Fractional punishment of fixed-ratio performance
Fixed-ratio performance patterns of pigeon key- peck responses to fractional punishments by electric shock
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Fixed-ratio performance patterns of pigeon key- peck responses to fractional punishments by electric shock
A new derivation of Power Duration Curve is presented and applied to analysis of photovoltaic system life cycle cost. The effect of non-unity Performance Ratio and non-unity Availability on the power duration curve are illustrated. The effect of these two key performance indicators on calculation of life cycle cost and PV system design optimization (optimal DC/AC ratio) are illustrated as example applications of the method.
High/variable mixture ratio O2/H2 candidate engine cycles are examined for earth-to-orbit vehicle application. Engine performance and power balance information are presented for the candidate cycles relative to chamber pressure, bulk density, and mixture ratio. Included in the cycle screening are concepts where a third fluid (liquid nitrogen) is used to achieve a variable mixture ratio over the trajectory from liftoff to earth orbit. The third fluid cycles offer a very low risk, fully reusable, low operation cost alternative to high/variable mixture ratio bipropellant cycles. Variable mixture ratio engines with extendible nozzle are slightly lower performing than a single mixture ratio engine (MR = 7:1) with extendible nozzle. Dual expander engines (MR = 7:1) have slightly better performance than the single mixture ratio engine. Dual fuel dual expander engines offer a 16 percent improvement over the single mixture ratio engine.
The prescriptive path is the most widely used approach for commercial code compliance in the United States. Though easy to implement, prescriptive approaches do not typically discriminate between minimally compliant, high-performing and poorly performing HVAC system configurations. Hence, to meet aggressive energy and carbon reduction goals, it is clear that energy codes will need to transition from prescriptive to performance-based approaches, a transition that is riddled with several challenges. This paper discusses a new HVAC system-based performance approach (HVAC System Performance) which provides a simpler solution to HVAV system evaluation compared to whole building performance, while keeping tradeoffs limited to specific building systems. The Total System Performance Ratio (TSPR) is a metric for evaluation of overall system efficiency instead of individual component efficiency, a solution which could also eventually facilitate the transition to a 100% performance-based code structure. TSPR is a ratio that compares the annual heating and cooling load of a building to the annual energy consumed by the building’s HVAC system. A calculation software tool has been developed for determining a building’s TSPR. Already incorporated into the 2018 Washington State Energy Code, this approach is also being evaluated by ASHRAE Standard 90.l Project Committee and has the potential to provide a comprehensive performance-based approach for HVAC system evaluation and analysis.
Computer program for computation of chemical equilibrium compositions, rocket performance, and chapman-jouguet detonations
The aerodynamic performance of a 0.5 aspect ratio turbine vane configuration with coolant flow ejection was experimentally determined in a full annular cascade. The vanes were tested at a nominal mean section ideal critical velocity ratio of 0.890 over a range of primary to coolant total temperature ratio from 1.0 to 2.08 and a range of coolant to primary total pressure ratio from 1.0 to 1.4 which corresponded to coolant flows from 3.0 to 10.7 percent of the primary flow. The variations in primary and thermodynamic efficiency and exit flow conditions with circumferential and radial position were obtained.
This paper examines the feasibility of using waste heat from wastewater treatment plants (WWTPs) for water desalination. A model was developed to utilize waste heat from the gensets at As Samra WWTP in Jordan, using real data and TRNSYS® software to calculate available waste heat. The desalination process was then modeled with ASPEN PLUS® software, focusing on multi-effect desalination (MED). Both series and parallel configurations for the MED system were compared. The study investigated the effects of system feeding flow rate, feeding pressure, and heat input on productivity, performance ratio, and recovery ratio. The study also introduces a novel optimization technique combining machine learning and modern optimization algorithms to maximize system productivity and performance. Initially, a decision tree regression (DTR) model is developed to establish relationships between key independent variables (flow rate, feed pressure, and heat input) and dependent variables (productivity, performance ratio, and recovery ratio). The Pelican Optimization Algorithm (POA) is then used to identify the optimal values of the independent variables for maximum productivity and performance. The results show that using a series configuration yields a system productivity of 3984.2 kg/hr, a performance ratio of 3.78, and a recovery ratio of 0.991 at a feed flow rate of 4000 kg/hr, feed pressure of 3 bars, and heat input of 719 kW. Optimal productivity (4421 kg/hr), performance ratio (3.81), and recovery ratio (0.851) are achieved at a feed flow rate of 5166 kg/hr, feed pressure of 3.2 bars, and heat input of 794 kW. In conclusion, the techno-economic assessment indicates a levelized cost of water of 1.63 USD/m 3 for parallel configurations and 1.65 USD/m 3 for series configurations, with a payback period of less than two years.
Effect of body cross sections and width-height ratio on performance of bodies and delta-wing- body combinations at Mach 6.9
The aerodynamic performance of a low aspect ratio turbine vane designed with coolant flow ejection holes on the vane surfaces was experimentally determined in a full-annular cascade with the coolant ejection holes plugged. The purpose was to establish a baseline for comparison with tests where flow is ejected from the vane surfaces. The vanes were tested over a mean-section ideal critical velocity ratio range of 0.64 to 0.98. This ideal critical velocity ratio corresponds to the vane inlet total to vane aftermixed static pressure ratio at the mean section. The variations in vane efficiency and aftermixed flow conditions with circumferential and radial position were obtained.
This article analyzes data from 2,200 photovoltaic systems collected through the Open Solar Performance and Reliability Clearinghouse (oSPARC, 2018) to draw conclusions about the measured performance of the systems, how it compares to expectations, and how wide the variation is. The systems range in size from 2 kW to 1,200 kW, with an average size of 229 kW, and were activated in oSPARC between March 13, 2007 and Dec. 16, 2016. Data regarding co-incident insolation and ambient temperature are provided through the oSPARC platform for the population of systems and summarized here. Results indicate that - after correcting for measured insolation, derating for temperature, and correcting for balance-of-system efficiency and degradation as a result of system age - the performance ratio of these 2,200 systems averages 91.7%. Adjusting for known parameters such as age and efficiency, the ratio would ideally be 100%. Thus, the 'underperformance' of this system sample is measured at 9.3% and suggests that as much as 9.3% could be recovered if the systems were caused to perform as expected through optimal operation and maintenance. Efforts to correlate the performance ratio with environmental conditions resulted in very low coefficients of regression, but the method already normalizes for actual site insolation and temperature, which are responsible for much of the site-specific variation. An exemption is air-quality nonattainment areas, where the measured performance of plants averages 86.9% and is consistently lower than the average of 95.9% in areas that are in compliance with air quality standards, likely because of particulate matter such as diesel soot exacerbating the soiling rate.
Scale formation that drastically increases thermal resistance and reduces freshwater production remains a critical challenge in thermal desalination. Novel designs of falling film evaporator and optimal operating condition hold great promise to mitigate scale formation, and increase heat transfer performance and fresh water production. In this work, CFD simulation based machine learning and multi-objective optimization are performed to identify optimal conditions and tube arrangement for evaporator. Non-dominated sorting genetic algorithm is adopted to determine and analyze the optimal pareto front for multiple objectives in desalination criteria. The errors of training, validation, and testing set are computed to identify an optimal hyperparameter set. For performance ratio, fouling resistance, and water production rate, the average relative error is 2.26%, 3.67%, and 3.24%. At pareto front, both performance ratio and water production rate increase at high temperature with fouling resistance (thermal resistance of the fouling layer) increasing as well. Tradeoffs between mitigating scale formation and enhancing desalination performance are evaluated in optimizations for different objectives. Finally, potential optima are identified and can be applied as guidelines to determine evaporator design and system operating conditions.
Vehicle lightweighting is an essential component to the automotive industry to improve fuel economy of internal combustion engine (ICE) vehicles to meet ever improving emission standards and to improve the range of electric vehicles (EV). Composite materials offer high specific modulus and specific strength, which makes them appealing for these light weighting efforts. Sheet molding compounds (SMC) are particularly interesting from an automotive perspective because of the relatively low cost and high volume of producing SMC parts. Traditionally, composite materials for automotive application are glass fiber reinforced because of the attractive price - performance ratio, but basalt fibers are a cost and recycling competitive reinforcement alternative in this market. The aim of this project was to examine the feasibility of utilizing basalt fiber for automotive applications. More specifically, an effort was made to examine different fiber sizings on basalt fiber combined with vinyl-ester (VE) resin, and their performance as part of an SMC process. In addition to offering vehicle lightweighting with fiber reinforced polymer composites, basalt fiber is a fully recyclable material and thus supports the IACMI technical goal of: Demonstrate that the technology is capable at a sufficient scale for >80% recyclability or reuse of fiber reinforced polymer composites in five years into useful components with projected cost and quality at commercial scale competitive with virgin materials on a pathway to 95% recyclability or reuse starting in ten years. Three different fiber sizings were applied to a continuous roving of basalt fiber and compared to a traditional Electrical/Chemical Resistance (E-CR) glass fiber that is typically used in these types of applications. Fiber tows were examined for Loss on Ignition percentage (LOI%), Tex, and tow strength. Some sizings clearly outperformed others, and the ability to process these fibers on a pilot scale SMC line was demonstrated. A test plan for the manufacturing and mechanical testing of SMC panels was developed. This work continues outside the time frame allocated for this project. When this work is completed, it will be added to this report and posted as Appendix C. Glass fiber reinforced SMC materials have already proven feasible as a light weighting method for traditionally steel parts like the Volkswagen (VW) Atlas lift-gate (Figure 1); this project team is seeking the feasibility of basalt fiber as a drop-in replacement for glass fiber reinforced SMC. Sizing development for basalt fibers has proven that the mechanical properties are better than E-glass and closer to S-glass, which makes it an interesting material for SMC applications. Better mechanical properties translate to less material needed to achieve load case requirement for target applications. The business case has already been demonstrated for 100,000 parts per year of glass fiber reinforced SMC Atlas lift-gates compared to traditional steel manufacturing processes. Reduced overhead and assembly costs are offset by glass fiber SMC higher cost per kg beyond 100,000 parts per year, which is still a relatively low volume for the automotive industry. For basalt fiber reinforced SMC to become feasible for automotive applications, the price-performance ratio has to be precisely determined. Based on the mechanical performance it is possible to establish a range of applications and technical solutions in which the potential of basalt SMC can be utilized, while the price of the material can be used to compile the business case for such applications. Based on these business cases and the sustainability indicators, glass fiber reinforcement (or other) materials can be directly substituted. Volkswagen’s commitment to reducing carbon emissions cannot be understated. Basalt fiber shows promise of reducing the carbon footprint in SMC materials, especially if sizing optimizations can be made with thermoplastic based SMC. To fully realize the value of basalt fiber reinforced materials, a lifecycle cost analysis should be performed on basalt’s production and recycling, and then compared against E-glass. From this assessment, a true judgement can be made on the commercialization potential of this material. Figure 1. Example of Fiber Reinforced Polymer Composite Liftgate As a conclusion, we can state that Mafic basalt fiber is not a direct replacement for E-glass or E-CR glass based on price, but should be considered a technical solution when E-glass does not provide adequate performance in a composite design and S-glass, aramid and carbon fibers are too costly. Mafic basalt fiber can be placed on the high-performance fiber spectrum next to S-glass for performance but at one third the price. It should be considered for more technically challenging structural designs wherein the performance can demonstrate 20-25% performance enhancement over E-glass to elicit more strength or a weight reduction. Both Michelman and Mafic produce thermoplastic sizings which, in combination with Nylon and polypropylene resin and fibers, can further advance high speed composite implementations while maintaining an eco-friendly manufacturing process.
We describe how performance problems can be “masked,” or not readily evident by several causes: by photovoltaic (PV) system configuration (such as the size of the PV array capacity relative to the size of the inverter and the resultant clipped operating mode); by instrumentation design, installation, and maintenance (such as a misaligned or dirty pyranometer); by contract clauses (when operational availability is transformed to contractual availability, which excludes many factors); and by identified management and operational practices (such as reporting on a portfolio of plants rather than individually). A simple method based on a duration curve is introduced to overcome shortcomings of Performance Ratio based on nameplate capacity and Performance Index based on hourly simulation when quantifying masking effects, and inverter clipping and pyranometer soiling are presented as two examples of the new method. With a better understanding of the non-transparency of masking issues, stakeholders can better interpret performance data and deliver improved AC and DC plant conditions through PV system operation and maintenance (O&M) for improved performance, reduced O&M costs, and a more consistently delivered, and reduced, levelized cost of energy (LCOE).
In photovoltaic power ratings, a single solar spectrum, AM1.5, is the de facto standard for record laboratory efficiencies, commercial module specifications, and performance ratios of solar power plants. More detailed energy analysis that accounts for local spectral irradiance, along with temperature and broadband irradiance, reduces forecast errors to expand the grid utility of solar energy. Here, ground-level measurements of spectral irradiance collected worldwide have been pooled to provide a sampling of geographic, seasonal, and diurnal variation. Applied to nine solar cell types, the resulting divergence in solar cell efficiencies illustrates that a single spectrum is insufficient for comparisons of cells with different spectral responses. Cells with two or more junctions tend to have efficiencies below that under the standard spectrum. Silicon exhibits the least spectral sensitivity: relative weekly site variation ranges from 1% in Lima, Peru to 14% in Edmonton, Canada.
Abstract Additive manufacturing processes, such as direct metal laser sintering (DMLS), enable the creation of novel turbine cooling internal passages and systems. However, the DMLS method produces a significant and unique surface roughness. Previous work in scaled passages analyzed pressure losses and friction factors associated with the rough surfaces, as well as investigated the velocity profiles and turbulent flow characteristics within the passage. In this study, the heat transfer characteristics of scaled additively manufactured surfaces were measured using infrared (IR) thermography. Roughness panels were CNC machined from plates of aluminum 6061 to create near isothermal roughness elements when heated. Fluid resistance differences between the aluminum roughness panels and roughness panels constructed from ABS plastic using the same roughness patterns from McClain et al. (2020, “Flow in a Simulated Turbine Blade Cooling Channel With Spatially Varying Roughness Caused by Additive Manufacturing Orientation,” ASME Turbo Expo 2020, Turbomachinery Technical Conference and Exposition, Virtual Conference, Sept. 21–25, GT2020-16069) were investigated. Finally, the overall thermal performance enhancements and friction losses were assessed through the calculation of surface averaged “global thermal performance” ratios. The global thermal performance characterizations indicate results in-line with those found for traditional commercial roughness and slightly below traditional internal passage convection enhancement methods such as swirl chambers, dimples, and ribs. The passages investigated in this study do not include compressibility effects or the long-wavelength artifacts and channel geometric deviations observed by Wildgoose et al. (2020, “Impact of Additive Manufacturing on Internal Cooling Channels with Varying Diameters and Build Directions,” ASME Turbo Expo 2020, Turbomachinery Technical Conference and Exposition, Virtual Conference, Sept. 21–25, GT2020-15049). However, the results of this study indicate that, based on the roughness augmentation alone, artificial convective cooling enhancers such as turbulators or dimples may still be required for additively manufactured turbine component cooling.
A centrifugal impeller which was initially designed for a pressure ratio of approximately 5.5 and a mass flow rate of 0.959 kg/sec was tested with a vaneless diffuser for a range of design point impeller area ratios from 2.322 to 2.945. The impeller area ratio was changed by successively cutting back the impeller exit axial width from an initial value of 7.57 mm to a final value of 5.97 mm. In all, four separate area ratios were tested. For each area ratio a series of impeller exit axial clearances was also tested. Test results are based on impeller exit surveys of total pressure, total temperature, and flow angle at a radius 1.115 times the impeller exit radius. Results of the tests at design speed, peak efficiency, and an exit tip clearance of 8 percent of exit blade height show that the impeller equivalent pressure recovery coefficient peaked at a design point area ratio of approximately 2.748 while the impeller aerodynamic efficiency peaked at a lower value of area ratio of approximately 2.55. The variation of impeller efficiency with clearance showed expected trends with a loss of approximately 0.4 points in impeller efficiency for each percent increase in exit axial tip clearance for all impellers tested.
A centrifugal impeller which was initially designed for a pressure ratio of approximately 5.5 and a mass flow rate of 0.959 kg/sec was tested with a vaneless diffuser for a range of design point impeller area ratios from 2.322 to 2.945. The impeller area ratio was changed by successively cutting back the impeller exit axial width from an initial value of 7.57 mm to a final value of 5.97 mm. In all, four separate area ratios were tested. For each area ratio a series of impeller exit axial clearances was also tested. Test results are based on impeller exit surveys of total pressure, total temperature, and flow angle at a radius 1.115 times the impeller exit radius. Results of the tests at design speed, peak efficiency, and an exit tip clearance of 8 percent of exit blade height show that the impeller equivalent pressure recovery coefficient peaked at a design point area ratio of approximately 2.748 while the impeller aerodynamic efficiency peaked at a lower value of area ratio of approximately 2.55. The variation of impeller efficiency with clearance showed expected trends with a loss of approximately 0.4 points in impeller efficiency for each percent increase in exit axial tip clearance for all impellers tested.
This report presents a performance analysis of 75 photovoltaic systems based on PV system production data collected as part of a FEMP Federal PV Performance Assessment project combined with co-incident insolation, and ambient temperature to analyze how actual performance compares with a performance model. FEMP collaborated with 17 Federal agencies and sub-agencies to collect the information required to analyze the performance of each system. The systems represent a total capacity of 30,714 kW and range in size from 1 kW to 4,043 kW, with an average size of 410 kW, and were installed between 2011 and 2020. The data is analyzed for Key Performance Indicators, Availability, Performance Ratio and Energy Ratio by comparing the measured production data to model production data. The System Advisor Model (SAM) combines a description of the system (such as inverter capacity, de-rating for temperature, balance-of-system efficiency) with environmental parameters (coincident solar and temperature data) to calculate predicted performance. The performance metrics are calculated by lining up the measured production data with the model estimate on an hour-by-hour, day-by-day, or month-by-month basis (depending on the interval resolution of the production data). A report with system description, photo of the system, special assumptions made for the site, graph of measured production and model production, table of key performance indicators, and links to O&M resources that might improve performance was produced and delivered to site and agency staff with a short on-line briefing.