Search NASA⌕ Search

SEARCH · Search NASA

Results for “peak differential analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Crystallization Kinetics of a Solid Oxide Fuel Cell Seal Glass by Differential Thermal Analysis

Crystallization kinetics of a barium calcium aluminosilicate glass (BCAS), a sealant material for planar solid oxide fuel cells, have been investigated by differential thermal analysis (DTA). From variation of DTA peak maximum temperature with heating rate, the activation energy for glass crystallization was calculated to be 259 kJ/mol. Development of crystalline phases on thermal treatments of the glass at various temperatures has been followed by powder x-ray diffraction. Microstructure and chemical composition of the crystalline phases were investigated by scanning electron microscopy and energy dispersive spectroscopic (EDS) analysis. BaSiO3 and hexacelsian (BaAl2Si2O8) were the primary crystalline phases whereas monoclinic celsian (BaAl2Si2O8) and (Ba(x), Ca(y))SiO4 were also detected as minor phases. Needle-shaped BaSiO3 crystals are formed first, followed by the formation of other phases at longer times of heat treatments. The glass does not fully crystallize even after long term heat treatments at 750 to 900 C.

Bansal, Narottam P.↗

Photogrammetry Measurements During a Tanking Test on the Space Shuttle External Tank, ET-137

On November 5, 2010, a significant foam liberation threat was observed as the Space Shuttle STS-133 launch effort was scrubbed because of a hydrogen leak at the ground umbilical carrier plate. Further investigation revealed the presence of multiple cracks at the tops of stringers in the intertank region of the Space Shuttle External Tank. As part of an instrumented tanking test conducted on December 17, 2010, a three dimensional digital image correlation photogrammetry system was used to measure radial deflections and overall deformations of a section of the intertank region. This paper will describe the experimental challenges that were overcome in order to implement the photogrammetry measurements for the tanking test in support of STS-133. The technique consisted of configuring and installing two pairs of custom stereo camera bars containing calibrated cameras on the 215-ft level of the fixed service structure of Launch Pad 39-A. The cameras were remotely operated from the Launch Control Center 3.5 miles away during the 8 hour duration test, which began before sunrise and lasted through sunset. The complete deformation time history was successfully computed from the acquired images and would prove to play a crucial role in the computer modeling validation efforts supporting the successful completion of the root cause analysis of the cracked stringer problem by the Space Shuttle Program. The resulting data generated included full field fringe plots, data extraction time history analysis, section line spatial analyses and differential stringer peak ]valley motion. Some of the sample results are included with discussion. The resulting data showed that new stringer crack formation did not occur for the panel examined, and that large amounts of displacement in the external tank occurred because of the loads derived from its filling. The measurements acquired were also used to validate computer modeling efforts completed by NASA Marshall Space Flight Center (MSFC).

Littell, Justin D.↗

Transient/structural analysis of a combustor under explosive loads

The 8-Foot High Temperature Tunnel (HTT) at NASA Langley Research Center is a combustion-driven blow-down wind tunnel. A major potential failure mode that was considered during the combustor redesign was the possibility of a deflagration and/or detonation in the combustor. If a main burner flame-out were to occur, then unburned fuel gases could accumulate and, if reignited, an explosion could occur. An analysis has been performed to determine the safe operating limits of the combustor under transient explosive loads. The failure criteria was defined and the failure mechanisms were determined for both peak pressures and differential pressure loadings. An overview of the gas dynamics analysis was given. A finite element model was constructed to evaluate 13 transient load cases. The sensitivity of the structure to the frequency content of the transient loading was assessed. In addition, two closed form dynamic analyses were conducted to verify the finite element analysis. It was determined that the differential pressure load or thrust load was the critical load mechanism and that the nozzle is the weak link in the combustor system.

Gregory, Peyton B.↗

Determining the nucleation rate curve for lithium disilicate glass by differential thermal analysis

The crystallization of lithium disilicate (Li2O+2SiO2) glass nucleated at various temperatures was studied by differential thermal analysis (DTA). A plot of the DTA crystallization peak height versus nucleation temperature closely resembles the classical nucleation rate curve for lithium disilicate glass whose maximum is at 453 C. The glass becomes saturated with internal nuclei when heated at 453 C for 10 h. The activation energy for crystallization and the heat of crystallization are independent of the concentration of nuclei and are 249 + or - 10 and 67 + or - 3 kJ/mol, respectively. The Avrami exponent, n, depends strongly on the concentration of nuclei in the glass.

Ray, Chandra S.↗

Real time analysis of voiced sounds

A power spectrum analysis of the harmonic content of a voiced sound signal is conducted in real time by phase-lock-loop tracking of the fundamental frequency, (f sub 0) of the signal and successive harmonics (h sub 1 through h sub n) of the fundamental frequency. The analysis also includes measuring the quadrature power and phase of each frequency tracked, differentiating the power measurements of the harmonics in adjacent pairs, and analyzing successive differentials to determine peak power points in the power spectrum for display or use in analysis of voiced sound, such as for voice recognition.

Hong, J. P.↗

Instability Wave–Streak Interactions in a High Mach Number Boundary Layer at Flight Conditions

The interaction of stationary streaks undergoing nonmodal growth with modally unstable instability waves in a hypersonic boundary-layer flow is studied using numerical computations. The geometry and flow conditions are selected to match a relevant trajectory location from the ascent phase of the HIFiRE-1 flight experiment; namely, a 7 degree half-angle, circular cone with 2.5 mm nose radius, freestream Mach number equal to 5.30, unit Reynolds number equal to 13.42 m -1 , and wall-to-adiabatic temperature ratio of approximately 0.35 over most of the vehicle. This paper investigates the nonlinear evolution of initially linear optimal disturbances that evolve into finite-amplitude streaks, followed by an analysis of the modal instability characteristics of the perturbed, streaky boundary-layer flow. The investigation is performed with stationary direct numerical simulations (DNS) and plane-marching parabolized stability equations (PSE), in conjunction with partial-differential-equation-based planar eigenvalue analysis. The overall effect of streaks is to reduce the peak amplification factors of instability waves, indicating a possible downstream shift in the onset of laminar-turbulent transition. The present study confirms previous findings that the mean flow distortion of the nonlinear streak perturbation reduces the amplification rates of the Mack-mode instability. More importantly, however, the present results demonstrate that the spanwise varying component of the streak can produce a larger effect on the Mack-mode amplification. The study with selected azimuthal wavenumbers for the stationary streaks reveals that a wavenumber of approximately 1.4 times larger than the optimal wavenumber is more effective in stabilizing the planar Mack-mode instabilities. In the absence of unstable first-mode waves for the present cold-wall condition, transition onset is expected to be delayed until the peak streak amplitude increases to nearly 35 percent of the freestream velocity, when intrinsic instabilities of the boundary-layer streaks begin to dominate the transition process. For streak amplitudes below that limit a significant net stabilization is achieved, yielding a potential transition delay that can exceed 100 percent of the length of the laminar region in the uncontrolled case.

Boundary layer stability↗

In-Situ Reaction Monitoring for Lunar Applications Utilizing a Single Quadrupole Residual Gas Analyzer

With a revived focus to create a permeant presence on the moon and in preparation for future Mars exploration, it is imperative that all re-sources are utilized to their fullest potential. In-Situ Resource Utilization (ISRU) will be critical for future mission success as it would enable independent operation of missions while minimally relying on the complex supply chain created between the Earth, moon and Mars. One of the most critical resources that have been identified for ISRU is the creation of liquid oxygen (O2) for not only breathable air, but also for rocket fuel. On the moon and potentially Mars, one of the most O2 rich resources is in the presence of regolith. Although there are numerous minerals within regolith and various processes to extract O2, this is not the scope of this paper. Since the O2 extraction method can vary, a critical standardized analytical method is needed to verify O2 (or oxygenated precursor compounds) for extraction efficiency and purity. Our group utilizes a modified consumer off-the-shelf (COTS), Residual Gas Analyzer (RGA) Single Quadrupole Mass Spectrometer (QMS). Due to the current field mission requirements, the gas analysis module will need to rely only on mass-to-charge ratios (m/z) and peak intensities to differentiate and quantitate targeted gas-phase reactants or products, i.e. carbon monoxide (CO), carbon dioxide (CO2), methane (CH4) and hydrogen (H2). However, due to solar wind implanted volatiles and various other compounds present in lunar regolith, such as nitrogen (N2), helium (He), and deuterium (D2), deconvolution and quantification of isobaric compounds becomes quite difficult. Specifically, the presence of N2 makes quantification of CO, an oxygenated precursor, difficult due to both compounds having a peak at m/z 28. Approaches to differentiate isobaric components: Initially, the solution to overcome isobaric overlap was to use isotopic ratios, particularly be-tween carbon-13 and nitrogen-15. Although limited literature discuss isotopic composition and attempt to quantify the ratios, variation is particularly high and limited to a few lunar regolith samples. The following were identified as potential approaches to quantify isobaric species, N2 and CO, using our RGA. Threshold Ionization. CO and N2 both have peaks at m/z 28, but only N2 is capable of producing a peak at m/z 7. While a N2 peak at m/z 7 is generally rare, instrument parameters can be optimized in order to maximize the peak intensity. Typically a standard ionization energy of 70 eV is used to monitor a batch process and would produce reliable results for a majority of the reactants or products that we are interested in quantifying. However, to analyze the rare molecular fragment of N2 (N2+ at m/z 7), a different ionization energy may be beneficial. Threshold Ionization Mass Spectrometry (TIMS) will be explored to optimize the N2+ peak at m/z 7 by varying parameters such as ionization energy and pressure. Therefore, a quantitative value at m/z 7 will be used to determine the product gas concentration of N2, which will be subtracted from the total concentration determined at m/z 28 enabling us to approximate the amount of CO. Secondary Detector (infrared gas detector, IR). Another approach to quantitate and differentiate be-tween isobaric components is to leverage alternative modes of detection. Unlike mass spectrometry, which generally uses a separation step prior to analysis (i.e. gas chromatography), IR produces energy that is specifically absorbed depending on the bond and configuration of the molecule. This technique could be leveraged since it is generally only active on non-symmetric molecules, i.e. CO. Utilizing concentrations of CO determined from another detector could help correct concentrations of CO obtained from the QMS. However, the inclusion of another detector adds additional mission requirements, such as power, software changes and avionics updates that add additional cost and schedule requirements.

mass spectrometry↗

Pulsed Lidar Measurements of Atmospheric CO2 Column Absorption in the ASCENDS 2011 Airborne Campaign

We have previously demonstrated an efficient pulsed, wavelength-resolved IPDA lidar technique for measuring the tropospheric CO2 concentrations as a candidate for NASA's ASCENDS mission. Our team participated in the 2010 ASCENDS airborne campaigns we flew airborne version of the CO2 and O2 lidar on the NASA DC-8. The CO2 lidar measures the atmospheric backscatter profiles and shape of the 1572.33 nm absorption line using 250 mW average laser power, 30 wavelength samples per scan and 300 scans per second. Most flights had 5-6 altitude steps to greater than 12 km, and clear CO2 line shapes were observed at all altitudes. Our post-flight analysis estimated the Iidar range and pulse energies at each wavelength every second. We then solved for the best-fit CO2 absorption line shape, and calculated the Differential Optical Depth (DOD) at the line peak. We compared these to CO2 DODs calculated from spectroscopy based on HITRAN 2008 and the conditions from airborne in-situ readings. Analysis of the 2010 measurements over the Pacific Ocean and Lamont OK shows the expected -linear change of the peak DOD with altitude. For measurements at altitudes greater than 6 km the random errors were approximately 0.3 ppm for 80 sec averaging times. After the 2010 flights we improved the airborne lidar's scan uniformity, calibration and receiver sensitivity. Our team participated in the seven ASCENDS science flights during late July and August 2011. These flights were made over a wide variety of surface and cloud conditions near the US, including over the central valley of California, over several mountain ranges, over both broken and solid stratus cloud deck over the Pacific Ocean, snow patches on mountain tops, over thin and broken clouds above the US Southwest and Iowa, and over forests near the WLEF tower in Wisconsin. Analyses show the retrievals of lidar range and CO2 column absorption, as wen as estimates of CO2 mixing ratio worked well when measuring over topography with rapidly changing height and reflectivity, through thin clouds and to stratus cloud tops. For regions where the CO2 concentration was relatively constant, the measured CO2 absorption profile (averaged for 50 sec) matched the predicted profile to better than 1% RMS error for all flight altitudes. For 1 & 10 second averaging, the scatter in the retrievals was limited by signal shot noise (i.e. the sigual photon count). Analysis to date shows the decrease in CO2 due to vegetation when flying easterward over the Great Plains as well as the increase in CO2 concentration in the vicinity ofthe coal-fired power plant in New Mexico. Examples of these and other results will be presented.

Abshire, James B.↗

In-Situ Reaction Monitoring for Lunar Applications Utilizing a Single Quadrupole Residual Gas Analyzer

With a revived focus to create a permanent presence on the moon and in preparation for future Mars exploration, it is imperative that all resources are utilized to their fullest potential.[1] In-Situ Resource Utilization (ISRU) will be critical for future mission success as it would enable independent operation of missions while minimally relying on the complex supply chain created between the Earth, moon and Mars. One of the most critical resources that have been identified for ISRU is the creation of liquid oxygen(LO2) for not only breathable air, but also for rocket propellant. On the moon and potentially Mars, one of the most O2 rich resources is in the presence of regolith.[2],[3] Although there are numerous minerals within regolith and various processes to extract O2,this is not the scope of this paper. Since the O2 extraction method can vary, a critical standardized analytical method is needed to verify O2(or oxygenated precursor compounds) for extraction efficiency and purity. Our group utilizes a modified consumer off-the-shelf (COTS), Residual Gas Analyzer (RGA) Single Quadrupole Mass Spectrometer (QMS). Due to the current field mission requirements, the gas analysis module will need to rely only on mass-to-charge ratios (m/z) and peak intensities to differentiate and quantitate targeted gas-phase reactants or products, i.e. carbon monoxide(CO), carbon dioxide (CO2), methane (CH4) and hydrogen (H2). However, due to solar wind implanted volatiles and various other compounds present in lunar regolith, such as nitrogen (N2), helium (He), and deuterium (D2), deconvolution and quantification of isobaric compounds becomes quite difficult. Specifically, the presence of N2 makes quantification of CO, an oxygenated precursor, difficult due to both compounds having a peak at m/z 28.

Mass Spectrometry↗

Rotation of the photospheric magnetic fields: A north-south asymmetry

During most of solar cycle 21 the large-scale photospheric field rotated more rapidly in the Northern Hemisphere than in the southern. The large-scale northern field rotated with a 26.9 day period (synodic), was centered at 15 degress N, and covered a latitude zone about 24 degrees wide. The large-scale southern field rotated with a periodicity of 28.1 days, was centered at 26 degrees S, and covered a latitude zone about 32 degrees wide. Our analysis showed rotational power at only a few discrete latitudes and frequencies in each hemisphere. The center of each peak lies near the sunspot differential rotation curve. The largest scale field contributes to the configuration of the coronal and interplanetary magnetic field (IMF). The strength of the first harmonic of the northern field suggests that this structure may be related to the 4-sector pattern observed in the IMF polarity. The southern field had much lower power at the first harmonic of the solar rotation rate and so would contribute only to a 2-sector structure in the IMF. These results were discovered in Fourier analysis of photospheric synoptic charts obtained at the Wilcox Solar Observatory from 1976 to 1986 and confirmed in higher resolution maps from the National Solar Observatory. Mt. Wilson magnetic field measurements from solar cycle 20 show a similar north-south asymmetry.

Antonucci, E.↗

Rotation of the photospheric magnetic fields - A north-south asymmetry

During most of solar cycle 21 the large-scale photospheric field rotated more rapidly in the Northern Hemisphere than in the southern. The large-scale northern field rotated with a 26.9 day period (synodic), was centered at 15 degrees N, and covered a latitude zone about 24 degrees wide. The large-scale southern field rotated with a periodicity of 28.1 days, was centered at 26 degrees S, and covered a latitude zone about 32 degrees wide. Our analysis showed rotational power at only a few discrete latitudes and frequencies in each hemisphere. The center of each peak lies near to the sunspot differential rotation curve. The largest scale field contributes to the configuration of the coronal and interplanetary magnetic field (IMF). The strength of the first harmonic of the northern field suggests that this structure may be related to the 4-sector pattern observed in the IMF polarity. The southern field had much lower power at the first harmonic of the solar rotation rate and so would contribute only to a 2-sector structure in the IMF. These results were discovered in Fourier analysis of photospheric synoptic charts obtained at the Wilcox Solar Observatory from 1976 to 1986 and confirmed in higher resolution maps from the National Solar Observatory. Mt. Wilson magnetic field measurements from solar cycle 20 show a similar north-south asymmetry.

Antonucci, E.↗

The Effect of Electrolyte Composition on Lithium Plating During Low Temperature Charging of Li-Ion Cells

In the present work, a number of additives have been investigated for their effect on the charge characteristics of cells containing low temperature, high ester content electrolytes (1.0 M LiPF6 in ethylene carbonate (EC) + ethyl methyl carbonate (EMC) + methyl propionate (MP) 20:20:60 vol % + X additive). These experimental three-electrode cells are composed of graphite anodes, LiNiCoAlO2 cathodes, and a lithium metal reference electrode. Cells were first subjected to electrochemical characterization at various temperatures, consisting of performing Electrochemical Impedance Spectroscopy (EIS), linear micropolarization and Tafel polarization measurement to determine the kinetic parameters for both the anodes and cathodes. Following electrochemical characterization, the cells were subjected to charging at decreasing temperatures using C/5 rates to 4.10V, with a constant potential C/50 current taper. Analysis of the C/20 discharge following the charge at low temperature revealed either the presence or absence of a high voltage plateau during the initial stages of the discharge. This plateau has been linked to the presence of lithium metal on the anode previously and was used as a measure for the extent of lithium plating in the cell. Differential analysis (dV/dQ) was applied as well to more clearly visualize the position of the high voltage plateau and use the peak position (x-axis) in the dV/dQ plot as a gauge for the amount of plating which took place in the cell on the prior charge. Most additives investigated increased the resistance of the anode and decreased the resistance of the cathode, thereby leading to an overall increase in plating observed at low temperature. One additive, LiFSI, was found to be beneficial during low temperature charging, however studies of electrode kinetics from the cell containing LiFSI did not reveal significant improvements compared to the baseline.

Jones, John-Paul↗

Analysis of He I 1083 nm Imaging Spectroscopy Using a Spectral Standard

We develop a technique. for the analysis of He I 1083 nanometer spectra which addresses several difficulties through determination of a continuum background by comparison with a well calibrated standard and through removal of nearby solar and telluric blends by differential comparison to an average spectrum. The method is compared with earlier analysis of imaging spectroscopy obtained at the National Solar Observatory/Kitt Peak Vacuum Telescope (NSO/KPVT) with the NASA/NSO Spectromagnetograph (SPM). We examine distributions of Doppler velocity and line width as a function of central intensity for an active region, filament, quiet Sun, and coronal hole. For our example, we find that line widths and central intensity are oppositely correlated in a coronal hole and quiet Sun. Line widths are comparable to the quiet sun in the active region, are systematically lower in the filament, and extend to higher values in the coronal hole. Outward velocities of approximately equal to 2 to 4 kilometers per second are typically observed in the coronal hole. The sensitivity of these results to analysis technique is discussed.

Malanushenko, Elena V.↗

The thermal phase of a large solar flare

EUV and X-ray observations are used to derive the differential emission measures, temperatures, densities, radiative and conductive cooling rates, and thermal energy content of a class 2B flare that occurred on September 7, 1973. The results of the analysis indicate that (1) most of the flare plasma was at temperatures between 3 and 10 million degrees; (2) the peak temperature decreased with time from about 8 million K to 5 million K over a period of 3.5 hours; (3) the differential emission measure steadily decreased with time at nearly all temperatures; (4) both radiation and conduction were important cooling mechanisms for the plasma at temperatures above 100,000 K; and (5) a substantial amount of energy, of the order of 3 x 10 to the 31st power ergs, was deposited in the flare loops after flare maximum. The empirically determined flare parameters are compared with similar parameters derived from a simple theoretical loop model.

Withbroe, G. L.↗

Nucleation and crystallization of Na2O-2CaO-3SiO2 glass by differential thermal analysis

DTA is presently used to characterize the nucleation and crystallization processes of the Na2O-2CaO-3SiO2 glass. A nucleation rate-temperaturelike curve is obtained by plotting either the reciprocal of the temperature corresponding to the crystallization peak maximum, or the height of the crystallization peak, as a function of nucleation temperature. The nucleation-temperature range for this glass composition, 550-650 C, and the maximum nucleation temperature of 600 + or - 5 C, are found to be in excellent agreement with those associated with the classical nucleation technique, followed by isothermal crystallization. It is noted that when most of the nucleation occurs during the DTA measurements, a modified Kissinger equation must be used to calculate the crystallization energy.

Xu, Xiaojie J.↗