Search NASA⌕ Search

SEARCH · Search NASA

Results for “parasitics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

From Parasite Encounter to Infection: Multiple-Scale Drivers of Parasite Richness in a Wild Social Primate Population

Host parasite diversity plays a fundamental role in ecological and evolutionary processes, yet the factors that drive it are still poorly understood. A variety of processes, operating across a range of spatial scales, are likely to influence both the probability of parasite encounter and subsequent infection. Here, we explored eight possible determinants of parasite richness, comprising rainfall and temperature at the population level, ranging behavior and home range productivity at the group level, and age, sex, body condition, and social rank at the individual level. We used a unique dataset describing gastrointestinal parasites in a terrestrial subtropical vertebrate (chacma baboons, Papio ursinus), comprising 662 faecal samples from 86 individuals representing all age-sex classes across two groups over two dry seasons in a desert population. Three mixed models were used to identify the most important factor at each of the three spatial scales (population, group, individual); these were then standardised and combined in a single, global, mixed model. Individual age had the strongest influence on parasite richness, in a convex relationship. Parasite richness was also higher in females and animals in poor condition, albeit at a lower order of magnitude than age. Finally, with a further halving of effect size, parasite richness was positively correlated to day range and temperature. These findings indicate that a range of factors influence host parasite richness through both encounter and infection probabilities, but that individual-level processes may be more important than those at the group or population level.

Benavides J. A.↗

Reduction of parasitic lasing

A technique was developed which carefully retro-reflects precisely controlled amounts of light back into a laser system thereby intentionally forcing the laser system components to oscillate in a new resonator called the parasitic oscillator. The parasitic oscillator uses the laser system to provide the gain and an external mirror is used to provide the output coupling of the new resonator. Any change of gain or loss inside the new resonator will directly change the lasing threshold of the parasitic oscillator. This change in threshold can be experimentally measured as a change in the absolute value of reflectivity, provided by the external mirror, necessary to achieve lasing in the parasitic oscillator. Discrepancies between experimental data and a parasitic oscillator model are direct evidence of optical misalignment or component performance problems. Any changes in the optical system can instantly be measured as a change in threshold for the parasitic oscillator. This technique also enables aligning the system for maximum parasitic suppression with the system fully operational.

Storm, Mark E.↗

An experimental investigation of parasitic microstrip arrays

The characteristics of a parasitic microstrip antenna array with a center-fed patch are experimentally investigated. The parasitic array is composed of identical parasitic patches which are symmetrically arranged and electromagnetically coupled to a center-fed patch. The shape and dimensions of the parasitic patches and their positions relative to the center-fed patch are parameters in the study. To show mutual coupling effects between radiating and nonradiating edges of adjacent patches, the impedance and radiation characteristics of a three-element parasitic array excited with (0.1) mode are examined, and compared to that of a single patch. Experimental data indicate that the presence of parasitic patches has significant effects upon the gain, resonant frequency, and impedance bandwidth of the array.

Lee, Richard Q.↗

Parasitic current collection by PASP Plus solar arrays

Solar cells at potentials positive with respect to a surrounding plasma collect electrons. Current is collected by the exposed high voltage surfaces: the interconnects and the sides of the solar cells. This current is a drain on the array power that can be significant for high-power arrays. In addition, this current influences the current balance that determines the floating potential of the spacecraft. One of the objectives of the Air Force (PL/GPS) PASP Plus (Photovoltaic Array Space Power Plus Diagnostics) experiment is an improved understanding fo parasitic current collection. We have done computer modeling of parasitic current collection and have examined current collection flight data from the first year of operations. Prior to the flight we did computer modeling to improve our understanding of the physical processes that control parasitic current collection. At high potentials, the current rapidly rises due to a phenomenon called snapover. Under snapover conditions, the equilibrium potential distribution across the dielectric surface is such that part of the area is at potentials greater than the first crossover of the secondary yield curve. Therefore, each incident electron generates more than one secondary electron. The net effect is that the high potential area and the collecting area increase. We did two-dimensional calculations for the various geometries to be flown. The calculations span the space of anticipated plasma conditions, applied potential, and material parameters. We used the calculations and early flight data to develop an analytic formula for the dependence of the current on the primary problem variables. The analytic formula was incorporated into the EPSAT computer code. EPSAT allows us to easily extend the results to other conditions. PASP Plus is the principal experiment integrated onto the Advanced Photovoltaic and Electronics Experiments (APEX) satellite bus. The experiment is testing twelve different solar array designs. Parasitic current collection is being measured for eight of the designs under various operational and environment conditions. We examined the current collected as a function of the various parameters for the six non-concentrator designs. The results are similar to those obtained in previous experiments and predicted by the calculations. We are using the flight data to validate the analytic formula developed. The formula can be used to quantify the parasitic current collected. Anticipating the parasitic current value allows the spacecraft designer to include this interaction when developing the design.

Davis, Victoria Ann↗

Effect of parasitic plasma currents on solar-array power output

Solar-array voltage-current curves are calculated by assuming the existence of parasitic loads that consist of local currents of charged particles collected by the array. Three cases of interest are calculated to demonstrate how the distribution and magnitude of parasitic currents affect output. Solar array performance degradation became significant when the total parasitic current plus the load current exceeded the short-circuit current. Approximate graphical methods were useful for many applications. Power loss, which was calculated by summing the product of parasitic current and the local potential, underestimated the loss in maximum power.

Domitz, S.↗

Constant current loop impedance measuring system that is immune to the effects of parasitic impedances

A constant current loop measuring system is provided for measuring a characteristic of an environment. The system comprises a first impedance positionable in the environment, a second impedance coupled in series with said first impedance and a parasitic impedance electrically coupled to the first and second impedances. A current generating device, electrically coupled in series with the first and second impedances, provides a constant current through the first and second impedances to produce first and second voltages across the first and second impedances, respectively, and a parasitic voltage across the parasitic impedance. A high impedance voltage measuring device measures a voltage difference between the first and second voltages independent of the parasitic voltage to produce a characteristic voltage representative of the characteristic of the environment.

Anderson, Karl F.↗

Array trade-off study using multilayer parasitic subarrays

The use of multilayer parasitic patch arrays in a microstrip phased array offers many potential advantages. An analytical study of microstrip arrays with high gain multilayer parasitic patch subarrays and conventional patch antennas is presented. It is indicated that a thinned array of half as many multilayer parasitic patch subarrays (per row and column) at twice the spacing will perform as well as the full array of ordinary patch antennas. The criterion for comparison was array gain, 3 dB beamwidth and sidelobe level. The attendant reduction in the required number of patch antennas and consequently, MMIC phase shifters is very significant in terms of array complexity, cost and power loss.

Zaman, A.↗

Scan-independent slot arrays with parasitic wire arrays in stratified medium

The effect of a parasitic wire array on the scan admittance of a slot array has been investigated. Structures considered can consist of an infinite slot array and an arbitrary number of parasitic infinte arrays of piecewise linear wires, all arrays being embedded in a stratified medium. These include, as particular cases, phased arrays of Clavin elements. Expressing the fields from the arrays as plane waves, a procedure similar to the periodic moment method for infinite periodic structures is set up to obtain the the scan admittance of the slot array. Scan admittances are presented for a slot array with monopole arrays in free space, and a slot array with a tilted dipole array in a stratified medium. Blind spots at which the incident energy is mainly reflected rather than transmitted were found. Results obtained indicate the possibility of using parasitic wire arrays for scan compensation of active slot arrays.

Ng, Kwong T.↗

Controlled retroreflection - A technique for understanding and eliminating parasitic lasing

Parasitic lasing is examined with an emphasis on understanding and quantifying its effect on high-gain laser systems. Parasitic lasing is unwanted stimulated emission commonly found in high-gain optical systems. A general technique was developed that carefully retroreflects light back into the optical system, thereby creating an externally induced oscillator. Discrepancies between experimental data and threshold calculations for the externally induced oscillator are direct evidence of optical misalignment or of component performance problems. Any changes in the optical system can be directly measured as a change in threshold for the externally induced oscillator. This technique also enables one to align the system for maximum parasitic suppression with the system fully operational. Experimental data illustrating the utility of this technique are presented.

Storm, Mark E.↗

Parasitic instabilities in magnetized, differentially rotating disks

Velikhov, Chandrasekhar, Balbus & Hawley have discovered a MHD instability of differentially rotating fluids that may explain the effective viscosity of accretion disks. If the unperturbed magnetic energy density is much less than the gas pressure, this `magnetorotational' instability (MRI) arises on small scales and is approximately incompressible. If the unperturbed field is suffiently, strong, the MRI is suppressed. We therefore ask whether the MRI mechanism can amplify even very weak initial fields until they reach equipartition with the gas pressure. We show that in the total incompressible limit, the MRI modes are exact solutions of the nonlinear fluid equations, even if the perturbed magnetic field is much larger than the unperturbed field. Also, we present a new exact solution in the opposite limit that the magnetic pressure is much larger than that of the gas. On the other hand, we show that the incompressible MRI modes are themselves subject to parasitic instabilities with instantaneous growth rates proportional to the MRI amplitude. Some of the parasitic instabilities are of the Kelvin-Helmholtz type, while others are less familiar. The eigenfunctions of the latter group suggest that they may promote rapid reconnection of the MRI field. Thus, parasitic modes may stop MRI growth at subequipartition amplitudes if it developes from a sufficiently weak initital field.

Goodman, Jeremy↗

The Effects of Ground Plane and Parasitic Layer on Linearly Tapered Slot Antenna

The effects of a large ground plane and an upper parasitic layer on a linearly tapered slot antenna has been experimentally investigated. Results indicate that the presence of a large ground plane causes the beam to steer by as much as 50 deg from the endfire direction in the H-plane. With the addition of a parasitic layer above the fed antenna, further beam scanning can be achieved when the spacing between the fed and parasitic layers is properly chosen.

Lee, Richard Q.↗

Does Magnetic Field Affect Malaria Parasite Replication in Human Red Blood Cells?

Digestion of red blood cell (RBC) hemoglobin by the malaria parasite results in the formation of paramagnetic hemazoin crystals inside the parasite body. A number of reports suggest that magnetic field interaction with hamazoin crystals significantly reduces the number of infected cells in culture, and thus magnetic field can be used to combat malaria. We studies the effects of magnetic filed on the Plasmodium falciparum asexual life cycle inside RBCs under various experimental conditions. No effect was found during prolonged exposure of infected RBCs to constant magnetic fields up to 6000 Gauss. Infected RBCs were also exposed, under temperature-controlled conditions, to oscillating magnetic fields with frequencies in the range of 500-20000 kHz, and field strength 30-600 Gauss. This exposure often changed the proportion of different parasite stages in treated culture compared to controls. However, no significant effect on parasitemia was observed in treated cultures. This result indicates that the magnetic field effect on Plasmodium falciparum is negligible, or that hypothetical negative and positive effects on different stages within one 48-hour compensate each other.

Chanturiya, Alexandr N.↗

Effect of Parasitic Dielectric Resonators on CPW/Aperture-Coupled Dielectric Resonator Antennas

The effects of parasitic dielectric resonators on the HE (sub 11 sigma) and HE (High Efficiency) (sub 13 sigma) modes of a cylindrical dielectric resonator antenna (DRA) have been studied. The DRA was excited electromagnetically with a grounded coplanar waveguide through an aperture in the common ground plane. Strong couplings were observed for the HE (sub 11 sigma) mode with the parasitic element superimposed on the driven DRA, and for the HE (sub 13 sigma) mode with parasitic elements placed on both sides of the driven DRA. Results indicate significant enhancement in bandwidth for both modes, and good radiation patterns for the HE (sub 11 sigma) mode.

Simons, R. N.↗

Parasitic Interference in Nulling Interferometry

Nulling interferometry aims to detect faint objects close to bright stars. Its principle is to produce a destructive interference along the line of sight so that the stellar flux is rejected, while the flux of the off-axis source can be transmitted. In practice, various instrumental perturbations can degrade the nulling performance. Any imperfection in phase, amplitude or polarization produces a spurious flux that leaks to the interferometer output and corrupts the transmitted off-axis flux. One of these instrumental perturbations is the crosstalk phenomenon, which occurs because of multiple parasitic reflections inside transmitting optics, and/or diffraction effects related to beam propagation along finite size optics. It can include a crosstalk of a beam with itself, and a mutual crosstalk between different beams. This can create a parasitic interference pattern, which degrades the intrinsic transmission map - or intensity response - of the interferometer. In this context, we describe how this instrumental effect impairs the performance of a Bracewell interferometer. A simple formalism is developed to derive the corresponding modified intensity response of the interferometer, as a function of the two parameters of interest: the crosstalk level (or contamination rate) and the phase shift between the primary and secondary - parasitic - beams. We then apply our mathematical approach to a few scientific cases, both analytically and using the GENIESIM simulation software, adapted to handle coherent crosstalk. Our results show that a coherent crosstalk level of about 1 per cent implies a 20 per cent drop of the signal-to-noise ratio at most. Careful attention should thus be paid to reduce the crosstalk level inside an interferometric instrument and ensure an instrumental stability that provides the necessary sensitivity through calibration procedures.

circumstellar matter↗

Analytical design of a parasitic-loading digital speed controller for a 400-hertz turbine driven alternator

A design for a solid-state parasitic speed controller using digital logic was analyzed. Parasitic speed controllers are used in space power electrical generating systems to control the speed of turbine-driven alternators within specified limits. The analysis included the performance characteristics of the speed controller and the generation of timing functions. The speed controller using digital logic applies step loads to the alternator. The step loads conduct for a full half wave starting at either zero or 180 electrical degrees.

Ingle, B. D.↗

Circuit performance of a parasitic-loading digital speed controller for a 400-hertz turbine-driven alternator

Parasitic speed controllers are used in space power electrical generating systems to maintain the speed of the turbine-driven alternators within specified limits. Selected subcircuits for a solid state parasitic-loading speed controller were assembled and tested. The test results as obtained to date consist of the performance evaluation of the frequency reference and the period counter subcircuits. These circuits performed as expected.

Ryan, J. P.↗