Search NASA⌕ Search

SEARCH · Search NASA

Results for “peak temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Experimental constraints on models for origins of chondrules: Peak temperatures

Chondrule peak temperature constraints for mathematical models pertaining to chondrule origin are discussed in this article. The peak temperatures experienced by chondrules provide a parameter that may allow discrimination between alternative heating mechanisms. Successful mechanisms must provide just enough energy to reach such temperatures and not overshoot them. In principle, determination of peak temperatures from chondrule textures and experiments that duplicate them should be very easy. However, this approach is complicated by the fact that there are several different experimental paths that reproduce chondrule properties. The key texture depends not only on the peak temperature but also on the heating time and, in the case of totally molten droplets, on interactions with other particles. Addressed here are different types of peak temperature constraints; (1) near-liquidus melting; (2) flash melting; (3) dust seeding; (4) volatile element constraints; and (5) barred olivine chondrules.

Hewins, R. H.↗

A relationship between peak temperature drop and velocity differential in a microburst

Results from numerical microburst simulations using the Terminal Area Simulation System (Proctor, 1987) are used to develop a relationship between wind velocity differential and peak temperature drop. The numerical model and the relationships derived from the model are described. The relationship between peak temperature drop and differential wind velocity is shown to be valid during microburst development, for all precipitation shaft intensities and diameters. It is found that the relationship is not valid for low-reflectivity microburst events or in the presence of ground-based stable layers. The use of the relationship in IR wind shear detection systems is considered.

Proctor, Fred H.↗

Thermoluminescence and the shock and reheating history of meteorites. III - The shergottites

Thermoluminescence (TL) measurements on Shergotty, ALHA 77005, Zagami, and EETA 79001 (lithology A) have been used to obtain further information on the shock history of these meteorites. The level of TL sensitivity in the shergottites varied by a factor of 10, but was always low, probably reflecting the amount of crystalline material in the maskelynite. There are trends in the TL peak temperature, peak width, and TL sensitivity which are believed to be associated with different proportions of feldspar in high- and low-temperature forms. This interpretation is consistent with the observed changes induced in the TL properties by annealing shergottites at 400-900 C. It is suggested that the observed trends were produced during postshock crystallization at a variety of cooling rates, the increasing order of cooling rate being EETA 79001, Zagami, ALHA 77005, and Shergotty, and that there is high-temperature feldspar present in all the samples. This implies a postshock temperature above 600 C, and a small (less than 10 m) size of the ejecta. Current theories are well able to explain how objects of this size could have been ejected from Mars.

Hasan, F. A.↗

The Cooling History and Structure of the Ordinary Chondrite Parent Bodies

Most major meteorite classes exhibit significant ranges of metamorphism. The effects of metamorphism have been extensively characterized, but the heat source(s) and the metamorphic environment are unknown. Proposed beat sources include Al-26, Fe-60, electromagnetic induction, and impact. It is typically assumed that metamorphism occurred in parent bodies of some sort, but it uncertain whether these bodies were highly structured ("onion skins") or were chaotic mixes of material ("rubble piles"). The lack of simple trends of metallographic cooling rates with petrologic type has been considered supportive of both concepts. In this study, we use induced thermoluminescence (TL) as an indicator of thermal history. The TL of ordinary chondrites is produced by sodic feldspar, and the induced TL peak temperature is related to its crystallographic order/disorder. Ordered feldspar has TL peak temperatures of approx. 120 C, and disordered feldspar has TL peak temperatures of approx. 220 C. While ordered feldspar can be easily disordered in the laboratory by heating above 650 C and is easily quenched in the disordered form, producing ordered feldspar requires cooling at geologic cooling rates. We have measured the induced TL properties of 101 equilibrated ordinary chondrites, including 49 H, 29 L, and 23 LL chondrites. For the H chondrites there is an apparent trend of decreasing induced TL peak temperature with increasing petrologic type. H4 chondrites exhibit a tight range of TL peak temperatures, 190 C - 200 C, while H6 chondrites exhibit TL peak temperatures between 180 C and 190 C. H5 chondrites cover the range between H4 and H6, and also extend up to 210 C. Similar results are obtained for LL chondfiles and most L6 chondrites have lower induced TL peak temperatures than L5 chondrites.

Benoit, P. H.↗

Metamorphism and aqueous alteration in low petrographic type ordinary chondrites

In order to investigate the relative importance of dry metamorphism and aqueous alteration in the history of chondruies, chondruies were hand-picked from the Semarkona (petrographic type 3.0), Bishunpur (3. 1), Chainpur (3.4), Dhajala (3.8) and Allegan (5) chondrites, and matrix samples were extracted from the first three ordinary chondrites. The thermoluminescence (TL) properties of all the samples were measured, and appropriate subsets of the samples were analyzed by electron-microprobe and radiochemical neutron activation and the water and H-isotopic composition determined. The TL data for chondrules from Semarkona and Bishunpur scatter widely showing no unambiguous trends, although group B1 chondrules tend to have lower sensitivities and lower peak temperatures compared with group A5 chondrules. It is argued that these data reflect the variety of processes accompanying chondrule formation. The chondrules show remarkably uniform contents of the highly labile elements, indicating mineralogical control on abundance and volatile loss from silicates and loss and recondensation of mobile chalcophiles and siderophiles in some cases. Very high D/H values (up to approx. 8000% SMOW) are observed in certain Semarkona chondrules, a confirmation of earlier work. With increasing petrographic type, mean TL sensitivities of the chondrules increase, the spread of values within an individual meteorite decreases, and peak temperatures and peak widths show trends indicating that the TL is mainly produced by feldspar and that dry, thermal metamorphism is the dominant secondary process experienced by the chondrules. The TL sensitivities of matrix samples also increase with petrographic type. Chainpur matrix samples show the same spread of peak temperatures and peak widths as Chainpur chondruies, indicating metamorphism-related changes in the feldspar are responsible for the TL of the matrix. The TL data for the Semarkona and Bishunpur matrix samples provide, at best, only weak evidence for aqueous alteration, but the matrix contains H with approximately terrestrial D/H values, even though it contains much water. Secondary processes (probably aqueous alteration) presumably lowered the D/H of the matrix and certain chondrules. While chondrule properties appear to be governed primarily by formation processes and subsequent metamorphism, the matrix of Semarkona has a more complex history involving aqueous alteration as a meteorite-wide process.

Xie, T.↗

Atmospheric entry heating of micrometeorites

A computer simulation of the atmospheric entry deceleration and heating of cosmic dust particles has been developed and the predicted peak temperatures are compared to the earlier closed-form mathematical solutions of Whipple (195) and Fraundorf (1980). A 20-micron diameter particle of density 1 gm/cu cm having a velocity of 10 km/s at infinity and entering the atmosphere at normal incidence reaches a peak temperature of 1159 K. The duration of the heating pulse is about 8 s but the particle remains within 100 K of the peak temperature for only 1.0 s. As the angle of incidence decreases, the peak temperature reached on entry also decreases, and the duration of the temperature pulse increases. Comparison with the Whipple amd Fraundorf models indicates that they accurately assess the entry heating for cosmic dust particles of moderate or higher densities and entry angles near normal incidence. As particle density decreases or the entry angle nears grazing incidence, they overestimate the peak temperature.

Flynn, G. J.↗

On the possibility of Earth reentry simulation of shallow angle Jupiter entry

Possible Earth reentry simulation of shallow-angle (3 to 30 deg) Jupiter entry was investigated in terms of four parameters of the bow shock layer ahead of a blunt vehicle: peak (equilibrium) temperature, peak pressure, peak inward radiative flux, and time-integrated radiative flux. It is shown that simulation ranging from fair to good can be achieved. Reentry is easiest (lowest Earth reentry speed) at steep Earth reentry, in the Earth entry speed range of 15 to 22 km/sec, for both the Jupiter nominal and cool atmospheres. Increased Earth speed is required, generally, for increasing Jupiter entry angle, and for increasing temperature, radiative flux, time-integrated flux and pressure, in that order.

Mcronald, A. D.↗

Evaluation of alternative phase change materials for energy storage in solar dynamic applications

The performance of fluoride salt and metallic thermal energy storage materials are compared in terms of basic performance as applied to solar dynamic power generation. Specific performance considerations include uniformity of cycle inlet temperature, peak cavity temperature, TES utilization, and system weights. Also investigated were means of enhancing the thermal conductivity of the salts and its effect on the system performance.

Crane, R. A.↗

Design Analysis of a High Temperature Radiator for the Variable Specific Impulse Magnetoplasma Rocket (VASIMR)

The Variable Specific Impulse Magnetoplasma Rocket (VASIMR), currently under development by Ad Astra Rocket Company, is a unique propulsion system that can potentially change the way space propulsion is performed. VASIMR's efficiency, when compared to that of a conventional chemical rocket, reduce propellant needed for exploration missions by a factor of 10. Currently plans include flight tests of a 200 kW VASIMR system, titled VF-200, on the International Space Station. The VF-200 will consist of two 100 kW thruster units packaged together in one engine bus. Each thruster unit has a unique heat rejection requirement of about 27 kW over a firing time of 15 minutes. In order to control rocket core temperatures, peak operating temperatures of about 300 C are expected within the thermal control loop. Design of a high temperature radiator is a unique challenge for the vehicle design. This paper will discuss the path taken to develop a steady state and transient based radiator design. The paper will describe radiator design options for the VASIMR thermal control system for use on ISS as well as future exploration vehicles.

Sheth, Rubik B.↗

Langmuir Probe Measurements Within the Discharge Channel of the 20-kW NASA-300M and NASA-300MS Hall Thrusters

NASA is presently developing a high-power, high-efficiency, long-lifetime Hall thruster for the Solar Electric Propulsion Technology Demonstration Mission. In support of this task, studies have been performed on the 20-kW NASA-300M Hall thruster to aid in the overall design process. The ability to incorporate magnetic shielding into a high-power Hall thruster was also investigated with the NASA- 300MS, a modified version of the NASA-300M. The inclusion of magnetic shielding would allow the thruster to push existing state-of-the-art technology in regards to service lifetime, one of the goals of the Technology Demonstration Mission. Langmuir probe measurements were taken within the discharge channels of both thrusters in order to characterize differences at higher power levels, as well as validate ongoing modeling efforts using the axisymmetric code Hall2De. Flush-mounted Langmuir probes were also used within the channel of the NASA-300MS to verify that magnetic shielding was successfully applied. Measurements taken from 300 V, 10 kW to 600 V, 20 kW have shown plasma potentials near anode potential and electron temperatures of 4 to 12 eV at the walls near the thruster exit plane of the NASA-300MS, verifying magnetic shielding and validating the design process at this power level. Channel centerline measurements on the NASA-300M from 300 V, 10 kW to 500 V, 20 kW show the electron temperature peak at approximately 0.1 to 0.2 channel lengths upstream of the exit plane, with magnitudes increasing with discharge voltage. The acceleration profiles appear to be centered about the exit plane with a width of approximately 0.3 to 0.4 channel lengths. Channel centerline measurements on the NASA-300MS were found to be more challenging due to additional probe heating. Ionization and acceleration zones appeared to move downstream on the NASA-300MS compared to the NASA-300M, as expected based on the shift in peak radial magnetic field. Additional measurements or alternative diagnostics will be needed to verify peak electron temperatures in the NASA-300MS and compare them with model predictions.

Hall thruster↗

History of water on Mars - A biological perspective

A general scenario is developed for the history of liquid water on the surface of Mars, according to which the history of water on Mars can be divided into four epochs based on the fundamental temperature and pressure characteristics. In Epoch I, the mean annual temperature is assumed to have been above freezing and the pressure to have been above 1 atm; liquid water was widespread and life could have arisen and become abundant. In Epoch II, the mean annual temperature fell below freezing, but peak temperatures were above freezing; In Epoch II ice-covered lakes could have provided a habitat for life. In Epoch III, both the mean and the peak temperatures were below freezing, and only transient liquid water would be possible; under these conditions, microbial ecosystems living in endolithic rock 'greenhouses' could have continued to survive. Finally, in Epoch IV, the pressure dropped to near the triple point pressure of water; at this stage, life on the surface of Mars would have become extinct.

Mckay, Christopher P.↗

Cometary dust: A thermal criterion to identify cometary samples among the collected interplanetary dust

The relative proportions of the cometary and the asteroidal contributions to the interplanetary dust have not yet been definitively established. These proportions may vary with time as a result of major catastrophic disruptions in the main belt or the appearance of fresh, active comets. Dermott et al. and Reach suggest the debris from catastrophic collisions in the main belt can account for most of the zodiacal cloud particles. Earth collection of these asteroidal particles is strongly favored by near-Earth gravitational enhancement. However, comets are observed to produce interplanetary dust particles (IDP's), and the identification of cometary IDP's would allow inferences of the compositions, mineralogies, and physical properties of the comets. The peak temperatures reached by IDP's on atmospheric entry indicate the distribution of IDP velocities. Each IDP contains many internal thermometers: minerals that transform above certain temperatures, volatile elements that are lost sequentially with increasing temperatures, solar flare tracks that anneal at different temperatures in different minerals, and solar-implanted noble gases that outgas progressively with temperature. Thus, limits on the peak temperature reached by each IDP on Earth atmospheric entry can be set. Other aspects of this investigation are covered.

Flynn, George J.↗

Fatigue-environment interactions in a SiC/Ti-15-3 composite

Load-controlled isothermal and nonisothermal fatigue lives of a (0-deg)s SiC/Ti-15-3 were evaluated at temperatures between 150 and 550 C and a target strain range of about 0.45 percent. In nonisothermal fatigue tests, load was first cycled at minimum temperature and then temperature was cycled at zero load. For fatigue tests with peak temperatures at or above 300 C, fatigue life was dramatically reduced compared to that at 150 C. The shortest life was produced by the nonisothermal test with the greatest temperature range (Delta T = 400 C) and highest peak temperature (T(max) = 550 C). Vacuum testing showed that much of the life reduction under isothermal and nonisothermal conditions was related to environmental effects, although the nature of the fatigue-environment interaction was decidedly different for the isothermal and nonisothermal test cycles which were studied.

Gayda, J.↗

Thermodynamic and fluid mechanic analysis of rapid pressurization in a dead-end tube

Three models have been applied to very rapid compression of oxygen in a dead-ended tube. Pressures as high as 41 MPa (6000 psi) leading to peak temperatures of 1400 K are predicted. These temperatures are well in excess of the autoignition temperature (750 K) of teflon, a frequently used material for lining hoses employed in oxygen service. These findings are in accord with experiments that have resulted in ignition and combustion of the teflon, leading to the combustion of the stainless steel braiding and catastrophic failure. The system analyzed was representative of a capped off-high-pressure oxygen line, which could be part of a larger system. Pressurization of the larger system would lead to compression in the dead-end line, and possible ignition of the teflon liner. The model consists of a large plenum containing oxygen at the desired pressure (500 to 6000 psi). The plenum is connected via a fast acting valve to a stainless steel tube 2 cm inside diameter. Opening times are on the order of 15 ms. Downstream of the valve is an orifice sized to increase filling times to around 100 ms. The total length from the valve to the dead-end is 150 cm. The distance from the valve to the orifice is 95 cm. The models describe the fluid mechanics and thermodynamics of the flow, and do not include any combustion phenomena. A purely thermodynamic model assumes filling to be complete upstream of the orifice before any gas passes through the orifice. This simplification is reasonable based on experiment and computer modeling. Results show that peak temperatures as high as 4800 K can result from recompression of the gas after expanding through the orifice. An approximate transient model without an orifice was developed assuming an isentropic compression process. An analytical solution was obtained. Results indicated that fill times can be considerably shorter than valve opening times. The third model was a finite difference, 1-D transient compressible flow model. Results from the code show the recompression effect but predict much lower peak temperatures than the thermodynamic model.

Leslie, Ian H.↗

Modified Laser Flash Method for Thermal Properties Measurements and the Influence of Heat Convection

The study examined the effect of natural convection in applying the modified laser flash method to measure thermal properties of semiconductor melts. Common laser flash method uses a laser pulse to heat one side of a thin circular sample and measures the temperature response of the other side. Thermal diffusivity can be calculations based on a heat conduction analysis. For semiconductor melt, the sample is contained in a specially designed quartz cell with optical windows on both sides. When laser heats the vertical melt surface, the resulting natural convection can introduce errors in calculation based on heat conduction model alone. The effect of natural convection was studied by CFD simulations with experimental verification by temperature measurement. The CFD results indicated that natural convection would decrease the time needed for the rear side to reach its peak temperature, and also decrease the peak temperature slightly in our experimental configuration. Using the experimental data, the calculation using only heat conduction model resulted in a thermal diffusivity value is about 7.7% lower than that from the model with natural convection. Specific heat capacity was about the same, and the difference is within 1.6%, regardless of heat transfer models.

Lin, Bochuan↗

Thermal Analysis of a Metallic Wing Glove for a Mach-8 Boundary-Layer Experiment

A metallic 'glove' structure has been built and attached to the wing of the Pegasus(trademark) space booster. An experiment on the upper surface of the glove has been designed to help validate boundary-layer stability codes in a free-flight environment. Three-dimensional thermal analyses have been performed to ensure that the glove structure design would be within allowable temperature limits in the experiment test section of the upper skin of the glove. Temperature results obtained from the design-case analysis show a peak temperature at the leading edge of 490 F. For the upper surface of the glove, approximately 3 in. back from the leading edge, temperature calculations indicate transition occurs at approximately 45 sec into the flight profile. A worst-case heating analysis has also been performed to ensure that the glove structure would not have any detrimental effects on the primary objective of the Pegasus a launch. A peak temperature of 805 F has been calculated on the leading edge of the glove structure. The temperatures predicted from the design case are well within the temperature limits of the glove structure, and the worst-case heating analysis temperature results are acceptable for the mission objectives.

Gong, Leslie↗

Description of the manufacturing challenges in producing the high-temperature reusable surface insulation for the thermal protection system of the Space Shuttle

The paper describes the high-temperature reusable surface insulation for the thermal protection system of the Space Shuttle. This system protects the Space Shuttle Orbiter on reentry and it is an externally attached, rigidized, fibrous silica, machined into 15 x 20 cm tiles. The tiles constitute the High-Temperature Reusable Surface Insulation (HRSI) system, and are used on over 70 percent of the exterior surface where peak temperatures range from 400 to 1260 C. Carbon-carbon leading edges are used in areas where peak temperatures exceed 1650 C, and a Nomex felt flexible insulation system is used in regions below 400 C. Approximately 32,000 tiles are used in the HRSI system, and due to vehicle configuration and aerodynamic requirements no two tiles are alike.

Forsberg, K.↗

Producing the high temperature reusable surface insulation for the thermal protection system of the Space Shuttle

The primary insulation system used to protect the space shuttle orbiter on reentry is an externally attached, rigidized, fibrous silica which has been machined into tiles. The tiles constitute the temperature reusable surface insulation system and are used on over 70 percent of the vehicle exterior surface where peak temperatures range from 400 to 1260 C. Cargon-carbon leading edges are used in areas where peak temperatures exceed 1650 C and a felt flexible insulation is used in regions below 400 C. Approximately 32,000 tiles are used in the HRST system and because of vehicle configuration, aerodynamic requirements, and weight considerations no two tiles are alike. Fabrication and quality control procedures are described.

Forgsberg, K.↗