Search NASA⌕ Search

SEARCH · Search NASA

Results for “particle detection in electronic packages”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Neural Networks Analyze Data In Particle-Impact-Noise Tests

Electronic neural networks and computers put to use in analyzing data acquired in particle-impact-noise-detection (PIND) tests of packaged electronic components. PIND tests detect loose particles in packages that cause failures during subsequent operation of packages in presence of accelerations or other effects - for example, loose electrically conductive particles that bounce into positions in which they cause short circuits. Interpretation of test data more objective and accurate. Preliminary results suggest use of neural networks result in significant improvement in quality and reliability and decrease in cost of PIND testing.

Scaglione, Lois J.↗

Characteristics of the lunar photoelectron layer in the geomagnetic tail.

The charged particle lunar environment experiment, a part of the Apollo 14 lunar surface package, is an ion-electron spectrometer capable of measuring ions and electrons with energies between 40 eV and 50 keV. The instrument, with apertures 26 cm above the surface, has detected a photoelectron gas layer above the sunlit lunar surface. No detectable flux above 200 eV has been observed. Experimental data for periods while the moon was in the earth's magnetotail for electrons with energies 40 eV less than or equal to 200 eV follow a power-law spectrum. In the absence of photoelectrons with E greater than 200, we assume that the surface potential is at least 200 V. The modulation of this potential in the presence of intense plasma-sheet fluxes has been observed. Also, a detailed history of the Feb. 10, 1971, total lunar eclipse, to determine the source distribution of high-energy solar photons, is presented.

Reasoner, D. L.↗

Measuring Water-Layer Thickness

Technique uses optical proximity detector. Detector consists of sensing probe, cartridge containing photocell and light source, and electronics package, housed in metal carrying case. Light transmitted from fiber-optic probe reflected by observed surface and transmitted back through probe to photoreceiver, output of which indicated on digital voltmeter or other suitable instrument. Sensor used to detect presence of bubbles or particles in water stream or to trigger alarm when condensing water becomes present in bottom of supposedly dry tank. Fiber-optic probes of sizes up to 0.285 in. (7.24 mm) with varying sensitivities and configurations available for use with system.

Faulcon, N.↗

Objectives and design of the Echo 6 electron beam experiment - Large ionospheric perturbations and energetic particle patterns

The data from the March 30, 1983 launching of Echo 6 are presented. Echo 6 contained duplex accelerators and a system of four throw away detectors to detect and analyze conjugate electron echoes. The model used to calculate the proper trajectory of the rocket and the reason for not detecting echoes are discussed. The components of the plasma diagnostic package which was used to study the electron beam interactions with the ionospheric plasma, and the functions of the two controllable electron guns and the two sets of orthogonal electric probes are described. The signal-mode potentials between each probe and the plasma diagnostic payload are investigated. The signals produced by the gun pulses are analyzed and the interpretation of the electric field probe response is examined.

Winckler, J. R.↗

Description of the plasma diagnostics package (PDP) for the OSS-1 Shuttle mission and JSC plasma chamber test in conjunction with the fast pulse electron gun (FPEG)

The objectives, equipment, and techniques for the plasma diagnostics package (PDP) carried by the OSS-1 instrument payload of the STS-4 and scheduled for the Spacelab-2 mission are described. The goals of the first flight were to examine the Orbiter-magnetoplasma interactions by measuring the electric and magnetic field strengths, the ionized particle wakes, and the generated waves. The RMS was employed to lift the unit out of the bay in order to allow characterization of the fields, EM interference, and plasma contamination within 15 m of the Orbiter. The PDP will also be used to examine plasma depletion, chemical reaction rates, waves, and energized plasma produced by firing of the Orbiter thrusters. Operation of the PDP was carried out in the NASA Space Environment Simulation Laboratory test chamber, where the PDP was used to assay the fields, fluxes, wave amplitudes, and particle energy spectra. The PDP instrumentation is also capable of detecting thermal ions, thermal electrons suprathermal particles, VHF/UHF EMI levels, and the S-band field strength.

Shawhan, S. D.↗

Fire Signatures of Materials Used in Spacecraft Construction

The focus of my work this summer was fire safety, specifically determining fire signatures from the combustion of materials commonly found in the construction of spacecraft. This project was undertaken with the aim of addressing concerns for health and safety onboard spacecraft. Under certain conditions, burning electronics produce surprisingly large amounts of acrid smoke, release fine airborne particles and expel condensable aerosols. Similarly, some wire insulation and packing material evolves smoke when in contact with a hot surface. In the limited, enclosed space available on spacecraft, these combustion products may pose a nuisance at the very least - at worst, a hazard to health or equipment. There is also a concern for fire safety in early detection on spacecraft. Our goal for the summer was to determine the most effective methods to test the materials, develop a protocol for sampling, and generate samples for analysis. We restricted our testing to electronic components, packaging and insulation materials, and wire insulation materials.

Taylor, Christina↗

NASA Tech Briefs, February 2014

Topics include: JWST Integrated Simulation and Test (JIST) Core; Software for Non-Contact Measurement of an Individual's Heart Rate Using a Common Camera; Rapid Infrared Pixel Grating Response Testbed; Temperature Measurement and Stabilization in a Birefringent Whispering Gallery Resonator; JWST IV and V Simulation and Test (JIST) Solid State Recorder (SSR) Simulator; Development of a Precision Thermal Doubler for Deep Space; Improving Friction Stir Welds Using Laser Peening; Methodology of Evaluating Margins of Safety in Critical Brazed Joints; Interactive Inventory Monitoring; Sensor for Spatial Detection of Single-Event Effects in Semiconductor-Based Electronics; Reworked CCGA-624 Interconnect Package Reliability for Extreme Thermal Environments; Current-Controlled Output Driver for Directly Coupled Loads; Bulk Metallic Glasses and Matrix Composites as Spacecraft Shielding; Touch Temperature Coating for Electrical Equipment on Spacecraft; Li-Ion Electrolytes Containing Flame-Retardant Additives; Autonomous Robotic Manipulation (ARM); CARVE Log; Platform Perspective Toolkit; Convex Hull-Based Plume and Anomaly Detection; Pre-Filtration of GOSAT Data Using Only Level 1 Data and an Intelligent Filter to Remove Low Clouds; Affordability Comparison Tool - ACT; "Ascent - Commemorating Shuttle" for iPad; Cassini Mission App; Light-Weight Workflow Engine: A Server for Executing Generic Workflows; Model for System Engineering of the CheMin Instrument; Timeline Central Concepts; Parallel Particle Filter Toolkit; Particle Filter Simulation and Analysis Enabling Non-Traditional Navigation; Quasi-Terminator Orbits for Mapping Small Primitive Bodies; The Subgrid-Scale Scalar Variance Under Supercritical Pressure Conditions; Sliding Gait for ATHLETE Mobility; and Automated Generation of Adaptive Filter Using a Genetic Algorithm and Cyclic Rule Reduction.

Source record↗

Cosmic ray particle dosimetry and trajectory tracing

Five pocket mice (Perognathus longimembris) were flown on Apollo XVII, each with a solid-state (plastic) nuclear track detector implanted beneath its scalp. The subscalp detectors were sensitive to HZE cosmic ray particles with a LET greater than or approximately equal to 0.15 million electron volts per micrometer (MeV/micron). A critical aspect of the dosimetry of the experiment involved tracing individual particle trajectories through each mouse head from particle tracks registered in the individual subscalp detectors, thereby establishing a one-to-one correspondence between a trajectory location in the tissue and the presence or absence of a lesion. The other major aspect was the identification of each registered particle. An average of 16 particles with Z greater than or equal to 6 and 2.2 particles with Z greater than or equal to 20 were found per detector. The track density, 29 tracks/sq cm, when adjusted for detection volume, was in agreement with the photographic emulsion data from an area dosimeter located next to the flight package.

Cruty, M. R.↗

Optical Analysis of Impact Features in Aerogel From the Orbital Debris Collection Experiment on the MIR Station

The Mir Environmental Effects Package (MEEP) was deployed on the Mir station and retrieved after 18 months in space. The payload included the orbital debris collector (ODC), designed and built at the Johnson Space Center to capture and return analyzable residues of the man-made and natural particulate environment in low-Earth orbit for a detailed assessment of its compositional makeup and potential origins. The ODC exposed 2 identical trays, with highly porous, low-density SiO2 aerogel as the basic collector medium, pointed in opposite directions. The aerogel was expected to gently decelerate and capture hypervelocity particles, as opposed to other media that resulted in melting or vaporization of many impactors. Even cursory examination of the returned ODC collectors revealed a surprising variety of impact features. The compositional analyses using scanning electron "miccroscope-energy-dispersive X-ray spectroscopy concentrated on a survey-type inventory of diverse particle types and associated impact features. Detections, in the form of carrot-shaped tracks and shallow pits, included metallic Al, stainless steel, soldering compounds, human waste, and paint flakes. Many pits contained no detectable impactor residue (it was assumed to have vaporized), but most of the tracks contained analyzable residue. The study showed that aerogel would be useful for future low-velocity impact analysis.

Hoerz, Friedrich↗

Beagle 2: The Next Exobiology Mission to Mars

Beagle 2 is a 60 kg probe (with a 30 kg lander) developed in the United Kingdom for inclusion on the European Space Agency's 2003 Mars Express. Beagle 2 will deliver to the Martian surface a payload which consists of a high percentage of science instruments to landed spacecraft mass. Beagle 2 will be launched in June, 2003 with Mars Express on a Soyuz-Fregat rocket from the Baikonur Cosmodrome in Kazakhstan. Beagle 2 will land on Mars on December 26, 2003 in the Isidis Planitia basin (approximately 10 degrees N and 275 degrees W), a large sedimentary basin that overlies the boundary between ancient highlands and northern plains. Isidis Planitia, the third largest basin on Mars, which is possibly filled with sediment deposited at the bottom of long-standing lakes or seas, offers an ideal environment for preserving traces of life. Beagle 2 was developed to search for organic material and other volatiles on and below the surface of Mars in addition to the study of the inorganic chemistry and mineralogy. Beagle 2 will utilize a mechanical mole and grinder to obtain samples from below the surface, under rocks and inside rocks. A pair of stereo cameras will image the landing site along with a microscope for examination of surface and rock samples. Analyses will include both rock and soil samples at various wavelengths, X-ray spectrometer and Mossbauer spectrometer as well as a search for organics and other light element species (e.g. carbonates and water) and measurement of their isotopic compositions. Beagle 2 has as its focus the goal of establishing whether evidence for life existed in the past on Mars at the Isidis Planitia site or at least establishing if the conditions were ever suitable. Carbonates and organic components were first recognized as existing on Mars when they were found in the Martian meteorite Nakhla. Romanek et al showed the carbonates in ALH84001 were formed at low temperatures. McKay et al noted possible evidence of early life on Mars within the ALH84001 meteorite. Thomas-Keprta et al showed the magnetite biomarkers in ALH84001's carbonates are indistinguishable from those formed by magnetotactic bacteria found on Earth. Gibson et al showed there was significant evidence for liquid water and biogenic products present on Mars across a 3.9 billion year period. A mechanical arm (PAW) operates from the lander and is used for science operations along with sample acquisition. Instruments attached to the PAW include: stereo cameras, Mossbauer instrument, X-ray fluorescence instrument, microscope, environmental sensors, rock corer/grinder, a spoon, mirror, brushes, a mole attachment for acquisition of subsurface to depths of 1 to 2 meters and an illumination device. Each camera has 14 filters which have been optimized for mineralogy composition, dust and water vapor detection. The microscope's camera is designed for viewing the size and shape of dust particles, rock surfaces, microfossils, and characteristics of the samples prior to introduction into the gas analysis package (GAP). The camera has a resolution of 4 microns/pixel, features four color capability (red, green, blue and UV (ultraviolet) fluoresence), a depth of focus of 40 micrometers and translation stage of +3 millimeters. The heart of the Beagle 2's life detection package is the gas analysis package (GAP), which consists of a mass spectrometer with collectors at fixed masses for precise isotopic ratio measurements and voltage scanning for spectral analysis. Primary aim of the GAP is to search for the presence of bulk constituents, individual species, and isotopic fractionations for both extinct and extent life along with studying the low-temperature geochemistry of the hydrogen, carbon, nitrogen and oxygen components on Mars from both the surface and atmosphere. GAP is a magnetic sector mass spectrometer with the range of 1 to 140 amu which can be operated in both the static and dynamic modes. A triple Faraday collector array will be used for C, N and O ratios along with a double Faraday array for H/D. Pulse counting electron multiplier will be utilized for noble gases and selected organics. Anticipated detection limits are at the picomole level for operation in the static mode of operation and high precision isotopic measurements will be made in the dynamic mode. Sample processing and preparation system consists of reaction vessels along with references. Sample ovens capable of being heated are attached to the manifold for sample combustion. Surface, subsurface materials and interior rock specimens will be combusted in pure oxygen gas at various temperature intervals to release organic matter and volatiles. Combustion process will permit detection of all forms and all atoms of carbon present in the samples. A chemical processing system is capable of a variety of conversion reactions. Gases are manipulated either by cryogenic or chemical reactions and passed through the gas handling portion of the vacuum system. There are two modes of operation: quantitative analysis and precise isotopic measurements. Additional information is contained in the original extended abstract.

Gibson, Everett K., Jr.↗