Search NASA⌕ Search

SEARCH · Search NASA

Results for “passive detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Sub-THz passive detector performance evaluation with RadiaBeam photoinjector

Wakefield accelerators, based on THz and mm-wave structures, promise to reach the highest energies in record small footprints. However, operation at such frequencies is associated with strong generation of dipole modes that can destroy the beams, which requires controlling the electron beam position at the micron scale. The existing conventional techniques for electron beam position monitoring are not applicable for sub-THz structures due to the space constraints. Here, on the other hand, if dipole modes amplitudes can be measured precisely at different planes, one can derive beam position relative to the central axis. For such a technique a reliable and cost-effective sensor capable of operating in high repletion rate regime is required. In this paper we review the experimental evaluation of a passive sensor candidate for such applications using RadiaBeam 4.5 MeV photoinjector.

Accelerator↗

Evaluation of the Stability of Edge-Passivated CZTS Radiation Detectors

CdZnTeSe (CZTS) is a next gen replacement room temperature radiation detector that solves common issues with modern CZT detectors. • Surface states can trap radiation induced carriers and can act as leakage current pathways requiring detectors to passivated for optimal performance. • In this work, we seek to identify the best passivation technique for CZTS detectors.

KLEPPINGER, JOSHUA↗

Detector Performance on Surface Passivation and its Long-Term Stability

Surface passivation is an ideal technique to prepare the surfaces of fabrication Cadmium Zinc Telluride (CZT) and related semiconductor devices such as Cadmium Zinc Tellurium Selenide (CZTS). Surface passivation techniques reduce the effects of aging in the detector [1]. Surface performance effects on material performance can result in fluctuations in energy resolution over time (such as periods of a year or more). The long-term stability of surface passivation with Potassium Hydroxide (KOH) was observed with measurement of 1) current (nano Amp) vs voltage (V) and 2) spectral response and energy resolution throughout the years. Three CZTS detector samples of M2, M3, and M4 were examined using a photomultiplier tube and voltage amplifier. The Bridgman technique is used to grow the CZTS used in this study.

Johnson, Kirsten [Morgan State Univ., Baltimore, M↗

Effect of Surface Passivation of CZTS Semiconductor Detector on Leakage Current

Cadmium Zinc Telluride Selenide (CdZnTeSe or CZTS)has shown high crystal quality for room-temperature gamma ray and X-ray detection applications compared to Cadmium Zinc Telluride (CdZnTe or CZT) [1,2]. Current applications of CZT include medical imaging, homeland security, and X-ray and gamma ray astronomy [3]. CZST has similar potential applications

Kangethe, Anthony [Morgan State Univ., Baltimore, ↗

Conceptual design study of neutron detectors for safeguards measurement of an irradiated pebble

Nuclear material control and accounting (MC&A) of pebble-bed reactors (PBRs) is challenging because a PBR utilizes hundreds of thousands of identical, unmarked pebbles that are continuously recirculated through the core. To develop tools that enable the implementation of international safeguards, especially in the context of MC&A of spent pebbles, we designed and simulated three neutron detection concepts to determine fissile content in individual pebbles: a differential die-away (DDA) detector, a californium interrogation prompt neutron (CIPN) detector, and a passive neutron albedo reactivity (PNAR) detector using Monte Carlo calculations. Burnup calculations were performed on the spent pebbles from the PBMR-400 classic PBR. The varying neutron and gamma source terms, and isotopic compositions in the spent pebbles calculated at various burnup levels were used in the neutron detector models. DDA was found to be sensitive to the number of passes a pebble has had through the core and to the fissile content contained in a spent pebble. Optimization in the DDA design further increased the neutron count rates and thus reduced counting uncertainty. Meanwhile, passive neutron counting using the same detector body could distinguish pebbles with different numbers of passes, but its response was dominated by neutron-emitting actinides and was not sensitive to fissile content. On the other hand, the PNAR technique was not viable for a single pebble but performed reasonably for a 27-pebble array, which suggested potential use for verification measurements of containers filled with 27 or more spent pebbles.

CIPN↗

CAMIS: A Cylindrical Active Mask Imaging System

Detecting and locating radiological and nuclear materials at distances of 10 m or more in urban and cluttered environments continues to pose challenges in nuclear security and proliferation detection. Previous approaches have focused on large-area radiation imaging using planar configurations of detectors and passive masks. However, these approaches suffer from limitations such as limited field-of-view (FOV) and reduced detection efficiency due to absorption in the mask. To address these limitations, we have developed the cylindrical active mask imaging system (CAMIS). This system comprises 128 NaI(Tl) (10 cm)3 detectors. These detectors are arranged in a cylindrical configuration, enabling gamma-ray imaging with a full 360° azimuthal FOV. The active mask elements within the system are arranged in a pseudorandom configuration, providing unique encoding for all incident directions within the FOV. CAMIS offers an effective detection area of approximately 1 m2 across the entire 360° FOV in the horizontal plane, achieving a mean angular resolution of 10.9° in the azimuthal direction and 12.9° in the polar direction measured by taking the full-width at half-maximum (FWHM) of a cross-section at the maximum reconstructed intensity.

Lamb, C↗

Toward Ultra‐High‐Quality‐Factor Wireless Masing Magnetic Resonance Sensing

It has recently been shown that a bolus of hyperpolarized nuclear spins can yield stimulated emission signals similar in nature to maser signals, potentially enabling new ways of sensing hyperpolarized contrast media, including most notably [1- 13 C]pyruvate that is under evaluation in over 50 clinical trials for metabolic imaging of cancer. The stimulated NMR signal emissions lasting for minutes do not require radio-frequency excitation, offering unprecedented advantages compared to conventional MR sensing. However, creating nuclear spin maser emission is challenging in practice due to stringent fundamental requirements, making practical in vivo applications hardly possible using conventional passive MR detectors. Here, in this study, we demonstrate the utility of a wireless NMR maser detector, the quality factor of which was enhanced 22-fold (to 1,670) via parametric pumping. This active-feedback technique breaks the intrinsic fundamental limit of NMR detector circuit quality factor. We show the use of parametric pumping to reduce the threshold requirement for inducing nuclear spin masing at 300 MHz resonance frequency in a preclinical MRI scanner. Indeed, stimulated emission from hyperpolarized protons was obtained under highly unfavorable conditions of low magnetic field homogeneity (T 2 * of 3 ms). Greater gains of the quality factor of the MR detector (up to 1 million) were also demonstrated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Coincidence measurements of radioxenon using passive implemented planar silicon (PIPS) detector

The Comprehensive Test Ban Treaty (CTBT) bans nuclear weapons testing and establishes the International Monitoring System (IMS) for the purpose of treaty verification. IMS is a detector network that confirms that global nuclear activity is peaceful in nature. These detector systems use β-γcoincidence measurements to characterize atmospheric samples containing radioxenon isotopes. The goal of this work is to use the system consisting of two sodium iodide detectors and two PIPSbox detectors to characterize isotopically pure samples of 131m Xe, 133m Xe, 133 Xe, and 135 Xe via β, γ, and β-γ coincidence measurements.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Charge collection in h -BN neutron detectors at elevated temperatures

Many of the neutron detector applications are in the environments with harsh conditions such as high temperatures. We report here the measurements of charge collection parameters of hexagonal boron nitride (h-BN) detectors at elevated temperatures, including the electron mobility-lifetime product (μτ) and surface recombination field (s/μ). It was found that μτ is increased, while s/μ is decreased as temperature increases. The temperature dependence of the surface recombination field (s/μ) revealed that electrons trapped in the surface states tend to thermally activate to the bulk region at higher temperatures with an activation energy of about 0.22 eV, leading to a reduction in the density of the charged surface states at elevated temperatures. Consequently, the charge collection efficiency is enhanced at elevated temperatures due to a reduced surface recombination field and increased electron mobility-lifetime product. The results suggested that h-BN neutron detectors are favorable for high temperature operation.

47 OTHER INSTRUMENTATION↗

Passive Low-Energy Nuclear-Recoil Detection with Color Centers

Crystal-damage events such as tracks and point defects have been used to record and detect radiation for a long time and recently they have been proposed as a means for dark-matter detection. Color centers can be read out optically and we propose a scheme based on selective plane illumination microscopy for micrometer-scale imaging of large volumes corresponding to kilogram mass detectors. This class of detectors would be passive and would operate at room temperature and we call this the passive low-energy optical color-center nuclear-recoil (PALEOCCENE) detection method. We apply these concepts to the detection of reactor neutrinos using coherent elastic neutrino nucleus scattering (CE ν NS). Crystal-damage formation energies are intrinsically on the order of 25 eV, resulting in similarly low nuclear-recoil thresholds. Furthermore, this would enable the observation of reactor-neutrino CE ν NS with detectors as small as 10 g. Additionally, a competitive search for spin-dependent dark-matter scattering down to a dark-matter mass of 0.3 GeV could be possible. Passive crystal detectors might also be attractive for nuclear-nonproliferation safeguards if used to monitor reactor power and to put limits on plutonium production. The passive nature and small footprint of the proposed detectors implies that these might fit well within accepted reactor-safeguards operations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The BDX-MINI detector for Light Dark Matter search at JLab

This paper describes the design and performance of a compact detector, BDX-MINI, that incorporates all features of a concept that optimized the detection of light dark matter in the MeV-GeV mass range produced by electrons in a beam dump. It represents a reduced version of the future BDX experiment expected to run at JLAB. BDX-MINI was exposed to penetrating particles produced by a 2.176GeV electron beam incident on the beam dump of Hall A at Jefferson Lab. The detector consists of 30.5 kg of PbWO 4 crystals with sufficient material following the beam dump to eliminate all known particles except neutrinos. The crystals are read out using silicon photomultipliers. Completely surrounding the detector are a passive layer of tungsten and two active scintillator veto systems, which are also read out using silicon photomultipliers. The design was validated and the performance of the robust detector was shown to be stable during a six month period during which the detector was operated with minimal access.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modeling of surface-state induced inter-electrode isolation of n -on- p devices in mixed-field and γ -irradiation environments

Position sensitive n-on-p silicon sensors will be utilized in the tracker and in the High Granularity Calorimeter (HGCAL) of the Compact Muon Solenoid (CMS) experiment at High Luminosity Large Hadron Collider (HL-LHC). The detrimental effect of the radiation-induced accumulation of positive net oxide charge on position resolution in n-on-p sensors has typically been countered by the application of isolation implants like p-stop or p-spray between n + -electrodes. In addition to the positively charged layer inside the oxide and close to the Si/SiO 2 -interface, surface damage introduced by ionizing radiation in SiO 2 -passivated silicon particle detectors includes the accumulation of trapped-oxide-charge and interface traps. A previous study of either n/γ (mixed field)- or γ-irradiated Metal-Oxide-Semiconductor (MOS) capacitors showed evidence of substantially higher introduction rates of acceptor- and donor-type deep interface traps (N it,acc/don ) in mixed-field environment. Here, in this work, an inter-pad and -strip resistance (or resistivity (ρ int )) simulation study of n-on-p sensors with and without p-stop isolation implants was conducted for both irradiation types. Higher levels of ρint showed correlation to higher densities of deep N it,acc/don , with the inter-pad isolation performance of the mixed-field irradiated sensors becoming independent of the presence of p-stop implant between the n + - electrodes up to about 100 kGy. The low introduction rates of deep N it,acc/don in γ-irradiated sensors resulted in high sensitivity of ρ int to the presence and peak doping of p-stop above the lowest dose of about 7 kGy in the study. As a consequence of the advantageous influence of radiation-induced accumulation of deep N it on the inter-electrode isolation, position sensitive n-on-p sensors without isolation implants may be considered for future HEP-experiments where the radiation is largely due to hadrons.

Akchurin, N. [Texas Tech Univ., Lubbock, TX (Unite↗

Tunnel oxide passivating contact enabled by polysilicon on ultra-thin SiO 2 for advanced silicon radiation detectors

Conventional silicon junction detectors encounter significant carrier recombination within the heavily doped p⁺ and n⁺ layers, as well as beneath the metal contact regions, creating the so-called “dead layers”, especially on the detector side. In this study, we present the tunnel oxide passivating contact with doped polysilicon on oxide, which demonstrates exceptional surface passivation and carrier selectivity. The key innovation lies in an ultra-thin (~ 1.5 nm) interfacial oxide layer that facilitates efficient majority carrier transportation via tunneling while effectively block minority carriers. Remarkably low saturation current densities, ranging from 5 to 10 fA/cm² even with the metal contact, underscore the superiority of both n-type and p-type tunnel oxide passivating contacts. In contrast, conventional p–n junction or high-low junction exhibit saturation current densities ranging from 10 to 90 fA/cm² in the studied p⁺ and n⁺ layers with surface passivation schemes due to Auger recombination and surface recombination, and 1000–6000 fA/cm² with metal contacts due to intense metal-induced recombination at the interface. These findings indicate the potential and superiority of implementing n-type tunnel oxide passivating contact on the detector side and p-type contact on the back side for advanced silicon radiation detectors. This approach would enable thorough collection of generated charge carriers along the track of incident ionizing radiation particles, leading to improved energy resolution and reduced noise levels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

$$\alpha $$-event characterization and rejection in point-contact HPGe detectors

Abstract P-type point contact (PPC) HPGe detectors are a leading technology for rare event searches due to their excellent energy resolution, low thresholds, and multi-site event rejection capabilities. We have characterized a PPC detector’s response to $$\alpha $$ α particles incident on the sensitive passivated and p $$^+$$ + surfaces, a previously poorly-understood source of background. The detector studied is identical to those in the Majorana Demonstrator experiment, a search for neutrinoless double-beta decay ( $$0\nu \beta \beta $$ 0 ν β β ) in $$^{76}$$ 76 Ge. $$\alpha $$ α decays on most of the passivated surface exhibit significant energy loss due to charge trapping, with waveforms exhibiting a delayed charge recovery (DCR) signature caused by the slow collection of a fraction of the trapped charge. The DCR is found to be complementary to existing methods of $$\alpha $$ α identification, reliably identifying $$\alpha $$ α background events on the passivated surface of the detector. We demonstrate effective rejection of all surface $$\alpha $$ α events (to within statistical uncertainty) with a loss of only 0.2% of bulk events by combining the DCR discriminator with previously-used methods. The DCR discriminator has been used to reduce the background rate in the $$0\nu \beta \beta $$ 0 ν β β region of interest window by an order of magnitude in the Majorana Demonstrator and will be used in the upcoming LEGEND-200 experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quaternary Semiconductor Cd1−xZnxTe1−ySey for High-Resolution, Room-Temperature Gamma-Ray Detection

The application of Cd0.9Zn0.1Te (CZT) single crystals, the primary choice for high-resolution, room-temperature compact gamma-ray detectors in the field of medical imaging and homeland security for the past three decades, is limited by the high cost of production and maintenance due to low detector grade crystal growth yield. The recent advent of its quaternary successor, Cd0.9Zn0.1Te1−ySey (CZTS), has exhibited remarkable crystal growth yield above 90% compared to that of ~33% for CZT. The inclusion of Se in appropriate stoichiometry in the CZT matrix is responsible for reducing the concentration of sub-grain boundary (SGB) networks which greatly enhances the compositional homogeneity and growth yield. SGB networks also host defect centers responsible for charge trapping, hence their reduced concentration ensures minimized charge trapping. Indeed, CZTS single crystals have shown remarkable improvement in electron charge transport properties and energy resolution over CZT detectors. However, our studies have found that the overall charge transport in CZTS is still limited by the hole trapping. In this article, we systematically review the advances in the CZTS growth techniques, its performance as room-temperature radiation detector, and the role of defects and their passivation studies needed to improve the performance of CZTS detectors further.

36 MATERIALS SCIENCE↗

Surface Trap Dynamics and Gamma‐Ray Detection Enhancement in Passivated FAPbBr 3 Perovskite Crystals

Perovskite‐based direct radiation detectors offer a compelling platform for room‐temperature gamma spectroscopy due to their high sensitivity, tunable optoelectronic properties, and compatibility with solution processing. While prior studies on formamidinium lead tribromide (FAPbBr 3 ) have shown that surface passivation mitigates deep trap state impact on the charge collection efficiency (CCE), the influence of surface‐based shallow traps on time‐resolved detector response remains largely unexplored. In this article, a digital signal processing (DSP) method is applied to analyze waveform rising edge dynamics in FAPbBr 3 single‐crystal detectors, identifying prompt and delayed charge collection components. Using the second derivative of the collected charge signal, the onset of shallow trap reemission is isolated, occurring 1.1 µs after carrier generation. Surface passivation suppressed deep trap states, shifting carrier occupancy toward shallower traps and extending the temporal window of delayed charge collection. This delayed contribution correlates with measurable changes in the temporal and amplitude distributions of detector events. By leveraging time‐domain filtering informed by these dynamics, a selective enhancement in signal quality and gamma peak‐to‐Compton ratio (PCR) is achieved, while preserving over 90% of photoelectric events. An improvement in the PCR to 1.80, from the original 1.09, is enabled by focusing on high collection efficiency events corresponding to reemitted carriers in the 1.1 to 3 µs range after the generation event. These results demonstrate a pathway for leveraging shallow trap dynamics to enhance spectral fidelity in time‐resolved perovskite detectors.

36 MATERIALS SCIENCE↗