Search NASA⌕ Search

SEARCH · Search NASA

Results for “peak estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Brillouin Sensing with PCA, and PCA-Based Neural Networks for Efficient Temperature Monitoring

This work explores peak estimation techniques in Brillouin Optical Time Domain Analysis (BOTDA), emphasizing both accuracy and efficiency. Euclidean distance measurement method is applied to principal components derived from Brillouin Gain Spectrum data. It offers a major speed advantage being 180 170 times faster than traditional curve fitting methods such as Lorentzian curve fitting, while maintaining similar accuracy. Additionally, a PCA- based neural network model shows significant reduction of peak estimation time compared to Lorentzian fitting. Results show Brillouin frequency shift errors lie under 0.75 MHz in both Euclidean distance-based and neural network-based methods, both of which utilize PCA components. For large data sets and long length fibers, PCA- assisted neural network for peak estimation would be an efficient solution.

Distributed optical fiber sensing↗

Efficient Signal Processing in BOTDA: Utilizing PCA and PCA-Based Neural Networks for Temperature Monitoring

This work presents a comparative analysis of the various signal processing techniques used in the Brillouin gain spectrum (BGS) peak estimation. Traditional fitting methods such as Lorentzian curve fitting (LCF) are slow and less effective in noisy data. PCA-based methods were tested on the experimental data: A Euclidian distance-based approach, and a probabilistic deep neural network (PDNN) based approach, both using 5 principal components to represent a single BGS. Both methods significantly reduce computational time with respect to LCF, whereas PDNN offers uncertainty insights along with the parameter value. Measuring a range of temperatures, analyzing accuracy, and speed, it can be concluded that PCA trained PDNN outperforms other methods, and appears to be helpful in scenario where large datasets are generated.

Brillouin optical time domain analysis↗

Advancing process-based flood frequency analysis for assessing flood hazard and population flood exposure

Recent studies have showcased the use of process-based hydrological models with Stochastic Storm Transposition (SST) techniques to conduct Flood Frequency Analysis (FFA). This framework, referred hereby FFA-SST, has proved to be a robust strategy to estimate peak flows of specific annual exceedance probability (e.g., 100-year peak flow) that can reflect natural and anthropogenic disturbances, including changes in land use and meteorological patterns. With the objective of advancing the FFA-SST framework, this study presents for the first time the use of an Integrated Surface-Subsurface Hydrological Model (ISSHM) to conduct FFA-SST by extending the analysis from peak flow responses to flood extent, enabling a unique view and analysis of flood hazard and population flood exposure at the basin scale. As a proof-of-concept, we used the ISSHM, Advanced Terrestrial Simulator (Amanzi-ATS) model, and the SST model, RainyDay, to conduct FFA-SST by simulating the flood response to 5,000 annual synthetic storm events in a 2,227 $km^2$ Southeast Texas watershed. We demonstrate that ATS, without site-specific calibration, provides a robust process-based representation of peak flows, flood extent, streamflow, evapotranspiration, soil moisture content, and water storage changes. Our results and analyses, covering frequency curves up to a 500-year return period for peak flows, basin inundation fractions, and the number of people exposed to flooding, offer a unique perspective to analyze flood impacts across spatial scales. Overall, this study provides critical insights for flood risk management by extending the FFA-SST framework to include both flood hazard and population flood exposure analyses at the basin scale. Such an approach will empower stakeholders and disaster emergency agencies with a more comprehensive understanding of flood impacts across the entire basin domain, facilitating informed decision-making for flood risk assessment and management.

58 GEOSCIENCES↗

Assessing the reliability of medical resource demand models in the context of COVID-19

Abstract Background Numerous medical resource demand models have been created as tools for governments or hospitals, aiming to predict the need for crucial resources like ventilators, hospital beds, personal protective equipment (PPE), and diagnostic kits during crises such as the COVID-19 pandemic. However, the reliability of these demand models remains uncertain. Methods Demand models typically consist of two main components: hospital use epidemiological models that predict hospitalizations or daily admissions, and a demand calculator that translates the outputs of the epidemiological model into predictions for resource usage. We conducted separate analyses to evaluate each of these components. In the first analysis, we validated various hospital use epidemiological models using a recent validation framework designed for epidemiological models. This allowed us to quantify the accuracy of the models in predicting critical aspects such as the date and magnitude of local COVID-19 peaks, among other factors. In the second analysis, we evaluated a range of demand calculators for ventilators, medical gowns, and COVID-19 test kits. To achieve this, we decoupled these demand calculators from the underlying epidemiological models and provided ground truth data for their inputs. This approach enabled a direct comparison of the demand calculators, comparing them against each other and actual usage data when available. The code is available athttps://doi.org/10.5281/zenodo.13712387. Results Performance varied greatly across the epidemiological models, with greater variability in COVID-19 hospital use predictions than for COVID-19 deaths as analyzed previously. Some models did not have any peaks. Among those that did, the models under-estimated date of peak approximately as often as they over-estimated, but were more likely to under-estimate magnitude of peak, with typical relative errors around 50%. Regarding demand calculator predictions, there was significant variability, including five-fold differences in predictions for gown models. Validation against actual or surrogate usage data illustrated the potential value of demand models while demonstrating their limitations. Conclusions The emerging field of demand modeling holds promise in averting medical resource shortages during future public health emergencies. However, achieving this potential necessitates focused efforts on standardization, transparency, and rigorous model validation before placing reliance on demand models in critical public health decision-making.

Medical Informatics↗

Climate change-resilient snowpack estimation in the Western United States

Abstract In the 21st century, warmer temperatures and changing atmospheric circulation will likely produce unprecedented changes in Western United States snowfall 1–3 , with impacts on the timing, amount, and spatial patterns of snowpack 4–7 . The ~900 snow pillow stations are indispensable to water resource management by measuring snow-water equivalent (SWE) 8,9 in strategic but fixed locations 10,11 . However, this network may not be impacted by climate change in the same way as the surrounding area 12 and thus fail to accurately represent unmeasured locations; climate change thereby threatens our ability to measure the effects of climate change on snow. In this work, we show that maintaining the current peak SWE estimation skill is nonetheless possible. We find that explicitly including spatial correlations—either from gridded observations or learned by the model—improves skill at predicting distributed snowpack from sparse observations by 184%. Existing artificial intelligence methods can be useful tools to harness the many available sources of snowpack information to estimate snowpack in a nonstationary climate.

54 ENVIRONMENTAL SCIENCES↗

Elucidating microstructural evolution and hardness variation across friction self-piercing riveted Al-7055 using synchrotron X-ray scattering and advanced microscopy techniques

Friction self-piercing riveting (FSPR) is a unique hybrid joining technique that combines the advantages of mechanical interlocking, frictional heat, and solid-state joining (if metallurgically compatible) to produce crack free joints in high strength and/or low-ductility alloys at room temperature. Here, in the current study, Al-7055 sheets were joined using FSPR for lightweight automotive applications and significant microhardness variations were observed across the joint cross-section. A detailed microstructural characterization at multiple length scales was carried out using advanced electron microscopy and X-ray scattering techniques to provide a fundamental understanding of the process-structure-property relationships. The relative contributions of microstructural characteristics at various length scales (i.e., grain size, dislocation density, solute concentration, precipitate nature) to strengthening were estimated using existent formulations (i.e., Hall-Petch, Taylor, precipitate bypass/shear equations) and correlated to the observed microhardness values across different regions. Small-angle X-ray scattering and scanning transmission electron microscopy revealed significant changes in the size and volume fraction of precipitate species, i.e., GP-I Zones, η′, and Mg/Zn solute co-clusters, depending on the process region. It was observed that the dissolution of the small η′/GP-I zones (T ∼ 150–200 °C) in the heat-affected zone were the key reason for the hardness drop. Further, it was shown that solid-solution, dislocation, grain size and solute co-cluster strengthening played a key role in the thermo-mechanically affected zone and grain-refined zone (GRZ). Finally, these observations were leveraged along with the Zener-Holloman relationship and grain size in the GRZ to estimate the peak joining temperature of the GRZ (∼ 350 °C) near the steel rivet.

aluminum 7xxx alloy↗

Seasonal variation in methane ebullition in a temperate hydropower reservoir impacts annualized estimates

Estimates of ebullitive methane (CH4) emissions from reservoirs are highly uncertain, often based on spatial and temporal upscaling from a limited number of sampling sites and periods. While some of these estimates may adjust for seasonal variation in temperature, they rarely account for drawdown and the resulting changes in site depth and the areal extent of the reservoir. In Douglas Reservoir (Tennessee, USA), we conducted monthly sampling of 20 sites over 1 year to capture temporal and spatial variation in CH4 ebullition. We then compared various approaches for obtaining annualized, whole-reservoir ebullition estimates. CH4 ebullition fluxes were zero-inflated and highly skewed, with fluxes rising appreciably above zero in July and peaking in autumn. Estimates that did not account for drawdown overestimated annualized rates by 20%, though with high uncertainty. Seasonal variability and hotspots strongly influence annualized ebullition estimates and are important to account for in inventories and global upscaling.

Cardall, Anna [Brigham Young University]↗

National Dataset of EV Charging Stations With Estimates of Load and Vehicle Throughput

Current data from the AFDC provide locations and many details about EV charging stations, but not estimates of their peak loads or the number of vehicles they can accommodate. This dataset will augment the AFDC charging station locations with estimates of transmission load and vehicle throughput based on engineering specifications of the chargers, charging patterns based on vehicle types, battery capacities, and user behavior.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Assessment of a Dual-purpose HP-TES for a Typical Year Comparing Different Climate Zones

Complete electrification of heating and cooling systems in the United States would overload the existing electrical grid. To this end, recent research efforts have focused on energy storage as one way to reduce ever-increasing peak electricity demands. One such technology is heat pump integrated thermal-energy storage (HP-TES) systems, which can enable load-shifting and reduce demand during peak hours. In this work, a Modelica model of a 4-Ton, dual-mode (heating and cooling) HP-TES system using a room-temperature phase-change material (PCM) integrated through a secondary hydronic loop was developed and simulated for a typical meteorological year in Riverside, CA (ASHRAE Climate Zone 2B), and Chicago, IL (ASHRAE Climate Zone 5A), for a DOE small office prototype building. The COP improvement and demand reduction were analyzed during the time-of-use peak hours along with the required recharge cycle energy demand. A typical summer in Riverside, CA resulted in model-predicted peak COP increases of 50 – 100% compared to the baseline heat pump, especially at higher outdoor temperatures, coupled with maximum peak energy reductions of 22%. During shoulder and winter season simulations, heating energy savings were higher as outdoor temperatures dropped below the PCM phase change temperature. For Chicago, IL, backup heating was necessary to meet the required system capacity for very cold ambient conditions, resulting in winter peak energy savings between 16 – 60% when accounting for backup heating requirements. The recharge energy was found to be mostly below the baseline HP energy during the peak. With improved component selections and controls, the recharge energy may be reduced. The outcomes from the simulations can provide first-order estimates for potential peak energy savings, challenges, and required controls in any location before conducting any field testing.

25 ENERGY STORAGE↗

0D, 1D, 2D, and 3D simulations of an idealized coaxial impedance-matched Marx generator

We have conducted 0D, 1D, 2D, and 3D simulations of an idealized coaxial impedance-matched Marx generator (IMG) []. The 0D calculations were conducted with a four-element circuit model; the 1D, 2D, and 3D calculations were conducted with highly resolved, fully electromagnetic representations. The IMG consists of 30 stages distributed axially and connected electrically in series. Each stage is powered by two bricks separated by 180° and connected electrically in parallel. Each brick comprises two opposite-polarity capacitors in series with a single switch. The bricks drive an internal impedance-matched coaxial transmission line terminated by a resistive load. The simulations neglect effects due to the switch-triggering circuit, the capacitor-charging circuit, external conducting boundaries, and reactive components of the load. We find dimensionality does not significantly affect the electrical power delivered by the IMG to its load: peak load powers estimated by the 0D, 1D, 2D, and 3D simulations agree to within 1%. The 3D calculations demonstrate that electromagnetic power radiated by the bricks, and axial gaps between stages, reduces the peak load power by less than ∼ 1 % . Each simulation assumes the load impedance is 34% above that at which the load power is maximized. Operating an IMG with such an overmatched load offers several advantages while decreasing the peak load power by only 2%. The 0D, 1D, 2D, and 3D models outlined herein could be adapted to assess computationally competing IMG designs, and conduct a variety of numerical IMG experiments, an IMG is constructed. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

When to vaccinate for seasonal influenza: check the peak forecast

Background Seasonal influenza infects 5-20% of people every year in the United States, resulting in hospitalizations, deaths, and adverse economic impacts. To mitigate these impacts, influenza vaccines are developed and distributed annually; however, growing evidence suggests that vaccine effectiveness (VE) wanes over the course of a flu season. Delaying influenza vaccination for older adults has attracted attention as a potential public health strategy. However, given the uncertainties in seasonal peak, vaccine effectiveness, and waning rates, postponing vaccination could also lead to increased morbidity, motivating an evaluation of a range of potential scenarios. The aim of this study was to investigate favorable age group-specific vaccination schedules that could lead to the greatest disease burden reduction. Methods We systematically investigated a broad range of vaccination start times for five age groups under six combinations of initial effectiveness and waning rates, based on influenza cases and vaccine uptake data from 10 influenza seasons. We defined the most favorable vaccination schedule as the one that resulted in the greatest reduction in disease burden. Results In scenarios with fast waning, all age groups benefit from delaying vaccination regardless of initial VE and peak timing. In scenarios with slower waning, results are mixed. For the ≥65 group, high initial VE and slow waning suggests that in early-peaking seasons, early vaccination most effectively reduces disease burden, while in late-peaking seasons delaying vaccination is most effective. For the ≥65 group in medium and low initial VE, and slow waning scenarios, delaying vaccination appears to prevent the greatest number of cases, regardless of whether the season peaks early or late. Conclusion The most favorable vaccination schedule is sensitive to changes in initial VE, waning rate, and peak timing. Given estimates of these quantities from statistical and immunological models and observations, our methods can inform vaccination recommendations in order to most effectively reduce the annual disease burden caused by seasonal influenza. Specifically, accurate peak timing forecasts for the upcoming season have the potential to guide decisions on when to vaccinate.

59 BASIC BIOLOGICAL SCIENCES↗

Characterization of spent nuclear fuel canister surface roughness using surface replicating molds

In this study we present a replication method to determine surface roughness and to identify surface features when a sample cannot be directly analyzed by conventional techniques. As a demonstration, this method was applied to an unused spent nuclear fuel dry storage canister to determine variation across different surface features. In this study, an initial material down-selection was performed to determine the best molding agent and determined that non-modified Polytek PlatSil23-75 provided the most accurate representation of the surface while providing good usability. Other materials that were considered include Polygel Brush-On 35 polyurethane rubber (with and without Pol-ease 2300 release agent), Polytek PlatSil73-25 silicone rubber (with and without PlatThix thickening agent and Pol-ease 2300 release agent), and Express STD vinylpolysiloxane impression putty. The ability of PlatSil73-25 to create an accurate surface replica was evaluated by creating surface molds of several locations on surface roughness standards representing ISO grade surfaces N 3 , N 5 , N 7 , and N 8 . Overall, the molds were able to accurately reproduce the expected roughness average (R a ) values, but systematically over-estimated the peak-valley maximum roughness (R z ) values. Using a 3D printed sample cell, several locations across the stainless steel spent nuclear fuel canister were sampled to determine the surface roughness. These measurements provided information regarding variability in normal surface roughness across the canister as well as a detailed evaluation on specific surface features (e.g., welds, grind marks, etc.). The results of these measurements can support development of dry storage canister ageing management programs, as surface roughness is an important factor for surface dust deposition and accumulation. This method can be applied more broadly to different surfaces beyond stainless steel to provide rapid, accurate surface replications for analytical evaluation by profilometry.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

GADRAS-DRF Validation for Safeguards and Custom Peak Fit Enhancements

In previous years, SGTech funded enhancements to the isotopics routine in the software called Gamma Detector Response and Analysis Software-Detector Response Function (GADRAS-DRF), including the addition of peak fit customization capabilities. A project was also funded that focused on implementing a peak-based model fitting routine, allowing model fitting to be performed without dependence on export-controlled cross-sections. In FY25 significant improvements were made to the custom peak fitting interface, accompanied by several validation studies within GADRAS-DRF. These studies encompassed IsotopeID performance, distributed source analysis, isotopics validation, and activity estimation. Additionally, the peak-only model fitting option was validated using an HPGe measurement of a rotating drum with line sources.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

ODIN: Characterizing the Three-dimensional Structure of Two Protocluster Complexes at z = 3.1

We present a detailed study of the 3D morphology of two extended associations of multiple protoclusters at z = 3.1. These protocluster "complexes," designated COSMOS-z3.1-A and COSMOS-z3.1-C, are the most prominent overdensities of z = 3.1 Lyα emitters (LAEs) identified in the COSMOS field by the One-hundred-deg$^{2}$ DECam Imaging in Narrowbands survey. These protocluster complexes have been followed up with extensive spectroscopy from Keck, Gemini, and DESI. Using a probabilistic method that combines photometrically selected and spectroscopically confirmed LAEs, we reconstruct the 3D structure of these complexes on scales of ≈50 cMpc. We validate our reconstruction method using the IllustrisTNG300-1 cosmological hydrodynamical simulation and show that it consistently outperforms approaches relying solely on spectroscopic data. The resulting 3D maps reveal that both complexes are irregular and elongated along a single axis, emphasizing the impact of sightline on our perception of structure morphology. The complexes consist of multiple density peaks, 10 in COSMOS-z3.1-A and 4 in COSMOS-z3.1-C. The former is confirmed to be a proto-supercluster, similar to Hyperion at z = 2.4 but observed at an even earlier epoch. Multiple "tails" connected to the cores of the density peaks are seen, likely representing cosmic filaments feeding into these extremely overdense regions. The 3D reconstructions further provide strong evidence that Lyα blobs preferentially reside in the outskirts of the highest density regions. Descendant mass estimates of the density peaks suggest that COSMOS-z3.1-A and COSMOS-z3.1-C will evolve to become ultramassive structures by z = 0, with total masses log ( M / M ,⊙ ,) ≳ 15.3 , exceeding that of Coma.

Ramakrishnan, Vandana [Purdue U., West Lafayette] ↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Magnetic excitations from the hexagonal spin clusters in the 𝑆 = $\frac{1}{2}$ distorted honeycomb lattice antiferromagnet Cu 2 ⁢(pymca)⁢ 3 ⁢(ClO 4 )

Cu 2 ⁢(pymca) ⁢3 (ClO 4 ) (pymca: pyrimidine-2-carboxylate) consists of a slightly distorted honeycomb lattice of Cu 2+ spins, which shows no long-range magnetic order down to 0.6 K. A magnetization study revealed 1/3 and 2/3 plateau phases [A. Okutani et al., J. Phys. Soc. Jpn. 88, 013703 (2019)], which is not expected for regular honeycomb antiferromagnets. Inelastic neutron scattering experiments were performed using a powder sample to investigate the exchange interactions of this material. The spin excitations from the singlet ground state to the first three triplet states, predicted from the antiferromagnetic hexagonal spin cluster interacting with 3.9 meV, were observed. Using the exact diagonalization methods, the intercluster coupling was estimated from the excitation peak width to be about 20% of the intracluster interaction, which is consistent with the previously reported value. Finally, our exchange path model explains the anisotropic exchange interactions in the distorted honeycomb plane.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Red Noise–based False Alarm Thresholds for Astrophysical Periodograms via Whittle’s Approximation to the Likelihood

Astronomers who search for periodic signals using Lomb–Scargle periodograms rely on false alarm level (FAL) estimates to identify statistically significant peaks. Although FALs are often calculated from white noise models, many astronomical time series suffer from red noise. Prewhitening is a statistical technique in which a continuum model is subtracted from the log power spectrum estimate, after which the observer can proceed with a white-noise treatment. Here we present a prewhitening-based method of calculating frequency-dependent FALs. We fit power laws and autoregressive models of order 1 to each Lomb–Scargle periodogram by minimizing the Whittle approximation to the negative log-likelihood (NLL), then calculate FALs based on the best-fit model power spectrum. Our technique is a novel extension of the Whittle NLL to datasets with uneven time sampling. We demonstrate FAL calculations using observations of α Cen B, GJ 581, HD 192310, synthetic data from the radial velocity (RV) fitting challenge, and Kepler observations of a differential rotator. The Kepler data analysis shows that only true rotation signals are detected by red noise FALs, while white noise FALs suggest all spurious peaks in the low-frequency range are significant. A high-frequency sinusoid injected into α Cen B logR$'$ HK observations exceeds the 1% red noise FAL despite having only 8.9% of the power of the dominant rotation signal. In a periodogram of HD 192310 RVs, peaks associated with differential rotation and planets are detected against the 5% red noise FAL without iterative model fitting or subtraction. The software for calculating red noise–based FALs is available on GitHub.

Astrostatistics (1882)↗

Impact of Limited Degree of Freedom Drag Coefficients on a Floating Offshore Wind Turbine Simulation

The worldwide effort to design and commission floating offshore wind turbines (FOWT) is motivating the need for reliable numerical models that adequately represent their physical behavior under realistic sea states. However, properly representing the hydrodynamic quadratic damping for FOWT remains uncertain, because of its dependency on the choice of drag coefficients (dimensionless or not). It is hypothesized that the limited degree of freedom (DoF) drag coefficient formulation that uses only translational drag coefficients causes mischaracterization of the rotational DoF drag, leading to underestimation of FOWT global loads, such as tower base fore-aft shear. To address these hydrodynamic modeling uncertainties, different quadratic drag models implemented in the open-source mid-fidelity simulation tool, OpenFAST, were investigated and compared with the experimental data from the Offshore Code Comparison Collaboration, Continued, with Correlation (OC5) project. The tower base fore-aft shear and up-wave mooring line tension were compared under an irregular wave loading condition to demonstrate the effects of the different damping models. Two types of hydrodynamic quadratic drag formulations were considered: (1) member-based dimensionless drag coefficients applied only at the translational DoF (namely limited-DoF drag model) and (2) quadratic drag matrix model (in dimensional form). Based on the results, the former consistently underestimated the 95th percentile peak loads and spectral responses when compared to the OC5 experimental data. In contrast, the drag matrix models reduced errors in estimates of the tower base shear peak load by 7–10% compared to the limited-DoF drag model. The underestimation in the tower base fore-aft shear was thus inferred be related to mischaracterization of the rotational pitch drag and the heave motion/drag by the limited-DoF model.

17 WIND ENERGY↗