Neutron dosimetry in low-earth orbit using passive detectors

This paper summarizes neutron dosimetry measurements made by the USF Physics Research Laboratory aboard US and Russian LEO spacecraft over the past 20 years using two types of passive detector. Thermal/resonance neutron detectors exploiting the 6Li(n,T) alpha reaction were used to measure neutrons of energies <1 MeV. Fission foil neutron detectors were used to measure neutrons of energies above 1 MeV. While originally analysed in terms of dose equivalent using the NCRP-38 definition of quality factor, for the purposes of this paper the measured neutron data have been reanalyzed and are presented in terms of ambient dose equivalent. Dose equivalent rate for neutrons <1 MeV ranged from 0.80 microSv/d on the low altitude, low inclination STS-41B mission to 22.0 microSv/d measured in the Shuttle's cargo bay on the highly inclined STS-51F Spacelab-2 mission. In one particular instance a detector embedded within a large hydrogenous mass on STS-61 (in the ECT experiment) measured 34.6 microSv/d. Dose equivalent rate measurements of neutrons >1 MeV ranged from 4.5 microSv/d on the low altitude STS-3 mission to 172 microSv/d on the ~6 year LDEF mission. Thermal neutrons (<0.3 eV) were observed to make a negligible contribution to neutron dose equivalent in all cases. The major fraction of neutron dose equivalent was found to be from neutrons >1 MeV and, on LDEF, neutrons >1 MeV are responsible for over 98% of the total neutron dose equivalent. Estimates of the neutron contribution to the total dose equivalent are somewhat lower than model estimates, ranging from 5.7% at a location under low shielding on LDEF to 18.4% on the highly inclined (82.3 degrees) Biocosmos-2044 mission. c2001 Elsevier Science Ltd. All rights reserved.

Flight Experiment↗

Measurement of heavy cosmic rays above 20 GeV/n in passive detectors - Preliminary results from JACEE-3

It is pointed out that the JACEE-3 experiment combined electronic counters and an emulsion chamber to study nucleus-nucleus interactions between 20 and 100 GeV/n. In the present paper, a description is given of the use of the passive detector stack. The electronic position detectors facilitate the event location, taking into account a determination of the incident angles. CR-39 plastic plates were placed just below the proportional counters to enhance tracking accuracy. The JACEE-3 emulsion chamber consists of three parts, including the charge module, the target module, and the calorimeter module. The charge module is mainly used in track identification. The obtained results are also discussed, giving attention to event number and tracking efficiency, interaction measurements, and the inelasticity distribution.

Burnett, T. H.↗

Sub-THz passive detector performance evaluation with RadiaBeam photoinjector

Wakefield accelerators, based on THz and mm-wave structures, promise to reach the highest energies in record small footprints. However, operation at such frequencies is associated with strong generation of dipole modes that can destroy the beams, which requires controlling the electron beam position at the micron scale. The existing conventional techniques for electron beam position monitoring are not applicable for sub-THz structures due to the space constraints. Here, on the other hand, if dipole modes amplitudes can be measured precisely at different planes, one can derive beam position relative to the central axis. For such a technique a reliable and cost-effective sensor capable of operating in high repletion rate regime is required. In this paper we review the experimental evaluation of a passive sensor candidate for such applications using RadiaBeam 4.5 MeV photoinjector.

Accelerator↗

Experiment definition and integration study for the accommodation of giant, passive detector of Exotic Particles In the Cosmic Rays (EPIC) payload on shuttle/spacelab missions

The feasibility of the design, construction, launch and retrieval of a hinged 15 ft by 110 ft the platform containing an array of interleaved CR-39 and Lexan track-recording detectors to be placed into circular orbit by space shuttle is assessed. The total weight of the detector assembly plus supporting structure and accessories is 32,000 pounds. The modular construction permits as little as one fourth of the payload to be exposed at one time. The CR-39 detector has sensitivity adequate to detect and study cosmic rays ranging from minimum ionizing iron-group nuclei to the heaviest elements. The detectors will survive a one year exposure to trapped protons without losing their high resolution. Advantages include low cost, huge collecting power (approximately 150 sq m) as well as the high resolution previously attainable only with electronic detectors.

Price, P. B.↗

Neutron fluences and dose equivalents measured with passive detectors on LDEF

Neutron fluences were measured on LDEF in the low energy (< 1 MeV) and high energy (> 1 MeV) ranges. The low energy detectors used the 6Li(n,alpha)T reaction with Gd foil absorbers to separate thermal (< 0.2 eV) and resonance (0.2 eV-1 MeV) neutron response. High energy detectors contained sets of fission foils (181Ta, 209Bi, 232Th, 238U) with different neutron energy thresholds. The measured neutron fluences together with predicted spectral shapes were used to estimate neutron dose equivalents. The detectors were located in the A0015 and P0006 experiments at the west and Earth sides of LDEF under shielding varying from 1 to 19 g/cm2. Dose equivalent rates varied from 0.8 to 3.3 microSv/d for the low energy neutrons and from 160 to 390 microSv/d for the high energy neutrons. This compares with TLD measured absorbed dose rates in the range of 1000-3000 microGy/d near these locations and demonstrates that high energy neutrons contribute a significant fraction of the total dose equivalent in LEO. Comparisons between measurements and calculations were made for high energy neutrons based on fission fragment tracks generated by fission foils at different shielding depths. A simple 1-D slab geometry was used in the calculations. Agreement between measurements and calculations depended on both shielding depth and threshold energy of the fission foils. Differences increased as both shielding and threshold energy increased. The modeled proton/neutron spectra appeared deficient at high energies. A 3-D model of the experiments is needed to help resolve the differences.

LDEF Project↗

Measurements of LET distribution and dose equivalent onboard the Space Shuttle IML-2 (STS-65) and S/MM#4 (STS-79)

Space radiation dosimetry measurements have been made onboard the Space Shuttle STS-65 in the Second International Microgravity Laboratory (IML-2: 28.5 degrees x 300 km: 14.68 days) and the STS-79 in the 4th Shuttle MIR mission (S/MM#4: 51.6 degrees x 300-400km: 10.2 days). In these measurements, three kinds of detectors were used; one is a newly developed active detector telescope called "Real-time Radiation Monitoring Device (RRMD-I for IML-2 and RRMD-II with improved triggering system for S/MM#4)" utilizing silicon semi-conductor detectors and the other detectors are conventional passive detectors of thermoluminescence dosimeters (TLDs) and CR-39 plastic track detectors. The main contribution to dose equivalent for particles with LET > 5.0 keV/micrometer (IML-2) and LET > 3.5 keV/micrometer (S/MM#4) is seen to be due to galactic cosmic rays (GCRs) and the contribution of the South Atlantic Anomaly (SAA) is less than 5% (IML-2: 28.5 degrees x 300 km) and 15% (S/MM#4: 51.6 degrees x 400 km) in the above RRMD LET detection conditions. For the whole LET range (> 0.2 kev/micrometer) obtained by TLDs and CR-39 in these two typical orbits (a small inclination x low altitude and a large inclination x high altitude), absorbed dose rates range from 94 to 114 microGy/day, dose equivalent rates from 186 to 207 microSv/day and average quality factors from 1.82 to 2.00 depending on the locations and directions of detectors inside the Spacelab at the highly protected IML-2 orbit (28.5 degrees x 300 km), and also, absorbed dose rates range from 290 to 367 microGy/day, dose equivalent rates from 582 to 651 microSv/day and average quality factors from 1.78 to 2.01 depending on the dosimeter packages around the RRMD-II "Detector Unit" at the S/MM#4 orbit (5l.6 degrees x 400km). In general, it is seen that absorbed doses depend on the orbit altitude (SAA trapped particles contribution dominant) and dose equivalents on the orbit inclination (GCR contribution dominant). The LET distributions obtained by two different types of active and passive detectors, RRMDs and CR-39, are in good agreement for LET of 15 - 200 kev/micrometer and difference of these distributions in the regions of LET < 15 kev/micrometer and LET > 200 kev/micrometer can be explained by considering characteristics of CR-39 etched track formation especially for the low LET tracks and chemical etching conditions.

manned↗

Evaluation of the Stability of Edge-Passivated CZTS Radiation Detectors

CdZnTeSe (CZTS) is a next gen replacement room temperature radiation detector that solves common issues with modern CZT detectors. • Surface states can trap radiation induced carriers and can act as leakage current pathways requiring detectors to passivated for optimal performance. • In this work, we seek to identify the best passivation technique for CZTS detectors.

KLEPPINGER, JOSHUA↗

Physical dosimetric evaluations in the Apollo 16 microbial response experiment

Texts of high-energy multicharged particle, ultraviolet light, and galactic irradiation fluxes on exposed biological specimens aboard Apollo 16 are described. Passive nuclear track detectors, passive dosimeters, and thermoluminescent dosimeters, respectively, were used for the measurements. Biological phenomena studied ranged from lipolytic alpha toxin production in Bacillus thuringiensis to animal tissue invasion (of human hair by Trichophyton terrestre). Fluxes observed were lower than those recorded by detectors located in the Biostack and in the passive personnel dosimeters worn by the astronauts, suggesting a greater average shielding in the latter two environments.

Taylor, G. R.↗

Development of passive radiation detectors of improved sensitivity

The future development of a solid track high energy particle detector is discussed. The goal is to improve the sensitivity and lower the threshold of the detector. One most widely used material for such purpose is a plastic commercially known as CR-39. A scheme is presented which involves changing the formula of the monomer, diethylene glycol-bis-allyl carbonate. This is to be accomplished by substituting some heteroatoms for H and substituting sulfur atoms for oxygen in the ether linkages. Use of a new plasticizer to make the etched surface clearer than what has been accomplished as of today is suggested. Possible improvement in acquiring better tracks and increasing the ratio of V sub T/V sub B was planned. This is to be accomplished by changing the composition of the etchants, etching time, and etching temperature.

Chakrabarty, M. R.↗

High resolution Cerenkov and range detectors for balloon-borne cosmic-ray experiment

A combination of an active Cerenkov detector and passive range detectors is proposed for the high resolution measurement of isotopic composition in the neighborhood of iron in the galactic cosmic rays. A large area (4,300 sq cm) Cerenkov counter and passive range detectors were tested. Tests with heavy ions (2.1 GeV/amu C-12, 289 MeV/amu Ar-40, and 594 MeV/amu Ne-20) revealed the spatial uniformity of response of the Cerenkov counter to be better than 1% peak-to-peak. Light collection efficiency is independent of projectile energy and incidence angle to within at least 0.5%. Passive Lexan track recorders to measure range in the presence of the nuclear interaction background which results from stopping particles through 0.9 interaction lengths of matter were also tested. It was found that nuclear interactions produce an effective range straggling distribution only approximately 75% wider than that expected from range straggling alone. The combination of these tested techniques makes possible high mass resolution in the neighborhood of iron.

Ahlen, S. P.↗

Thermal Analysis and Design Considerations of NASA's Passively Cooled 35K Next Generation Space Telescope (NGST)

The configuration and thermal analyses of NASA's Next Generation Space Telescope (NGST) Yardstick concept utilizing a novel sunshield approach for passive cooling is described. The NGST mission concept of a large aperture optical telescope passively cooled to less than 40 K and instrument detectors passively cooled to below 30 K is unique from any other mission flown to date. Achieving such a low operational temperature requires reducing by a factor of several thousand the internal heat dissipation and environmental heating of the telescope. The techniques for achieving these requirements, i.e. orbit selection, configuration, etc., along with the supporting thermal analyses are described.

Parrish, Keith↗

Description of the COMRADE experiment

The COMRADE experiment is designed to return minimally degraded particles to earth along with complete in situ information concerning mass, velocity, and trajectory of encountered particles. The objectives of the program are very diverse. A set of flight-tested active detectors will be combined in an array to identify some of the physical properties of an incident grain, e.g., velocity vector, momentum, and mass. The use of passive detectors gives access to the chemical and isotopical properties of the grains in the micrometer size range. We are concerned simultaneously with a destructive capture, using metallic collectors, and a nondestructive capture, using a new low-density target in which the impacting grains stop, practically intact. The primary objectives for this mission are (1) to identify the particle remnants of the micrometer-sized grains having impacted on purposely designed metallic collectors, for complete and detailed chemical, isotopic, and organic analysis, thereby determining grain composition as well as the existence of organic and inorganic molecules, to be related with the possible cometary origin of the grains showing an extraterrestrial signature; (2) to return captured intact particles to earth for complete and detailed chemical, isotopic, spectral, mineralogical, and organic analysis, thereby determining grain composition as well as the existence of organic and inorganic molecules; and (3) to capture micrometer/submicrometer dust grains in a manner that ensures minimal particle degradation and guarantees state-of-the-art confidence in measurement of the in situ particle parameters including trajectory, velocity vector, mass, and flux distributions.

Borg, Janet↗

Ames collaborative study of cosmic ray neutrons

The results of a collaborative study to define both the neutron flux and the spectrum more precisely and to develop a dosimetry package that can be flown quickly to altitude for solar flare events are described. Instrumentation and analysis techniques were used which were developed to measure accelerator-produced radiation. The instruments were flown in the Ames Research Center high altitude aircraft. Neutron instrumentation consisted of Bonner spheres with both active and passive detector elements, threshold detectors of both prompt-counter and activation-element types, a liquid scintillation spectrometer based on pulse-shape discrimination, and a moderated BF3 counter neutron monitor. In addition, charged particles were measured with a Reuter-Stokes ionization chamber system and dose equivalent with another instrument. Preliminary results from the first series of flights at 12.5 km (41,000 ft) are presented, including estimates of total neutron flux intensity and spectral shape and of the variation of intensity with altitude and geomagnetic latitude.

Hewitt, J. E.↗

Radiation environment of Spacelab-1

The results of passive and active radiation measurements on Spacelab-1 are reported. Spacelab-1 was flown on the STS-9 mission, orbited at an altitude of 241 km, with an inclination of 57 deg and 240 hours of flight time. Approximately thirty passive detectors deployed inside the module, in the access tunnel, and outside on the pallet made possible the radiation measurements. The various forms of radiation measured were a low linear energy transfer component ranging from 94 to 133 mrads inside the module (average dose rate of 10.0 mrads/day; about twice the rate of earlier shuttle flights), an average mission dose-equivalent rate of about 18.5 mrem/day (six times higher than earlier flights), accumulated doses of 125 and 128 mrads and a yield of 17 and 12 mrads for passages through the South Atlantic Anomaly. Spacelab-1, because of its low altitude and short duration, was relatively benign in terms of total radiation dose. Some of the measurements such as high-LET particles and neutrons have biological significance and potential effects on future experiments.

Benton, E. V.↗

First biological and dosimetric results of the free flyer biostack experiment AO015 on LDEF

The main objectives of the Biostack Experiment are to study the effectiveness of the structured components of the cosmic radiation to bacterial spores, plant seeds, and animal cysts for a long duration spaceflight and to get dosimetric data such as particle fluences and spectra and total doses for the Long Duration Exposure Facility orbit. The configuration of the experiment packages allows the localization of the trajectory of the particles in each biological layer and to correlate the potential biological impairment or injury with the physical characteristics of the responsible particle. Although the Biostack Experiment was designed for a long duration flight of only nine months, most of the biological systems show a high hatching or germination rate. Some of the first observations are an increase of the mutation rate of embryonic lethals in the second generation of Arabidopsis seeds, somatic mutations, and a reduction of growth rates of corn plants and a reduction of life span of Artemia salina shrimps. The different passive detector systems are also in a good shape and give access to a proper dosimetric analysis. The results are summarized, and some aspects of future analysis are shown.

Reitz, G.↗

Summary of ionizing radiation analysis on the Long Duration Exposure Facility

The ionizing radiation measurements flown on the Long Duration Exposure Facility (LDEF) were contained in 15 experiments which utilized passive detectors to pursue objectives in astrophysics and to measure the radiation environment and dosimetric quantities. The spacecraft structure became sufficiently radioactive to permit additional important studies. The induced activity allows extensive radiation mapping in the structure, and independent comparison with experiment dosimetric techniques, and significant studies of secondary effects. The long exposure time, attitude stability, and number and types of measurements produced a unique and critical set of data for low Earth orbit that will not be duplicated for more than a decade. The data allow an unprecedented test, and improvement if required, of models of the radiation environment and the radiation transport methods that are used to calculate the internal radiation and its effects in spacecraft. Results of measurements in the experiments, as well as from radioactivity in the structure, have clearly shown effects from the directional properties of the radiation environment, and progress was made in the dosimetric mapping of LDEF. These measurements have already influenced some Space Station Freedom design requirements. Preliminary results from experiments, reported at this symposium and in earlier papers, show that the 5.8 years exposure considerably enhanced the scientific return of the radiation measurements. The early results give confidence that the experiments will make significant advances in the knowledge of ultra heavy cosmic rays, anomalous cosmic rays, and heavy ions trapped in the radiation belts. Unexpected phenomena were observed, which require explanation. These include stopping iron group ions between the energy ranges anticipated for anomalous and galactic cosmic rays in the LDEF orbit. A surprising concentration of the Be-7 nuclide was discovered on the 'front' surface of LDEF, apparently transported up from the stratosphere with exceptional efficiency.

Parnell, T. A.↗