Search NASA⌕ Search

SEARCH · Search NASA

Results for “parametric pumping”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Magnonic spontaneous oscillation induced by parametric pumping

Spontaneous dynamic systems have attracted significant attention for their rich underlying physics such as phase-locking and synchronization. In this work, we report a new mechanism of generating magnetic spontaneous oscillation via parametric pumping. By applying a pump tone to excite propagating spin waves in a yttrium iron garnet delay line, four-wave mixing converts the pump mode into two phase-autonomous propagating magnon modes, i.e. a spontaneous mode with nearly twice the wavenumber of the pump mode and an idler mode with nearly zero wavenumber. This allows us to reliably generate ultrasharp spin wave dynamics with broad frequency tunability from the pump and magnetic field. We show that the spontaneous mode can be phase-locked to a probe tone, similar to an auto-oscillator. Furthermore, the spontaneous dynamics can be used to implement a high-gain magnonic parametric amplifier with a gain up to 40 dB. Our results open a new avenue for studying nonlinear magnonics and synchronization physics in propagating magnon geometry and for developing new magnonic devices.

Li, Yi↗

Antiferromagnetic Parametric Resonance Driven by Voltage-Controlled Magnetic Anisotropy

Voltage-controlled magnetic anisotropy (VCMA) is a low-energy alternative to manipulate the ferromagnetic state, which has been recently also considered in antiferromagnets (AFMs). Here, we theoretically demonstrate that VCMA can be used to excite linear and parametric resonant modes in easy-axis AFMs with perpendicular anisotropy, thus opening the way for an efficient electrical control of the Néel vector and for the detection of high-frequency dynamics. Our work leads to two key results: (i) VCMA parametric pumping experiences the so-called “exchange enhancement” of the coupling efficiency and, thus, is 1–2 orders of magnitude more efficient than microwave magnetic fields or spin-orbit torques, and (ii) it also allows for zero-field parametric resonance, which cannot be achieved by other parametric pumping mechanisms in AFMs with an out-of-plane easy axis. Therefore, we demonstrate that VCMA parametric pumping is the most promising method for coherent excitation and manipulation of AFM order in perpendicular easy-axis AFMs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dynamic magnetic phase transition induced by parametric magnon pumping

Uncovering pathways to optically drive magnetic order-disorder transitions on ultrashort timescales can lead to the realization of novel out-of-equilibrium quantum phenomena. A long-sought pathway is to directly excite a highly nonthermal energy-momentum distribution of magnons, bypassing both charge and lattice degrees of freedom. However, this remains elusive owing to the weak coupling and large momentum mismatch between photons and magnons. Here we demonstrate strong parametric excitation of magnons across the entire Brillouin zone of the antiferromagnetic insulator Sr 2 ⁢Cu 3 ⁢O 4 ⁢Cl 2 by periodically modulating the superexchange interaction with the electric field of light. The excitation efficiency is greatly enhanced by tuning to the van Hove singularity in the magnon spectrum, sufficient to transiently collapse the antiferromagnetic state using a pulsed laser field of 10 9 V/m. The order parameter recovery timescale increases by over 1000 times as a function of excitation density, reflecting a crossover from high- to low-energy magnon dominated decay dynamics. This electric-field induced parametric magnon pumping mechanism is applicable to a broad range of magnetic insulators and opens up the possibility of dynamically engineering magnon distributions by design.

antiferromagnetism↗

Toward Ultra‐High‐Quality‐Factor Wireless Masing Magnetic Resonance Sensing

It has recently been shown that a bolus of hyperpolarized nuclear spins can yield stimulated emission signals similar in nature to maser signals, potentially enabling new ways of sensing hyperpolarized contrast media, including most notably [1- 13 C]pyruvate that is under evaluation in over 50 clinical trials for metabolic imaging of cancer. The stimulated NMR signal emissions lasting for minutes do not require radio-frequency excitation, offering unprecedented advantages compared to conventional MR sensing. However, creating nuclear spin maser emission is challenging in practice due to stringent fundamental requirements, making practical in vivo applications hardly possible using conventional passive MR detectors. Here, in this study, we demonstrate the utility of a wireless NMR maser detector, the quality factor of which was enhanced 22-fold (to 1,670) via parametric pumping. This active-feedback technique breaks the intrinsic fundamental limit of NMR detector circuit quality factor. We show the use of parametric pumping to reduce the threshold requirement for inducing nuclear spin masing at 300 MHz resonance frequency in a preclinical MRI scanner. Indeed, stimulated emission from hyperpolarized protons was obtained under highly unfavorable conditions of low magnetic field homogeneity (T 2 * of 3 ms). Greater gains of the quality factor of the MR detector (up to 1 million) were also demonstrated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Non-degenerate parametric mixing and Q-enhancement in ALN Lamb wave resonator

In this Letter, we explore a non-degenerate phase independent parametric quality factor (Q)-enhancement technique for aluminum nitride (AlN) Lamb wave resonators. Unlike other active Q-enhancement techniques which require precise phase control of the electronic feedback loop, this technique is implemented by parametrically pumping AlN material stiffness to realize a negative resistance seen at the signal path. The negative resistance is dependent on the nonlinear material modulation and multi-resonance coupling in the device. A nonlinear circuit model is developed to simulate the parametric coupling of each resonance and extract the nonlinearity of AlN from experimental data. With proper pump frequency and pump power, the device quality factor is boosted in both simulation and experiment. The demonstrated Q-enhancement method is simple to implement and can be applied to other types of resonators that have nonlinear behavior and support multi-resonance operation.

42 ENGINEERING↗

Experimental generation of polarization entanglement from spontaneous parametric down-conversion pumped by spatiotemporally highly incoherent light

Here, we investigate the cross influence of the pump coherence on the entanglement produced from spontaneous parametric down-conversion (SPDC) in different degrees of freedom (DOFs). We experimentally demonstrate the generation of polarization entanglement from SPDC pumped by a spatiotemporally highly incoherent (STHI) light-emitting diode. Our quantum state tomography measurements using multimode collection fibers to avoid postselection yield a two-qubit state with the concurrence of 0.531 ± 0.006 and purity of 0.647 ± 0.005, in excellent agreement with our theoretically predicted concurrence of 0.552 and purity of 0.652. We find that using an STHI pump reduces the entanglement and purity of the output polarization two-qubit state due to a coupling between the spatiotemporal and polarization DOFs introduced by the birefringence and dispersion of the nonlinear crystal. The viability of SPDC with STHI pumps is important for two reasons: (i) STHI sources are ubiquitous and available at a wider range of wavelengths than lasers, and (ii) the generated STHI polarization-entangled two-photon states could potentially be useful in long-distance quantum communication schemes due to their robustness to scattering.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Parametric Studies of Heat Pump Water Heater Using Low GWP Refrigerants

A storage heat pump water heater (HPWH) comprises a vapor compression system and a hot water tank. It can lead to more than 70% energy saving, compared with electric resistance heating. HPWH usually uses a wrapped-tank coil as the water heater. The wrapped coil has a strong interaction with the water tank and impose a new challenge for the engineering design and simulation study. Based on the US DOE/ORNL Heat Pump Design Model (HPDM), i.e., a public-domain, component-based thermal system modelling platform, a segment-to-segment wrapped-tank coil model coupled with a one-dimensional stratified water tank model were developed, which facilitates modeling and design HPWHs having various configurations and components. Additionally, the hardware-based design model was used to evaluate refrigerants having lower global warming potentials to replace R-134a, including R-1234yf, R-1234ze, R-290, R-513A and R-450A, when effects of compressor size, refrigerant charge on 24-hour uniform energy factor (UEF) and first-hour rating (FHR) were investigated.In the drop-in replacements, R-1234ze achieved the best UEF, and R-290 resulted in the lowest UEF. When downsizing the compressor to maximize the UEFs, the UEFs of R-134a, R-290, R1234yf, R-450A and R-513A ascended to the range of 4.4 to 4.53, with R-513A having the highest UEF. The R-1234ze ended up having the lowest UEF of 4.27. Refrigerants having larger volumetric vaporization heat led to higher FHRs if using the fixed-size compressor, that R-290 resulted in the highest FHR.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A physics-based parametric regression approach for feedwater pump system diagnosis

Here in this paper, we assessed the performance of a model-based approach for fault diagnosis of a nuclear power plant feedwater pump system. Physics-based models were constructed to monitor the performance of the system components. Plant data were used for the calibration of the models and subsequently in the diagnosis of abnormal events. We considered two real-time events representing scenarios of a pump fault and component performance degradation. The two events were correctly diagnosed, and the results demonstrated the high detection sensitivity of the physics-based models. Various sensor fault scenarios were simulated to show the capability of the approach to detect and uniquely identify sensor faults. Results for a scenario in which the plant operated in flexible power mode also showed that the diagnostic approach is insensitive to changes of operating conditions, which is one of the advantages of the model-based approach using physics-based models over purely data-driven approach.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Soft x-ray high-harmonic generation in an anti-resonant hollow core fiber driven by a 3 μ m ultrafast laser

High-harmonic upconversion driven by a mid-infrared femtosecond laser can generate coherent soft x-ray beams in a tabletop-scale setup. Here, we report on a compact ytterbium-pumped optical parametric chirped pulse amplifier (OPCPA) laser system seeded by an all-fiber front-end and employing periodically poled lithium niobate (PPLN) nonlinear media operated near the pulse fluence limits of current commercially available PPLN crystals. The OPCPA delivers 3 µm wavelength pulses with 775 µJ energy at 1 kHz repetition rate, with transform-limited 120 fs pulse duration, diffraction-limited beam quality, and ultrahigh 0.33% rms energy stability over >18 h. Using this laser, we generate soft x-ray high harmonics (HHG) in argon gas by focusing into a low-loss, high-pressure gas-filled anti-resonant hollow core fiber (ARHCF), generating coherent light at photon energies up to the argon L-edge (250 eV) and carbon K-edge (284 eV), with high beam quality and ∼1% rms energy stability. This work demonstrates soft x-ray HHG in a high-efficiency guided-wave phase matched geometry, overcoming the high losses inherent to mid-IR propagation in unstructured waveguides, or the short interaction lengths of gas cells or jets. The ARHCF can operate in the long term without damage and with the repetition rate, stability, and robustness required for demanding applications in spectromicroscopy and imaging. Finally, we discuss routes for further optimizing the soft x-ray HHG flux by driving He at higher laser intensities using either the signal (1.5 μm) or idler wavelengths (3 μm).

Femtosecond lasers↗

Single-mode squeezed-light generation and tomography with an integrated optical parametric oscillator

Quantum optical technologies promise advances in sensing, computing, and communication. A key resource is squeezed light, where quantum noise is redistributed between optical quadratures. We introduce a monolithic, chip-scale platform that exploits the χ (2) nonlinearity of a thin-film lithium niobate (TFLN) resonator device to efficiently generate squeezed states of light. Our system integrates all essential components—except for the laser and two detectors—on a single chip with an area of one square centimeter, reducing the size, operational complexity, and power consumption associated with conventional setups. Using the balanced homodyne measurement subsystem that we implemented on the same chip, we measure a squeezing of 0.55 decibels and an anti-squeezing of 1.55 decibels. We use 20 milliwatts of input power to generate the parametric oscillator pump field by using second harmonic generation on the same chip. Our work represents a step toward compact and efficient quantum optical systems posed to leverage the rapid advances in integrated nonlinear and quantum photonics.

97 MATHEMATICS AND COMPUTING↗

Sub-two-cycle gigawatt-peak-power LWIR OPA for ultrafast nonlinear spectroscopy of condensed state materials

The application of high-power, few-cycle, long-wave infrared (LWIR, 8–20 µm) pulses in strong-field physics is largely unexplored due to the lack of suitable sources. However, the generation of intense pulses with >6 µm wavelength range is becoming increasingly feasible with the recent advances in high-power ultrashort lasers in the middle-infrared range that can serve as a pump for optical parametric amplifiers (OPA). Here we experimentally demonstrate the feasibility of this approach by building an OPA pumped at 2.4 µm that generates 93 µJ pulses at 9.5 µm, 1 kHz repetition rate with sub-two-cycle pulse duration, 1.6 GW peak power, and excellent beam quality. The results open a wide range of applications in attosecond physics (especially for studies of condensed phase samples), remote sensing, and biophotonics.

Leshchenko, Vyacheslav (ORCID:0000000199708559)↗

Flux-pumped impedance-engineered broadband Josephson parametric amplifier

Broadband quantum-limited amplifiers play a critical role in the single-shot readout of superconducting qubits, but a popular implementation, the traveling wave parametric amplifier, involves a complex design and fabrication process. Here, we present a simple design for a Josephson parametric amplifier, using a lumped element resonator comprising a superconducting quantum interference device whose useful bandwidth is enhanced with an on-chip impedance-matching circuit. Additionally, we demonstrate a flux-coupling geometry that maximizes the coupling to the Josepson loop and minimizes spurious excitation of the amplifier resonant circuit. The amplifier, which operates in a flux-pumped mode, is demonstrated with a power gain of more than 20dB over a bandwidth of about 300MHz, where approximate noise measurements indicate quantum-limited pehrformance. A procedure is given for optimizing the bandwidth for this kind of amplifier, using a linearized circuit simulation while minimizing non-linearities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of pump-to-signal noise transfer in two-stage ultra-broadband optical parametric chirped-pulse amplification

In optical parametric chirped-pulse amplification (OPCPA), pump temporal intensity modulation is transferred to the chirped-signal spectrum via instantaneous parametric gain and results in contrast degradation of the recompressed signal. We investigate, for the first time to our knowledge, the pump-to-signal noise transfer in a two-stage ultra-broadband OPCPA pumped by a single laser and show the dependence of pump-induced signal noise, characterized both before and after pulse compression, on the difference in pump-seed delay in the two stages. We demonstrate an up-to-15-dB reduction of the pump-induced contrast degradation via pump-seed delay optimization. Experiments and simulations show that, even when parametric amplifiers are operated in saturation, the pump-seed delay can be used to minimize the pump-induced contrast degradation that is attributed largely to the noises from the unsaturated edges of the pulse and that of the beam.

47 OTHER INSTRUMENTATION↗

Latched detection of zeptojoule spin echoes with a kinetic inductance parametric oscillator

When strongly pumped at twice their resonant frequency, nonlinear resonators develop a high-amplitude intracavity field, a phenomenon known as parametric self-oscillations. The boundary over which this instability occurs can be extremely sharp and thereby presents an opportunity for realizing a detector. Here, we operate such a device based on a superconducting microwave resonator whose nonlinearity is engineered from kinetic inductance. The device indicates the absorption of low-power microwave wavepackets by transitioning to a self-oscillating state. Using calibrated pulses, we measure the detection efficiency to zeptojoule energy wavepackets. We then apply it to measurements of electron spin resonance, using an ensemble of 209 Bi donors in silicon that are inductively coupled to the resonator. We achieve a latched readout of the spin signal with an amplitude that is five hundred times greater than the underlying spin echoes.

42 ENGINEERING↗

Noncolinear optical parametric oscillator for broadband nanosecond pulse-burst CARS diagnostics in gases

We report demonstration of broadband nanosecond coherent anti-Stokes Raman scattering (CARS) using a burst-mode-pumped noncolinear optical parametric oscillator (NOPO) has been achieved at a pulse repetition rate of 40 kHz. The NOPO is pumped with the 355-nm output of a burst-mode Nd:YAG laser at 50 mJ/pulse for 45 pulses and produces an output centered near 607 nm, with a bandwidth of 370 cm –1 at energies of 5 mJ/pulse. A planar BOXCARS phase matching scheme uses the broadband NOPO output as the Stokes beam and the narrowband 532-nm burst-mode output for the two CARS pump beams for single-laser-shot nitrogen thermometry in near adiabatic H 2 /air flames at temperatures up to 2200 K.

47 OTHER INSTRUMENTATION↗

Complete Frequency-Bin Bell Basis Synthesizer

Here we report the experimental generation of all four frequency-bin Bell states in a single versatile setup via successive pumping of spontaneous parametric down-conversion with single and dual spectral lines. Our scheme utilizes intensity modulation to control the pump configuration and offers turn-key generation of any desired Bell state using only off-the-shelf telecommunication equipment. We employ Bayesian inference to reconstruct the density matrices of the generated Bell states, finding fidelities ≥97% for all cases. Additionally, we demonstrate the sensitivity of the frequency-bin Bell states to common-mode and differential-mode temporal delays traversed by the photons comprising the state—presenting the potential for either enhanced resolution or nonlocal sensing enabled by our complete Bell basis synthesizer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗