Automated Particle Analysis of Hanford Tank Wastes 241-AN-106, 241-AN-101, and 241-AW-105
This effort is involved in developing particle size and density distribution (PSDD) for the major phases within Hanford tank waste sludge. The object of this work has been to use automated particle analysis (APA) methods on the Scanning Electron Microscope (SEM) to provide PSDDs. The PSDD can be used to quantify the proportion of gibbsite particles likely to settle quickly and enable blending of wastes that may be prone to pipeline plugging such as the uranium phase, clarkeite with other wastes. The Hanford tank waste solids were analyzed with SEM combined with x-ray Energy Dispersive Spectroscopy (EDS) using APA. This method can allow thousands of individual particles to be characterized and so may provide a more representative view of the samples and information PSDDs. We characterized several as-received sludge samples and developed PSDD with APA. Sample preparation methods were found to impact the collected results, as it was more difficult to collect representative samples of the larger particles. Much of the material was also dried and cemented together that further impacted results.