Search NASA⌕ Search

SEARCH · Search NASA

Results for “phase calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Real-Time High-Accuracy Digital Wireless Time, Frequency, and Phase Calibration for Coherent Distributed Antenna Arrays

his work presents a fully-digital high-accuracy real-time calibration procedure for frequency and time alignment of open-loop wirelessly coordinated coherent distributed antenna array (CDA) modems, enabling radio frequency (RF) phase coherence of spatially separated commercial off-the-shelf (COTS) software-defined radios (SDRs) without cables or external references such as the global navigation satellite system (GNSS). Building on previous work using high-accuracy spectrally-sparse time of arrival (ToA) waveforms and a multistep ToA refinement process, a high-accuracy two-way time transfer (TWTT)-based time–frequency coordination approach is demonstrated. Due to the two-way nature of the high-accuracy TWTT approach, the time and frequency estimates are Doppler and multipath tolerant, so long as the channel is reciprocal over the synchronization epoch. This technique is experimentally verified using COTS SDRs in a lab environment in static and dynamic scenarios and with significant multipath scatterers. Time, frequency, and phase stability were evaluated by beamforming over coaxial cables to an oscilloscope which achieved time and phase precisions of ~60– 70 ps , with median coherent gains above 99% using optimized coordination parameters, and a beamforming frequency root-mean-square error (RMSE) of 3.73 ppb in a dynamic scenario. Finally, experiments were conducted to compare the performance of this technique with previous works using an analog continuous-wave two-tone (CWTT) frequency reference technique in both static and dynamic settings.

Clock synchronization↗

Time-of-Flight Calculations with Multiple Beam Phase Monitors: Calibration, Jitter Analysis & Energy Measurement

This report describes time-of-flight (ToF) beam energy measurements with multiple phase monitors in a beam line with no acceleration. Measurement uncertainty is quantified via rigorous treatment of beam-based phase monitor calibration and jitter analysis of the accelerator system. Experimental results in the Superconducting Linac (SCL) of the Spallation Neutron Source (SNS) are presented.

43 PARTICLE ACCELERATORS↗

ALMA Band-to-band Phase Referencing: Imaging Capabilities on Long Baselines and High Frequencies

High-frequency long-baseline experiments with the Atacama Large Millimeter/submillimeter Array were organized to test the high angular resolution imaging capabilities in the submillimeter wave regime using baselines up to 16 km. Four experiments were conducted, two Band 7 (289 GHz) and two Band 8 (405 GHz) observations. Phase correction using band-to-band (B2B) phase referencing was used with a phase calibrator only [[Formula]] away observed in Band 3 (96 GHz) and Band 4 (135 GHz), respectively. In Band 8, we achieved the highest resolution of 14 × 11 mas. We compared the synthesis images of the target quasar using 20 and 60 s switching cycle times in the phase referencing. In Band 7, the atmosphere had good stability in phase rms (<0.5 rad over 2 minutes), and there was little difference in image coherence between the 20 and 60 s switching cycle times. One Band 8 experiment was conducted under a worse phase rms condition (>1 rad over 2 minutes), which led to a significantly reduced coherence when using the 60 s switching cycle time. One of our four experiments indicates that the residual phase rms error after phase referencing can be reduced to 0.16 rad at 289 GHz in using the 20 s switching cycle time. Such conditions would meet the phase correction requirement of image coherence of >70% in Band 10, assuming a similar phase calibrator separation angle, emphasizing the need for such B2B phase referencing observing at high frequencies.

79 ASTRONOMY AND ASTROPHYSICS↗

Performance demonstration of vacuum microwave components critical for the operation of the ITER low-field side reflectometer

Final design studies in preparation for manufacturing have been performed for functional components of the vacuum portion of the ITER Low-Field Side Reflectometer (LFSR). These components consist of an antenna array, electron cyclotron heating (ECH) protection mirrors, phase calibration mirrors, and vacuum windows. Evaluation of these components was conducted at the LFSR test facility and DIII-D. The antenna array consists of six corrugated-waveguide antennas for simultaneous profile, fluctuation, and Doppler measurements. A diffraction grating, incorporated into the plasma-facing miter bend, provides protection of sensitive components from stray ECH at 170 GHz. For in situ phase calibration of the LFSR profile reflectometer, an embossed mirror is incorporated into the adjacent miter bend. Measurements of the radiated beam profile indicate that these components have a small, acceptable effect on mode conversion and beam quality. Baseline transmission characteristics of the dual-disk vacuum window are obtained and are used to guide ongoing developments. Preliminary simulations indicate that a surface-relief structure on the window surfaces can greatly improve transmission. The workability of real-time phase measurements was demonstrated on the DIII-D profile reflectometer. The new automated real-time analysis agrees well with the standard post-processing routine.

47 OTHER INSTRUMENTATION↗

Time-of-Flight energy measurements with BPMs

The energy of a bunched non-relativistic ion beam can be deduced from measuring the beam phases in neighboring Beam Position Monitors (BPMs). This report presents estimations on implementation of such a procedure at PIP-II H- linac being constructed at Fermilab. In part, the case when the flight time between BPMs is larger than the period of BPM frequency is considered in detail. When the absolute BPM phase calibration is not available, the BPM phase information can be used to trace deviations of the beam energy from the desired value. Such “energy deviation” parameter is operationally implemented at the transfer line between 400 MeV Linac and the Booster, and its analog is expected to be used in the transfer line from PIP-II as well.

Shemyakin, Alexander [Fermilab] (ORCID:00000001501↗

Time-of-Flight Energy Measurements With BPMs

The energy of a bunched non-relativistic ion beam can be deduced from measuring the beam phases in neighbouring Beam Position Monitors (BPMs). This report discusses implementation of such a procedure at the PIP-II H- linac being constructed at Fermilab. The case when the flight time between BPMs is longer than the period of BPM frequency is considered in more detail. When absolute BPM phase calibration is not available, the BPM phase information can be used to track deviations of the beam energy from the de-sired value. Such energy deviation parameter is operationally implemented at the transfer line between 400 MeV Linac and the Booster, and its analog is expected to be used in the transfer line from PIP-II as well.

Shemyakin, Alexander V. [Fermilab] (ORCID:00000001↗

81-beam coherent combination using a programmable array generator

We have generated 81 independently controllable beams using a spatial light modulator and combined them on a diffractive combiner, to characterize the combiner and develop a fast phase error detection scheme. A key parameter of the diffractive combiner is measured in a new way, enabling an efficient combination when programming calibrated phases of each beam. This testbed provides a platform for development of advanced feedback phase control of high channel-count beam combination.

Du, Qiang (ORCID:0000000221969801)↗

Ultra-broadband voltage-controlled oscillator linearization for frequency modulated continuous wave MMW imaging systems

Millimeter-wave (MMW) imaging systems require high resolution and spurious free dynamic range (SFDR) to produce images with low artifacts. In these systems, lateral resolution is determined by the center frequency and the ratio of the aperture size to the distance to the target. The downrange resolution is determined by the system bandwidth; for very fine downrange resolution of a target, or material layers/discontinuities, the bandwidth must be very broad. Additionally, the response over the bandwidth must be measured very rapidly to support high speed acquisition over large apertures. A voltage-controlled oscillator (VCO) is a standard means of generating the ultra-broadband frequency chirp. This paper investigates the use of a broadband VCO for use in MMW imaging systems, a linear-phase calibration technique, and digital-to-analog converter (DAC) parameter considerations for controlling the VCO.

FMCW, homodyne, VCO, DAC, difference frequency, SF↗

Calibration of the 2-Phase Bubble Tracking Model for Liquid Mercury Target Simulation with Machine Learning Surrogate Models

The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory is one of the most powerful accelerator-driven neutron sources in the world. The intense protons strike on SNS's mercury target to provide bright neutron beams, which also leads to severe fluid-structure interactions inside the target. Prediction of resultant loading on the target is difficult particularly when helium gas is injected into mercury to reduce the loading and mitigate the pitting damage on vessel walls. A 2-phase material model that incorporates the Rayleigh-Plesset (R-P) model is expected to address this multi-physics problem. However, several uncertain parameters in the R-P model require intensive simulations to determine their optimal values. With the help of machine learning and the measured target strain, we have studied the major uncertain parameters in this R-P model and developed a framework to identify optimal parameters that significantly reduce the discrepancy between simulations and experimental strains. The preliminary results show the possibility of using this mercury/helium mixture and surrogate models to predict a better match of target strain response when the helium gas is injected.

Lin, Lianshan↗

A laserball calibration device for the SNO+ scintillator phase

Located 2 km underground in SNOLAB, Sudbury, Canada, SNO+ is a large scale liquid scintillator experiment that primarily aims to search for neutrinoless double beta decay. Whilst SNO+ has light and radioactive calibration sources external to the inner volume, an internally deployed optical source is necessary for the full characterization of the detector model. A laser diffuser ball developed for SNO has previously demonstrated to be an effective optical calibration device for both SNO and SNO+ water phase. Since the introduction of liquid scintillator for SNO+, the material compatibility, cleanliness, and radiopurity requirements of any materials in contact with the internal medium have increased. Improving on the original SNO laserball design, a new laserball calibration device has been developed for the SNO+ scintillator phase with the goal of measuring the optical properties of the detector and performing routine PMT gain and timing calibrations. Simulations have been written to model the diffusion properties to optimise optical and temporal performance for calibration. Prototype laserballs have been built and characterised, demonstrating sub-ns timing resolution and a quasi-isotropic light distribution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibrating a finite-strain phase-field model of fracture for bonded granular materials with uncertainty quantification

To study the mechanical behavior of mock high explosives, an experimental and simulation program was developed to calibrate, with quantified uncertainty, a material model of the bonded granular material Idoxuridine and nitroplasticized Estane-5703. This paper reports on the efficacy of such a framework as a generalizable methodology for calibrating material models against experimental data with uncertainty quantification. Additionally, this paper studies the effect of two manufacturing temperatures and three initial granular configurations on the unconfined compressive behavior of the resulting bonded granular materials. In each of these cases, the same calibration framework was used; in that, hundreds of high-fidelity direct numerical simulations using a new, graphics processing unit-enabled, high-performance finite element method software, Ratel, were run to calibrate a finite-strain phase-field fracture model against experimental data. It was found that manufacturing temperature influenced the elastic response of the mock high explosives, with higher temperatures yielding a stiffer response. By contrast, it was found that the initial configuration of the grains had a negligible impact on the overall behavior of the mock high explosives though it remains possible that local damage accumulation within the specimens could be altered by the initial configurations. Overall, the calibration framework was successful at creating well-calibrated models, showing its usefulness as an engineering and scientific tool.

36 MATERIALS SCIENCE↗

An international benchmark for wind plant wakes from the American WAKE ExperimeNt (AWAKEN)

This article introduces the first benchmark study within the International Energy Agency Wind Task 57 framework, focusing on wind plant wakes. Leveraging data from the American WAKE ExperimeNt (AWAKEN), the benchmark aims to assess the accuracy of simulation tools in modeling wind plant wakes and their impact on the downstream flow under diverse inflow conditions. The AWAKEN field campaign, conducted in Oklahoma from 2022 to 2024, provides unprecedented observations of wind plant-atmosphere interactions, thus offering a large dataset to validate numerical models of different complexity. The benchmark will include three phases—code calibration, blind comparison, and iteration—allowing participants to refine their numerical models based on the feedback from the benchmark team. This article describes the benchmark case study selected from observations providing details on atmospheric conditions, wake evidence, and wind turbine operation. The benchmark’s structure and timeline, along with the expected publication of results, are discussed as well. This collaborative effort aims to enhance the accuracy of wind plant wake simulations, thus contributing to the improvement of wind energy production estimates.

17 WIND ENERGY↗

Conversions between gas-phase metallicities in MaNGA

ABSTRACT We present polynomial conversions between each of 11 different strong line gas-phase metallicity calibrations, each based on ∼1.1 million star-forming spaxels in the public Sloan Digital Sky Survey (SDSS) Data Release 15 (DR15) Mapping Nearby Galaxies at Apache Point Observatory (MaNGA) survey. For this sample, which is ∼20 times larger than previous works, we present fifth-order polynomial fits for each of 110 possible calibration conversions, for both Small Magellanic Cloud-type and Milky Way-type dust corrections. The typical 2σ scatter around our polynomial fits is 0.1 dex; we present the range over which the metallicities are valid. Conversions between metallicities which rely on the same set of line ratios, or a heavily shared set of emission lines, have reduced scatter in their conversions relative to those conversions with little overlap in required emission lines. Calibration conversions with less consistent sets of emission lines also have increased galaxy-to-galaxy variability, and this variability can account for up to 35 per cent of the total scatter. We also compare our conversions to previous work with the single fibre SDSS DR7 spectra along with higher spatial resolution data from the TYPHOON Integral Field Spectroscopy survey, resulting in comparison samples with spatial resolutions from several kpc down to ∼100 pc. Our metallicity conversions, obtained with the large sample of MaNGA, are robust against the influence of diffuse ionized gas, redshift, effective radius, and spatial blurring, and are therefore consistent across both integrated spectra and the high-resolution integral field spectroscopy data.

79 ASTRONOMY AND ASTROPHYSICS↗

Fourth Generation MPDV and MBR at DARHT

A new experimental setup for diagnosing hydrotest performance was designed, built, and implemented at DARHT. The setup consists of 128 points of fourth generation (Gen4) multiplexed photonic Doppler velocimetry (MPDV) and 128 separate points of modulation based ranging (MBR) to serve as a direct complement to the MPDV. The diagnostics were designed to overcome limitations in the third generation of the MPDV diagnostic that limited laser launch power to ~10 mW per point. As the main failure mechanism identified in the third generation MPDV system arose from stimulated Brillouin scattering, a nonlinear optical phenomenon inherent in standard single mode fiber, the fourth generation MPDV system reduced the number of time-multiplexed channels by a factor of two. This has allowed laser launch power to be increased to as much as 200 mW per channel which is a 20 times increase in the signal to noise ratio (SNR) as compared with the third generation system. This document will first discuss the previous limitations and describe the design of the system. This will be followed by the results of a simple flyer plate experiment used to demonstrate the improved SNR as well as calibrate the phase errors in the system that MBR is sensitive to.

42 ENGINEERING↗

Crabbing Angle Measurement

Electron-ion collider will employ transverse deflecting (crabbing) cavities to increase luminosity. There will be multiple cavities which will create localized crab bump in the interaction region. For proper compensation of the crossing angle each crab cavity should individually calibrated and phased.

43 PARTICLE ACCELERATORS↗

Dataset_for_Molecular_Motion_Below_the_Glass_Transition_A_Solid-State_NMR_Study_of_Siloxane_Polymer_Dynamics Study

This dataset contains solid-state 1H and 13C NMR relaxometry data, differential scanning calorimetry (DSC) data, and size exclusion chromatography (SEC/GPC) data supporting the study of sub-glass-transition (sub-Tg) molecular dynamics in a composition- and sequence-controlled series of diphenyl-substituted polysiloxanes (PDMS, 14Ph, 33Ph, 50Ph, 67Ph, and 100Ph; 0–100% diphenylsiloxane content by mole).All solid-state NMR data were acquired on a 200 MHz Bruker Avance III HD spectrometer using a static 7 mm HX probe or a 4 mm HX probe under 4 kHz magic-angle spinning. Raw Bruker TopSpin experiment folders are included for: (1) variable-temperature 1H lineshape measurements used to determine linewidth (FWHM) as a function of temperature across the glass transition; (2) 1H T1 (saturation recovery with solid-echo detection), probing nanosecond-scale dynamics near the 1H Larmor frequency; (3) 1H T1rho (direct spin-lock, 62.5 kHz), probing microsecond-scale segmental dynamics; (4) 13C-detected Lee–Goldburg cross-polarization 1H T1rho (LGCPH T1rho) for 33Ph and 50Ph, resolving aromatic and aliphatic proton environments; and (5) 13C T1 relaxation for 33Ph and 50Ph. Differential scanning calorimetry data (TA Instruments DSC 25, −150 to +120 °C, up to +300 °C for 100Ph, 10 °C/min) are included for all six compositions and support the glass-transition temperatures in Table 1 and Figure 1. Size exclusion chromatography data (Agilent 1200 Series, PL-Gel 300 mixed-C column, THF mobile phase, polystyrene calibration standards) are included for the three synthesized copolymers (33Ph, 50Ph, 67Ph) and support the number-average molecular weights in Table 1. Processed data include per-composition relaxation-time summaries (Excel), curve-fitting and Bloembergen-Purcell-Pound (BPP) model analysis notebooks (Jupyter/Python), and Igor Pro (.pxp) master files used to generate the manuscript's figures.

Bloembergen-Purcell-Pound theory↗

Calibration of Raman Spectrometer for Gas Phase Measurements

Raman spectroscopy is currently used at SRNL to measure the concentration of gaseous species evolved from chemical reactions. This report documents the methods used to calibrate the spectroscopic systems in both frequency and intensity spaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗