Search NASA⌕ Search

SEARCH · Search NASA

Results for “passive heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Improvements to Passive Heat Removal Systems in SAS4A/SASSYS-1

Safe operation of a sodium cooled fast reactor (SFR) can be significantly aided by heat removal systems that do not rely on active power, but function using passive means. Passive heat removal from such reactors can employ systems that extract heat directly from sodium coolant by utilizing heat exchangers submerged in the coolant and natural circulation of a metal fluid sodium (or sodium potassium eutectic) to heat exchangers (generally air cooled) externally located. These types of systems are generally called Direct Reactor Auxiliary Cooling Systems (DRACS). Another type of passive heat removal system particularly suitable for pool-type SFRs relies on indirect extraction of heat by utilizing air flow in an annular region surrounding the reactor guard vessel which discharges the heat via the chimney effects to the atmosphere. These systems are generally called Reactor Vessel Auxiliary Cooling Systems (RVACS).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Orientation of heated premise in the design of insolation passive heating systems

The technique for calculating the start and end times and the direct sunlight illumination period is described. The cumulative solar radiation (SR) falling on the front surface of translucent enclosures (TE) of heated premise (HP) is found. The final design results are based on processing 4-year generalized data from the Parkent weather station.

14 SOLAR ENERGY↗

Passive heat removal in horizontally oriented micro-HTGRs

There are novel, horizontally oriented high-temperature gas-cooled micro-reactor (HTGR) designs under consideration because of their portability, simplicity, and reliable operation. These features of the micro-HTGR design can meet the fission battery attributes, such as economic, standardize, installed, unattended and reliable. Although there have been HTGR related safety studies, micro-HTGRs when horizontally oriented are expected to exhibit significantly different thermal physics. During the unavailability of helium circulation, the internal reactor core is designed to cool by block-to-block conduction and radiation, and the reactor vessel surface is cooled by the ambient air. This scenario is anticipated during the transport of the micro-HTGR in a shipping container. The conduction and radiation between the prismatic micro-HTGR blocks in the core can be influenced by variances in the thermal contacts. This work investigated the conduction within a simulated horizontal HTGR core. An experimental setup was used to validate a numerical model. The experimental setup consisted of a hexagonal assembly with scaled prismatic blocks placed within a high-temperature vacuum environment. The gaps between the blocks were well controlled and monitored. The experimental setup was designed in such a way that the temperature variation in the axial direction was minimal, such that the experiment could be observed as a 2D (r, ) heat transfer problem. The pressurized tube was equipped with Infra-Red (IR) transparent windows, and an IR camera was used to capture the spatio-temporal temperature evolution in the hexagonal block assembly during the cooldown experiments. The experimental scenario was computationally modeled with a finite element analysis (FEA) program. Once validated, the computational model was used to investigate the impact of gap conductance on overall decay heat removal. Using a conservative estimate for gap conductance value (100 W/m 2 -K) between the prismatic blocks, there is a negligible increase in temperature observed during decay heat generation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Molten Salt Reactor Passive Heat Removal System Modeling

The direct reactor auxiliary cooling system is a very robust, passive safety system that is designed to remove up to 2.36 MW of heat from the reactor during accident conditions. This report details a variety of DRACS degradation conditions and their effect on the safety of the reactor. This preliminary investigation shows that only two of the three DRACS loops are necessary to quickly suppress the decay heat produced by a newly shut down reactor. Even with a single DRACS loop operational, the maximum salt temperature observed was far below the safety specification of the plant (1173 K). When investigating the degraded performance of each DRACS loop, the short-term maximum salt temperature observed was strongly dependent on the DHX performance but was unaffected by the TCHX performance. However, even a heavily degraded DHX heat transfer performance was sufficient to halt the rising salt temperature due to decay heat. Further investigation should be done to characterize the effects of TCHX performance degradation at longer time scales. High levels of TCHX degradation were shown to lead to a reactor salt temperature minimum after a few hours of operation followed by a steady increase in temperature. With reduced ability to exhaust heat to the environment, it is possible the DRACS would be unable to maintain cooling during a long loss of active cooling event.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Sensitivity Analysis of Passive Heat Removal Capability of FHR Based on Efficient Surrogate Model and GenFlow

Code Scaling, Applicability and Uncertainty Evaluation Methodology (CSAU) is used for quantifying reactor safety margins and works as an alternative method for licensing nuclear power plant. In the framework of CSAU, sensitivity and uncertainty analysis (SA and UA) should be performed. However, for large-scale complicated thermal hydraulics analysis simulated by code (e.g. RELAP5, CFD and subchannel analysis, the sensitivity and uncertainty analysis is really time-consuming. Furthermore, sometimes it is not feasible to perform SA and UA. Specifically, the computation time for Monte Carlo sampling or advanced LHS sampling can be neglected, but the computation time for thermal hydraulics code makes up main part of time during SA and UA process. In order to accelerate the speed of SA and UA, thermal hydraulics code can be improved based on advanced mathematic algorithm or using parallel method. However, the development for new mathematic method needs long time and strict verification and validation process is needed for a new code, which usually takes a couple of years or even longer time to have an approved code that can be used in nuclear industry. An alternative way to improve the speed of SA and UA is using surrogate model. The surrogate model is derived from the input as well as output data of the original code, assuming the code as a black box. The most common method is using response surface method (RSM) as a surrogate for the code, the input parameters are then sampled from their assumed distribution and the corresponding value of the response surface function is calculated. However, a couple of input parameters need hundreds or even thousands of original code calculations. The large number of runs is an obvious disadvantage of this method. Besides, the second disadvantage is an appropriate response surface function must be selected (e.g. quadratic, cubic, quartic, with or without cross product terms, or using a non-polynomial form) to avoid the overfit and underfit problem. This process is time consuming and expensive. Polynomial chaos expansion method is a reasonably fast and attractive alternative, stochastic model. The chaos expansion provides an efficient high-order method of including non-linear effects in stochastic analysis. Usually, the information about the model parameters and their probability distribution is limited and the dependence between them is not known. However, if arbitrary polynomial chaos is used, instead of assuming probability distribution for input parameters which may introduces additional subjectivity into the analysis, the available information can directly and most purely be used in stochastic analysis based on arbitrary data distribution. Thus, it is not necessary to know the exact probability density functions to perform SA and UA based on arbitrary polynomial chaos (aPC). The aPC has been applied for uncertainty quantification in many fields (e.g. in solid mechanics, fluid flows, thermal sciences), and become widely used in nuclear industry recently. Mk1 PB-FHR is a small modular fluoride-salt-cooled, high-temperature reactors (FHRs) that is a concept design by University of California, Berkeley (UCB). It has inherently safe features like natural-circulation-driven systems (e.g. direct reactor auxiliary cooling system (DRACS)) to passively remove decay heat from the reactor core during design basis and beyond design. It is necessary to perform SA and UA, since the licensing process of this new kind of reactor is under way and there are many design parameters that have not been fixed. Current nuclear commercial codes, such as RELAP5, have mainly been developed for light water reactors, which require the use of comprehensive two-phase flow models. This capability is not required to simulate single-phase flow phenomena in FHRs, whose baseline coolant, flibe, remains liquid up to 1430 deg. C at atmospheric pressure. The FHR advanced natural circulation analysis (FANCY) code has been developed specifically for FHR technology modeling and validation work has been performed by using CIET data in UCB. The code has been renamed General Flow (GenFlow) because it has been further developed to have the capability to model complicated pipework system based on object-oriented concept for user friendly purpose. Besides, it can be used to simulate both the force circulation as well as natural circulation. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Modular thermal and radiation shielding with passive heat removal

A housing assembly configured to house a reactor is disclosed. The housing assembly includes a plurality of modular walls configured to surround the reactor and a passive temperature control system. The plurality of modular walls includes a first modular wall. The passive temperature control system is coupled to the first modular wall. The passive temperature control system is configured to transfer heat between the reactor and an area around the housing assembly.

Trupiano, Anthony G.↗

Renal vascular control during normothermia and passive heat stress does not differ between healthy younger men and women

The mechanisms underlying greater heat-induced acute kidney injury risk in men versus women remain unknown. This study examined renal vascular control, including both vasodilatory (oral protein load) and vasoconstrictor (cold presser test) responses, during normothermia and heat stress and compared these responses between men and women. The results indicated that in both conditions neither renal vasodilatory nor vasoconstrictor responses differ between younger men and younger women.

Physiology↗

Analytic Expressions for the Inner-rim Structure of Passively Heated Protoplanetary Disks

We analytically derive the expressions for the structure of the inner region of protoplanetary disks based on the results from the recent hydrodynamical simulations. The inner part of a disk can be divided into four regions: a dust-free region with a gas temperature in the optically thin limit, an optically thin dust halo, an optically thick condensation front, and the classical, optically thick region, in order from the innermost to the outermost. We derive the dust-to-gas mass ratio profile in the dust halo using the fact that partial dust condensation regulates the temperature relative to the dust evaporation temperature. Beyond the dust halo, there is an optically thick condensation front where all the available silicate gas condenses out. The curvature of the condensation surface is determined by the condition that the surface temperature must be nearly equal to the characteristic temperature ∼1200 K. We derive the midplane temperature in the outer two regions using the two-layer approximation, with the additional heating by the condensation front for the outermost region. As a result, the overall temperature profile is step-like, with steep gradients at the borders between the outer three regions. The borders might act as planet traps where the inward migration of planets due to gravitational interaction with the gas disk stops. The temperature at the border between the two outermost regions coincides with the temperature needed to activate magnetorotational instability, suggesting that the inner edge of the dead zone must lie at this border. The radius of the dead zone inner edge predicted from our solution is ∼2–3 times larger than that expected from the classical optically thick temperature.

79 ASTRONOMY AND ASTROPHYSICS↗

Nuclear reactor cavity floor passive heat removal system

A nuclear reactor includes a reactor core disposed in a reactor pressure vessel. A radiological containment contains the nuclear reactor and includes a concrete floor located underneath the nuclear reactor. An ex vessel corium retention system includes flow channels embedded in the concrete floor located underneath the nuclear reactor, an inlet in fluid communication with first ends of the flow channels, and an outlet in fluid communication with second ends of the flow channels. In some embodiments the inlet is in fluid communication with the interior of the radiological containment at a first elevation and the outlet is in fluid communication with the interior of the radiological containment at a second elevation higher than the first elevation. The radiological containment may include a reactor cavity containing a lower portion of the pressure vessel, wherein the concrete floor located underneath the nuclear reactor is the reactor cavity floor.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Heat pipe augmented passive solar heating system

A heat pipe augmented passive solar space heating system modulates the temperature inside a building structure, particular during heating seasons when the ambient temperature is below levels customarily associated with adequate room comfort, and in some embodiments comprises a solar absorber, a heat pipe surrounding wholly or partially by insulation, the heat pipe having three main sections which are an evaporator at one end proximal to the solar absorber, a condenser at the other end proximal to an interior room being heated, and a rubber adiabatic section between those. Additional aspects such as a mechanical valve in the adiabatic section are disclosed to limit unwanted thermal gains when cooling is needed because the ambient temperatures already exceed room comfort.

14 SOLAR ENERGY↗

An Overview of Non-LWR Vessel Cooling Systems for Passive Decay Heat Removal (Technical Letter Final Report)

The following report provides a technical review of various reactor vessel cooling system (VCS) concepts under consideration for decay heat removal (DHR) in non-light water advanced reactor designs. This review focuses on ex-vessel designs, including the Reactor Cavity Cooling System (RCCS), the Reactor Vessel Auxiliary Cooling System (RVACS), and hybrid iterations, using both air and water cooling to achieve their heat removal function. Based on a literature review of publicly available sources published between 1979 and 2021, a technical summary is presented detailing existing and planned VCS design options, their applicability to specific reactor type, and review of authored research and development studies. Following an assessment of the availability of data and modeling tools, an evaluation was performed analyzing their likely performance during normal, degraded, and accident conditions, including reliability, stability, and longevity. With renewed consideration of air-based DHR systems by some US vendors, there is a need to fully understand the complexities inherent to natural circulation systems, and more importantly, how they may influence safety-related heat removal functions and system performance. For DHR systems that rely on air-based mode of cooling, this entails quantification of the impacts of low flow conditions during start-up, relative elevations of inlet and outlet ducts for below-grade installations, effects of the use of multiple parallel chimneys for redundancy, and impact of weather conditions at the plant site. For systems relying on water-based mode cooling, reliance on limited coolant inventory in an event of pipe break or extended duration accident scenarios, sensitivities related to stability of boiling flow and heat transfer conditions, and quantification of full-scale structural vibrations on balance of plant structures are among the complicating factors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High Performance Heat Pipe Power Transient Testing at SPHERE Facility

Microreactors are being researched, designed, and built at Idaho National Laboratory (INL). Microreactors are small reactors defined at less than 20MW of power. These reactor concepts are also being looked at throughout industry for various applications. An important aspect of these reactor designs is economic feasibility i.e. lower overnight capital cost. The driving factors for implementing microreactors are quick setup and takedown, minimal operators, and the ability to manufacture them readily and to fit in mid-sized containers for transport. A specific area of research to aid in successful integration of these factors within the designs is passive heat removal of the core’s thermal power. Interest in heat pipes to achieve this passive heat removal has been shown across multiple industry partners. Because of this interest, INL has developed a test facility to facilitate experimental tests for sodium filled heat pipes. INL has developed the Single Primary Heat Extraction and Removal Emulator (SPHERE) facility to run experiments on high performance, sodium filled heat pipes. As mentioned above, heat pipes are passive heat transfer devices. Radially, heat pipes are broken up into an outer wall, a small annular gap, a wick structure, and a centerline gap. They function by utilizing latent heat transfer. Heat pipes are traditionally separated into three regions, an evaporator (heat input), an adiabatic region, and finally a condenser region (heat removal). As heat is being applied to the evaporator, the working fluid undergoes a phase change to a vapor. This phase change causes a differential pressure across the axial length of the pipe driving flow down the center gap of the heat pipe. The vapor flows down past the adiabatic region to the condenser where the heat is removed. This heat removal forces the working fluid to phase change back to a liquid. The wick structure is then utilized to drive the flow back towards the evaporator by capillary forces. This backflow is aided by the annular gap. Because this heat transfer mechanism functions with latent heat transfer, the heat pipe is close to isothermal down the axial length. Heat pipes can operate under a wide range of working fluids. Considerations for these working fluids are primarily driven by operating temperatures amongst other important factors based around overall performance. Sodium filled heat pipes operate from 450°C up to 900°C. This temperature range works well for the current microreactor designs. In conjunction with this experimental capability, INL has developed a modeling software to simulate heat pipe physics within reactor cores. This modeling software is called Sockeye and functions under the established INL Multiphysics Object Oriented Simulation Environment (MOOSE). SPHERE also supports Sockeye development by providing the modeling team with experimental data on an array of setups and operating parameters to support validation efforts. A power transient experiment was performed utilizing the SPHERE facility to continue to aid with Sockeye development. The testing followed a proposed test plan to ramp up and down the temperature of the heat pipe. Sockeye models steady state heat pipe operation with high accuracy, the data provided by the power transient testing aims to assist with the validation efforts and further enhance transient modeling capability of the tool [2].

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Passive decay heat removal system design for the integral inherent safety light water reactor (I 2 S-LWR)

The Integral, Inherently Safe Light Water Reactor (I 2 S-LWR) is an innovative Pressurized Water Reactor (PWR) concept being developed by a multi-institutional team led by Georgia Tech and in collaboration with Westinghouse, under the Department of Energy’s Nuclear Energy University Programs Integrated Research Projects (DOE NEUP IRP). The University of Michigan leads the design of the thermalhydraulic and passive safety systems, in collaboration with Westinghouse and Bringham Young University. The I 2 S-LWR features an integral primary system configuration and is more conducive to the implementation of inherent safety features by eliminating potential accidents. In this paper, a novel passive Decay Heat Removal System (DHRS), is presented, consisting of a primary loop, an intermediate loop and a cooling tower loop. This passive system is designed to remove the I 2 S-LWR decay heat in the case of emergency heat removal transients, without the need for external power or operator action. The proposed DHR uses atmosphere as ultimate heat sink, to achieve indefinite decay heat removal. In this paper, firstly, the design of primary and secondary DHRS heat exchangers is optimized. Then the DHR heat removal characteristics are studied using the best-estimate thermal hydraulic code RELAP5. In addition, CFD simulations have been performed in order to investigate the DRHS helical coil primary heat exchanger performance with different coil pipe arrangements, and optimize its design. The performance of the proposed DHRS concept is investigated in case of a Station Black-Out (SBO) scenario. Operation of two, three and four DHRS trains is studied respectively. The findings show that three out of four DHRS trains are sufficient to indefinitely remove the core decay heat successfully during a SBO, and keep the reactor in a safe state without the need of any other auxiliary active system.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Performance Analysis of the Passive Residual Heat Removal System of an Integral Reactor

A demand for small modular reactors (SMRs) is gradually emerging worldwide, especially in Middle East Asia and Africa. SMART (System-integrated Modular Advanced ReacTor) developed by KAERI (Korea Atomic Energy Research Institute) is the first mover among several SMRs. It is designed to produce 100 MW of electricity, or 90 MW of electricity and 40,000 tons of desalinated water concurrently, which is sufficient for 100,000 residents. SMART is currently holding the initiative as the first licensed integral reactor in the world since 4 July 2012, when the standard design approval (SDA) was officially issued by the Nuclear safety and security commission (NSSC). After that, the SMART safety enhancement project was successfully conducted with intense support of the Government, resulting in an in-depth development of the most advanced safety features including the passive residual heat removal system (PRHRS). Recently, an agreement between KAERI and King Abdullah city for atomic and renewable energy (K.A. CARE) was officially signed for the pre-project engineering (PPE) in pursuit of the construction of SMART and developing human resources capability. Both parties are currently conducting a three-year preliminary study to review the feasibility of building SMART and to prepare for its commercialization. KAERI also takes responsibility to train R and D personnel chosen from Kingdom of Saudi Arabia. Sooner or later, SMART will open the global market of SMR and be the best competitive pioneer. Since the Fukushima accident, the passive cooling system of a nuclear reactor has received a great amount of attention. SMART is designed with passive systems in order to ensure the safety of the reactor. The PRHRS is one of the passive safety systems, which is activated after an accident to remove the residual heat from the core and the sensible heat of the reactor coolant system (RCS) through the steam generators (SGs) until the condition of the RCS reaches a safe shutdown condition. In the present study, the thermal performance of the PRHRS is predicted by using in-house code. Temperature of the RCS and the cooling rate of the RCS are traced with time to see if it is satisfactorily designed to meet the design requirements of the PRHRS. The dependency of the mass flow rate of the natural circulation on the filling ratio (FR) is also discussed. The FR is arbitrarily chosen from 0.22 to 0.50 and further parametric study is needed in the future.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Passive and compact liquid metal heat switch

A passive heat switch device is disclosed that includes a casing defining a closed channel, as well as a passive thermal actuator and liquid slug positioned inside the closed channel. The closed channel includes a heat conducting region made of a heat conducting material and an insulating region made of an insulating material. The passive thermal actuator is thermally coupled to the heat conducting material of the heat conducting region and extends into the insulating region of the closed channel. The passive thermal actuator deforms when an actuator temperature falls within a switching temperature range. The liquid slug is positioned within the closed channel and contacts at least a portion of the passive thermal actuator and the closed channel and is configured to move along the closed channel between the insulating region and the thermally conductive region in response to deformation of the passive thermal actuator.

42 ENGINEERING↗