nutrition will need to be supplemented with fresh nutrients and probiotics for long duration space travel. Kefir is a fermented milk beverage that provides probiotic bacteria, protein, calcium, and vitamin K. It has been historically cultured for thousands of years and is a modern-day health food. During the BioNutrients-2 experiment, one generation of kefir was cultured by astronauts on the ISS in fluorinated ethylene propylene (FEP) bags. This follow-on experiment aimed to test the hypothesis that kefir can be produced at ambient temperatures and safely passaged to make a series of nutrient packs in an analog environment. The Hawaiian Space Exploration Analog and Simulation (HI-SEAS) is a semi-controlled habitat located on the Mauna Loa volcano on the island of Hawaii at 2,500 m elevation. The recent EMMIHS (EuroMoonMars, International MoonBase Alliance, HI-SEAS) missions comprised of interdisciplinary, international crews for mock lunar missions. During a six-day mission in March 2024, crew members tested continuous passaging of kefir cultures (C-FIR commercial strain). After approximately 24 hours of growth, a portion of culture was used to seed the next generation of culture bags for four passages. A color board and pH indicator allowed the crew to easily determine when the culture had reached optimal pH. Laboratory analysis at NASA Ames Research Center showed that the pH met Kefir standards (<5). The yeast and lactic acid bacteria were in normal range and no contamination was detected in the final passage. By successfully accomplishing this experiment the team has demonstrated the ability to safely produce daily cultures of kefir in a microgravity applicable growth system.

Astronaut nutrition↗

Wipes, Coatings, and Patches for Detecting Hydrazines

Three color-indicating devices have been conceived as simple, rapid, inexpensive means of detecting hazardous liquid and gaseous substances in settings in which safety is of paramount concern and it would be too time-consuming or otherwise impractical to perform detection by use of such instruments as mass spectrometers. More specifically, these devices are designed for detecting hypergolic fuels (in particular, hydrazines) and hypergolic oxidizers in spacecraft settings, where occasional leakage of these substances in liquid or vapor form occurs and it is imperative to take early corrective action to minimize adverse health effects. With suitable redesign, including reformulation of their color indicator chemicals, these devices could be adapted to detection of other hazardous substances in terrestrial settings (e.g., industrial and military ones). One of the devices is a pad of a commercially available absorbent material doped with a color indicator. The absorbent material is made from 70 percent polyester and 30 percent nylon and can absorb about eight times its own weight of liquid. The color indicator is a mixture of conventional pH color indicator chemicals. Hydrazine and monomethyl hydrazine, which are basic, cause the color indicator to turn green. In the original intended application, the pad is wiped on a space suit that is suspected of having been exposed to leaking monomethyl hydrazine during a space walk, before the wearer returns to the interior of the spacecraft. If the wiped surface is contaminated with hydrazine, the pad turns green. In addition, the pad absorbs hydrazine from the wiped surface, thereby reducing or eliminating the hazard. Used pads, including ones that show contamination by hydrazine, can be stored in a sealed plastic bag for subsequent disposal. The second device, which has been proposed but not yet developed, would comprise a color indicator material in the form of either a coating on a space suit (or other protective garment) or a coating on a sheet that could be easily attached to and detached from the protective garment. The coating material would be a hydrogel doped with a suitable pH indicator. The hydrogel would also serve to maintain a level of moisture needed to support the chemical reaction mentioned in the next sentence. In addition to changing color to indicate the presence of any hypergolic fuel (which is basic) or hypergolic oxidizer (which is acidic) that might splash on the space suit, the pH indicator would also react with the hypergolic fuel or oxidizer and thereby bind it. The third device is a color dosimeter for detecting hydrazine liquid or vapor coming from microscopic leaks. This device is designed to satisfy several requirements specific to its original intended use in the auxiliary power unit of the space shuttle. These requirements include stability under vacuum, stability at moderate temperature, fast and irreversible change in color upon exposure to hydrazine, and visibility of the color change through polyimide tape.

Young, Rebecca↗

Kinetic and mechanistic analysis of nonenzymatic, template-directed oligoribonucleotide ligation

The role of divalent cations in the mechanism of pyrophosphate-activated, template-directed oligoribonucleotide ligation has been investigated. The dependence of the reaction rate on Mg2+ concentration suggests a kinetic scheme in which a Mg2+ ion must bind before ligation can proceed. Mn2+, Ca2+, Sr2+, and Ba2+ can also catalyze the reaction. Although Pb2+ and Zn2+ do not catalyze the reaction in the absence of other divalent ions, they significantly modulate the reaction rate when added in the presence of Mg2+, with Pb2+ stimulating the reaction (up to 65-fold) and Zn2+ inhibiting the reaction. The logarithm of the ligation rate increases linearly, with slope of 0.95, as a function of pH, indicating that the reaction involves a single critical deprotonation step. The ligation rates observed with the different divalent metal ion catalysts (Mn2+ > Mg2+ > Ca2+ > Sr2+ = Ba2+) vary inversely with the pKa values of their bound water molecules. The pH profile and these relative ligation rates suggest a mechanism in which a metal-bound hydroxide ion located near the ligation junction promotes catalysis, most likely by deprotonation of the hydroxl nucleophile. The effects of changing either the leaving group or the attacking hydroxyl, together with the large delta S(++) value for oligonucleotide ligation (about -20 eu), are consistent with an associative transition state.

Non-NASA Center↗

Optoelectronic pH Meter: Further Details

A collection of documents provides further detailed information about an optoelectronic instrument that measures the pH of an aqueous cell-culture medium to within 0.1 unit in the range from 6.5 to 7.5. The instrument at an earlier stage of development was reported in Optoelectronic Instrument Monitors pH in a Culture Medium (MSC-23107), NASA Tech Briefs, Vol. 28, No. 9 (September 2004), page 4a. To recapitulate: The instrument includes a quartz cuvette through which the medium flows as it is circulated through a bioreactor. The medium contains some phenol red, which is an organic pH-indicator dye. The cuvette sits between a light source and a photodetector. [The light source in the earlier version comprised red (625 nm) and green (558 nm) light-emitting diodes (LEDs); the light source in the present version comprises a single green- (560 nm)-or-red (623 nm) LED.] The red and green are repeatedly flashed in alternation. The responses of the photodiode to the green and red are processed electronically to obtain the ratio between the amounts of green and red light transmitted through the medium. The optical absorbance of the phenol red in the green light varies as a known function of pH. Hence, the pH of the medium can be calculated from the aforesaid ratio.

Jeevarajan, Antony S.↗

The photochemical cycle of bacteriorhodopsin

The reaction cycle of bacteriorhodopsin in the purple membrane isolated from Halobacterium halobium has been studied by optical absorption spectroscopy using low-temperature and flash kinetic techniques. After absorption of light, bacteriorhodopsin passes through at least five distinct intermediates. The temperature and pH dependence of the absorbance changes suggests that branch points and/or reversible steps exist in this cycle. Flash spectroscopy in the presence of a pH-indicating dye shows that the transient release of a proton accompanies the photoreaction cycle. The proton release occurs from the exterior and the uptake is on the cytoplasmic side of the membrane, as required by the function of bacteriorhodopsin as a light-driven proton pump. Proton translocating steps connecting release and uptake are indicated by deuterium isotope effects on the kinetics of the cycle. The rapid decay of a light-induced linear dichroism shows that a chromophore orientation change occurs during the reaction cycle.

Lozier, R. H.↗

A dry-surface coating method for visualization of separation

A relatively simple and reasonably accurate dry-surface coating method for visualization of the separation line on a bluff body was devised and successfully tested. This technique is based on the color reaction of a dry film containing a pH indicator with an appropriate gas released in the body wake. The dry-surface coating method is effective at any Reynolds number and for both incident laminar and turbulent flows. It further supplies a colorful permanent of consistently good photographic quality of the separation line. The effectiveness and accuracy of this technique were tested in visualizing the separation angle on a circular cylinder in both laminar and turbulent crossflows at subcritical Reynolds numbers. Separation angles revealed by the visualization were within + or - 4 percent of their counterparts deduced from the mean wall pressure distribution.

Sadeh, W. Z.↗

Self-contained, single-use hose and tubing cleaning module

A self contained, single use hose and tubing cleaning module which utilizes available water supplies without requiring access to precision cleaning facilities is presented. The module is attached to the water source at the inlet side and to the hose or tubing to be cleaned at the outlet side. The water flows through a water purification zone, a detergent dispensing zone, a filtration zone before the detergent laden water flows into the tubing to clean the tubing walls. The module contains an embedded pad which is impregnated with a pH indicator to indicate to the user when the detergent has dissolved and rinsing of the tubing begins.

Rollins, Fred P.↗

Convective flows in enclosures with vertical temperature or concentration gradients

The transport process in the fluid phase during the growth of a crystal has a profound influence on the structure and quality of the solid phase. In vertical growth techniques the fluid phase is often subjected to vertical temperature and concentration gradients. The main objective is to obtain more experimental data on convective flows in enclosures with vertical temperature or concentration gradients. Among actual crystal systems the parameters vary widely. The parametric ranges studied for mass transfer are mainly dictated by the electrochemical system employed to impose concentration gradients. Temperature or concentration difference are maintained between two horizontal end walls. The other walls are kept insulated. Experimental measurements and observations were made of the heat transfer or mass transfer, flow patterns, and the mean and fluctuating temperature distribution. The method used to visualize the flow pattern in the thermal cases is an electrochemical pH-indicator method. Laser shadowgraphs are employed to visualize flow patterns in the solutal cases.

Wang, L. W.↗

Convective flows in enclosures with vertical temperature or concentration gradients

The transport process in the fluid phase during the growth of a crystal has a profound influence on the structure and quality of the solid phase. In vertical growth techniques the fluid phase is often subjected to vertical temperature and concentration gradients. The main objective is to obtain more experimental data on convective flows in enclosures with vertical temperature or concentration gradients. Among actual crystal systems the parameters vary widely. The parametric ranges studied for mass transfer are mainly dictated by the electrochemical system employed to impose concentration gradients. Temperature or concentration difference are maintained between two horizontal end walls. The other walls are kept insulated. Experimental measurements and observations were made of the heat transfer or mass transfer, flow patterns, and the mean and fluctuating temperature distribution. The method used to visualize the flow pattern in the thermal cases is an electrochemical pH-indicator method. Laser shadowgraphs are employed to visualize flow patterns in the solutal cases.

Wang, L. W.↗

BioNutrients-3: Precision Fermentation, Pasteurization, and Pathogen Detection - Towards Safe Fermentation and Production of Nutrients in Space

The BioNutrients (BN) project is developing a microbial manufacturing approach to supplement the NASA food system to address known nutrient degradation associated with long-term storage. BN uses synthetic biology to deliver high-value nutrients and therapeutics through genetic engineering of microbes and production of fermented food products like yogurt and kefir, in a fully dehydrated system. On-demand production of nutrients for human consumption requires rigorous safety protocols to ensure contaminants are not introduced during the fermentation process. The third iteration of the BN flight project, BN-3, further develops the BN project by investigating strategies for pathogen detection and pasteurization in microgravity. BN-3 will test the limits of pathogen detection using whole genome sequencing, standard microbial assays and the NASA Ames E-Nose, a volatile carbon nano tube-based sensor array, to detect unwanted microbes. BN-3 also expands on the number of nutrients produced in a single bioreactor to enhance efficiency of the system by combining production of B vitamins in conjunction with the carotenoids, beta-carotene and zeaxanthin. Serial production of food products through yogurt passaging, new updates to the fluorinated ethylene propylene bags to allow crew access via a straw, as well as use of a food safe pH indicator dye to indicate readiness of the food product, will further enhance the useability of this system. This presentation will provide status of the BN-3 flight project with the aim of advancing in-space biomanufacturing for on-demand microbially based food production for future space exploration.

Biomanufacturing↗

Noninvasive, near infrared spectroscopic-measured muscle pH and PO2 indicate tissue perfusion for cardiac surgical patients undergoing cardiopulmonary bypass

OBJECTIVE: To determine whether near infrared spectroscopic measurement of tissue pH and Po2 has sufficient accuracy to assess variation in tissue perfusion resulting from changes in blood pressure and metabolic demand during cardiopulmonary bypass. DESIGN: Prospective clinical study. SETTING: Academic medical center. SUBJECTS: Eighteen elective cardiac surgical patients. INTERVENTION: Cardiac surgery under cardiopulmonary bypass. MEASUREMENTS AND MAIN RESULTS: A near infrared spectroscopic fiber optic probe was placed over the hypothenar eminence. Reference Po2 and pH sensors were inserted in the abductor digiti minimi (V). Data were collected every 30 secs during surgery and for 6 hrs following cardiopulmonary bypass. Calibration equations developed from one third of the data were used with the remaining data to investigate sensitivity of the near infrared spectroscopic measurement to physiologic changes resulting from cardiopulmonary bypass. Near infrared spectroscopic and reference pH and Po2 measurements were compared for each subject using standard error of prediction. Near infrared spectroscopic pH and Po2 at baseline were compared with values during cardiopulmonary bypass just before rewarming commenced (hypotensive, hypothermic), after rewarming (hypotensive, normothermic) just before discontinuation of cardiopulmonary bypass, and at 6 hrs following cardiopulmonary bypass (normotensive, normothermic) using mixed-model analysis of variance. Near infrared spectroscopic pH and Po2 were well correlated with the invasive measurement of pH (R2 =.84) and Po2 (R 2 =.66) with an average standard error of prediction of 0.022 +/- 0.008 pH units and 6 +/- 3 mm Hg, respectively. The average difference between the invasive and near infrared spectroscopic measurement was near zero for both the pH and Po2 measurements. Near infrared spectroscopic Po2 significantly decreased 50% on initiation of cardiopulmonary bypass and remained depressed throughout the bypass and monitored intensive care period. Near infrared spectroscopic pH decreased significantly during cardiopulmonary bypass, decreased significantly during rewarming, and remained depressed 6 hrs after cardiopulmonary bypass. Diabetic patients responded differently than nondiabetic subjects to cardiopulmonary bypass, with lower muscle pH values (p =.02). CONCLUSIONS: Near infrared spectroscopic-measured muscle pH and Po2 are sensitive to changes in tissue perfusion during cardiopulmonary bypass.

Non-NASA Center↗

ITCS Test Strip Development and Certification

Internal coolant loops used for International Space Station thermal control must be periodically monitored for system health, including pH, biocide levels and any indication of ammonia. The presence of ammonia, possible via a microleak in the interface between the internal and external thermal control systems, could be a danger to the crew. The Internal Thermal Control System (ITCS) Sampling Kit uses test strips as a colorimetric indicator of pH and concentrations of biocide and free ammonia. This paper describes the challenges in designing an ammonia colorimetric indicator in a variable pH environment, as well as lessons learned, ultimately resulting in a robust test strip to indicate a hazardous ammonia leak.

Carrigan, Caitlin↗

Photochemistry of monodentate and bidentate carbonato complexes of rhodium (3)

A scheme for the photochemical fixation of water is proposed which involves a five-step reaction sequence; the first step involves the 2 electron reduction of a metal by a coordinated carbonate ligand, with corresponding oxidation of the carbonate to CO2 and O2. Ligand field photolysis of trans- (RH(en)2 H2O CO3) ClO4, and (Rh(en)2 CO3) CLO4 have been studied in the solid state and in aqueous solution at various pH values. Both salts are photoinert in the solid phase, but are quite photoreactive in aqueous solution. In solution, the monodentate ion undergoes efficient isomerization to a mixture of cis and trans - (Rh(en)2 H2O CO3)+, presumably with water exchange. A minor pH increase upon photolysis is evidence of inefficient carbonate (CO3 =) release, with formation of (Rh(en)2 (H2O)2)3+. In contrast, aqueous solutions of the bidentate carbonato complex undergo efficient pH decrease upon ligand field photolysis. Changes in the electronic spectrum (200-500 nm) and pH changes indicate that the desired redox is occurring. The pH increase is due to the aqueous behavior of CO2.

Sheridan, P. S.↗

In-Situ and Experimental Evidence for Acidic Weathering of Rocks and Soils on Mars

Experimental data for alteration of synthetic Martian basalts at pH=0-1 indicate that chemical fractionations at low pH are vastly different from those observed during terrestrial weathering. Rock analyses from Gusev crater are well described by the relationships apparent from low pH experimental alteration data. A model for rock surface alteration is developed which indicates that a leached alteration zone is present on rock surfaces at Gusev. This zone is not chemically fractionated to a large degree from the underlying rock interior, indicating that the rock surface alteration process has occurred at low fluid-to-rock ratio. The geochemistry of natural rock surfaces analyzed by APXS is consistent with a mixture between adhering soil/dust and the leached alteration zone. The chemistry of rock surfaces analyzed after brushing with the RAT is largely representative of the leached alteration zone. The chemistry of rock surfaces analyzed after grinding with the RAT is largely representative of the interior of the rock, relatively unaffected by the alteration process occurring at the rock surface. Elemental measurements from the Spirit, Opportunity, Pathfinder and Viking 1 landing sites indicate that soil chemistry from widely separated locations is consistent with the low-pH, low fluid to rock ratio alteration relationships developed for Gusev rocks. Soils are affected principally by mobility of FeO and MgO, consistent with alteration of olivine-bearing basalt and subsequent precipitation of FeO and MgO bearing secondary minerals as the primary control on soil geochemistry.

Hurowitz, J. A.↗

Role of pH on the stress corrosion cracking of titanium alloys

Stress corrosion cracking (SCC) experiments were conducted on Ti-8-1-1 wire specimens in hydrochloric and sulfuric acids of variable pH in order to determine the effect of pH on the susceptibility to cracking. The alloy exhibited increasing susceptibility with decreasing pH. By varying the applied potential, it was observed that susceptibility zones exist both in the cathodic and the anodic ranges. In the cathodic range, susceptibility also increased with decreasing applied potential. Corrosion potential-time data in hydrochloric acid (pH 1.7) and sulfuric acid (pH 1.7) indicate that chloride ions lower the corrosion potential of the specimen which, in turn, increases the susceptibility.

Khokhar, M. I.↗