Search NASA⌕ Search

SEARCH · Search NASA

Results for “particle instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

SERENA: Particle Instrument Suite for Determining the Sun-Mercury Interaction from BepiColombo

The ESA-JAXA BepiColombo mission to Mercury will provide simultaneous measurements from two spacecraft, offering an unprecedented opportunity to investigate magnetospheric and exospheric particle dynamics at Mercury as well as their interactions with solar wind, solar radiation, and interplanetary dust. The particle instrument suite SERENA (Search for Exospheric Refilling and Emitted Natural Abundances) is flying in space on-board the BepiColombo Mercury Planetary Orbiter (MPO) and is the only instrument for ion and neutral particle detection aboard the MPO. It comprises four independent sensors: ELENA for neutral particle flow detection, Strofio for neutral gas detection, PICAM for planetary ions observations, and MIPA, mostly for solar wind ion measurements. SERENA is managed by a System Control Unit located inside the ELENA box. In the present paper the scientific goals of this suite are described, and then the four units are detailed, as well as their major features and calibration results. Finally, the SERENA operational activities are shown during the orbital path around Mercury, with also some reference to the activities planned during the long cruise phase.

79 ASTRONOMY AND ASTROPHYSICS↗

Experimental study on particle formation in a pressurized oxy-fuel combustor using a novel in-situ optical instrument

Particle formation in pressurized oxy-fuel combustion can be fundamentally different from oxy-fuel combustion at atmospheric pressure. Under high pressures, the rate of char gasification with CO2 and H2O increases significantly and dominates the char reactions particularly at high temperatures. Also, the extent of fragmentation varies. This could result in a very different particle size distribution from that of air-fired combustion. To accurately obtain the particle size distribution in a pressurized oxy-fuel combustor without sampling bias, the particle measurement should be made at the system pressure. Very few published studies have accomplished this, and never under the conditions reported herein. In this work, we fire PRB coal in a 100 kWth staged pressurized oxy-fuel combustor (SPOC) under two pressures, 15 and 2 bara. A sampling probe (oil-cooled) is installed at the combustor outlet and the aerosol flow are sampled isokinetically. We utilize a state-of-the-art optical analyzer (Malvern Insitec) with a novel high-pressure and high-temperature flow cell to measure the particle size distribution and concentration in-situ in a sampled flow, which contains moist/corrosive flue gas under the process pressure and a controlled temperature that is kept above the dew point. The results show that the pressure can significantly influence the particle size distribution and concentration from the oxy-fuel combustor.

Cheng, Mao↗

Ultrafine Condensation Particle Counter Instrument Handbook

The Model 3776 Ultrafine Condensation Particle Counter (UCPC; pictured in Appendix A) is designed for researchers interested in airborne particles smaller than 20 nm. With sensitivity to particles down to 2.5 nm in diameter, this UCPC is ideally suited for atmospheric and climate research, particle formation and growth studies, combustion and engine exhaust research, and nanotechnology research.

47 OTHER INSTRUMENTATION↗

Cryo nanomanipulator probe with integrated gas injection

A probe assembly for use with a charged particle instrument includes an elongate body having a proximal end for positioning outside of a charged particle instrument enclosed environment, a distal end for positioning within the enclosed environment and a longitudinal axis. A port interface is located on the body between the proximal and distal ends, and is coupleable to a nanomanipulator system of the charged particle instrument. A probe needle is positioned at a distal end of the body and is selectively positionable from outside the enclosed environment to contact a specimen within the enclosed environment. At least one gas injection needle is adjustably positioned near the probe needle. The gas injection needle is connectable to a source of pressurized gas to selectively inject gas in the area of the probe needle within the enclosed environment.

Perea, Daniel E.↗

Solid particulate mass and number from ducted fuel injection in an optically accessible diesel engine in skip-fired operation

Ducted fuel injection (DFI) is a new combustion strategy that has been shown to significantly attenuate soot formation in diesel engines. While previous studies have used optical diagnostics and optical filter smoke number methods to show that DFI reduces in-cylinder soot formation and engine-out soot emissions, respectively, this is the first study to measure solid particle number (PN) emissions in addition to particle mass (PM). Furthermore, this study quantitatively evaluates the use of transient particle instruments for measuring particles from skip-fired operation in an optical single cylinder research engine (SCRE). Engine-out PN was measured using an engine exhaust particle sizer following a catalytic stripper, and PM was measured using a photoacoustic analyzer. The study improves on earlier preliminary emissions studies by clearly showing that DFI reduces overall PM by 76%–79% and PN for particles larger than 23 nm by 77% relative to conventional diesel combustion at a 1200-rpm, 13.3-bar gross indicated mean effective pressure operating condition. The degree of engine-out PM reduction with DFI was similar across both particulate measurement instruments used in the work. Through the use of bimodal distribution fitting, DFI was also shown to reduce the geometric mean diameter of accumulation mode particles by 26%, similar to the effects of increased injection pressure in conventional diesel combustion systems. This work clearly shows the significant solid particulate matter reductions enabled by DFI while also demonstrating that engine-out PN can be accurately measured from an optical SCRE operating in a skip-fired mode. Based on these results, it is believed that DFI has the potential to enable fuel savings when implemented in multi-cylinder engines, both by lowering the required frequency of active diesel particulate filter regeneration, and by reducing the backpressure imposed by exhaust filtration systems.

33 ADVANCED PROPULSION SYSTEMS↗

Network of Modified Portable Optical Particle Spectrometers Instrument Handbook

The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s portable optical particle spectrometer (POPS) network (Figure 1) provides an aerosol size distribution spectrum from 150 nm to 5 μm in 16 logarithmically spaced bins. The data emanating from this network of up to four matching POPS in weatherproof enclosures comprises one-minute averages of the aerosol size and number spectrum and the co-located temperature and relative humidity. The total particle concentration and sample flow rate are also provided. The sample stream is not dried before its measurement. Two size spectra are provided: the default size distribution corresponds to the calibration using polystyrene latex spheres (PSL), while the second size distribution corresponds to the calibration using size-selected dry ammonium sulfate aerosol. The principal scientific application of the data provided by the ARM POPS is to determine the aerosol size distribution across a region in three disparate locations – the size distribution is broadly relevant to studies of pollution and of conditions in the boundary layer. A high particle concentration can be an indicator of unhealthy levels of pollution; the dispersion of particles in the atmosphere is a predictor of long-range visibility; and particles serve as collectors of condensing gases including water vapor, and thus are a factor in the formation and properties of fogs and clouds, and in the initiation of precipitation.

54 ENVIRONMENTAL SCIENCES↗

Low Energy Neutron-induced Charged-particle (Z) (LENZ) instrument development with a focus on pulse shape discrimination for low-energy charged particles

To study neutron-induced charged-particle reactions with high precision, the Low Energy Neutron-induced Charged-particle (Z) instrument (LENZ) was developed at the Los Alamos Neutron Science Center. For the interest of measuring (n,p) and (n, α) reactions simultaneously, Pulse Shape Discrimination methods were investigated to identify different charged particles in the energy range of 3 - 20 MeV and improve signal-to-background ratios using Double-sided Silicon Strip Detectors and waveform digitizers. The risetime and pulse shape properties of detected charged particles were characterized for various silicon detector’s thickness with different orientations. During the post-processing of waveforms, we implemented different digital filters for effective particle identifications and improved energy- and timing- resolutions. We validated the optimized digital filters and pulse shape analyses, via measurements with 228 Th and 229 Th calibration sources, proton-induced reactions on a 7 LiF target, and neutron-induced reactions on CH 2 , Ta 2 O 5 , 58 Ni, and 6 LiF/ 59 Ni targets at the time-of-flight facility, LANSCE. In conclusion, the summary of effective thresholds and Figure of Merits on separating different charged particles is reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cold Plasma Measurements

We have continued the simulation campaign in support of our ongoing magnetospheric cold plasma research project. This project aims to develop the next-generation particle instruments to measure the properties of the cold particle populations in the Earth’s magnetosphere. For this purpose, simulations have been performed with a Particle-In-Cell (PIC) code called the Curvilinear PIC (CPIC). The code is formulated in curvilinear geometry and couples the standard PIC algorithm with algorithms for the generation and adaptation of the underlaying computational mesh. It conforms to complex objects like spacecraft and it can place more grid points in regions where higher resolution is needed. The code also features a scalable solver based on the multigrid algorithm and it is fully parallelized via domain decomposition and MPI.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cold Plasma IC Report

This past year we completed the simulation campaign in support of our magnetospheric cold plasma research project. This project aimed to develop the next-generation particle instruments to measure the properties of the cold particle populations in the Earth’s magnetosphere.

58 GEOSCIENCES↗

Condensation Particle Counter (CPC) Instrument Handbook

The Model 3772 CPC is a compact, rugged, and full-featured instrument that detects airborne particles down to 10 nm in diameter, at an aerosol flow rate of 1.0 lpm, over a concentration range from 0 to 1x104 #/cc. This CPC is ideally suited for applications without high concentration measurements, such as basic aerosol research, filter and air-cleaner testing, particle counter calibrations, environmental monitoring, mobile aerosol studies, particle shedding and component testing, and atmospheric and climate studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scanning Mobility Particle Sizer (SMPS) Instrument Handbook

The Model 3936 Scanning Mobility Particle Spectrometer (SMPS) measures the size distribution of aerosols ranging from 10 nm up to 1000 nm. The SMPS uses a bipolar aerosol charger to keep particles within a known charge distribution. Charged particles are classified according to their electrical mobility, using a long-column differential mobility analyzer (DMA). Particle concentration is measured with a condensation particle counter (CPC). The SMPS is well-suited for applications including: nanoparticle research, atmospheric aerosol studies, pollution studies, smog chamber evaluations, engine exhaust and combustion studies, materials synthesis, filter efficiency testing, nucleation/condensation studies, and rapidly changing aerosol systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Global Prompt Proton Sensor Network: Monitoring Solar Energetic Protons Based on GPS Satellite Constellation

Energetic particle instruments on board Global Positioning System (GPS) satellites form a powerful global prompt proton sensor network (GPPSn) that provides an unprecedented opportunity to monitor and characterize solar energetic protons targeting the Earth. The medium-Earth orbits of the GPS constellation have the unique advantage of allowing solar energetic protons to be simultaneously measured from multiple points in both open- and closed-field line regions. Examining two example intervals of solar proton events, we showcase in this study how GPS proton data are prepared, calibrated, and utilized to reveal important features of solar protons, including their source, acceleration/scattering by interplanetary shocks, the relative position of Earth when impinged by these shocks, the shape of solar particle fronts, the access of solar protons inside the dynamic geomagnetic field, and temporally varying proton distributions in both energy and space. By comparing to Van Allen Probes data, GPS proton observations are further demonstrated not only to be useful for qualitatively monitoring the dynamics of solar protons but also for quantitative scientific research including determining cutoff L-shells. Finally, our results establish that this GPPSn can join forces with other existing solar proton monitors and contribute to observing, warning, understanding, and ultimately forecasting the incoming solar energetic proton events.

47 OTHER INSTRUMENTATION↗

Holistic Numerical Calibration of the iMESA Electrostatic Analyzer

A drifted Maxwellian velocity distribution is the most common model used to interpret the data from low-energy charged-particle instruments onboard spacecraft that are used to investigate the ambient plasma environment in the low Earth orbit (LEO). An original method is presented for determining the flow parameters (density, temperature, and flow energy) of such a distribution from the output of the integrated miniaturized electrostatic analyzer, which has been successfully flown on several LEO missions. Rather than attempting to deconvolve from the on-orbit data the analyzer’s response to an ideal, monoenergetic input, numerical simulation is used to predict and parameterize the response of the device to an input distribution that includes an isotropic, non-zero temperature, yielding a straightforward method for extracting the flow parameters from the spacecraft data. The method is computationally simple enough to be incorporated into a robust algorithm suitable for rapid batch processing or real-time analysis of data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of a Smoke Opacity Sensor for Improving Residential Wood Heater Combustion

Residential wood heating lacks real-time particulate matter (PM) monitoring technologies capable of measuring emissions directly from flue gases. This study evaluates the performance of the Octoring, an opacity-based smoke sensor developed to monitor wood heater emissions and provide feedback for improved combustion. The device was tested on catalytic and non-catalytic cordwood heaters and a pellet heater during startup, high-burn, and low-burn phases. Performance was assessed against reference particle instruments and gravimetric measurements using concordance, correlation, and agreement analyses. Results show that temperature-dependent drift is the primary limitation affecting sensor accuracy, with systematic drift observed across ambient and combustion conditions. Agreement with reference instruments ranged from poor to good depending on operating conditions, with the strongest performance observed during pellet heater high-burn operation. These findings establish a performance baseline for opacity-based sensing technologies and identify key areas for further development before practical deployment in residential wood combustion monitoring systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enabling Lean and Stoichiometric Gasoline Direct Injection Engines through Mitigation of Nanoparticle Emissions

This project had the objective to efficiently reduce particulate mass (PM) and particulate number (PN) from lean and stoichiometric gasoline direction injection engines used in light duty vehicle applications. It also sought to use suspended particle instruments to measure the effective density, illustrating a pathway for new methods for accurately measuring soot mass at low concentration. The three-year effort took a systems level approach to evaluate fuel and lubricant impacts on GDI soot formation in lean and stoichiometric operation and to evaluate the impact of these factors on soot filtration aftertreatment in three-way catalyst-coated gasoline particulate filters (GPFs).

33 ADVANCED PROPULSION SYSTEMS↗

Establishing robust correction schemes for improved and reliable ARM-AOS aerosol optical data products

Aerosol light absorption and scattering of solar radiation play an important role in the earth’s atmosphere in terms of direct and semi-direct radiative forcing. Optical parameters of importance to the US Department of Energy (DOE) climate models include absorption and scattering coefficients, single scattering albedo (SSA), absorption Angstrom exponents (AAE), and the asymmetry parameter (g). These parameters depend on aerosol size, shape and composition (refractive index), and are spectrally sensitive in the shortwave region. Additionally, these parameters have a complex dependency on the emission source, especially for carbonaceous aerosols. The DOE Atmospheric Radiation Measurement (ARM) user facility has deployed aerosol observing systems (AOS) containing several filter-based instruments to measure and constrain aerosol optical properties and related parameters at multiple sites worldwide. For measurement of aerosol light absorption, the AOS includes filter-based instruments (particle soot absorption photometer and tricolor absorption photometer) that infer particle-phase aerosol absorption coefficients at nominal red, green, and blue wavelength bands from the attenuation (ATN) of light passing through a particulate filter on which aerosols are deposited. Measurement of aerosol scattering is done in situ using nephelometers. By combining inferred absorption coefficients from filter-based ATN measurements and in situ scattering coefficients, value-added products (VAPs) such as SSA, AAE, and g are derived.

54 ENVIRONMENTAL SCIENCES↗