Search NASA⌕ Search

SEARCH · Search NASA

Results for “peristaltic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Stirring and peristaltic pumping alter flow electrode particle size and morphology

Flowable carbon-based electrodes are widely studied in electrochemical systems for energy storage and water treatment. Most laboratory- and pilot-scale studies employ active mixing for slurry preparation and handling and use peristaltic pumps for slurry circulation. Magnetic stirring is the most prevalent mixing method at the laboratory scale, and the combination of magnetic mixing and peristaltic pumping is favored for convenience and compatibility with particulate suspensions. However, these methods can strongly affect particle size and morphology (and therefore cell performance). In this study, we evaluate how mixing and pumping influence particle degradation in two commonly used carbon materials: spherical carbon black (CB) beads and powdered activated carbon (AC). We performed 24 h stirring-only experiments using magnetic, orbital, and overhead stirring. Separately, we conducted 32 h circulation experiments using a commercial peristaltic pump. Particle morphology and size were analyzed using optical microscopy and laser diffraction. The initially spherical CB beads (~580 μm, 1.5 wt%) exhibit rapid and extensive breakdown under both peristaltic pumping and magnetic stirring. By comparison, AC particles (initially ~31 μm) tested at 1.5 and 15 wt% showed measurable size reductions of up to ~25 % under either stirring or pumping. In conclusion, these findings highlight the need to account for and quantify morphological changes caused by both stirring and pumping in the design and associated evaluation of flowable electrode systems.

Chemistry↗

Multi-path peristaltic pump

The instant invention is directed to a peristaltic pump for critical laboratory or hospital applications requiring precise flow rates over an extended period of time. Within the cylindrical barrel pump housing is a single-piece, molded, elastometric, cylindrical liner with a multiplicity of flattened helical channels created therein from one end of the liner to the other. Three cylindrical rollers rotate about the center axis of the pump around the inside surface of the liner selectively compressing the liner, and hence the helical channels between the rollers and the barrel housing, creating a pumping action by forcing trapped fluid in the helical channels axially from one end of the liner to the opposite end. The novelty of the invention appears to lie in the provision of the special liner with multiple helical channels as the pumping chamber, rather than the standard single elastomeric tubing which is squeezed repeatedly by rollers to move the liquid through a typical peristaltic pump. Large, repeated deflections on the standard tubing causes a permanent set in the tubing, thus either changing the flow rate, or requiring a new section of tubing to be positioned in the pump head. Further, this configuration minimizes the amount of outflow pulsation which is characteristic of a typical single tubing peristaltic pump.

Chandler, Joseph A.↗

Remotely operable peristaltic pump

A peristaltic pump is disclosed which includes a roller assembly on which is mounted a series of pump rollers. As the roller assembly is rotated by a drive gear the pump rollers are driven in reverse rotation by means of a stationary ring gear and pump roller gears. An upper pressure shoe plate and a lower pressure shoe plate are positioned above sets of flexible tubing. The tubing is sandwiched between the pressure shoe plates and the pump rollers. A highly compact pump is provided having twice as many fluid channel lines as is conventional. The peristaltic pump device may be remotely operated by means of a rotary actuator which rotates a driving hub to move the shoe plates by means of eccentrically mounted links. The pressure shoe plates may be moved by the rotary actuator to a loaded position in which the fluid lines are pinched by the pump rollers and fluid is pumped to an unloaded position in which the fluid lines are maintained in an undeformed, uncrimped configuration so that no creases or crimps are set into the fluid lines during periods of prolonged nonuse.

Belew, R. R.↗

Lightweight, Switchable Peristaltic Pump

Peristaltic pump moves liquids through 50 or more channels simultaneously. Special feature of pump pressure plates remotely set between idle and operating positions. In new design, unnecessary to preposition pressure plates and, unnecessary to enter pump housing to move plates into operating mode.

Below, R. R.↗

Peristaltic Pump With a Stable Output

Proposed design for peristaltic pump decreases flow-rate change that results from loss of elasticity. Instead of tubing, new pump uses special flexible liner as pumping channel. Liner molded as single piece of flexible plastic with helical internal channels. Three rollers move around inner wall of liner, compressing channels and forcing liquid before constrictions. As rollers move on, channels open elastically, drawing in liquid from inlet port and making it available when rollers return.

Chandler, J. A.↗

Miniature Ring-Shaped Peristaltic Pump

An experimental miniature peristaltic pump exploits piezoelectrically excited flexural waves that travel around a ring: A fluid is carried in the containers formed in the valleys between the peaks of the flexural waves, What sets the present pump apart from other pumps that exploit piezoelectrically excited flexural waves is the ring shape, which makes it possible to take advantage of some of the desirable characteristics of previously developed piezoelectric rotary motors. A major advantage of the circular (in contradistinction to a straight-line) wave path is that the flexural waves do not come to a stop and, instead, keep propagating around the ring. Hence, a significant portion of the excitation energy supplied during each cycle is reused during the next cycle, with the result that the pump operates more effectively than it otherwise would.

Bar-Cohen, Yoseph↗

Pneumatically Actuated Miniature Peristaltic Vacuum Pumps

Pneumatically actuated miniature peristaltic vacuum pumps have been proposed for incorporation into advanced miniature versions of scientific instruments that depend on vacuum for proper operation. These pumps are expected to be capable of reaching vacuum-side pressures in the torr to millitorr range (from .133 down to .0.13 Pa). Vacuum pumps that operate in this range are often denoted roughing pumps. In comparison with previously available roughing pumps, these pumps are expected to be an order of magnitude less massive and less power-hungry. In addition, they would be extremely robust, and would operate with little or no maintenance and without need for oil or other lubricants. Portable mass spectrometers are typical examples of instruments that could incorporate the proposed pumps. In addition, the proposed pumps could be used as roughing pumps in general laboratory applications in which low pumping rates could be tolerated. The proposed pumps could be designed and fabricated in conventionally machined and micromachined versions. A typical micromachined version (see figure) would include a rigid glass, metal, or plastic substrate and two layers of silicone rubber. The bottom silicone layer would contain shallow pump channels covered by silicone arches that could be pushed down pneumatically to block the channels. The bottom silicone layer would be covered with a thin layer of material with very low gas permeability, and would be bonded to the substrate everywhere except in the channel areas. The top silicone layer would be attached to the bottom silicone layer and would contain pneumatic- actuation channels that would lie crosswise to the pump channels. This version is said to be micromachined because the two silicone layers containing the channels would be fabricated by casting silicone rubber on micromachined silicon molds. The pneumatic-actuation channels would be alternately connected to a compressed gas and (depending on pump design) either to atmospheric pressure or to a partial vacuum source. The design would be such that the higher pneumatic pressure would be sufficient to push the silicone arches down onto the substrates, blocking the channels. Thus, by connecting pneumatic- actuation channels to the two pneumatic sources in spatial and temporal alternation, waves of opening and closing, equivalent to peristalsis, could be made to move along the pump channels. A pump according to this concept could be manufactured inexpensively. Pneumatic sources (compressors and partial vacuum sources) similar those needed for actuation are commercially available; they typically have masses of .100 g and power demands of the order of several W. In a design-optimization effort, it should be possible to reduce masses and power demands below even these low levels and to integrate pneumatic sources along with the proposed pumps into miniature units with overall dimensions of no more than a few centimeters per side.

Feldman, Sabrina↗

Piezoelectrically actuated miniature peristaltic pump.

There is a range of NASA experiments, instruments and applications where miniature pumps are needed. To address such needs, a piezoelectrically actuated miniature pump is being developed. This pump employs a novel volume displacing mechanism using flexural traveling waves that acts peristaltically and eliminates the need for valves or physically moving parts. This pump is being developed for planetary instruments and space applications. Finite element model was developed using ANSYS for the purpose of prediction of the resonance frequency of the vibrating mode for the piezo-pump driving stator. The model allows determining simultaneously the mode shapes that are associated with the various resonance frequencies. This capability is essential for designing the pump size and geometry. To predict and optimize the pump efficiency that is determined by the volume of pumping chambers the model was modified to perform harmonic analysis.

Chang, Zensheu↗

Micromachined peristaltic pumps

Micromachined pumps including a channel formed between a first membrane and a substrate or between first and second flexible membranes. A series of electrically conductive strips is applied to a surface of the substrate or one of the membranes. Application of a sequential voltage to the series of strips causes a region of closure to progress down the channel to achieve a pumping action.

Hartley, Frank T.↗

Micromachined peristaltic pump

A micromachined pump including a channel formed in a semiconductor substrate by conventional processes such as chemical etching. A number of insulating barriers are established in the substrate parallel to one another and transverse to the channel. The barriers separate a series of electrically conductive strips. An overlying flexible conductive membrane is applied over the channel and conductive strips with an insulating layer separating the conductive strips from the conductive membrane. Application of a sequential voltage to the series of strips pulls the membrane into the channel portion of each successive strip to achieve a pumping action. A particularly desirable arrangement employs a micromachined push-pull dual channel cavity employing two substrates with a single membrane sandwiched between them.

Hartley, Frank T.↗

Development of an Innovative Inspection Tool for Superheater Tubes in Fossil Fuel Power Plants

Fossil fuel power plants are complex systems containing multiple components that require periodic health monitoring. Failures in these systems can lead to increased downtime for the plant, reduction of power, and significant cost for repairs. Inspections of the plant’s superheater tubes are typically manual, laborious, and extremely time-consuming. This is due to their small diameter size (between 1.3 and 7.6 cm) and the coiled structure of the tubing. In addition, the tubes are often stacked close to each other, limiting access for external inspection. This paper presents the development and testing of an electrically powered pipe crawler that can navigate inside 5 cm diameter tubes and provide an assessment of their health. The crawler utilizes peristaltic motion within the tubes via interconnected modules for gripping and extending. The modular nature of the system allows it to traverse through straight sections and multiple 90° and 180° bends. Additional modules in the system include an ultrasonic sensor for tube thickness measurements, as well as environmental sensors, a light detecting and ranging (LiDAR) sensor, and camera. Furthermore, these modules utilize a gear system that allows for 360° rotation and provides a means to inspect the entire internal circumference of the tubes.

36 MATERIALS SCIENCE↗

Development and characterization of the Capillary DirectINJECT System

The DirectINJECT Project was initiated to create a reliable in-line dosing system for delivering a concentrated silver ion biocide solution into spacecraft potable water. Three dosing systems, including a miniature peristaltic pump, a multi-piston pump, and a differential pressure-driven capillary tube, were quickly prototyped and tested. Although the peristaltic and multi-piston pump systems met the desired flow rate range, the capillary system showed the most promise and was chosen for further development. In FY23, the Capillary DirectINJECT dosing system underwent extensive testing with a nominal injection rate of 1.0 μl/min into varying backpressure conditions. A Primary DirectINJECT System with triplicate testbeds was employed for long-term testing, and auxiliary systems like the Secondary DirectINJECT System and Leak Testbed were developed to characterize specific components and investigate various phenomena related to the dosing system. Parameters such as flow rates, reservoir pressures, and temperature were monitored throughout the testing campaigns.

DirectINJECT↗

Microfluidic systems, pumps, valves, fluidic chips thereof, and applications of same

Microfluidic systems, pumps, valves and applications of the same are provided. The microfluidic system may be a pump or a valve having a fluidic chip and an actuator controlling the opening and closing of the fluidic channel in the fluidic chip. The actuator may be disposed to tilt from the fluidic chip, forming a tilted-rotor peristaltic pump. Alternatively, the actuator may be a rolling ball actuator, and different fluidic chips may be used in different applications. For example, the fluidic chip may be a spiral pump chip having spiral channels, a rotary peristaltic pump chip having multiple output channels, or a multi-port valve chip having one port interconnected with multiple different ports. An analytical valve chip may switchably interconnect bioreactor and rinse/calibration input channels to sensor and waste output channels. The actuator of a random-access valve can move from one valve position to another without opening or closing intermediate ones.

Reiserer, Ronald S.↗