Search NASA⌕ Search

SEARCH · Search NASA

Results for “passive inlet devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Technology Solutions Case Study: Evaluation of Ventilation Strategies in New Construction Multifamily Buildings, New York, New York

In multifamily buildings, particularly in the Northeast, exhaust ventilation strategies are the norm as a means of meeting both local exhaust and whole-unit mechanical ventilation rates. The issue of where the "fresh" air is coming from is gaining significance as air-tightness standards for enclosures become more stringent, and the "normal leakage paths through the building envelope" disappear. Consortium for Advanced Residential Buildings researchers have found that the majority of high performance, new construction, multifamily housing in the Northeast use one of four general strategies for ventilation: continuous exhaust only with no designated supply or make-up air source, continuous exhaust with ducted make-up air to apartments, continuous exhaust with supply through a make-up air device integral to the unit HVAC, and continuous exhaust with supply through a passive inlet device, such as a trickle vent. This research effort included several weeks of building pressure monitoring to validate system performance of the different strategies for providing make-up air to apartments.

apartments↗

Technology Solutions Case Study: Selecting Ventilation Systems for Existing Homes

In multifamily buildings, particularly in the Northeast, exhaust ventilation strategies are the norm as a means of meeting both local exhaust and whole-unit mechanical ventilation rates. The issue of where the "fresh" air is coming from is gaining significance as air-tightness standards for enclosures become more stringent, and the normal leakage paths through the building envelope disappear. Researchers from the Consortium for Advanced Residential Buildings (CARB) found that the majority of high performance, new construction, multifamily housing in the Northeast use one of four general strategies for ventilation: continuous exhaust only with no designated supply or make-up air source, continuous exhaust with ducted make-up air to apartments, continuous exhaust with supply through a make-up air device integral to the unit HVAC, and continuous exhaust with supply through a passive inlet device, such as a trickle vent. Insufficient information is available to designers on how these various systems are best applied. In this project, the CARB team evaluated the four different strategies for providing make-up air to multifamily residential buildings and developed guidelines to help contractors and building owners choose the best ventilation systems.

apartments↗

Evaluation of Ventilation Strategies in New Construction Multifamily Buildings

In multifamily buildings, particularly in the Northeast, exhaust ventilation strategies are the norm as a means of meeting both local exhaust and whole-unit mechanical ventilation rates. The issue of where the "fresh" air is coming from is gaining significance as air-tightness standards for enclosures become more stringent. CARB researchers have found that most new high performance, multifamily housing in the Northeast use one of four strategies for ventilation: continuous exhaust only with no designated supply or make-up air source, continuous exhaust with ducted make-up air to apartments, continuous exhaust with supply through a make-up air device integral to the unit HVAC, and continuous exhaust with supply through a passive inlet device, such as a trickle vent. Insufficient information is available to designers on how these various systems are best applied. Product performance data are based on laboratory tests, but there is no guarantee that those conditions will exist consistently in the finished building. In this research project, CARB evaluated the four ventilation strategies in the field to validate system performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Evaluation of Ventilation Strategies in New Construction Multifamily Buildings, New York, New York (Fact Sheet)

In multifamily buildings, particularly in the Northeast, exhaust ventilation strategies are the norm as a means of meeting both local exhaust and whole-unit mechanical ventilation rates. The issue of where the 'fresh' air is coming from is gaining significance as air-tightness standards for enclosures become more stringent, and the 'normal leakage paths through the building envelope' disappear. CARB researchers have found that the majority of high performance, new construction, multifamily housing in the Northeast use one of four general strategies for ventilation: continuous exhaust only with no designated supply or make-up air source, continuous exhaust with ducted make-up air to apartments, continuous exhaust with supply through a make-up air device integral to the unit HVAC, and continuous exhaust with supply through a passive inlet device, such as a trickle vent. Insufficient information is available to designers on how these various systems are best applied. Product performance data are based on laboratory tests, and the assumption is that products will perform similarly in the field. Proper application involves matching expected performance at expected building pressures, but there is no guarantee that those conditions will exist consistently in the finished building. This research effort, which included several weeks of building pressure monitoring, sought to provide field validation of system performance. The performance of four substantially different strategies for providing make-up air to apartments was evaluated.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Ventilation Strategies in New Construction Multifamily Buildings

In multifamily buildings, particularly in the Northeast, exhaust ventilation strategies are the norm as a means of meeting both local exhaust and whole-unit mechanical ventilation rates. The issue of where the 'fresh' air is coming from is gaining significance as air-tightness standards for enclosures become more stringent, and the 'normal leakage paths through the building envelope' disappear. CARB researchers have found that the majority of high performance, new construction, multifamily housing in the Northeast use one of four general strategies for ventilation: continuous exhaust only with no designated supply or make-up air source, continuous exhaust with ducted make-up air to apartments, continuous exhaust with supply through a make-up air device integral to the unit HVAC, and continuous exhaust with supply through a passive inlet device, such as a trickle vent. Insufficient information is available to designers on how these various systems are best applied. Product performance data are based on laboratory tests, and the assumption is that products will perform similarly in the field. Proper application involves matching expected performance at expected building pressures, but there is no guarantee that those conditions will exist consistently in the finished building. This research effort, which included several weeks of building pressure monitoring, sought to provide field validation of system performance. The performance of four substantially different strategies for providing make-up air to apartments was evaluated.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Passive suppression of pogo on the space shuttle

A qualitative assessment of the tendency for pogo instability of the shuttle vehicle in the absence of suppression devices, and the effectiveness of two passive suppressors (the compliant accumulator and the resistive accumulator) in counteracting any tendency toward instability is provided. In addition, the relative effectiveness of three suppressor locations (the low pressure pump (LWOP) inlet and discharge and the high pressure pump (HPOP) inlet) is also evaluated. The primary conclusion of the study is that effective pogo suppression, with passive devices, can be accomplished at the HPOP inlet location but not at the LPOP locations. Other conclusions are drawn regarding the relative effectiveness of the two accumulator types and with respect to tentative accumulator design requirements. Finally, a number of recommendations are made regarding future studies.

Lock, M. H.↗

Numerical Modeling of Flow Control in a Boundary-Layer-Ingesting Offset Inlet Diffuser at Transonic Mach Numbers

This paper will investigate the validation of the NASA developed, Reynolds-averaged Navier-Stokes (RANS) flow solver, OVERFLOW, for a boundary-layer-ingesting (BLI) offset (S-shaped) inlet in transonic flow with passive and active flow control devices as well as a baseline case. Numerical simulations are compared to wind tunnel results of a BLI inlet experiment conducted at the NASA Langley 0.3-Meter Transonic Cryogenic Tunnel. Comparisons of inlet flow distortion, pressure recovery, and inlet wall pressures are performed. The numerical simulations are compared to the BLI inlet data at a free-stream Mach number of 0.85 and a Reynolds number of approximately 2 million based on the fanface diameter. The numerical simulations with and without tunnel walls are performed, quantifying tunnel wall effects on the BLI inlet flow. A comparison is made between the numerical simulations and the BLI inlet experiment for the baseline and VG vane cases at various inlet mass flow rates. A comparison is also made to a BLI inlet jet configuration for varying actuator mass flow rates at a fixed inlet mass flow rate. Overall, the numerical simulations were able to predict the baseline circumferential flow distortion, DPCP avg, very well within the designed operating range of the BLI inlet. A comparison of the average total pressure recovery showed that the simulations were able to predict the trends but had a negative 0.01 offset when compared to the experimental levels. Numerical simulations of the baseline inlet flow also showed good agreement with the experimental inlet centerline surface pressures. The vane case showed that the CFD predicted the correct trends in the circumferential distortion levels for varying inlet mass flow but had a distortion level that was nearly twice as large as the experiment. Comparison to circumferential distortion measurements for a 15 deg clocked 40 probe rake indicated that the circumferential distortion levels are very sensitive to the symmetry of the flow and that a misalignment of the vanes in the experiment could have resulted in this difference. The numerical simulations of the BLI inlet with jets showed good agreement with the circumferential inlet distortion levels for a range of jet actuator mass flow ratios at a fixed inlet mass flow rate. The CFD simulations for the jet case also predicted an average total pressure recovery offset that was 0.01 lower than the experiment as was seen in the baseline. Comparisons of the flow features for the jet cases revealed that the CFD predicted a much larger vortex at the engine fan-face when compare to the experiment.

Allan, Brian G.↗

Numerical Modeling of Flow Control in a Boundary-Layer-Ingesting Offset Inlet Diffuser at Transonic Mach Numbers

This paper will investigate the validation of a NASA developed, Reynolds-averaged Navier-Stokes (RANS) flow solver, OVERFLOW, for a boundary-layer-ingesting (BLI) offset (S-shaped) inlet in transonic flow with passive and active flow control devices as well as the baseline case. Numerical simulations are compared to wind tunnel results of a BLI inlet conducted at the NASA Langley 0.3-Meter Transonic Cryogenic Tunnel. Comparisons of inlet flow distortion, pressure recovery, and inlet wall pressures are performed. The numerical simulations are compared to the BLI inlet data at a freestream Mach number of 0.85 and a Reynolds number of approximately 2 million based on the length of the fan-face diameter. The numerical simulations with and without wind tunnel walls are performed, quantifying effects of the tunnel walls on the BLI inlet flow measurements. The wind tunnel test evaluated several different combinations of jet locations and mass flow rates as well as a vortex generator (VG) vane case. The numerical simulations will be performed on a single jet configuration for varying actuator mass flow rates at a fix inlet mass flow condition. Validation of the numerical simulations for the VG vane case will also be performed for varying inlet mass flow rates. Overall, the numerical simulations were able to predict the baseline circumferential flow distortion, DPCPavg, very well for comparisons made within the designed operating range of the BLI inlet. However the CFD simulations did predict a total pressure recovery that was 0.01 lower than the experiment. Numerical simulations of the baseline inlet flow also showed good agreement with the experimental inlet centerline surface pressures. The vane case showed that the CFD predicted the correct trends in the circumferential distortion for varying inlet mass flow but had a distortion level that was nearly twice as large as the experiment. Comparison to circumferential distortion measurements for a 15 deg clocked 40 probe rake indicated that the circumferential distortion levels are very sensitive to the symmetry of the flow and that a miss alignment of the vanes in the experiment could have resulted in this difference. The numerical simulations of the BLI inlet with jets showed good agreement with the circumferential inlet distortion levels for a range of jet actuator mass flow ratios at a fixed inlet mass flow rate. The CFD simulations for the jet case also predicted an average total pressure recovery that was 0.01 lower than the experiment as was seen in the baseline. Comparison of the flow features the jet case revealed that the CFD predicted a much larger vortex at the engine fan-face when compare to the experiment.

Allan Brian G.↗

Boundary-layer-ingesting inlet flow control system

A system for reducing distortion at the aerodynamic interface plane of a boundary-layer-ingesting inlet using a combination of active and passive flow control devices is disclosed. Active flow control jets and vortex generating vanes are used in combination to reduce distortion across a range of inlet operating conditions. Together, the vortex generating vanes can reduce most of the inlet distortion and the active flow control jets can be used at a significantly reduced control jet mass flow rate to make sure the inlet distortion stays low as the inlet mass flow rate varies. Overall inlet distortion, measured and described as average SAE circumferential distortion descriptor, was maintained at a value of 0.02 or less. Advantageous arrangements and orientations of the active flow control jets and the vortex generating vanes were developed using computational fluid dynamics simulations and wind tunnel experimentations.

Owens, Lewis R.↗

On the Interaction of a Premixed Flame with an Acoustic Disturbance

The main objective of this research is to analyze the effect of acoustic disturbances on a premixed flame and determine their role in the onset of combustion instabilities. Computations for the one-dimensional, unsteady combustion of a lean premixed methane-air mixture are performed. An acoustic excitation is introduced in the chamber and interacts with the flame front. Our results indicate that as the amplitude of the acoustic excitation is increased, the flame front position fluctuates rapidly. This phenomenon is even more intense when the frequency of the acoustic disturbance matches the fundamental frequency of the chamber. Our results suggest that the interactions between the flame and the acoustic excitation may result in flame extinguishment. In addition various passive control devices are tested and we found that the Helmholtz resonator with rounded inlet corners is the most efficient.

Hood, Caroline↗

Active Flow Control For Inlets

This presentation describes the progress to date of the Small-Scale Demonstration for the Active Flow Control element of the Propulsion Airframe Integration Project. The goal of this work package is to demonstrate at small scale the ability to improve pressure recovery and distortion in an S-inlet with boundary layer ingestion representative of a Blended Wing Body (BWB) configuration. The effectiveness of several active and passive devices to control flow in an adverse pressure gradient with secondary flows present was evaluated in the Langley 15-Inch Low-Turbulence Tunnel. In this study, passive microvanes, microbumps, and piezoelectric synthetic jets were evaluated for their flow control characteristics using surface static pressures, flow visualization, and 3D Stereo Digital Particle Image Velocimetry. The microvanes imparted a higher level of vorticity to the flow than any of the other devices tested. Alternative actuator concepts are being pursued to support the Small-Scale Demonstration Level 1 milestone in FY03.

Gorton, Susan A.↗

Inlet Flow Control and Prediction Technologies for Embedded Propulsion Systems

Fail-safe inlet flow control may enable high-speed cruise efficiency, low noise signature, and reduced fuel-burn goals for hybrid wing-body aircraft. The objectives of this program are to develop flow control and prediction methodologies for boundary-layer ingesting (BLI) inlets used in these aircraft. This report covers the second of a three year program. The approach integrates experiments and numerical simulations. Both passive and active flow-control devices were tested in a small-scale wind tunnel. Hybrid actuation approaches, combining a passive microvane and active synthetic jet, were tested in various geometric arrangements. Detailed flow measurements were taken to provide insight into the flow physics. Results of the numerical simulations were correlated against experimental data. The sensitivity of results to grid resolution and turbulence models was examined. Aerodynamic benefits from microvanes and microramps were assessed when installed in an offset BLI inlet. Benefits were quantified in terms of recovery and distortion changes. Microvanes were more effective than microramps at improving recovery and distortion.

McMillan, Michelle L.↗

Active Suppression of Pogo on the Space Shuttle

The use of active pogo suppressors on the space shuttle was qualitatively investigated. Suppressor design concepts and the effectiveness of these designs in maintaining the stability of the shuttle vehicle were the primary concerns. Suppressor design concepts were developed by means of a series of parametric stability analyses. These two designs together with two designs provided by NASA were evaluated in detail for control effectiveness, performance relative to a passive suppression device, sensitivity of performance to feedback error, suppressor volume flow requirements, and suppressor development requirements. An active device at the high pressure oxidizer pump inlet was shown to provide a simple and effective design that is insensitive to error in the feedback signal. The sizing of an active suppressor was demonstrated to be dependent upon knowledge of the dynamic characteristics of the system.

Lock, M. H.↗

Cryogenic fluid management for low-g transfer

An account is given of design and operations criteria pertaining to low-g environment systems for the collection and delivery of liquid cryogens to a supply tank drain inlet in orbit. Analyses must assess the draining efficiencies of such devices, because the minimization of supply tank residual contents is of the essence. Settling accelerations, passive expulsion, and positive expulsion methods of fluid control have all been successfully demonstrated in orbit. Attention is given to the unique advantages and disadvantages of each method in view of different sets of requirements.

Frank, D. J.↗

Modular jet impingement assemblies with passive and active flow control for electronics cooling

Power electronics modules having modular jet impingement assembly utilized to cool heat generating devices are disclosed. The modular jet impingement assemblies include a modular manifold having a distribution recess, one or more angled inlet connection tubes positioned at an inlet end of the modular manifold that fluidly couple the inlet tube to the distribution recess and one or more outlet connection tubes positioned at an outlet end of the modular manifold that fluidly coupling the outlet tube to the distribution recess. The modular jet impingement assemblies include a manifold insert removably positioned within the distribution recess and include one or more inlet branch channels each including an impinging slot and one or more outlet branch channels each including a collecting slot. Further a heat transfer plate coupled to the modular manifold, the heat transfer plate comprising an impingement surface including an array of fins that extend toward the manifold insert.

42 ENGINEERING↗

Acoustic Monitoring of Beluga Whale Interactions with Cook Inlet Tidal Energy Project

Cook Inlet, Alaska is home to some of the greatest tidal energy resources in the U.S., as well as an endangered population of beluga whales (Delphinapterus leucas). Successfully permitting and operating a tidal power project in Cook Inlet requires a biological assessment of the potential and realized effects of the physical presence and sound footprint of tidal turbines on the distribution, relative abundance, and behavior of Cook Inlet beluga whales. ORPC Alaska, working with the Project Team—LGL Alaska Research Associates, University of Alaska Anchorage, TerraSond, and Greeneridge Science—undertook the following U.S. Department of Energy (DOE) study to characterize beluga whales in Cook Inlet – Acoustic Monitoring of Beluga Whale Interactions with the Cook Inlet Tidal Energy Project (Project). ORPC Alaska, LLC, is a wholly-owned subsidiary of Ocean Renewable Power Company, LLC, (collectively, ORPC). ORPC is a global leader in the development of hydrokinetic power systems and eco-conscious projects that harness the power of ocean and river currents to create clean, predictable renewable energy. ORPC is developing a tidal energy demonstration project in Cook Inlet at East Foreland where ORPC has a Federal Energy Regulatory Commission (FERC) preliminary permit (P-13821). The Project collected baseline data to characterize pre-deployment patterns of marine mammal distribution, relative abundance, and behavior in ORPC’s proposed deployment area at East Foreland. ORPC also completed work near Fire Island where ORPC held a FERC preliminary permit (P-12679) until March 6, 2013. Passive hydroacoustic devices (previously utilized with bowhead whales in the Beaufort Sea) were adapted for study of beluga whales to determine the relative abundance of beluga whale vocalizations within the proposed deployment areas. Hydroacoustic data collected during the Project were used to characterize the ambient acoustic environment of the project site pre-deployment to inform the FERC pilot project process. The Project compared results obtained from this method to results obtained from other passive hydrophone technologies and to visual observation techniques performed simultaneously. This Final Report makes recommendations on the best practice for future data collection, for ORPC’s work in Cook Inlet specifically, and for tidal power projects in general. This Project developed a marine mammal study design and compared technologies for hydroacoustic and visual data collection with potential for broad application to future tidal and hydrokinetic projects in other geographic areas. The data collected for this Project will support the environmental assessment of future Cook Inlet tidal energy projects, including ORPC’s East Foreland Tidal Energy Project and any tidal energy developments at Fire Island. The Project’s rigorous assessment of technology and methodologies will be invaluable to the hydrokinetic industry for developing projects in an environmentally sound and sustainable way for areas with high marine mammal activity or endangered populations. By combining several different sampling methods this Project will also contribute to the future preparation of a comprehensive biological assessment of ORPC’s projects in Cook Inlet.

16 TIDAL AND WAVE POWER↗

Radial Compressors with Advanced Secondary Flow Paths for Extended Operating Range

Adequate range is a critical criterion in determining the proper compressor for a given application. In industries centering on turbochargers, range is often the dominant concern. Many times, significant sacrifices in performance are made at the design point in order to obtain enough range of the machine for the duty required. Active controls, the most common being inlet guide vanes (IGVs), can provide sufficient range extension while generating minimal degradation of performance at the design point. Such devices, however, add significant cost and complexity to the machine as they require an active control mechanism. Other devices, such as recirculating casing treatment (RCT), have the advantage of both cost and simplicity by virtue of their passive nature. They’ve seen widespread adoption in the turbocharger industry, though they are generally less effective than IGVs in extending range. A novel approach to extend compressor range through a passive method is proposed here. The method takes some inspiration from classical RCT applications in that it prompts recirculation at low flow rates and corresponding higher back pressures. This recirculation then occupies a portion of the primary cross-sectional passage area and confines the rest of the non-recirculating flow to a smaller area. This restriction forces a higher meridional velocity and a more favorable incidence angle at the impeller blade leading edge. The recirculation is accomplished by laying out an expanded secondary flow path at the rear of the impeller leading back to the inlet hub region. Vanes on the rear of the impeller disk provide just enough pressure rise to counter the induced pressure from the primary flow at the design point. This yields very low mass flow in the secondary path, a condition known as “shutoff” in the pump industry. At lower primary flow levels, and higher back pressures, the secondary flow is induced back to the impeller inlet setting up the recirculation region and pinching the primary flow. Various vane configurations and layouts in the secondary region are explained, and advantages and disadvantages of each are covered. The range extensions made possible by this method and the corresponding impact on performance is discussed.

compressors, extended operating range↗

Quantifying conditional probabilities of fish-turbine encounters and impacts

Tidal turbines are one source of marine renewable energy but development of tidal power is hampered by uncertainties in fish-turbine interaction impacts. Current knowledge gaps exist in efforts to quantify risks, as empirical data and modeling studies have characterized components of fish approach and interaction with turbines, but a comprehensive model that quantifies conditional occurrence probabilities of fish approaching and then interacting with a turbine in sequential steps is lacking. We combined empirical acoustic density measurements of Pacific herring ( Clupea pallasii ) and when data limited, published probabilities in an impact probability model that includes approach, entrainment, interactions, and avoidance of fish with axial or cross-flow tidal turbines. Interaction impacts include fish collisions with stationary turbine components, blade strikes by rotating blades, and/or a collision followed by a blade strike. Impact probabilities for collision followed by a blade strike were lowest with estimates ranging from 0.0000242 to 0.0678, and highest for blade strike ranging from 0.000261 to 0.40. Maximum probabilities occurred for a cross-flow turbine at night with no active or passive avoidance. Estimates were lowest when probabilities were conditional on sequential events, and when active and passive avoidance was included for an axial-flow turbine during the day. As expected, conditional probabilities were typically lower than analogous independent events and literature values. Estimating impact probabilities for Pacific herring in Admiralty Inlet, Washington, United States for two device types illustrates utilization of existing data and simultaneously identifies data gaps needed to fully calculate empirical-based probabilities for any site-species combination.

collision risk↗