Search NASA⌕ Search

SEARCH · Search NASA

Results for “passive islanding detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

A Data-Driven Passive Islanding Detection Scheme

This paper proposes a simple yet effective statistical parameters based passive islanding scheme. The proposed scheme relies only the voltage data, measured at the point of common coupling (PCC), and is comprised of three stages. The Stage-1 quickly computes what is termed as mean based coarse islanding detection (MID), Stage-2 computes the decaying DC detector (DDCD), and 3) finally, MID is used in conjunction with DDCD as per the statistical digital relay logic (SRDL) is devised in Stage-3 to distinguish between islanding events from non islanding events. Various tests are investigated on the Banshee's industrial Microgrid (MG), modelled in the Real Time Digital Simulator (RTDS), on the basis of the IEEE-1547, UL 1741 standards. The validation of the proposed islanding detection methodology (PIDM) in RTDS platform ensures the viability of the proposed scheme in practical systems. The test results reveal that the PIDM can detect islanding within 2 cycles, and results in a very small non detection zone (NDZ). Moreover, the scheme can very well be used for single-phase MG too as it relies only on the single phase voltage information.

anti-islanding protection↗

Passive Islanding Detection of Inverter-Based Resources in a Noisy Environment

Islanding occurs when a load is energized solely by local generators and can result in frequency and voltage instability, changes in current, and poor power quality. Poor power quality can interrupt industrial operations, damage sensitive electrical equipment, and induce outages upon the resynchronization of the island with the grid. This study proposes an islanding detection method employing a Duffing oscillator to analyze voltage fluctuations at the point of common coupling (PCC) under a high-noise environment. Unlike existing methods, which overlook the noise effect, this paper mitigates noise impact on islanding detection. Power system noise in PCC measurements arises from switching transients, harmonics, grounding issues, voltage sags and swells, electromagnetic interference, and power quality issues that affect islanding detection. Transient events like lightning-induced traveling waves to the PCC can also introduce noise levels exceeding the voltage amplitude by more than seven times, thus disturbing conventional detection techniques. The noise interferes with measurements and increases the nondetection zone (NDZ), causing failed or delayed islanding detection. The Duffing oscillator nonlinear dynamics enable detection capabilities at a high noise level. The proposed method is designed to detect the PCC voltage fluctuations based on the IEEE standard 1547 through the Duffing oscillator. For the voltages beyond the threshold, the Duffing oscillator phase trajectory changes from periodic to chaotic mode and sends an islanded operation command to the inverter. The proposed islanding detection method distinguishes switching transients and faults from an islanded operation. Experimental validation of the method is conducted using a 3.6 kW PV setup.

Energy & Fuels↗