Wind-induced torsion of parabolic trough collectors in operation

Parabolic trough collector (PTC) systems, a type of concentrating solar power (CSP), use parabolic mirrors to reflect the sun's rays toward an absorber tube to heat the fluid inside. PTCs track the sun throughout the day and are sensitive to angular misalignment, which reduces optical performance. Torsion of the PTC, exacerbated by wind loading, contributes to angular misalignment, which has been quantified by previous studies using numerical simulations and experimental tests. However, angular misalignment due to torsion and wind loading has not yet been studied in an operational plant, which can experience more extreme and variable conditions. This study characterizes the angular misalignment due to torsion at three rows of the Nevada Solar One CSP plant and investigates the influence of wind loading. These findings reveal substantial torsion along the PTC support structure that depends on wind conditions and orientation. Strong winds perpendicular to the PTCs increase the median angular displacement of the outermost row by up to 18 mrad and increase the standard deviation by up to 8 mrad when compared to weak wind conditions. These findings can inform enhanced PTC design, controls and modeling that will improve the performance, reliability and bankability of future CSP plants.

14 SOLAR ENERGY

Design Basis Document / Owner’s Technical Specification for Nitrate Salt Systems in CSP Projects: Volume 1 Specifications for Parabolic Trough Projects, Volume 2 - Specifications for Central Receiver Projects, Volume 3 - Narrative

Design Basis Documents / Owner’s Technical Specifications are developed for parabolic trough and central receiver power plants using nitrate salt as the heat transport fluid and the thermal storage medium. The goals were to 1) distill the successful experience with nitrate salt systems from as many commercial projects as possible, 2) provide technical bases for equipment design/selection that an owner can impose on an EPC contractor, 3) compile this information in one location to provide guidance on salt systems that is as broadly applicable to as many projects as possible, and 4) work toward an industry consensus on a Design Basis Document that reflects the lessons learned from earlier commercial projects. The document allows an owner to provide design guidance, and to impose a minimum set of requirements, above and beyond those in the normal Codes and Standards, on an EPC contractor in an effort to avoid a repeat of past mistakes. If successful, this would allow salt systems to achieve the same levels of reliability and availability as commercial parabolic trough plants using diphenyl oxide / biphenyl (i.e., Dowtherm A, Therminol VP-1) as the heat transfer fluid. The report consists of 3 volumes: • Volume 1 - Specifications for Parabolic Trough Projects • Volume 2 - Specifications for Central Receiver Projects • Volume 3 - Narrative Volumes 1 and 2 include discussions of the following topics: • Plant functional requirements for the salt systems • Plant operating states, and transitions between states, for the salt systems • Risk analysis of the principal salt components • Plant requirements for the salt systems to meet the functional and the operating requirements • Type of specification for the principal salt components: functional; or prescriptive • Current state of the art for salt systems. Volume 3 discusses a number of cases in which the salt equipment at commercial parabolic trough and central receiver projects has not met the projected levels of reliability and availability. Possible reasons for the sources of the problems are discussed, as is a range of possible alternate designs that could avoid the known problems.

14 SOLAR ENERGY

Characterization of wind conditions and impact on wind loading at an operational parabolic trough concentrating solar power plant using LiDAR observations

Wind loading is a major factor influencing the structural design costs of Concentrating Solar Power (CSP) collector systems, including heliostats and parabolic troughs. Traditionally, these designs have been based on wind-tunnel data, which often fail to accurately represent the dynamic effects experienced at full scale. This study presents a first-of-its-kind experimental characterization of wind conditions within an operational parabolic-trough CSP power plant focusing specifically on using lidar observations. The lidar observations give a unique opportunity to provide insights into wind flow conditions deep within the trough arrays. Our results suggest that (1) after being blocked by the first few rows, the wind speed above the troughs recovers to 73% of its inflow magnitude as it flows further over the trough field due to enhanced turbulent mixing and (2) due to the wind speed recovery, troughs in the interior field will likely experience higher shear-induced turning moments compared those at the front. The conclusions from this work stress the importance of better understanding the wind patterns and interior wind loads when designing solar collectors and highlights the need for more interior load measurements in the future field campaigns.

17 WIND ENERGY

Parabolic Trough Collector Cost Update for Industrial Process Heat In The United States

Despite great potential, the worldwide adoption of concentrating solar thermal (CST) collectors for solar industrial process heat (SIPH) is modest. Industrial process heat (IPH) demands for heat and steam are typically below 300 degrees C, where CST collectors can provide the needed heat. Parabolic trough collectors (PTCs) are the most deployed CST technology for SIPH applications. This paper is focused on the United States, and a summary of known operating parabolic trough plants is shown. A previous analysis of a modern PTC in 2016 found that for SIPH applications, the installed solar field cost could be $200/m2 (2016$). Recent advances in PTC design and manufacturing have led to reduced cost per square meter of aperture area, and for a field of 510 solar collector assemblies (SCAs), the installed cost was $120/m2 (2020$). On one hand, the results from this study showed that the solar field cost for large solar fields (510 SCAs or ~804,000 m2) would increase to $184/m2 (2023$) due to post pandemic inflation and increase in metal prices. On the other hand, medium SIPH sized fields (90 SCAs or ~142,000 m2) cost analysis indicated an installed cost could be $197/m2 (2023$). When small SIPH fields (12 SCAs or ~19,000 m2) are considered, this jumps to $297/m2 (2023$). These are cost estimates for the Installed Cost of the solar fields using the United States 2023$ steel prices. When Chinese steel is used for comparison, the installed cost could be between $162 - $210/m2 for the range of SIPH sizes.

concentrating solar thermal

Design Basis Document / Owner’s Technical Specification for Nitrate Salt Systems in CSP Projects (Final Technical Report)

The number of commercial coal, gas, and nuclear projects built over the past 100 years number in the thousands. As such, there is a large database, available to a wide range of commercial engineering contractors, on proven designs. In essence, unsuccessful designs have, through generations of iterations, been identified and then deleted from further consideration. In contrast, the number of commercial parabolic trough projects using nitrate salt for the thermal storage media is perhaps 60. Further, the number of commercial central receiver projects using nitrate salt as the working fluid is on the order of 20, including estimates for China. Given the relative immaturity of salt technology, and commercial pressures to successfully bid new solar projects into a mature electricity market, solar projects often promise more than has been delivered. The Design Basis Document / Owner’s Technical Specification is a first step in the iteration process. The report describes the successful features of commercial projects, outlines a range equipment and system failures in projects that didn’t operate as intended, and provides a draft set of design changes intended to correct the known problems. The product of the study is 3 volumes of technical material; one volume is on parabolic trough technologies; a second is on central receiver technologies, and the third is on potential design changes to parabolic trough and central receiver projects. The 3 volumes, which total some 590 pages, can be found at https://www.solardynllc.com/csp-plant-technologies. One of the principal topics in the report is the use of functional or prescriptive specifications. Functional specifications describe what the equipment needs to do, consistent with the minimum legal requirements of the local jurisdictions. The details of how this is to be accomplished is developed by the engineering contractor. Prescriptive specifications, which are developed by the Owner, prescribe to the engineering contractor how the functional requirements are to be met. This arrangement ensures that the favorable experience from a previous project is repeated. One example is the design code for the hot salt tank in central receiver projects. The closest design basis is API Standard 650 Welded Steel Tanks for Oil Storage. However, the maximum design temperature in API 650 is 260 °C. As such, solar projects have typically adopted a hybrid Code approach, in which allowable material stresses are taken from ASME Section II Materials. Further, since the tanks experience daily changes in temperature and in (static) pressure, and since portions of the tank can operate at stresses beyond the elastic range, the low cycle fatigue life of the tank is conducted using the rules of Section VIII Division 2. However, in a recent study by NREL, the principal damage mechanism was identified as creep rather than fatigue. Further, design stresses permitted under Section VIII Division 2, corresponding to a fatigue life of 30 years, result in projected creep lifetimes of only 2 to 5 years. An alternate design approach, prescribed by the Owner, would be based on Code sections intended for high temperature service in the creep regime. A candidate is Section III Division 5. Granted, this is a nuclear code section, and it’s use would not likely be mandated by local jurisdictions. However, the effects of creep have been deemed to be of sufficient importance that one nuclear project developer, and one central receiver project developer, have stipulated in the tank design specification that the equipment be designed to the requirements of Section III Division 5.

14 SOLAR ENERGY

Wind Loading on CSP Collectors

The project significantly enhanced the community's understanding of the fundamental physics drivers underlying the wind-loading experienced by concentrating solar power (CSP) collector structures (i.e., parabolic troughs and heliostats) as well as their support structures. This project had two overarching objectives: (1) detailed measurements to characterize the prevailing wind conditions and resulting operational loads on collector structures, and (2) development and validation of a computationally efficient, high-fidelity modeling tool capable of predicting wind-loading in deep-array installations. Over three years, we conducted comprehensive at-scale field measurements of the atmospheric turbulent wind conditions, and the resulting wind loads on parabolic troughs and heliostats. Two at-scale measurement campaigns yielded first-of-its-kind, high-resolution, long-term datasets that are used to characterize the complex flow field and wind loading on parabolic-troughs and heliostats in operational power plants. The high-resolution measurements collected during these campaigns were used to validate the high-fidelity computational models developed at NREL. These open-source computationally efficient models were shown to be accurate in predicting wind-driven loads on collectors without the need for a large supercomputer.

14 SOLAR ENERGY

Studying Wind Loading on CSP Collectors to Improve Performance and Reliability

Electricity generation through Concentrating Solar-thermal Power (CSP) adds the advantage of thermal energy storage and heat production. CSP collector costs constitute nearly one-third of total plant costs. Managing wind loading, especially dynamic wind loading caused by the turbulent wind flow, is a significant design challenge. Traditional collector designs rely on wind tunnel experiments and numerical simulations, which do not fully capture dynamic effects. Here, we provide an overview of NREL's activities on wind loading on CSP collectors, aiming to improve their reliability and cost-efficiency. We present insights from field measurements at operational parabolic trough and power-tower CSP plants. Over two years, we measured turbulent wind fields and resulting structural loads in a parabolic trough plant, revealing wind, turbulence, and collector field interactions. Similar measurements are ongoing at the Crescent Dunes heliostat field. These campaigns show how atmospheric turbulence, wind direction, and collector orientation affect dynamic wind loading. Upwind collector structures can generate turbulent structures, causing fluctuating loads at downstream collectors, impacting fatigue lifetime and optical efficiency. Preliminary results indicate that interior collectors experience higher turning moments than those at the edges, suggesting higher drive wear. At Crescent Dunes, we use instrumented heliostats at the field's edge and interior to study the translation of turbulent wind to dynamic structural loads. The campaign is still ongoing, and we will present first findings. Another focus of our work is tying the experimental wind loading findings to optical performance of the collectors, using simulation tools. For example, we derive torsional errors of the parabolic troughs - the angular offset from the sun position along a collector row. This error is impacted by wind-induced mirror deformations. Future work will focus on continuing the measurement efforts and combining them with computational fluid dynamic simulations. By providing detailed field measurements and validated models, our efforts aim to enhance understanding of wind loading on CSP collectors, improving their structural integrity and optical performance.

CSP

Measurement of Wind Loading on Heliostats at the Crescent Dunes Power Plant: An Overview

The cost of solar collectors constitutes almost one third of the total cost of a CSP plant. One of the ongoing challenges in the design of these collectors is wind loading on mirrors, support structures, and drives. A particular challenge is dynamic wind loading, caused by the turbulent wind flow. To date, the design of solar collector structures has relied on wind tunnel experiments and numerical simulations that do not entirely capture the dynamic effects observed at scale. The CSP industry has shown increased interest in validating the idealized assumptions with measurements obtained in operational settings to improve wind load assumptions and increase reliability and cost-efficiency of the collector design. Further, performance models need realistic assumptions about wind loading and its impact on optical performance. In a parabolic trough field campaign, NREL successfully collected a wealth of long-term, high-resolution wind and loads data [2], that are publicly available and that can be used for the above-mentioned purposes. Heliostats are impacted differently by wind than parabolic troughs, due to their different shape, size, and field layout. To study the impact of wind and turbulence on heliostats, we initiated another field campaign in an operational power- tower plant, Crescent Dunes, in Nevada, USA. In this work, we present an overview of the measurements, first results, and potential implications of wind driven loads on Heliostats.

concentrated solar power

Energy and Environmental Analyses of a Solar–Gas Turbine Combined Cycle with Inlet Air Cooling

Sensitivity to ambient air temperatures, consuming a large amount of fuel, and wasting a significant amount of heat dumped into the ambient atmosphere are three major challenges facing gas turbine power plants. This study was conducted to simultaneously solve all three aforementioned GT problems using solar energy and introducing a new configuration that consists of solar preheating and inlet-air-cooling systems. In this study, air was preheated at a combustion chamber inlet using parabolic trough collectors. Then, inlet air to the compressor was cooled by these collectors by operating an absorption cooling cycle. At the design point conditions, this novel proposed integration resulted in a 6.87% relative increase in generated power and a 10.53% relative decrement in fuel consumption, achieving a 19.45% relative increment in the plant’s thermal efficiency. This was accompanied by a reduction of 0.026 kg/s, 4.2 kg/s, and 0.278 kg/s in CO 2 , CO, and NOx emissions, respectively. Finally, spider diagrams were employed to assess the impact of the operating parameters on the overall system’s performance and its associated environmental implications.

14 SOLAR ENERGY

Assessment of the polygeneration approach in wastewater treatment plants for enhanced energy efficiency and green hydrogen/ammonia production

Wastewater treatment plants (WWTPs) offer opportunities to optimize resource utilization and enhance energy efficiency. Here, this study provides a comprehensive analysis of using the polygeneration approach in WWTPs to reduce grid energy dependence, optimize energy distribution, and utilize surplus energy for hydrogen (H 2 ) and ammonia (NH 3 ) production. Several models were employed, including photovoltaic (PV) cells, parabolic trough collectors (PTCs), steam methane reforming, and polymer electrolyte membranes, to assess the feasibility of this approach. Three scenarios were evaluated and compared: Scenario 1 (Baseline) represents the current situation, Scenario 2 maximizes the Net Present Value (NPV), and Scenario 3 minimizes NH 3 production costs. Real data from As-Samra WWTP in Jordan was used to accurately assess the feasibility of each scenario. The results show that Scenario 2 offers the highest profitability and efficiency, with a NPV of 87.48 million USD and an annual NH 3 production of 15,417 tons, reducing both grid dependency and biogas fuel consumption. Both Scenarios 2 and 3 demonstrate the ability to meet thermal demands efficiently while generating significant revenue from NH 3 production. Scenario 3, in particular, achieves competitive H 2 and NH 3 production costs. Environmentally, Scenario 2 significantly reduces annual greenhouse gas emissions by 12.66 kilotons of CO 2eq , with near-zero carbon intensity for thermal energy due to solar reliance. In conclusion, the polygeneration approach offers a promising pathway for WWTPs to achieve greater sustainability, economic gains, and reduced environmental impact, providing valuable insights for decision-makers.

42 ENGINEERING

A polarimetry-based field-deployable non-interruptive mirror soiling detection method

The soiling level of heliostat mirrors in Concentrated Solar Power (CSP) fields is one of the key factors that significantly influences optical efficiency. State-of-the-art methods of monitoring heliostats soiling levels still face various challenges, including slow speed, labor-intensive operations, resolution and accuracy constraints or interruptions to solar field operations. Here, we present a rapid, cost-effective, and non-intrusive method for mirror soiling detection based on polarimetric imaging, referred to as Polarimetric Imaging-based Mirror Soiling (PIMS). The compact PIMS device is designed for integration with unmanned aerial vehicles (UAVs), enabling rapid, large-area assessments of heliostat mirrors for efficient soiling detection. Our method utilizes the correlation between the Degree of Linear Polarization (DoLP) and surface soiling level based on Mie scattering theory and Monte Carlo simulations. Field deployment of the PIMS method requires minimal device installation, and its UAV-based operation allows for soiling detection without interrupting plant activities. The PIMS method holds the potential for mirror soiling detection across various concentrated solar power (CSP) plants and can be further adapted for other types of solar fields, such as parabolic trough systems.

CSP Field

Wind Conditions for Solar Energy Facility Design Based on Field Measurements at Nevada Solar One

This study characterises near-surface wind conditions at the Nevada Solar One (NSO) concentrated solar power plant using two years of measurements from a 15-m mast located 30 m west of the solar arrays. The surrounding terrain is fairly flat within 3 km, but nearby solar photovoltaic (PV) and concentrated solar power (CSP) installations introduce strong directional wind inhomogeneity, which motivates a sector-based analysis that distinguishes undisturbed inflow from waked flow. The analysis uses data from three sonic anemometers to assess whether turbulence in the surface layer can be represented as Gaussian and whether standard surface-layer scaling remains valid below 10 m height. The roughness length and displacement height are estimated for twelve directional sectors under near-neutral wind conditions, and all three velocity components show departures from Gaussian behaviour. Spectral analysis indicates that the turbulence contains low-frequency fluctuations with amplitudes higher than those predicted by standard models such as the Kaimal model or the Simiu and Scanlan model. The study introduces a new turbulence spectral model based on the eddy-surface-layer framework to better represent near-surface wind turbulence. The analysis further quantifies the influence of the surrounding power plants on mean wind profiles, one-point spectra, and vertical coherence for all velocity components. The solar collector arrays located 30 m east of the mast significantly modify the turbulence structure, whereas PV installations situated a few hundred metres away have only a limited influence on the turbulence measured at the mast. These findings highlight the limitations of conventional turbulence models for near-surface wind over solar infrastructure and provide improved parameterisations to support the structural design. The implications for the structural response of parabolic troughs and PV modules to such turbulence remain uncertain and require further investigation.

14 SOLAR ENERGY

FY2023 NSTTF Annual Report

The National Solar Thermal Test Facility (NSTTF) is a DOE Core Capability and Technology Deployment Center located in Albuquerque, NM. It is operated by Sandia National Laboratories (Sandia) for the U.S. Department of Energy (DOE). The NSTTF is the only multi-mission, multi-use, multi-story test facility of its type in the United States. The NSTTF was founded in 1978 and began testing with high heat flux that same year. Over the past 45 years, the NSTTF has been at the forefront of the research, design, fabrication, and testing of many of the critical Concentrating Solar Power (CSP) technologies. These technologies have allowed costs to be dramatically reduced from over $\$ $0.40 /kWh to $\$$0.12 /kWh since the conception of this renewable energy technology. The NSTTF has worked to make the Solar Energy Generating Systems (SEGS) parabolic trough plants successful, while also working with the Solar One and Solar Two facilities for successful implementation. Over the four decades since its founding, the mission of the NSTTF has grown to include new receiver technologies, like our generation 3 falling particle system (G3P3 Tower), optical metrology techniques like SOFAST, molten salt testing, thermal energy storage, solar thermal chemistry, and more. We continue to expand our capabilities in pursuit of the DOE SETO mission and the DOE SunShot 2030 goals: unsubsidized LCOE of $\$$0.05/kWh for CSP that includes 12 or more hours of thermal energy storage. To support both the DOE SETO mission and support the CSP sector as a whole, we are working to develop our operations and maintenance framework to provide a world class testing facility in support of our technological achievements. To accomplish both of these missions, the NSTTF draws on the decades of experience and expertise of our staff along with the world-class facilities at Sandia National Laboratories to further the science of concentrated solar thermal technologies in diverse applications. We remain a trusted partner for high-quality and impactful research in both fundamental and applied arenas. We are able to provide our partners with both one-of-a-kind testing platforms as well as world-class analytics.

14 SOLAR ENERGY

Analysis of Molten Salt Thermal Energy Storage Tank Sizing and Preheating

Molten Salt Thermal energy storage (TES) is essential for concentrating solar power (CSP) plants, enhancing their capacity factor and dispatchability to ultimately reduce electricity costs. This technology is becoming more important for other technologies including nuclear power, thermal-electrical storage, and concentrating solar thermal (CST). While molten salt TES tanks have been successfully deployed in lower-temperature parabolic-trough plants, the current state-of-the-art central receiver systems operating at temperatures up to 565 degrees Celsius have experienced costly and frequent failures. These failures are associated with the immaturity of the technology and problems in tank design, fabrication, commissioning and, sometimes, aggressive operation. A primary contributing factor is the absence of a dedicated technical standard for high-temperature molten nitrate TES tanks; designers must currently rely on existing codes like API 650 and ASME Section II, which are insufficient because they fail to account for the unique demands of high temperatures, thermal cycling, and transient conditions.

25 ENERGY STORAGE

First Solar Thermal Energy Planner (STEP 1) and Nationwide Industrial Heat and Power Analysis

The First Solar Thermal Energy Planner (STEP 1) and Nationwide Industrial Heat and Power Analysis (aka the STEP 1 Project or the Project) aimed to (1) developed a brand-new web tool that could provide decision support through free, rapid techno-economic analysis of behind-the-meter solar+storage systems for industrial process heat and (2) conduct high-level analyses of the cost-competitiveness of the same systems across the US in key sectors. The STEP 1 web tool collects key location, land availability, thermal load profile, proccess heat temperature and media, and other key parameters through an easy-to-use user interface (UI). The UI was designed to meet the user at their level of understanding by minimizing the number of required inputs as much as possible while including options for more nuanced inputs if the user desires. STEP 1 advises users on which solar thermal tehcnologies that could fit their needs based on the inputs provided (namely process media and temperature). The tool can model a wide range of solar thermal technologies including flat plate collectors, evacuated tubes, parabolic troughs, linear Fresnel, and molten salt towers all with corresponding thermal energy storage (TES) - solar PV with resistive heating and TES is also included. Once the parameters are collected, a nominal thermal energy production profile for the facility's location is generated using NREL's System Advisory Model (SAM) and then passed to a modified version of NREL's REopt platform to optimize the size (capacity) and dispatch of the solar+storage system to minimize lifecycle costs subject to energy balance, fuel and electricity rates, emission reductions goals, and other constraints. This entire process takes less than 20 minutes, is completely free, requires zero coding skills, and provides the user with a high-level assessment on the techno-economic feasability of deploying solar+storage systems for their energy needs. In addition to the development of the STEP 1 web tool, the project completed two complementary analyses focused on leveraging the backend code of STEP 1, public industrial facility locations and fuel consumption data, and key sector information to assess the economic opportunity of reducing fuel costs at various levels of capacity factor around the US. Both analyses found that there are key markets, locations, industrial sectors (namely food and beverage), and degrees of offset where solar thermal technologies could be cost-effectively deployed, highlighting a key market entry point for these technologies, and assessing deployment potential. In summary, the STEP 1 project improved the opportunities for solar+storage systems to expand into the industrial process heat market through breaking down barriers to assessing these technologies.

14 SOLAR ENERGY