It is often difficult to model the effects of partial shading conditions on PV array performance, as shade losses are nonlinear and depend heavily on a system's particular configuration. This work describes and implements a simple method for modeling shade loss: a database of shade impact results (loss percentages), generated using a validated, detailed simulation tool and encompassing a wide variety of shading scenarios. The database is intended to predict shading losses in crystalline silicon PV arrays and is accessed using basic inputs generally available in any PV simulation tool. Performance predictions using the database are within 1-2% of measured data for several partially shaded PV systems, and within 1% of those predicted by the full, detailed simulation tool on an annual basis. The shade loss database shows potential to considerably improve performance prediction for partially shaded PV systems.
Site survey data for several residential installations are provided, showing the extent and frequency of shade throughout the year. This background information is used to design a representative shading test that is conducted on two side-by-side 8-kW photovoltaic (PV) installations. One system is equipped with a standard string inverter, while the other is equipped with microinverters on eachsolar panel. Partial shade is applied to both systems in a comprehensive range of shading conditions, simulating one of three shade extents. Under light shading conditions, the microinverter system produced the equivalent of 4% annual performance improvement, relative to the string inverter system. Under moderate shading conditions, the microinverter system outperformed the string invertersystem by 8%, and under heavy shading the microinverter increased relative performance by 12%. In all three cases, the percentage of performance loss that is recovered by the use of distributed power electronics is 40%-50%. Additionally, it was found that certain shading conditions can lead to additional losses in string inverters due to peak-power tracking errors and voltage limitations.
When a solar cell in a panel is shaded, the illuminated cells can place a large reverse bias on the shaded cell to attempt to force current through it. Although the panel can continue to produce power, the reverse bias can cause significant problems for the shaded cell. In the case of perovskite solar modules, Joule heating and irreversible electrochemical reactions will degrade the cell. Some photovoltaic technologies use bypass diodes to solve this problem. To prevent both a perovskite cell and an all-perovskite tandem cell from falling into reverse bias breakdown while shaded, no more than two cells per bypass diode are allowed, which is likely to be prohibitively expensive for many applications. Herein, how many solar cells can be protected by one bypass diode in single-junction and multijunction perovskite modules is explored. It is easier to incorporate bypass diodes into modules with singulated cells than with monolithic panels. It is shown that perovskite–silicon tandems can be protected with fewer bypass diodes than with single-junction perovskite modules. Furthermore, it is suggested that if bypass diodes cannot be feasibly incorporated, then the panels should be deployed in utility-scale power plants.
Partial shade of monolithic thin-film PV modules can cause reverse-bias conditions leading to permanent damage. In this work, we propose a partial shade stress test for thin-film PV modules that quantifies permanent performance loss. We designed the test with the aid of a computer model that predicts the local voltage, current and temperature stress that result from partial shade. The model predicts the module-scale interactions among the illumination pattern, the electrical properties of the photovoltaic material and the thermal properties of the module package. The test reproduces shading and loading conditions that may occur in the field. It accounts for reversible light-induced performance changes and for additional stress that may be introduced by light-enhanced reverse breakdown. We present simulated and experimental results from the application of the proposed test.
The typical configuration of monolithic thin-film photovoltaic modules makes it possible for partial shade to place one or more cells in such a module in reverse bias. Reverse bias operation leads to high voltage, current density, and power density conditions, which can act as driving forces for failure. We showed that a brief outdoor shadow event can cause a 7% permanent loss in power. We applied an indoor partial shade durability test that moves beyond the standard hot spot endurance test by using more realistic mask and bias conditions and by carefully quantifying the permanent change in performance due to the stress. With the addition of a pass criterion based on change in maximum power, this procedure will soon be proposed as a part of the module-type qualification test. All six commercial copper indium gallium diselenide and cadmium telluride modules we tested experienced permanent damage due to the indoor partial shade test, ranging from 4% to 14% loss in maximum power. We conclude by summarizing ways to mitigate partial shade stress at the cell, module, and system levels.
Degradation and partial shading impact the long-term reliability and power production of photovoltaic (PV) modules and power plants. Time-series power (P mp ) and current–voltage (I-V) curve datastreams from PV modules enable a remote diagnostic approach to quantify active degradation mechanisms and identify partial shading. We study three to nine years of these datastreams, including 3.6 million P mp I-V curves and 36 million values, from eight PV modules, four each of double-glass and glass-backsheet module architectures, located in three distinctly different Köppen-Geiger climate zones, to determine the module’s performance loss rates (PLR), identify active degradation mechanisms and power loss modes, along with partial shading by local objects. Considering both module architectures, PLR results indicate that the BSh climate zone is the most aggressive for module degradation, while the Alpine ET zone is the mildest climate. PLR of double-glass modules located in BWh and BSh climate zones are different due to the significantly greater uniform current loss (ΔP Isc ) for double-glass modules in BSh, at a 5% significance level. Power loss for four out of five modules located in the BWh and BSh climates are dominated by uniform current degradation. Statistical analysis of multistep I-V curves detects partial shading experienced by three studied modules with details of the shading profile, the shading Poynting vector diagram for the obstacle’s relative position, shading scenarios, and duration. Lastly, this work demonstrates how remote monitoring and diagnosis of P mp & I-V time-series of modules can provide quantitative operations and maintenance insights into system performance, degradation mechanisms, and shading.
In this paper, CuIn x Ga (1-x) (CIGS) mini-modules are stressed under reverse bias, resembling partial shading conditions, to predict and characterize where failures occur. Partial shading can cause permanent damage in the form of 'wormlike' defects on thin-film modules due to thermal runaway. This results in module-scale power losses. We have used dark lock-in thermography (DLIT) to spatially observe localized heating when reverse-bias breakdown occurs on various CIGS mini-modules. For better understanding of how and where these defects originated and propagated, we have developed techniques where the current is limited during reverse-bias stressing. This allows for DLIT-based detection and detailed studying of the region where breakdown is initiated before thermal runaway leads to permanent damage. Statistics of breakdown sites using current-limited conditions has allowed for reasonable identification of the as-grown defects where permanent breakdown will likely originate. Scanning electron microscope results and wormlike defect analysis show that breakdown originates in defects such as small pits, craters, or cracks in the CIGS layer, and the wormlike defects propagate near the top CIGS interface.
Photovoltaic cells can be damaged by reverse bias stress, which arises during service when a monolithically integrated thin-film module is partially shaded. We introduce a model for describing a module's internal thermal and electrical state, which cannot normally be measured. Using this model and experimental measurements, we present several results with relevance for reliability testing and module engineering: Modules with a small breakdown voltage experience less stress than those with a large breakdown voltage, with some exceptions for modules having light-enhanced reverse breakdown. Masks leaving a small part of the masked cells illuminated can lead to very high temperature and current density compared to masks covering entire cells.
Photovoltaic cells can be damaged by reverse bias stress, which arises during service when a monolithically integrated thin-film module is partially shaded. We introduce a model for describing a module's internal thermal and electrical state, which cannot normally be measured. Using this model and experimental measurements, we present several results with relevance for reliability testing and module engineering: Modules with a small breakdown voltage experience less stress than those with a large breakdown voltage, with some exceptions for modules having light-enhanced reverse breakdown. Masks leaving a small part of the masked cells illuminated can lead to very high temperature and current density compared to masks covering entire cells.
Maximum Power Point Tracking (MPPT) controller is required in a solar photovoltaic (PV) system to deliver the maximum power to load from PV module. This paper proposes a novel stepped MPPT method to realize a simple MPPT controller, which can track the real maximum power point (RMPP) even under partial shading conditions. The proposed algorithm is started by scanning the characteristic curve of the PV modules to detect the global maximum power point and then the algorithm will be switched to the conventional P&O algorithm to track the true maximum power point. The obtained simulation results, using Power electronic simulation software (PSIM), are compared with those found using the P&O method to confirm the performance of our proposed MPPT method even under non-uniform solar irradiation.
This paper presents background and experimental results from a single-string grid-tied PV system, operated under a variety of shading conditions.
Abstract not provided
Explore the source record for details and available documents.
Explore the source record for details and available documents.
In monolithically integrated photovoltaic (PV) modules, including CdTe, CIGS, and a-Si modules, some shadows can cause permanent damage under some operating conditions. This damage reduces efficiency and causes shunts that are visible to the eye and in luminescence imaging. Although these shadows are sometimes forbidden by product documentation, we have observed this type of damage in utility-scale PV systems. Existing standards ensure that qualified modules are safe to use after they are damaged by shadows. But no standard test exists to quantify the loss of efficiency that can result from this damage. In this work we describe new, accelerated tests to quantify the power loss that occurs due to shadows from human bodies and narrow objects, such as tools, placed nearby or directly touching modules. The tests are designed to be easy to conduct uniformly across products and laboratories. The tests can be performed outdoors and last only a few minutes. In our trials on commercial products, these tests resulted in 2%-27% permanent loss in power at standard test conditions (STC). The relative loss was several times larger when measured at lower irradiance. The tests we describe can be used to differentiate products, to direct the development of technological solutions to shadow sensitivity at the cell and module levels, and to establish the need for system-level and administrative solutions to the occurrence of shadows. Similar tests will be the basis of a new International Electrotechnical Commission (IEC) technical specification (TS) 63140.
Explore the source record for details and available documents.
Agrivoltaic systems are mixed systems of solar photovoltaic (PV) panels and agricultural production, where shade from the panels can result in lower evapotranspiration for crops, which is of particular interest for dryland agriculture. Dry-farmed tomato (Solanum lycopersicum) production in the Willamette Valley of Oregon has lower total yields and higher rates of blossom-end rot (BER) than irrigated tomato production, resulting in reduced marketable yields. To determine how dry-farmed ‘Early Girl’ tomato performed in an agrivoltaics system, a trial was conducted at the Valley Creek Solar Project (Salem, OR, USA) in 2020, using three different amendment treatments and three levels of shading from the panels. Amendment treatments were 0N (receiving no fertilizer), 84N (receiving 84 kg·ha −1 N), and 168N (receiving 168 kg·ha −1 N), applied as processed chicken manure. Plants were estimated to receive an irradiance factor of 30%, 76%, and 89% for full-shade, partial-shade, and full-sun treatments respectively. There was an interaction between amendment treatments and shading treatments in their effects on unblemished yield (yield of fruit without BER or sunscald). The optimum fertilizer application for full-shade and partial-shade rows was 84N, the optimum for full-sun rows was 0N. Fertilizing these rows at these rates resulted in an unblemished yield for the aisle of 11.1 t·ha −1 , which was lower than unblemished yields reported in previous experiments and trials in open fields. However, these results are from a single location and a single year, and other solar sites may behave more similar to open-field conditions. Shading from the panels increased average fruit weight and decreased incidence of BER and sunscald, suggesting that crops were less drought stressed. This resulted in similar unblemished yields for the full-shade and full-sun plots at 84N and 168N. Applying fertilizer resulted in higher total yields, smaller average fruit weight, increased BER incidence, and decreased sunscald incidence. The results suggest a possible synergy between dry-farmed tomato production and agrivoltaics, although several concerns remain, including difficulties managing the vegetation under panels, rules restricting PVs on high-value agricultural soils, and the possibility of soil compaction during PV installation.