Search NASA⌕ Search

SEARCH · Search NASA

Results for “peak temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

SU-E-T-354: Peak Temperature Ratio of TLD Glow Curves to Investigate the Spatial Dependence of LET in a Clinical Proton Beam

Purpose: Use the ratio of the two high temperature peaks (HTR) in TLD 700 glow curves to investigate spatial dependence of the linear energy transfer (LET) in proton beams. Studies show that the relative biological effectiveness (RBE) depends upon the physical dose as well as its spatial distribution. Although proton therapy uses a spatially invariant RBE of 1.1, studies suggest that the RBE increases in the distal edge of a spread out Bragg peak (SOBP) due to the increased LET. Methods: Glow curve studies in TLD 700 show that the 280 C temperature peak is more sensitive to LET radiation than the 210 C temperature peak. Therefore, the areas under the individual temperature peaks for TLDs irradiated in a proton beam normalized to the peak ratio for 6 MV photons are used to determine the HTR to obtain information on its LET. TLD 700 chips with dimensions 0.31×0.31×0.038 cc are irradiated with 90 MeV protons at varying depths in a specially designed blue wax phantom to investigate LET spatial dependence. Results: Five TLDs were placed at five different depths of the percent depth dose curve (PDD) of range 16.2 cm: center of the SOPB and approximately at the 99% distal edge, 90%, 75% and 25% of the PDD, respectively. HTR was 1.3 at the center of the SOBP and varied from 2.2 to 3.9 which can be related to an LET variation from 0.5 to 18 KeV/μ via calibration with radiation beams of varying LET. Conclusion: HTR data show a spatially invariant LET slightly greater than the 6 MV radiations in the SOBP, but a rapidly increasing LET at the end of the proton range. These results indicate a spatial variation in RBE with potential treatment consequences when selecting treatment margins to minimize the uncertainties in proton RBE.

07 ISOTOPE AND RADIATION SOURCES↗

Experimental constraints on models for origins of chondrules: Peak temperatures

Chondrule peak temperature constraints for mathematical models pertaining to chondrule origin are discussed in this article. The peak temperatures experienced by chondrules provide a parameter that may allow discrimination between alternative heating mechanisms. Successful mechanisms must provide just enough energy to reach such temperatures and not overshoot them. In principle, determination of peak temperatures from chondrule textures and experiments that duplicate them should be very easy. However, this approach is complicated by the fact that there are several different experimental paths that reproduce chondrule properties. The key texture depends not only on the peak temperature but also on the heating time and, in the case of totally molten droplets, on interactions with other particles. Addressed here are different types of peak temperature constraints; (1) near-liquidus melting; (2) flash melting; (3) dust seeding; (4) volatile element constraints; and (5) barred olivine chondrules.

Hewins, R. H.↗

Temperature peaking at beginning of breakdown in 2.45 GHz pulsed off-resonance electron cyclotron resonance ion source hydrogen plasma

An experimental study of temperature and density evolution during breakdown in off-resonance ECR hydrogen plasma is presented. Under square 2.45 GHz microwave excitation pulses with a frequency of 50 Hz and relative high microwave power, unexpected transient temperature peaks that reach 18 eV during 20 {mu}s are reported at very beginning of plasma breakdown. Decays of such peaks reach final stable temperatures of 5 eV at flat top microwave excitation pulse. Evidence of interplay between incoming power and duty cycle giving different kind of plasma parameters evolutions engaged to microwave coupling times is observed. Under relative high power conditions where short microwave coupling times are recorded, high temperature peaks are measured. However, for lower incoming powers and longer coupling times, temperature evolves gradually to a higher final temperature without peaking. On the other hand, the early instant where temperature peaks are observed also suggest a possible connection with preglow processes during breakdown in ECRIS plasmas.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Additive Manufacturing of Miniaturized Peak Temperature Monitors for In-Pile Applications

Passive monitoring techniques have been used for peak temperature measurements during irradiation tests by exploiting the melting point of well-characterized materials. Recent efforts to expand the capabilities of such peak temperature detection instrumentation include the development and testing of additively manufactured (AM) melt wires. In an effort to demonstrate and benchmark the performance and reliability of AM melt wires, we conducted a study to compare prototypical standard melt wires to an AM melt wire capsule, composed of printed aluminum, zinc, and tin melt wires. The lowest melting-point material used was Sn, with a melting point of approximately 230 °C, Zn melts at approximately 420 °C, and the high melting-point material was aluminum, with an approximate melting point of 660 °C. Through differential scanning calorimetry and furnace testing we show that the performance of our AM melt wire capsule was consistent with that of the standard melt-wire capsule, highlighting a path towards miniaturized peak-temperature sensors for in-pile sensor applications.

36 MATERIALS SCIENCE↗

A relationship between peak temperature drop and velocity differential in a microburst

Results from numerical microburst simulations using the Terminal Area Simulation System (Proctor, 1987) are used to develop a relationship between wind velocity differential and peak temperature drop. The numerical model and the relationships derived from the model are described. The relationship between peak temperature drop and differential wind velocity is shown to be valid during microburst development, for all precipitation shaft intensities and diameters. It is found that the relationship is not valid for low-reflectivity microburst events or in the presence of ground-based stable layers. The use of the relationship in IR wind shear detection systems is considered.

Proctor, Fred H.↗

Evaluation of Increased Peak Temperatures for Spent Fuel Cladding Performance during Dry Storage (Rev.1)

NUREG-2214, “Managing Aging Processes in Storage (MAPS) Report,” (2019) documents the technical basis for age-related degradation mechanisms on spent nuclear fuel assemblies during dry storage operations. The technical bases have been reviewed, and hoop cladding stress calculations were conducted using the Fuel Analysis under Steady-state and Transients (FAST) code at elevated normal condition temperatures of 425°C and 450°C, and at an off-normal and accident conditions temperature of 600°C. The NUREG-2214 conclusions are substantiated by the referenced literature. The calculations demonstrate that the aging mechanisms primarily driven by hoop stress such as hydride reorientation, delayed hydride cracking, thermal and athermal (low-temperature) creep, and localized mechanical overload are either not credible or do not compromise the fuel assembly’s performance for increased peak normal condition temperatures of 425°C or 450°C during the up to 60-year dry storage period. Other aging mechanisms considered are also not credible for compromising the fuel assembly’s performance during 60-year dry storage with a peak temperature of 400ºC as specified in ISG – 11 Rev. 3, and the same is indicated for the increased peak normal condition temperatures of 425°C or 450°C.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Ambitious efforts on residual emissions can reduce CO 2 removal and lower peak temperatures in a net-zero future

Carbon dioxide removal (CDR) is expected to play a critical role in reaching net zero CO 2 and especially net zero greenhouse gase (GHG) emissions. However, the extent to which the role of CDR in counterbalancing residual emissions can be reduced has not yet been fully quantified. Here, we use a state-of-the-art integrated assessment model to develop a 'Maximum Sectoral Effort' scenario which features global emissions policies alongside ambitious effort across sectors to reduce their gross GHG emissions and thereby the CDR required for offsets. We find that these efforts can reduce CDR by over 50% globally, increase both the relative and absolute role of the land sink in storing carbon, and more evenly distribute CDR contributions and associated side-effects across regions compared to CO 2 pricing alone. Furthermore, the lower cumulative CO 2 and nonCO 2 emissions leads to earlier and lower peak temperatures. Emphasizing reductions in gross, in addition to net emissions while disallowing the substitution of less durable CDR for offsets can therefore reduce both physical and transition risks associated with high CDR deployment and temperature overshoot.

54 ENVIRONMENTAL SCIENCES↗

MELT WIRE SENSORS AVAILABLE TO DETERMINE PEAK TEMPERATURES IN ATR IRRADIATION TESTING

In April 2007, the Department of Energy (DOE) designated the Advanced Test Reactor (ATR) a National Scientific User Facility (NSUF) to advance US leadership in nuclear science and technology. By attracting new users from universities, laboratories, and industry, the ATR will support basic and applied nuclear research and development and help address the nation's energy security needs. In support of this new program, the Idaho National Laboratory (INL) has developed in-house capabilities to fabricate, test, and qualify new and enhanced temperature sensors for irradiation testing. Although most efforts emphasize sensors capable of providing real-time data, selected tasks have been completed to enhance sensors provided in irradiation locations where instrumentation leads cannot be included, such as drop-in capsule and Hydraulic Shuttle Irradiation System (HSIS) or 'rabbit' locations. To meet the need for these locations, the INL has developed melt wire temperature sensors for use in ATR irradiation testing. Differential scanning calorimetry and environmental testing of prototypical sensors was used to develop a library of 28 melt wire materials, capable of detecting peak irradiation temperatures ranging from 85 to 1500°C. This paper will discuss the development work and present test results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MCNP AND CFD MODELING OF A SODIUM FAST REACTOR SUB-ASSEMBLY CHANNEL TO CAPTURE LOCALIZED TEMPERATURE PEAKING

Typical evaluation tools for sodium-cooled fast reactors (SFR) use simplified neutronic/thermal models to efficiently compute the power and temperature distributions within the core. However, their modeling capability can be limited in extreme cases such as when sharp inter-assembly power gradients occur, or for non-standard SFR assembly geometries. Higher fidelity tools that rely on Monte Carlo methods for neutron transport, and Computational Fluid Dynamics (CFD) for thermal analysis, are better suited in these instances. The higher accuracy comes at the cost of higher computational expense. MCNP and STAR CCM+ were selected for this analysis. While MCNP is capable of generating pin-level power distributions for a whole-core SFR model, it is prohibitively expensive to then conduct CFD analysis for every single assembly. A semi-empirical model was therefore developed to rapidly estimate pin temperature distributions throughout the whole core. It relies on a geometric correction factor for turbulent flow-mixing. The correction factor is obtained from a CFD simulation of a single fuel assembly with a uniform power distribution and an adiabatic boundary condition. Without using CFD, each sub-channel outlet temperature is calculated separately using 1-D heat-balance and Nusselt number correlations and the MCNP calculated pin-powers. The rudimentary 1-D model is then corrected for the flow-mixing effect based on the CFD data. The temperature calculation is performed by a code written in the Python language called CFD Monte-Carlo Developed Reconstruction of Sub-channel at a Quasi-Representative Level (CMDR-SQRL). CMDR-SQRL was shown to adequately predict CFD evaluated temperature distribution for a wide range of SFR configurations, including an extreme case with fuel assemblies nearby containing moderating material. The agreement demonstrates how geometric and power-driven effects can be decoupled within an SFR assembly. CMDR-SQRL is intended to be mainly used for scoping studies to provide core-wide evaluations efficiently.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Feasibility of peak temperature targets in light of institutional constraints

Despite faster-than-expected progress in clean energy technology deployment, global annual CO 2 emissions have increased from 2020 to 2023. The feasibility of limiting warming to 1.5 °C is therefore questioned. Here we present a model intercomparison study that accounts for emissions trends until 2023 and compares cost-effective scenarios to alternative scenarios with institutional, geophysical and technological feasibility constraints and enablers informed by previous literature. Our results show that the most ambitious mitigation trajectories with updated climate information still manage to limit peak warming to below 1.6 °C (‘low overshoot’) with around 50% likelihood. However, feasibility constraints, especially in the institutional dimension, decrease this maximum likelihood considerably to 5–45%. Accelerated energy demand transformation can reduce costs for staying below 2 °C but have only a limited impact on further increasing the likelihood of limiting warming to 1.6 °C. Our study helps to establish a new benchmark of mitigation scenarios that goes beyond the dominant cost-effective scenario design.

54 ENVIRONMENTAL SCIENCES↗

Synthesis and thermal stability of W-doped VO{sub 2} nanocrystals

Highlights: {yields} The VO{sub 2} nanocrystals with a nearly spherical morphology with size ranging from 50 to 100 nm were synthesized by using V{sub 2}O{sub 5} and oxalic acid as precursors via a thermolysis method. {yields} The W dopant is in the W{sup 6+} form, and there is a small amount of V{sup 3+} in the VO{sub 2} nanocrystals. VO{sub 2} (R) nanocrystals with phase transition temperature at room temperature were obtained with 2.5 at% W-doing. {yields} A high stability upon heating-cooling cycles was observed with respect to MIT temperature, peak temperature and latent heat of the phase transition due to both the size effect and the existence of V{sup 3+} in the VO{sub 2} nanocrystals. -- Abstract: Pure and W-doped vanadium dioxide nanocrystals have been synthesized by using V{sub 2}O{sub 5} and oxalic acid as precursors via a thermolysis method. The VO{sub 2} nanocrystals have a nearly spherical morphology with size ranging from 50 to 100 nm. The metal-insulator transition (MIT) temperature of the nanocrystals decreases with increasing W-doping content. The successive heat-induced fatigue character of the MIT in W-doped VO{sub 2} nanocrystals was investigated by DSC analysis together with structural study, and a high stability upon heating-cooling cycles was found with respect to MIT temperature, peak temperature and latent heat of the phase transition.

36 MATERIALS SCIENCE↗

FEMAXI-V benchmarking study on peak temperature and fission gas release prediction of PWR rod fuel

The present paper reports a study of FEMAXI-V code and related report on code benchmarking. Capabilities of the FEMAXI-V code to predict the thermal and fission gas release have been tested on MOX fuels in LWRs which has been done in SCK{center_dot}CEN and Belgonucleaire by using PRIMO MOX rod BD8 irradiation experiment after V Sobolev as reported O. J. Ott. Base irradiation in the BR3 reactor, the BD8 rod was transported to CEA-Saclay for irradiation in the OSIRIS reactor (ramp power excursion). The irradiation device used for the PRIMO ramps was the ISABELLE 1 loop, installed on a movable structure of the core periphery. The power variations were obtained by inwards/backwards movements of the loop in the core water. The preconditioning phase for rod BD8 occurred at a peak power level of 189 W/cm with a hold time of 27 hours. The subsequent power excursion rate amounted to 77 W/ (cm.min), reaching a terminal peak power level of 395 W/cm that lasted for 20 hours.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermoluminescence and the shock and reheating history of meteorites. III - The shergottites

Thermoluminescence (TL) measurements on Shergotty, ALHA 77005, Zagami, and EETA 79001 (lithology A) have been used to obtain further information on the shock history of these meteorites. The level of TL sensitivity in the shergottites varied by a factor of 10, but was always low, probably reflecting the amount of crystalline material in the maskelynite. There are trends in the TL peak temperature, peak width, and TL sensitivity which are believed to be associated with different proportions of feldspar in high- and low-temperature forms. This interpretation is consistent with the observed changes induced in the TL properties by annealing shergottites at 400-900 C. It is suggested that the observed trends were produced during postshock crystallization at a variety of cooling rates, the increasing order of cooling rate being EETA 79001, Zagami, ALHA 77005, and Shergotty, and that there is high-temperature feldspar present in all the samples. This implies a postshock temperature above 600 C, and a small (less than 10 m) size of the ejecta. Current theories are well able to explain how objects of this size could have been ejected from Mars.

Hasan, F. A.↗

Synthesis and characterization of rare earth doped ZrO{sub 2} nanophosphors

In this paper, we reports synthesis, characterization and thermoluminescence (TL) glow curves of europium and dysprosium activated zirconium dioxide (ZrO{sub 2}: Eu{sup 3+}, Dy{sup 3+}) phosphor with variable concentration of europium and fixed concentration of dysprosium. The sample was prepared by the Solid state method; thereafter, the TL glow curves were recorded for different concentration of europium with 20 min UV exposure at a heating rate of 6.7°C/s. The trapping parameters for synthesized phosphors of ZrO{sub 2}: Eu{sup 3+}, Dy{sup 3+} have been calculated by using a peak shape method. The sample was characterized for structural analysis by XRD (X-ray diffraction) and morphological analysis by FEGSEM (field emission gun scanning electron microscope) and FTIR (Fourier transform infrared spectroscopy). The effect of variable europium concentration and fixed dysprosium concentration on TL studies were interpreted and the formation of trap depth and reproducibility of prepared phosphor were analyzed by TL glow curves. The peak temperature on TL less than 200°C shows the formation of deep trapping in prepared sample. The high temperature peak shows the less fading and more stability in prepared sample.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spatially resolved measurements of electron density of a magnetically confined split-ring resonator source

Laser-collisional induced fluorescence is used to study the plasma generated by a split-ring resonator discharge under an external cusp shaped magnetic field created by permanent magnets. The electron density and electron temperature are measured for a helium plasma at different pressures, powers, and magnet field strengths. It is found that the magnetic fields produce higher electron temperatures with peak temperatures of ∼3 eV, while the no magnet case has peak temperatures of ∼0.8 eV. Conversely, the peak electron density is obtained in the no magnet case at a value of ∼1.9 × 1011 cm−3. This indicates that the cusp-field did magnetize the electrons, but contrary to expectations, it resulted in a decrease in electron density. This is believed to be due to the magnetic field having negative effects on the resonance of the plasma source.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗