Managing the techno-economic impacts of partial string failure in multistring energy storage systems

The role of energy storage systems (ESSs) is becoming increasingly important for today’s electric power systems. Unavailability of an ESS assigned to critical grid services may cause unwanted disruption of those services and hence, may have a significant techno-economic impact. Like any physical equipment, an ESS is vulnerable to various types of faults. Failure of one or more strings in a multistring ESS does not have to be the cause of shutting down the entire ESS. It can still operate with a partial number of strings and continue providing critical services to the grid, if there are no reliability or safety issues and is acceptable under applicable standards. However, it is important to make sure that the control strategies are adaptable to the changes in ESS capacity caused by failed strings. Also, depending on the previous operation and type of failure, the reallocation of duty cycle burden among available strings could be non-uniform. These complexities suggest that mitigation of the impact of partial failure in multistring ESSs is not trivial and needs careful consideration. This is the topic of this paper. The proposed work investigates the impact of partial failure of a large multistring ESS on the assigned service and develops strategies to adjust the ESS control duty cycles for reducing such impacts. In doing so, the paper proposes a novel two-stage framework that plans for the multistring failure using robust optimization theory and then adjusts in real-time using a rule-based algorithm, based on the real-time information on the power availability of the string. Illustrations provided in this work are based on frequency regulation use-case, which is a common application for many utility-scale ESSs. A 750 kilowatt (kW)/1500 kilowatt-hour (kWh) 3-string ESS is used for the demonstration in this work and the efficacy of the proposed method is demonstrated and compared against methods that do not incorporate string failure in their strategy. In particular, here we show that revenue loss of 93% can be incurred when partial string failure is not included in operation and planning. These losses in revenue are reduced by 60% with the proposed method.

25 ENERGY STORAGE↗

Techno-Economic Impact of Partial String Failure in Multi-string Energy Storage Systems

Electric utilities and large industrial/commercial customers, which integrate multi-MW multi-string energy storage systems (ESS), are typically at a significant risk of string failure. This results in the loss of system performance and capacity. In order to evaluate the accurate costs and benefits associated with a particular battery system, it is essential to incorporate the costs associated with battery string failure and, as a result, reduced capacity. This report analyzes how the economic losses can be estimated based on market rules and ESS availability. A framework for calculation of economic losses is developed and implemented with an illustrative string failure case for Independent System Operator (ISO-NE) forward capacity market. Further scenarios and case studies are analyzed by varying the probability of string failure as well as the capacity bid into the market. These scenarios are used to assess the variability of economic losses and the impact of string failure on the final realized benefits from the battery's market participation.

Fotedar, Vanshika↗

Techno-Economic Impact of Partial String Failurein Multi-string Energy Storage Systems

Electric utilities and large industrial/commercial customers, which integrate multi-MW multi-string energy storage systems (ESS), are typically at a significant risk of string failure. This results in loss of system performance and capacity. In order to evaluate the accurate costs and benefits associated with a particular battery system, it is essential to incorporate the costs associated with battery string failure and, as a result, reduced capacity. This report analyzes how the economic losses can be estimated based on market rules and ESS availability. A framework for calculation of economic losses is developed and implemented with an illustrative string failure case for Independent System Operator (ISO-NE) forward capacity market. Further scenarios and case studies are analyzed by varying the probability of string failure as well as the capacity bid into the market. These scenarios are used to assess the variability of economic losses and the impact of string failure on final realized benefits from the battery's market participation.

Fotedar, Vanshika↗

Physics-Based Method for Generating Fully Synthetic IV Curve Training Datasets for Machine Learning Classification of PV Failures

Classification machine learning models require high-quality labeled datasets for training. Among the most useful datasets for photovoltaic array fault detection and diagnosis are module or string current-voltage (IV) curves. Unfortunately, such datasets are rarely collected due to the cost of high fidelity monitoring, and the data that is available is generally not ideal, often consisting of unbalanced classes, noisy data due to environmental conditions, and few samples. In this paper, we propose an alternate approach that utilizes physics-based simulations of string-level IV curves as a fully synthetic training corpus that is independent of the test dataset. In our example, the training corpus consists of baseline (no fault), partial soiling, and cell crack system modes. The training corpus is used to train a 1D convolutional neural network (CNN) for failure classification. The approach is validated by comparing the model’s ability to classify failures detected on a real, measured IV curve testing corpus obtained from laboratory and field experiments. Results obtained using a fully synthetic training dataset achieve identical accuracy to those obtained with use of a measured training dataset. When evaluating the measured data’s test split, a 100% accuracy was found both when using simulations or measured data as the training corpus. When evaluating all of the measured data, a 96% accuracy was found when using a fully synthetic training dataset. The use of physics-based modeling results as a training corpus for failure detection and classification has many advantages for implementation as each PV system is configured differently, and it would be nearly impossible to train using labeled measured data.

Hopwood, Michael W. (ORCID:0000000161901767)↗

Hotspot testing of glass/backsheet and glass/glass PV modules pre-stressed in extended thermal cycling

This paper investigates the effect of hotspot (HS) stress endurance of two of the latest designs of monocrystalline modules: a half-cell glass/backsheet (G/B) module and a full-cell glass/glass (G/G) module. These modules have already been pre-stressed in extended thermal cycling with 600 cycles per the IEC 61215 standard to represent field-stressed modules. This study differs from the other conventional studies wherein only fresh modules are subjected to hotspot endurance stress. The G/G module reached a maximum temperature of approximately 200 °C at a cell shading of 25 %, 55 °C higher than the maximum hotspot temperature of 145 °C in the G/B module. A significant burn mark, without glass shattering, was observed in the hotspot-stressed cell of the G/G module due to the current mismatch induced by partial shading. Most of the cells in the G/G module appear to be severely damaged (severe dark areas), as observed in the electroluminescence (EL) image, while the dark regions were rarely present in the G/B module. The EL image also illustrates multiple cell cracks that resist current flow and eventually contribute to the full-cell module degradation. About 8.3 % degradation in maximum power was observed for the G/G module and 1.3 % for the G/B module after the sequential stress tests. The lower degradation in the G/B module can potentially be attributed to its design, which comprises of two parallel strings, each having 72-half-cells and benefits from lower heat dissipation. Furthermore, this indicates that the half-cell design could potentially minimize the hotspot degradation and failures in crystalline-silicon modules.

14 SOLAR ENERGY↗