Search NASA⌕ Search

SEARCH · Search NASA

Results for “performance data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

An Overview of the Earth Observing System MODIS Instrument Performance, Data Systems Performance, and Data Products Status and Availability

The Moderate Resolution Imaging Spectroradiometer (MODIS) on the Earth Observing System (EOS) Terra Mission began to produce data in February 2000. Now, approximately 2 years from that time, the instrument is operating well. All subsystems of the instrument are performing as expected, the signal-to-noise (S/N) performance meets or exceeds specifications, band-to-band registration meets specifications, geodetic registration of observations is nearing 50 meters (one sigma) and the spectral bands are located where they were intended to be pre-launch and attendant gains and offsets are stable to date. The data systems have performed well and are producing a wide variety of data products useful for scientific and applications studies in relatively consistent fashion extending from November 2000 to the present. Within the approximately 40 MODIS data products, several are new and represent powerful and exciting capabilities. The remainder of the MODIS products exceed or, at a minimum, match the capabilities of products from heritage sensors such as, for example, the Advanced Very High Resolution Radiometer (AVHRR). Efforts are underway to provide data sets for the greater Earth science community and to improve access to these products at the various Distributed Active Archive Centers (DAAC's) or through Direct Broadcast (DB) stations. The MODIS instrument on the EOS Aqua mission should also be expected to be in orbit and functioning in the Spring of 2002.

Salomonson, Vincent V.↗

Preliminary design of an auxiliary power unit for the space shuttle. Volume 5: Selected system cycle performance data

Detailed cycle steady-state performance data are presented for the final auxiliary power unit (APU) system configuration. The selection configuration is a hydrogen-oxygen APU incorporating a recuperator to utilize the exhaust energy and using the cycle hydrogen flow as a means of cooling the component heat loads. The data are given in the form of computer printouts and provide the following: (1) verification of the adequacy of the design to meet the problem statement for steady-state performance; (2) overall system performance data for the vehicle system analyst to determine propellant consumption and hydraulic fluid temperature as a function for varying mission profiles, propellant inlet conditions, etc.; and (3) detailed component performance and cycle state point data to show what is happening in the cycle as a function of the external forcing functions.

Hamilton, M. L.↗

Performance Data Gathering and Representation from Fixed-Size Statistical Data

The two commonly-used performance data types in the super-computing community, statistics and event traces, are discussed and compared. Statistical data are much more compact but lack the probative power event traces offer. Event traces, on the other hand, are unbounded and can easily fill up the entire file system during program execution. In this paper, we propose an innovative methodology for performance data gathering and representation that offers a middle ground. Two basic ideas are employed: the use of averages to replace recording data for each instance and 'formulae' to represent sequences associated with communication and control flow. The user can trade off tracing overhead, trace data size with data quality incrementally. In other words, the user will be able to limit the amount of trace data collected and, at the same time, carry out some of the analysis event traces offer using space-time views. With the help of a few simple examples, we illustrate the use of these techniques in performance tuning and compare the quality of the traces we collected with event traces. We found that the trace files thus obtained are, indeed, small, bounded and predictable before program execution, and that the quality of the space-time views generated from these statistical data are excellent. Furthermore, experimental results showed that the formulae proposed were able to capture all the sequences associated with 11 of the 15 applications tested. The performance of the formulae can be incrementally improved by allocating more memory at runtime to learn longer sequences.

Yan, Jerry C.↗

Analysis of small-scale rotor hover performance data

Rotor hover-performance data from a 1/6-scale helicopter rotor are analyzed and the data sets compared for the effects of ambient wind, test stand configuration, differing test facilities, and scaling. The data are also compared to full scale hover data. The data exhibited high scatter, not entirely due to ambient wind conditions. Effects of download on the test stand proved to be the most significant influence on the measured data. Small-scale data correlated resonably well with full scale data; the correlation did not improve with Reynolds number corrections.

Kitaplioglu, Cahit↗

Performance Data Errors in Air Carrier Operations: Causes and Countermeasures

Several airline accidents have occurred in recent years as the result of erroneous weight or performance data used to calculate V-speeds, flap/trim settings, required runway lengths, and/or required climb gradients. In this report we consider 4 recent studies of performance data error, report our own study of ASRS-reported incidents, and provide countermeasures that can reduce vulnerability to accidents caused by performance data errors. Performance data are generated through a lengthy process involving several employee groups and computer and/or paper-based systems. Although much of the airline indUStry 's concern has focused on errors pilots make in entering FMS data, we determined that errors occur at every stage of the process and that errors by ground personnel are probably at least as frequent and certainly as consequential as errors by pilots. Most of the errors we examined could in principle have been trapped by effective use of existing procedures or technology; however, the fact that they were not trapped anywhere indicates the need for better countermeasures. Existing procedures are often inadequately designed to mesh with the ways humans process information. Because procedures often do not take into account the ways in which information flows in actual flight ops and time pressures and interruptions experienced by pilots and ground personnel, vulnerability to error is greater. Some aspects of NextGen operations may exacerbate this vulnerability. We identify measures to reduce the number of errors and to help catch the errors that occur.

countermeasures↗

Thermal Performance Data Services (TPDS)

Initiated as a NASA Engineering and Safety Center (NESC) assessment in 2009, the Thermal Performance Database (TPDB) was a response to the need for a centralized thermal performance data archive. The assessment was renamed Thermal Performance Data Services (TPDS) in 2012; the undertaking has had two fronts of activity: the development of a repository software application and the collection of historical thermal performance data sets from dispersed sources within the thermal performance community. This assessment has delivered a foundational tool on which additional features should be built to increase efficiency, expand the protection of critical Agency investments, and provide new discipline-advancing work opportunities. This report contains the information from the assessment.

French, Richard T.↗

Space tug economic analysis study. Volume 2: Tug concepts analysis. Appendix: Tug design and performance data base

The tug design and performance data base for the economic analysis of space tug operation are presented. A compendium of the detailed design and performance information from the data base is developed. The design data are parametric across a range of reusable space tug sizes. The performance curves are generated for selected point designs of expendable orbit injection stages and reusable tugs. Data are presented in the form of graphs for various modes of operation.

Source record↗

Integrating performance data collection, analysis, and visualization

An integrated data collection, analysis, and data visualization environment is described for a specific parallel system - the Intel iPSC/2 hypercube. The data collection components of the environment encompass software event tracing at the operating system with a program level and a hardware-based performance monitoring system used to capture software events. A visualization system based on the X-window environment permits dynamic display and reduction of performance data. A performance data collection, analysis, and visualization environment makes it possible to access the effects of architectural and system software variations.

Malony, Allen D.↗

Performance Data Report: Space Medicine Division, Human Research Program, Behavioural Health and Performance Research Element

This report is the result of a collaborative effort between NASA?s Behavioral Health & Performance (BHP) Research and Operations Group to investigate and determine the availability of data pertaining to behavioral performance (and other pertinent variables) that have been collected by the laboratories at NASA?s Johnson Space Center. BHP?s Operations and Research groups collaborated to systematically identify what types of performance data are needed in relevant BHP performance domains and also to conduct structured interviews with NASA personnel to identify which data do or do not exist currently (and for instances where such data exist, to evaluate the type, quality, accessibility, and confidentiality of those data). The authors defined outcome categories of performance that encapsulate BHP performance domains, mapped BHP Research Risks and Gaps onto those performance outcome categories, and identified and prioritized indicators for each outcome category. The team identified key points of contact (subject matter experts [SMEs]) as potential interviewees, created a template for structured interview questions about sources and accessibility of performance data, and coordinated and conducted structured interviews with the SMEs. The methodology, results, and implications of this effort, as well as forward work needed, are discussed in this report.

Shea, Camille↗

Design and Performance Data for 81 Ah FNC Cells

Design and performance data for 81 Ah FNC cells are given. The conclusions are: that a sealed Ni-Cd cells are not limited to 50 Ah with the FNC design; energy densities of 40 Wh/kg in a conservative high Cd, high electrolyte design have been demonstrated; uniform ATP data and LEO cycling performance is being demonstrated; internal cell pressures remain low under all conditions; and no conditioning is necessary under any LEO profile; accelerated LEO cycling exhibits performance well beyond traditional space Ni-Cd cells.

Cohen, F.↗

LANL High-Performance Data System (HPDS)

The Los Alamos High-Performance Data System (HPDS) is being developed to meet the very large data storage and data handling requirements of a high-performance computing environment. The HPDS will consist of fast, large-capacity storage devices that are directly connected to a high-speed network and managed by software distributed in workstations. The HPDS model, the HPDS implementation approach, and experiences with a prototype disk array storage system are presented.

Collins, M. William↗

Comparison of computer-acquired performance data from several fixed spaced planar diodes.

Performance data are compared for thermionic diodes with various tungsten or rhenium emitters and niobium or molybdenum collectors. The planar converters have guard-ringed collectors and a fixed space of 10 mils (0.254 mm). The data were acquired using a computer. The parameters are the temperatures of the emitter Te, collector Tc, and cesium reservoir Tr. The composite plots have constant Te and varying Tc or Tr or both. The envelope and composite plots having constant Te are presented. The diodes were tested at increments between 1500 and 2000 K for the emitters, 750 and 1100 K for the collectors, and 520 and 650 K for the reservoirs.

Manista, E. J.↗