Search NASA⌕ Search

SEARCH · Search NASA

Results for “partial coherence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Memory and CPU efficient coherent mode decomposition of partially coherent synchrotron radiation with subtraction of common quadratic phase terms

Application examples of a memory and CPU efficient coherent mode decomposition (CMD) method for wave-optics based simulation of the partially coherent undulator radiation propagation through a hard X-ray beamline in a 3rd generation synchrotron radiation source are presented. The high efficiency of the method is achieved thanks to the analytical treatment of the common quadratic phase terms that are developed in the phase of cross-spectral density (CSD) of partially coherent radiation at a distance from source. This treatment allows for a considerable, several orders of magnitude, reduction of the 4D CSD mesh density (and the memory occupied by the CSD) required for ensuring sufficient accuracies of wavefront propagation simulations with the modes produced by the CMD at a beamline entrance. This method, implemented in the “Synchrotron Radiation Workshop” open-source software, dramatically increases the feasibility of the CMD of 4D CSD for producing 2D coherent modes for a large variety of applications at storage rings and other types of radiation sources.

36 MATERIALS SCIENCE↗

CPU and memory efficient coherent mode decomposition for the partially coherent x-ray simulations

In this work, the method of the Coherent Mode Decomposition (CMD) is applied to numerical wave propagation calculations for partially-coherent X-rays, using the Fourier optics and compatible methods. Its CPU and memory efficiency is discussed in various cases of the wavefront at the source and the beam waist. With the absence of the quadratic phase terms, the required sampling density of the electric fields is effectively reduced. The problem size is thus moderate and the method is feasible to be implemented on a single-node CPU server. In other cases, the same argument holds with proper treatments of the quadratic phase terms. Tests on CMD and the modes propagation are done for the case of the Coherent Hard X-ray beamline of the National Synchrotron Light Source II, using the Synchrotron Radiation Workshop software. We observe a few hundred or less dominant decomposed modes that resemble the electric fields converge to the wavefront intensity at a high accuracy of over 99%.

36 MATERIALS SCIENCE↗

Error metrics for partially coherent wave fields

Lensless imaging methods that account for partial coherence have become very common in the past decade. However, there are no metrics in use for comparing partially coherent light fields, despite the widespread use of such metrics to compare fully coherent objects and wave fields. Here, we show how reformulating the mean squared error and Fourier ring correlation in terms of quantum state fidelity naturally generalizes them to partially coherent wave fields. We report these results fill an important gap in the lensless imaging literature and will enable quantitative assessments of the reliability and resolution of reconstructed partially coherent wave fields.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Partially Coherent Scattering in Stellar Chromospheres: Analytic Wing Approximations - Part 4

Simple analytic expressions are derived to understand resonance-line wings in stellar chromospheres and similar astrophysical plasmas. The results are approximate, but compare well with accurate numerical simulations. The redistribution is modeled using an extension of the partially coherent scattering approximation (PCS) which we term the comoving-frame partially coherent scattering approximation (CPCS). The distinction is made here because Doppler diffusion is included in the coherent/noncoherent decomposition, in a form slightly improved from the earlier papers in this series.

Gayley, K. G.↗

Multiple symbol partially coherent detection of MPSK

It is shown that by using the known (or estimated) value of carrier tracking loop signal to noise ratio (SNR) in the decision metric, it is possible to improve the error probability performance of a partially coherent multiple phase-shift-keying (MPSK) system relative to that corresponding to the commonly used ideal coherent decision rule. Using a maximum-likeihood approach, an optimum decision metric is derived and shown to take the form of a weighted sum of the ideal coherent decision metric (i.e., correlation) and the noncoherent decision metric which is optimum for differential detection of MPSK. The performance of a receiver based on this optimum decision rule is derived and shown to provide continued improvement with increasing length of observation interval (data symbol sequence length). Unfortunately, increasing the observation length does not eliminate the error floor associated with the finite loop SNR. Nevertheless, in the limit of infinite observation length, the average error probability performance approaches the algebraic sum of the error floor and the performance of ideal coherent detection, i.e., at any error probability above the error floor, there is no degradation due to the partial coherence. It is shown that this limiting behavior is virtually achievable with practical size observation lengths. Furthermore, the performance is quite insensitive to mismatch between the estimate of loop SNR (e.g., obtained from measurement) fed to the decision metric and its true value. These results may be of use in low-cost Earth-orbiting or deep-space missions employing coded modulations.

Simon, M. K.↗

The Impact of Firn Models on Ultrawideband Brightness Temperatures in the Partially Coherent Model

The density profile of a polar ice sheet is an important parameter for the estimation of ice mass balance. Wave reflections caused by density variations are also a key uncertainty in the retrieval of ice sheet temperature profiles in Ultra-Wide band radiometry. In this paper, we examine different firn density profile models and analyze the subsurface reflections they cause using an analytical partially coherent approach. We also examine firn density profiles obtained from borehole measurements, from past UWBRAD modeling studies, from a community firn model, and from snow radar echo measurements. In previous studies, the ice sheet has been model as a 1D random medium with density variations in depth. However, horizontal density variations also exist, so that the ice sheet is a 3D random medium. Analyses using the partially coherent model show that in the presence of horizontal fluctuations, contributions from short scale variations vanish as the horizontal correlation length decreases due to the diffraction of waves.

Haokui Xu↗

Partially coherent scattering in stellar chromospheres. I - Effects on resonance line thermalization

The conditions necessary for partially coherent scattering to influence the thermalization depth are investigated, and the effects of partial redistribution in homogeneous slab atmospheres are approximated using several common resonance lines as examples. For electron densities above 10 exp 10/cu cm, it is concluded that even when coherent scattering dominates the escape process, the thermalization depths of the strongest resonance lines of H, Ca II, and Mg II agree roughly with the Doppler diffusion in frequency. No elastic scattering effects on the thermalization of Mg II h and k and Ca II H and K are found. At lower densities, such as for giant star chromospheres and QSO models, the results deviate strongly from the Doppler complete redistribution case.

Gayley, Kenneth G.↗

X-ray computed tomography using partially coherent Fresnel diffraction with application to an optical fiber

A reconstruction algorithm for partially coherent x-ray computed tomography (XCT) including Fresnel diffraction is developed and applied to an optical fiber. The algorithm is applicable to a high-resolution tube-based laboratory-scale x-ray tomography instrument. The computing time is only a few times longer than the projective counterpart. The algorithm is used to reconstruct, with projections and diffraction, a tilt series acquired at the micrometer scale of a graded-index optical fiber using maximum likelihood and a Bayesian method based on the work of Bouman and Sauer. The inclusion of Fresnel diffraction removes some reconstruction artifacts and use of a Bayesian prior probability distribution removes others, resulting in a substantially more accurate reconstruction.

Levine, Zachary H. (ORCID:000000029928276X)↗

A study of partial coherence for identifying interior noise sources and paths on general aviation aircraft

The partial coherence analysis method for noise source/path determination is summarized and the application to a two input, single output system with coherence between the inputs is illustrated. The augmentation of the calculations on a digital computer interfaced with a two channel, real time analyzer is also discussed. The results indicate possible sources of error in the computations and suggest procedures for avoiding these errors.

Howlett, J. T.↗

Multiple-Symbol, Partially Coherent Detection of MPSK

Proposed method of reception of multiple-phase-shift-keyed (MPSK) radio signals involves multiple-symbol, partially coherent detection. Instead of attempting to determine phase of transmitted signal during each symbol period as in coherent detection, receiver acquires signal data during multiple-symbol observation interval, then produces maximum-likelihood-sequence estimate of phases transmitted during interval. Combination of coherent-reception and incoherent-reception decision rules are used.

Simon, Marvin K.↗

Particle image fields and partial coherence

The accuracy of Young's fringe method for reducing velocity field data is compromized by a spatially incoherent background field which originates in the random locations of the seeding particles. The probability density function for the spatial frequency cutoff of this background is derived as a function of the particle count, the distribution governing the power in each frequency interval is derived, and conditions are found under which the Van Cittert-Zernike theorem applies. The background field resembles the far field of a partially coherent source in the high particle count limit, but departs significantly at low and moderate counts.

Rubinstein, Robert↗