Search NASA⌕ Search

SEARCH · Search NASA

Results for “passive cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Active and passive cooling approaches for a Southern California residential community

This study assesses cooling strategies in a low-income community in Southern California that lacks air conditioning and struggles with heat and air pollution. We used an urban building energy model and an electric distribution system model to evaluate active and passive cooling measures. The most effective space cooling measures were high-performance air-source heat pumps, cool coatings, window films, and harnessing the space cooling effect from heat pump water heaters. The results show that combining heat pump water heaters with window films and cool coatings reduces heat index hazard hours within buildings by 95 % to 99 % but increases total energy costs (equipment costs plus changes in utility bills) by 20 % to 60 % where the higher end includes building electrical upgrades. These measures also led to increased space heater use during colder months to avoid overcooling. Replacing conventional heaters with air source heat pumps eliminated unsafe indoor temperatures and reduced total energy use, but increased cost by 125 % to 150 %. In total, using heat pumps for space and water heating could reduce primary energy use by up to 57 %. The higher cost of active and passive cooling measures can be mitigated by existing and emerging incentive programs, especially those that support heat pumps. Electric distribution upgrades to support community electrification are estimated to increase utility costs by $\$$25 to $\$$40 per ratepayer per year. The results underscore the potential and challenges of adapting building infrastructure in communities at risk from climate and environmental stressors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

Coating to cool a surface by passive radiative cooling

Disclosed herein in is a radiative cooling formulation including a first component with >55% reflectance in a wavelengths range of 0.3 to 2.5 microns, a second component with a first thermal emissivity peak value greater than 0.85 at a first wavelength in a range of 8 to 13 microns (μm), and a third component to mechanically bind together a mixture of the first component and second component.

Van Overmeere, Quentin↗

Modular Coaxial Power Converter for High-Density Integration into Medium-Voltage Cables

This work proposes to combine the functionality benefits of power electronics with the power density benefits of medium-voltage cables to create a streamlined, high-density power electronics solution that seamlessly integrates with medium-voltage cables. Located at the ends of a medium- or high-voltage line, the proposed converter uses a cascade of coaxial power conversion cells to gradually step down the voltage, and excels in high step-down applications. By mimicking the coaxial geometry of medium-voltage cables, the converter preserves the axisymmetric electric field of the cable which, when combined with a solid insulating dielectric, provides a voltage scaling advantage over conventional planar and PCB-based converter solutions. Similar to medium voltage cables, the converter is fully passively cooled. A passive cooling strategy allows for combined installation with existing medium voltage cable systems without the added cost, maintenance needs, infrastructure, and reliability concerns associated with active cooling systems. The scalability of the modular structure in combination with the integration benefits provide a flexible power electronics system that can adapt to the evolving demands of the grid.

coaxial power conversion cells↗

Simple device modification simultaneously enhances indoor passive evaporative cooling power and duration

Passive evaporative cooling from a damp cloth or vessel can be used for localized cooling of perishables such as food and medicine, drinking water, and even people. Such applications have two key objectives, which are normally in tension with each other: minimizing the water consumption rate and maximizing the cooling (steady-state temperature swing between the cool cloth and the warm surroundings). Here, we present a simple device that delivers higher performance in both metrics simultaneously by adding a perforated aluminum foil sheet suspended over a stagnant air layer to thermally shield the evaporating surface while also facilitating mass transfer. Experimental results demonstrate a simultaneous 10%–25% increase in temperature swing and 2–3× reduction in water consumption rate as compared to conventional evaporative cooling. This improvement is achieved through careful modeling to optimize the coupled heat and mass transfer through the airgap (thermally insulating and vapor permeable) and perforated foil (infrared reflective and vapor permeable).

Chen, Sarah Mizuno↗

Eco-friendly passive radiative cooling using recycled packaging plastics

Passive daytime radiative cooling, requiring zero external energy consumption, is a promising cooling strategy achieved by simultaneously reflecting solar irradiance and thermally radiating heat into the cold outer space (~3 K) through the atmospheric transparency window. However, current materials for passive radiative cooling face huge challenges, such as complicated fabrication approaches, expensive raw materials, and environmental requirements for practical applications. In line with the urgent need for plastic recycling to curb global environmental pollution, the recycled plastics are used to fabricate a passive radiative cooling material. Herein, the foam-paper composite (FPC) with excellent self-cooling capability is fabricated by a simple crushing-and-mixing procedure using recycled polystyrene (PS) foam and printer paper. The superhydrophobic PS foam particles not only protect the FPC from water damage for field applications but also reinforce its solar reflectivity via their porous structure. The cellulose fibers in printer paper can efficiently emit infrared thermal radiation into the cold outer space and bond dispersed PS foam particles together, further increasing its mechanical strength. The combination of highly diffusely reflective PS foam particles and fiber-based printer paper results in a reflectivity of 96% in the solar spectrum, a sub-ambient cooling performance of 8.4 degrees C, and a maximum radiative cooling power of 90 W/m2 during a 24-h cycle. Meanwhile, the FPC with high humidity can maintain its high solar reflectivity, which promotes its application in humid subtropical areas. Further, the low material cost and ease of fabrication will provide a path for effective daytime radiative cooling, especially in less developed areas.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Sensitivity Analyses of Natural Convection in the AP1000 Passive Containment Cooling System Following LBLOCA Using CFD

The AP1000 power plant has implemented multiple layers of passive safety systems to enhance reactor safety and ensure system integrity during postulated scenarios, such as loss of coolant accident (LOCA) and main steam line break (MSLB). Among these, the passive containment cooling system (PCCS) is a safety-related system designed to prevent the containment from exceeding the design limits of both pressure and temperature following a postulated design basis accident, by transferring heat from the steel containment vessel to the atmosphere. During LOCA, natural air convection plays a vital role in removing heat from the steel containment vessel to the atmosphere. This is integrated with the condensate film from the Passive Containment Cooling Water Storage Tank (PCCWST). Air natural convection is also the only heat removal mechanism after the dry-out of the PCCWST and during the loss of shutdown decay heat removal (LOSDHR) event. Therefore, it is essential to investigate the thermal hydraulics behavior of the containment under transient conditions to ensure its safety and integrity. This paper presents a simplified CFD/ANSYS FLUENT model developed to analyze the impact of different parameters, such as air relative humidity, air temperature, and steel containment temperature, on the natural convection capability to remove the decay heat following LOCA. The model aims to examine the thermal behavior of the containment and provides a comprehensive understanding of the system's natural convection capability during postulated accidents. The results obtained from the model can be used to improve the safety and integrity of the containment system and provide valuable insights for future research in the field.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The X-ray Integral Field Unit at the end of the Athena reformulation phase

The Athena mission entered a redefinition phase in July 2022, driven by the imperative to reduce the mission cost at completion for the European Space Agency below an acceptable target, while maintaining the flagship nature of its science return. This notably called for a complete redesign of the X-ray Integral Field Unit (X-IFU) cryogenic architecture towards a simpler active cooling chain. Passive cooling via successive radiative panels at spacecraft level is now used to provide a 50 K thermal environment to an X-IFU owned cryostat. 4.5 K cooling is achieved via a single remote active cryocooler unit, while a multi-stage Adiabatic Demagnetization Refrigerator ensures heat lift down to the 50 mK required by the detectors. Amidst these changes, the core concept of the readout chain remains robust, employing Transition Edge Sensor microcalorimeters and a SQUID-based Time-Division Multiplexing scheme. Noteworthy is the introduction of a slower pixel. This enables an increase in the multiplexing factor (from 34 to 48) without compromising the instrument energy resolution, hence keeping significant system margins to the new 4 eV resolution requirement. This allows reducing the number of channels by more than a factor two, and thus the resource demands on the system, while keeping a 4’ field of view (compared to 5’ before). Here, in this article, we will give an overview of this new architecture, before detailing its anticipated performances. Finally, we will present the new X-IFU schedule, with its short term focus on demonstration activities towards a mission adoption in early 2027.

Peille, Philippe [Centre National d’Etudes Spatial↗

Thermal Modeling and Limitations for Power Electronics Embedded in Medium-Voltage Cables

As next-generation energy technologies gain traction and power demand increases, the existing electrical infrastructure faces significant stress, prompting innovative solutions to enhance the grid's capacity and lifespan. This work explores the possibility of embedding medium-voltage (MV) power electronics directly inline with the cable, and the resulting thermal challenges. Since the majority of power distribution cables installed in the U.S. are passively cooled, the work focuses primarily on passive cooling, with an emphasis on the limitations of axial heat spreading within the cable. To date, literature on axial spreading of high incident heat loads on cables and cable environments is limited, typically reporting cases with <10 W of incident heat load. This work will explore the considerations, limits, and tradeoffs of cable-embedded heat loads significantly larger than the cable losses. Both external and internal effects are modeled analytically in nondimensional terms via a Biot number analysis, allowing fundamental limits and tradeoffs to be derived. The work culminates in the design and experimental validation of a cable-embedded thermal system capable of passively dissipating 300 W of heat from a coaxial SiC mosfet switch module over a length of 20 cm, thus validating the possibility of MV cable-embedded power electronics from a thermal standpoint.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Decoupling absorption and radiative cooling in mid-wave infrared bolometric elements

We present a spectrally selective, passively cooled mid-wave infrared bolometric absorber engineered to spatially and spectrally decouple infrared absorption and thermal emission. The structure leverages an antenna-coupled metal–insulator–metal resonance for mid-wave infrared normal incidence photon absorption and a long-wave infrared optical phonon absorption feature, aligned closer to peak room temperature thermal emission. The phonon-mediated resonant absorption enables a strong long-wave infrared thermal emission feature limited to grazing angles, leaving the mid-wave infrared absorption feature undisturbed. The two independently controlled absorption/emission phenomena demonstrate decoupling of the photon detection mechanism from radiative cooling and offer a new design approach enabling ultra-thin, passively cooled mid-wave infrared bolometers.

Ware, Alexander (ORCID:0009000256937727)↗

All-day passive radiative cooling using common salts

An infrared transparent foam made from inexpensive salts was developed enabling sub-ambient cooling of underlying surfaces for a full 24 hour cycle. This work showcases how non-convetional materials may be used for passive day-time radiative cooling.

36 MATERIALS SCIENCE↗

COMPUTATION FLUID DYNAMICS ANALYSIS FOR GENERIC SMALL MODULAR REACTOR CONTAINMENT SEPARATE EFFECTS TEST

It is desirable for fourth-generation Small Modular Reactors to be passively cooled in standard and accident operations. Passive Containment Cooling Systems can reject heat from the containment structure, without using pumps or blowers. The targeted design containment structure is a large, domed, stainless steel, cylindrical vessel. In a postulated Design Basis Accident, steam will flash inside containment. Steam condensation occurs on the inner containment wall and transfers heat through the steel containment into a large body of water known as the annular reservoir (AR) surrounding the vessel serving as the ultimate heat sink. Natural circulation drives the flow in the AR and heat will be released to the environment by evaporation of water. Unique containment geometry requires a separate effects test (SET) facility for the verification and validation of the computer code and evaluation model development and assessment for reactor licensing efforts. In this study, STAR-CCM+, a computational fluid dynamics (CFD) code was used to inform the decision-making process on the design of the SET. The CFD simulation modeled, a two-phase turbulent flow with fluid film development and heat transfer for different containment geometries. The Reactor Excursion and Leak Analysis Program will also be used in a code-to-code verification against the CFD results.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Retrofitting Buildings with Solar-Reflective Roofs and Walls and its Impact on Peak Power Demand

Buildings are a major consumer of electricity in the United States and a significant portion of the consumption comes from heating, ventilation, and air-conditioning (HVAC) applications. Passive cooling strategies in the building envelope help to reduce the energy consumption for HVAC as well as peak electricity demand. Although being one of the most cost-effective passive cooling strategies, modern reflective roofing and reflective exterior wall technology is not well documented for its impact on peak demand. This study utilized whole building energy simulations on residential and commercial building prototype models to quantify the impact of cool roofs and cool exterior walls. The analysis was performed in three climate zones with varying insulation levels and solar reflectances for roofs and exterior walls. For both the residential and commercial buildings, the baseline building had a roof solar reflectance value of 0.10 and an exterior wall solar reflectance value of 0.25. The results from the simulations show that roofs and exterior walls with higher reflectance values increase cooling energy savings but can also increase heating energy consumption. The impact of changes in solar reflectances was greater in buildings with low roof/wall insulation levels compared to roofs/walls with higher insulation levels. A baseline for the simulations was set with the roof and exterior wall solar reflectances set at 0.1 and 0.25, respectively and simulations having varying roof and exterior wall thermal resistances were compared to the baselines.

14 SOLAR ENERGY↗

Printable, emissivity-adaptive and albedo-optimized covering for year-round energy saving

Radiative cooling uses high-emissivity materials to passively cool the surface of outdoor objects, such as building roofs on hot days. The issue of overcooling with this technology on cold days can be addressed by structures with thermal emissivity that is adaptive to temperature. Despite recent advances in temperature-adaptive structures, great challenges remain in their fabrication feasibility and unoptimized solar heating that may override the radiative cooling benefit. Here, in this work, we develop a printable, emissivity-adaptive and albedo-optimized covering (PEAC) based on recyclable materials with roll-to-roll fabrication. A PEAC automatically switches its sky-window emissivity from 0.25 to 0.85 when the surface temperature exceeds a pre-set transition temperature, delivering an albedo optimized for maximal year-round energy saving or thermal comfort in a given climate.

36 MATERIALS SCIENCE↗

Geologic Seawater Air Conditioning (GeoSWAC) System: Resource Assessment and Techno-Economic Evaluation in Puerto Rico

Puerto Rico's hot, humid climate drives a high and persistent demand for cooling, straining an aging and fuel-dependent energy grid while increasing peak electricity loads. Much of this challenge stems from inefficient air-conditioning systems operating in buildings without passive cooling design, making cooling both costly and vulnerable to disruption - especially during hurricanes. To address these issues, researchers evaluated a new alternative called Geologic Seawater Air Conditioning (GeoSWAC), which uses inland wells connected to naturally cold, deep seawater. By avoiding long offshore pipelines and energy-intensive refrigeration cycles, GeoSWAC can cut electricity use by 75-90%, reduce environmental impacts, and operate more reliably during power outages. A case study at the University of Puerto Rico's Rio Piedras campus found that GeoSWAC could deliver significantly lower levelized costs of cooling, reduced operational expenses, and improved water conservation compared to the campus's existing chilled-water plant. The system offers key advantages - including access to a constant cold heat sink, low pumping requirements, and enhanced resilience - for coastal regions such as Puerto Rico, the broader Caribbean, and Florida. However, its effectiveness depends heavily on site-specific geological conditions, such as subsurface connectivity and aquifer characteristics, which require detailed investigation. Future research should refine hydrogeological models, conduct performance and economic analyses, and address regulatory and permitting frameworks to support broader adoption of this promising technology.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessment of Sodium Thermal Stratification Models Utilizing the TSTF Benchmark

As a result of certain transient scenarios, a thermally stratified layer of liquid sodium can develop in the bulk coolant volumes of a sodium-cooled fast reactor (SFR). In addition to the effects a stratification layer has on the temperature of the heat transport system, a stratification layer can also influence the transition to and establishment of natural circulation flow, which plays an important role in passive cooling and the inherent safety of a pool-type SFR. Therefore, the ability to accurately capture thermal stratification phenomena is important when demonstrating the safety basis of a pool-type SFR during transient sequences. The present work assesses various computational models with different fidelities in their ability to predict thermal stratification in the upper plenum of an SFR. Each computational model will be assessed using the data generated at the Thermal Stratification Test Facility (TSTF) located at the University of Wisconsin-Madison. Using measured flow rate and inlet temperature data, the measured temperature distributions of the tests are compared to the predictions of the lumped volume-based models in SAS4A/SASSYS-1, a 1D-based model in SAM, and a 3-D computational fluid dynamics (CFD) model using STAR-CCM+. The relative performance of the various computational methods is assessed with respect to key metrics such as bulk coolant temperature distribution and plenum exit temperature. A total of eight tests are analyzed, covering different combinations of flow rates (3 and 10 GPM) and upper internal structure (UIS) configurations (none, solid, porous, and open) The perfect mixing model of SAS4A/SASSYS-1 provides the highest accuracy when the flow rate is high and there is no UIS in the test vessel, as high flow rate injection promotes thermal mixing of the sodium in the test vessel. For most of the analyzed tests, the stratified volume model of SAS4A/SASSYS-1 is able to predict the delay in the outlet temperature drop and temperature distribution in the test vessel by a small number of layers to represent thermal stratification. However, the stratified volume model can only simulate a maximum of three temperature layers within a volume and when a layer approaches the elevation of the outlet, the predicted outlet temperature can demonstrate rapid, non-physical changes. The 1-D axial mixing model of SAM provides results that agree reasonably well with the measured data in the prediction of the temporal evolution of the outlet temperature with the exception of the case with a high flow rate and no UIS. The SAM 1-D model has a similar level of accuracy to CFD results when it comes to predicting the outlet temperature. CFD shows overall good agreement in predicting the temperature distribution in the test vessel and outlet temperature. As CFD can model the test vessel geometry in detail, it performs well in the cases of complex geometries such as tests that included a UIS and internal flow through the UIS resulting in active mixing of the coolant in the test vessel. Each of the models discussed in the present work has the potential to be useful during the various stages of reactor design, analysis, and licensing. The lumped-volume approach can be applied for fast turnaround safety calculations to obtain overall reactor behavior during transients. The 1-D models provide improved accuracy when stratification is expected for a relatively low increase in the computational cost. The CFD model can be utilized for confirmatory analysis of the 1-D model, when experimental measurements are not available.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SAM Finite Volume Method Development Status Update: GCR Application, Restart, and MultiApp

The System Analysis Module (SAM) is being developed as a modern system analysis code for advanced non-light-water-reactor safety analysis under the U.S. DOE NEAMS program. Previous feasibility studies have demonstrated that a staggered-grid finite volume method (SG-FVM), implemented under the MOOSE framework, can deliver more than an order of magnitude speedup over the existing continuous Galerkin finite element method (CG-FEM) solver for liquid-cooled, incompressible but thermally expandable flow systems. This work extends the previous effort to compressible, gas-cooled reactor applications, where pressure couples directly into the mass equation adding additional nonlinearity into the equation system. New code capabilities are implemented for pebble bed high-temperature gas-cooled reactor (PB-HTGR) analysis, including a pebble bed CoreChannel component, built-in pebble bed effective thermal conductivity model and channel-to-channel crossflow model. The capabilities are tested, benchmarked, and demonstrated for problems with increased level of model and physical complexities, including the HTTU effective thermal conductivity test, the SANA passive cooling test, and a demonstration case using the GPBR200 reactor design covering steady-state operation, DLOFC and PLOFC transients. Across all cases, the SG-FVM solver demonstrated strong robustness and efficiency, and the solutions agree well with reference results and data. The finding of this work proves that SG-FVM is a viable and efficient solver pathway for compressible, gas-cooled reactor system analysis in SAM. In addition, work has been done to successfully support SAM-FVM recover/restart code feature that is essential to reactor safety analysis applications, and MultiApp code feature that is essential to multi-scale and multi-physics simulations. In summary, this work continued from previous feasibility studies, and further demonstrated that the SG-FVM will serve as a strong foundation for SAM’s advanced solver algorithm for future deployment.

Zou, Ling↗