Search NASA⌕ Search

SEARCH · Search NASA

Results for “passive islanding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

A Data-Driven Passive Islanding Detection Scheme

This paper proposes a novel statistical parameters based data driven approach for passive islanding detection. The proposed scheme relies in the voltage data, measured at the point of common coupling, and is comprised of three stages. The Stage-1 quickly detects what is termed as coarse islanding, Stage-2 computes the decaying DC detector (DDCD), and 3) finally, the digital relay logic (DRL) is devised in Stage-3. The proposed scheme is tested as per the IEEE-1547, UL 1741 and IEC-62116 standards. Various tests are investigated on the modified IEEE-13 bus system, modeled in PSCAD/EMTDC, under stringent test scenarios such as power mismatch, induction motor starting effect, capacitor bank switching and various level of loads changes, considered for both single and multiple DG systems. The test results reveal that the proposed scheme can detect islanding in less than 2 cycles, and results in nearly zero non detection zone (NDZ). Also, the scheme can very well be used for single-phase microgrids too as it relies only on the single phase voltage information.

anti-islanding protection↗

A Data-Driven Passive Islanding Detection Scheme

This paper proposes a simple yet effective statistical parameters based passive islanding scheme. The proposed scheme relies only the voltage data, measured at the point of common coupling (PCC), and is comprised of three stages. The Stage-1 quickly computes what is termed as mean based coarse islanding detection (MID), Stage-2 computes the decaying DC detector (DDCD), and 3) finally, MID is used in conjunction with DDCD as per the statistical digital relay logic (SRDL) is devised in Stage-3 to distinguish between islanding events from non islanding events. Various tests are investigated on the Banshee's industrial Microgrid (MG), modelled in the Real Time Digital Simulator (RTDS), on the basis of the IEEE-1547, UL 1741 standards. The validation of the proposed islanding detection methodology (PIDM) in RTDS platform ensures the viability of the proposed scheme in practical systems. The test results reveal that the PIDM can detect islanding within 2 cycles, and results in a very small non detection zone (NDZ). Moreover, the scheme can very well be used for single-phase MG too as it relies only on the single phase voltage information.

anti-islanding protection↗

Passive Islanding Detection of Inverter-Based Resources in a Noisy Environment

Islanding occurs when a load is energized solely by local generators and can result in frequency and voltage instability, changes in current, and poor power quality. Poor power quality can interrupt industrial operations, damage sensitive electrical equipment, and induce outages upon the resynchronization of the island with the grid. This study proposes an islanding detection method employing a Duffing oscillator to analyze voltage fluctuations at the point of common coupling (PCC) under a high-noise environment. Unlike existing methods, which overlook the noise effect, this paper mitigates noise impact on islanding detection. Power system noise in PCC measurements arises from switching transients, harmonics, grounding issues, voltage sags and swells, electromagnetic interference, and power quality issues that affect islanding detection. Transient events like lightning-induced traveling waves to the PCC can also introduce noise levels exceeding the voltage amplitude by more than seven times, thus disturbing conventional detection techniques. The noise interferes with measurements and increases the nondetection zone (NDZ), causing failed or delayed islanding detection. The Duffing oscillator nonlinear dynamics enable detection capabilities at a high noise level. The proposed method is designed to detect the PCC voltage fluctuations based on the IEEE standard 1547 through the Duffing oscillator. For the voltages beyond the threshold, the Duffing oscillator phase trajectory changes from periodic to chaotic mode and sends an islanded operation command to the inverter. The proposed islanding detection method distinguishes switching transients and faults from an islanded operation. Experimental validation of the method is conducted using a 3.6 kW PV setup.

Energy & Fuels↗

Macroscopic trends of linear tearing stability in cylindrical current profiles

Abstract The likelihood of realising tokamak power-plants will be greatly improved by the discovery of high-gain equilibria that resist the formation of small islands and hence avoid the disruptive neoclassical tearing mode. We propose a series of studies to understand how simple tokamak design can leverage aspects of tearing onset physics to maximise passive resistance to island formation. Here we investigate the variation that current profiles can bring about in preventing tearing onset through the cylindrical linear tearing stability parameter Δ ′ . A database of 159148 realistic pilot-plant current profiles was generated with Monte Carlo sampling, and the distribution of Δ ′ values was linked with interpretable profile characteristics. In agreement with prior theoretical and experimental studies, Δ ′ was found to be strongly correlated with the existence and steepness of a local toroidal current well or hill, with the former destabilising and the latter stabilising. In the absence of these two cases, the remaining Δ ′ values were linearly bounded by the toroidal current gradient at the rational surface.

Physics↗

MODIS Aerosol and Low‐Cloud Retrievals: Orographic Effects in the Wake of Macquarie Island

Abstract Visible/infrared imagery from passive satellites is commonly relied upon to study low cloud microphysics over oceanic regions, including for the Southern Ocean (SO), but relatively little validation has been undertaken for the SO. In this article, we compare low‐cloud effective radius ( r e ), cloud droplet number concentration ( N d ) and cloud liquid water path (LWP) retrievals from the NASA Moderate Imaging Spectroradiometer (MODIS) with surface measurements collected during the Macquarie Island Cloud and Radiation Experiment (MICRE). MODIS 3.7‐μm band retrievals show little bias and moderately good correlation relative to MICRE retrievals for liquid‐phase low clouds when restricted to Solar Zenith Angles <65° on spatial scales of 50–100 km. However, the low overall bias in 3.7‐μm band effective radius ( r e 3.7 ) retrievals partly results from cancellation of errors: r e 3.7 is overestimated for non‐to‐lightly precipitating clouds, and underestimated for heavier drizzling clouds by ∼1–1.5 μm. 1.6‐μm and 2.1‐μm band r e retrievals are biased high. N d may likewise be slightly under‐ or overestimated depending on the concentration, but there is insufficient data to provide confidence in this result. Interestingly, a composite of MODIS retrievals from 2002 to 2020 show a distinct region of enhanced cloud cover and N d (and lower r e ) in the wake of Macquarie Island associated with orographic cloud formation. MODIS retrievals of aerosol optical depth (AOD) and Angstrom Exponent (AE) upwind and downwind of the island do not differ significantly. Comparison with MICRE measurements suggests that MODIS Collection 6 AOD retrievals are reasonable, while AE is problematically large.

54 ENVIRONMENTAL SCIENCES↗

Small Molecule Inhibitor-Modulated Al 2 O 3 Atomic Layer Deposition on Monolayer MoS 2 for Controlled Nucleation

The integration of ultrathin dielectrics on two-dimensional (2D) semiconductors is essential for advancing beyond-Si electronics. However, the intrinsic inertness of van der Waals 2D basal planes remains a primary bottleneck to achieving uniform dielectric nucleation and growth. Here, in this study, we introduce a small molecule inhibitor (SMI)-modulated thermal atomic layer deposition (ALD) strategy, exemplified by aluminum oxide (Al 2 O 3 ) ALD on monolayer molybdenum disulfide (1L MoS 2 ) with acetic acid (HAc) SMI. The ABC-type sequence comprises HAc inhibitor (A), trimethylaluminum (TMA) precursor (B), and deionized H 2 O coreactant (C). In situ quartz crystal microbalance (QCM) studies reveal robust HAc adsorption on Al 2 O 3 and suppression of subsequent oxide growth on HAc-passivated surfaces. When applied to 1L MoS 2 , this inhibitory pathway enables HAc to selectively passivate nascent Al 2 O 3 nuclei formed on the MoS 2 surface, limiting their three-dimensional (3D) island coarsening and redirecting precursor adsorption toward the uncovered basal plane. Consequently, nearly continuous ultrathin (∼1.5 nm) Al 2 O 3 films are achieved on 1L MoS 2 with markedly improved uniformity compared to standard Al 2 O 3 ALD using TMA and H 2 O, as validated by atomic force microscopy (AFM), cross-sectional scanning transmission electron microscopy (STEM), and energy-dispersive X-ray spectroscopy (EDS). Density functional theory (DFT) calculations further provide atomistic insight into HAc-modulated Al 2 O 3 nucleation, corroborating the energetic preference of HAc for Al 2 O 3 over MoS 2 and attenuated TMA adsorption on HAc-passivated surfaces. Spatially resolved Raman spectroscopy also confirms that the HAc-modulated process preserves the structural integrity of 1L MoS 2 , with only minimal strain and doping perturbations observed after dielectric deposition. This SMI-modulated approach offers a broadly applicable framework for controlling ALD nucleation across various inhibitors, ALD chemistries, and 2D materials, opening opportunities for reliable dielectric integration in next-generation nanoelectronics.

36 MATERIALS SCIENCE↗

On the minimum transport required to passively suppress runaway electrons in SPARC disruptions

In Izzo et al (2022 Nucl. Fusion 62 096029), state-of-the-art modeling of thermal and current quench (CQ) magnetohydrodynamics (MHD) coupled with a self-consistent evolution of runaway electron (RE) generation and transport showed that a non-axisymmetric (n = 1) in-vessel coil could passively prevent RE beam formation during disruptions in SPARC, a compact high-field tokamak projected to achieve a fusion gain Q > 2 in DT plasmas. However, such suppression requires finite transport of REs within magnetic islands and re-healed flux surfaces; conservatively assuming zero transport in these regions leads to an upper bound of RE current ~1MA compared to ~8.7MA of pre-disruption plasma current. Further investigation finds that core-localized electrons, within r/a < 0.4 and with kinetic energies ~0.2–15 MeV, contribute most to the RE plateau formation. Yet only a relatively small amount of transport, i.e. a diffusion coefficient ~18 m 2 s -1 , is needed in the core to fully mitigate these REs. Properly accounting for (a) the CQ electric field's effect on RE transport in islands and (b) the contribution of significant RE currents to disruption MHD may help achieve this.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demand for off-grid desalination technology in small-island communities — Can interfacial solar vapor generation be the answer?

The demand for an off-grid desalination technology and the feasibility of using interfacial solar vapor generation (ISVG) to address the problem were evaluated within the context of Bungin Island. Bungin Island is a small-island community in Indonesia facing water scarcity. By conducting interviews with households there, we found that households located on the exterior portion of the island faced the greatest challenges to water access. For example, only 17% of exterior households had piped water access, whereas 67% central households had piped water access. Similar inequities for exterior households were also found with respect to the cost of getting additional water. Thus, we determined that an off-grid desalination technology is best suited for solving the water access problems for the most vulnerable communities in small islands. Further, ISVG technologies that draw on the radiative energy in sunlight to achieve desalination are promising in increasing water access by offering a floating off-grid devices on water near exterior households, passive operation, low capital investment, and simple maintenance. These findings stress the importance of understanding how contextual factors shape barriers to water access and provide a road map on how to begin incorporating these factors into the development of a more sustainable desalination technology.

42 ENGINEERING↗

Macroscopic trends of neoclassical tearing stability in high-field H-mode tokamak pilot plants

The neoclassical tearing mode (NTM) stability metric—minimum marginally stable island width $w$$^{*}_{m}$—was compared across 14651 inductive high-field tokamak pilot plant equilibria. Larger devices with reduced elongation and/or increased minor radius demonstrated an order-of-magnitude increase in $w$$^{*}_{m}$, primarily due to a reduction in bootstrap drive. This work is part of an ongoing effort to ensure passive NTM-stability in the ARC tokamak, in which the technology to achieve active tearing-suppression with localised electron cyclotron current drive does not yet exist. The equilibrium scenarios in the database were Monte Carlo generated and normalised to the same >400MW fusion power, minimum pressure scenario at a range of plasma currents, before tearing analysis using the modified Rutherford equation was applied for all resonant poloidal and toroidal m, n modes up to n = 4. Single-helicity toroidal Δ' calculations in resistive DCON set the minimum marginally stable island width, and a simple modal scaling proportional to –m 2 n –1 was identified for high-m Δ' values. The dominant correlates of $w$$^{*}_{m}$ and Δ' across the database were analysed using interpretable machine learning techniques.

NTM seeding↗

Vulcan Test Platform: Demonstrating the Data Center as a Flexible Grid Asset

Explosive data center demand is outpacing grid infrastructure development. AI workloads and hyperscale cloud growth are creating unprecedented power requirements, while traditional grid expansion faces multi-year development timelines, regulatory hurdles, and decarbonization challenges. Sidewalk Infrastructure Partners recognized this impending crisis years ago and founded Verrus to develop an innovative solution: data centers that function as grid assets rather than passive loads. The Verrus approach integrates proprietary grid-aware controls with battery energy storage systems (BESS) in a medium-voltage architecture that delivers three critical capabilities: Fast-responding demand flexibility that can service requests from the utility within 10 seconds, Uninterrupted transition to islanded operation during grid disturbances, Continuous uptime assurance while maintaining all customer service level commitments Through Verrus' strategic partnership with the National Renewable Energy Laboratory (NREL), we validated these capabilities on Vulcan, a 70 MW utility-scale test platform powered by NREL's ARIES Virtual Emulation Environment. This deployment-ready technology has successfully demonstrated that Verrus data centers can deliver meaningful grid services while maintaining mission-critical reliability. This technical report outlines the design, methodology, and results of this emulated deployment, demonstrating that data centers can play a pivotal role in enhancing grid flexibility and reliability, without sacrificing service level guarantees.

24 POWER TRANSMISSION AND DISTRIBUTION↗

First fluctuation measurements using an Imaging Neutral Particle Analyzer on DIII-D

A recent upgrade to the Imaging Neutral Particle Analyzer (INPA) on DIII-D has allowed for the first fluctuation measurements using an INPA to be taken during a neoclassical tearing mode (NTM). The INPA signal tracked the mode over 150 ms as the mode frequency dropped to zero, capturing both the NTM with poloidal and toroidal mode numbers $m/n=2/1$ and a $3/2$ mode at double the frequency. Analysis shows that the signals originate from charge exchange events near the edge of the plasma, and relative fluctuation amplitudes are greater than 25% for the duration of the NTM. Filtered signals show frequency beating patterns that are phase-space dependent. Simulated signal is dominated by prompt transport from the neutral beams to the INPA sightline, while the contribution from the slowing down distribution is significantly lower. Simulated measurements in the range of pitches that the diagnostic is sensitive to (0.5≤|v∥/v|≤ 0.75) show the signal is dominated by trapped orbits that pass through magnetic islands near the edge of the plasma. Calculations of expected fluctuation levels show that only direct interaction with the NTM can provide the strong relative fluctuation levels seen experimentally. The prompt nature of the orbits and thin radial layer found to contribute to synthetic signals suggest INPA passive data may be used to measure the perturbations of confined orbits on a single pass through a plasma instability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Helper-embedded satellites from an integrase clade that repeatedly targets prophage late genes

Abstract Satellites such as phage-induced chromosomal islands (PICIs) are mobile genetic elements relying on helper phages for their mobilization, through trans-regulatory interactions. We discovered a PICI with a more intimate cis-regulatory configuration, integrated within a late gene of its helper prophage. This helper-embedded PICI (HE-PICI) configuration delays expression of the interrupted helper late gene until the satellite excises and provides passive helper-driven components to both HE-PICI replication and late transcription. Upon induction of a helper-satellite composite, precise excision of the entire composite was observed, followed by composite replication, then satellite excision. We mapped 491 additional HE-PICIs to one of 14 sites in cognates of phage lambda late genes. Associated integrases form a single phylogenetic clade with subclades respecting the 14 site groups, exhibiting repeated tropism for prophage late genes as new integration sites evolve. Four ordered zones in a general gram-negative PICI genome organization are: an integration zone encoding integrase and AlpA, a dynamic zone encoding members of the Bro-N network of domain-swapping DNA-interactive proteins and immunity repressor RNAs, a replication zone, and a dynamic late zone in which clusters as large as 17 consecutive helper prophage late genes have been captured. Helper-embedded satellites present new dimensions in satellite/helper relationships.

Tommasini, Dario↗

Demonstrating the data center as a flexible grid asset using a C-HIL setup

Increasing data center demand is outpacing grid infrastructure development. Artificial intelligence workloads and hyperscale cloud growth are creating unprecedented demand for power, while traditional grid expansion faces multiyear development timelines. Verrus is developing an innovative datacenter solution for this challenge, data centers that act as active grid-supportive assets rather than passive loads. Our approach integrates a novel grid-aware power flow management system with battery energy storage systems(BESS) into a microgrid-controlled, medium-voltage power distribution architecture that delivers critical capabilities, such as: * Fast response to grid disturbances such over/ under voltage or over/ under frequency * Demand flexibility that can service requests from the utility within 10 s * Uninterrupted transition to islanded operation during grid outages * Continuous uptime assurance for compute loads while maintaining all customer service level agreements. Through Verrus' strategic partnership with the National Renewable Energy Laboratory (NREL), these capabilities were validated using NREL's Advanced Research on Integrated Energy Systems (ARIES) virtual emulation environment to model a 70-MW grid-interactive data center. This paper outlines the design, methodology, and results of this emulated deployment, demonstrating that data centers can provide both critical load resilience and ancillary grid support without compromising uptime requirements. Specifically, we present a digital real time simulation of a 70 MW data center integrated with a physical microgrid controller, and demonstrate the data center response in the event of a grid voltage and frequency event, utility demand response request and utility outage.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Benchmark study of the DTU OWC chamber with both two-way and one-way absorption

This paper reports on a benchmark study based on small-scale (1:50) measurements of a single, oscillating water column chamber mounted sideways in a long flume. The geometry of the OWC chamber is extracted from a barge-like, attenuator-type floating concept “KNSwing” with 40 chambers targeted for deployment in the Danish part of the North Sea. In addition to traditional two-way energy extraction we also consider one-way energy extraction with passive venting and compare chamber response, pressures and total absorbed energy between the two methods. A blind study was established for the numerical modeling, with participants applying several implementations of weakly nonlinear potential flow theory and commercial Navier–Stokes solvers (CFD). Both compressible and incompressible models were used for the air phase. Potential flow calculations predict more energy absorption near the chamber resonance for one-way absorption than for two-way absorption, but the opposite is found from the experimental measurements. This outcome is mainly attributed to energy losses in the experimental passive valve system, but this conclusion must be confirmed by better experimental measurements. Modeling the one-way valve in CFD proved to be very challenging and only one team was able to provide results which were generally closer to the experiments. The study illustrates the challenges associated with both numerical and experimental analysis of OWC chambers. Air compressibility effects were not found to be important at this scale, even with the large volume of additional air used for the one-way case.

16 TIDAL AND WAVE POWER↗

Design, Build, and Initial Testing of a Portable Methane Measurement Platform

The quantification of methane concentrations in air is essential for the quantification of methane emissions, which in turn is necessary to determine absolute emissions and the efficacy of emission mitigation strategies. These are essential if countries are to meet climate goals. Large-scale deployment of methane analyzers across millions of emission sites is prohibitively expensive, and lower-cost instrumentation has been recently developed as an alternative. Currently, it is unclear how cheaper instrumentation will affect measurement resolution or accuracy. To test this, the Wireless Autonomous Transportable Methane Emission Reporting System (WATCH 4 ERS) has been developed, comprising four commercially available sensing technologies: metal oxide (MOx,), Non-dispersion Infrared (NDIR), integrated infrared (INIR), and tunable diode laser absorption spectrometer (TDLAS). WATCHERS is the accumulated knowledge of several long-term methane measurement projects at Colorado State University’s Methane Emission Technology Evaluation Center (METEC), and this study describes the integration of these sensors into a single unit and reports initial instrument response to calibration procedures and controlled release experiments. Specifically, this paper aims to describe the development of the WATCH 4 ERS unit, report initial sensor responses, and describe future research goals. Meanwhile, future work will use data gathered by multiple WATCH 4 ERS units to 1. better understand the cost–benefit balance of methane sensors, and 2. identify how decreasing instrumentation costs could increase deployment coverage and therefore inform large-scale methane monitoring strategies. Both calibration and response experiments indicate the INIR has little practical use for measuring methane concentrations less than 500 ppm. The MOx sensor is shown to have a logarithmic response to methane concentration change between background and 600 ppm but it is strongly suggested that passively sampling MOx sensors cannot respond fast enough to report concentrations that change in a sub-minute time frame. The NDIR sensor reported a linear change to methane concentration between background and 600 ppm, although there was a noticeable lag in reporting changing concentration, especially at higher values, and individual peaks could be observed throughout the experiment even when the plumes were released 5 s apart. The TDLAS sensor reported all changes in concentration but remains prohibitively expensive. Our findings suggest that each sensor technology could be optimized by either operational design or deployment location to quantify methane emissions. The WATCH4ERS units will be deployed in real-world environments to investigate the utility of each in the future.

47 OTHER INSTRUMENTATION↗

Meteorological Conditions and Atmospheric Components Concentration in Urban Sites in Knoxville, USA. 2024

This dataset, which contains five csv files, reports several meteorological conditions such as temperature, wind speed, solar radiation, and net radiation measured in Cumberland Estates Park (CEP) and Socially Equal Energy Efficient Development (SEEED) sites in Knoxville, Tennessee, USA. Also, hourly concentration of particulate matter (PM) with different aerodynamic diameter and inorganic gases such as ozone and nitrogen dioxide measured in the two are included in this dataset. The concentrations of PM and inorganic gases were monitored using the MODULAIR, a low-cost sensor equipped with a solar power module. The measurement of the concentration of biogenic and anthropogenic volatile organic compounds (VOCs) of the two sites was determined using a High-Resolution Proton Transfer Reaction Time of Flight Mass Spectrometer (PTR-ToF-MS). The VOCs were collected using miniature canister (400 mL) equipped with female RAVEqc valve to 1/4” male compression fitting and an integrated passive air sampling kit. This work is a part of a larger study which investigates the impact of soil moisture and plant evapotranspiration on ambient temperature and relative humidity in several city parks in Knoxville, Tennessee.

54 ENVIRONMENTAL SCIENCES↗

Where to cool off: a geospatial framework for placement of cooling centers

Indoor cooling is essential to reduce heat stress and increase passive survivability during heatwaves. Although air conditioning (AC) is recommended for maintaining indoor thermal comfort, low- and medium-income households in the U.S. often do not own an AC and/or limit AC usage to reduce energy consumption and associated costs, thereby risking their health and safety. With the frequency and intensity of heatwaves increasing, cooling centers are considered an appropriate alternative to indoor cooling and a possible mitigation strategy to prevent adverse health impacts of heat exposure. However, these centers are limited in numbers and not always accessible. This requires (i) developing a geospatial framework using physical and social factors for optimal siting of cooling centers to meet future needs and (ii) ranking of existing and potential cooling centers (schools, libraries, religious institutions) based on their accessibility among vulnerable populations and proximity to healthcare facilities. We developed and deployed a geospatial framework based on the Multi-criteria Decision Analysis approach in five U.S. cities (Los Angeles (LA), Phoenix, Austin, Atlanta, Miami) to evaluate the effectiveness of the framework in ranking cooling centers based on accessibility and population coverage. The results revealed that (i) access to cooling centers varies across cities and 32.2–50.7% of centers are within walking distance of the most vulnerable populations, (ii) vulnerable populations exposed to Urban Heat Island (UHI) effects are more likely to experience energy burden, and (iii) about 21.2–49.4% of population with high energy burden have access to these centers. Considering that more cooling centers are needed to assist energy burdened households alleviate heat exposure impacts, the framework developed herein could be adapted to incorporate other factors (e.g. health impacts, policies) to assess site suitability of existing shelters, identify potential sites for new cooling centers, and geo-target communities where energy efficient emerging technologies could be deployed to reduce heat stress.

58 GEOSCIENCES↗